Anda di halaman 1dari 4

Page 1 of 4

Address History with Inspection Log


CONTACT_TYPE = Complainant, Neighbor, Tenant/Occupant, Applicant
CONTACT_TYPE = Blank
ADDR_PARTIAL : Begins With 2757 RITCHIE
APN = (Blank)
DATE_OPENED >= 10/1/2012
DATE_OPENED <= 12/31/2020
RECORD_TYPE_SUBTYPE <> Soft Story Retrofit Validation

Record ID: 1503597


Address: 2757 RITCHIE ST
APN: 040 340501000
Unit #:
Description: Ceiling framing: leaks. Damaged carpets: living room and bedrooms. Kitchen: sink-leaking/rotting, damaged
cabinets. Bathroom: broken showerhead-no water. Wooden framed windows: cracked glass, difficult to open causing lack
of ventilation. Front door : unsecure-does not shut properly.

Date Opened: 10/9/2015


Record Status: Violation Verified
Record Status Date: 10/14/2015
Job Value: $0.00
Requestor:
: MARIA
Business Name:
License #:
Inspection Date
10/14/2015
12/18/2015
4/19/2016

Inspector Name
Robert Walker
Robert Walker
Robert Walker
Robert Walker
Robert Walker
Robert Walker

Inspection Type

Status / Result

1st Inspection
Follow-up Inspection
Follow-up Inspection
1st Inspection
Follow-up Inspection
Follow-up Inspection
Follow-up Inspection
Follow-up Inspection
Follow-up Inspection

Violation Verified
No Abated
No Abated
Scheduled
Scheduled
Pending
Scheduled
Cancelled
Scheduled

Result Comments
10/14/15 Verified violations.
12/18/15 No access to interior.
4/19/16 No work being done at site today.

Record ID: DRX160156


Address: 2757 RITCHIE ST
APN: 040 340501000

https://adhoc1.accela.com/AdhocReportWeb/Report/rs.aspx?p=htmlreport&print=1&refrn...

10/6/2016

Page 2 of 4

Unit #:
Description: Replace all existing windows, same opening size and style, new-vinyl, keep wood trim: front should be fixed in
middle and on sides should be either fixed or vertical hinge; window on NE side of house should include divided light to
match existing;

Date Opened: 2/5/2016


Record Status: Approved
Record Status Date: 2/5/2016
Job Value: $0.00
Requestor: KUKREJA MOHIT
:
Business Name:
License #:
Inspection Date

Inspector Name

Inspection Type

Status / Result

Result Comments

Record ID: DRX160986


Address: 2757 RITCHIE ST
APN: 040 340501000
Unit #:
Description: Zoning approval to relocate the water heater outside the house but against the rear wall and under the
cantilevered story above. Exhaust pipes to run along underside of the 2nd story and up the wall. See address file for site
plan/diagram.

Date Opened: 6/10/2016


Record Status: Approved
Record Status Date: 6/10/2016
Job Value: $0.00
Requestor:
: Dickens Thoms
Business Name:
License #:
Inspection Date

Inspector Name

Inspection Type

Status / Result

Result Comments

Record ID: RB1600508


Address: 2757 RITCHIE ST
APN: 040 340501000
Unit #:
Description: Replace all windows w/retrofit type, replace front door and remodel kitchen and bathroom. Work to be finalled
by 7-6-16. #1503597.

Date Opened: 2/5/2016


Record Status: Issued
Record Status Date: 2/5/2016
Job Value: $10,000.00
Requestor: KUKREJA MOHIT
:
Business Name:
License #:
Inspection Date

Inspector Name

Inspection Type

Status / Result

Result Comments

https://adhoc1.accela.com/AdhocReportWeb/Report/rs.aspx?p=htmlreport&print=1&refrn...

10/6/2016

Page 3 of 4

Record ID: RP1600282


Address: 2757 RITCHIE ST
APN: 040 340501000
Unit #:
Description: Plumbing/ interior repairs and water heater flue. Permits to be finaled by 7-6-16. #1503597. 06-10-16 add
relocate water heater, gas test/low pressure and flue.

Date Opened: 2/5/2016


Record Status: Permit Issued
Record Status Date: 2/5/2016
Job Value: $0.00
Requestor:
:
Business Name: DICKENS THOMAS CONSTRUCTION
License #: 829884
Inspection Date

Inspector Name

Inspection Type

Status / Result

6/3/2016

Alan Albee

Frame

Not Pass

6/30/2016
7/5/2016
7/8/2016

Reynaldo Jimenez
Felix Melendez
Robert Bernal

Final Plumbing
Final Plumbing
Final Plumbing

Cancelled In Field
Not Pass
Partial

Robert Bernal

Frame

Cancelled

Result Comments
Date: 6/3/2016 Tub installation and tub test OK.
Correction notice for water heater flue: 1. B-vent
required for flu in enclosed framing. 2. Horizontal runs
a vent require 1 inch and 4 feet rise. 3. 1 foot vertical
rise required for every foot of horizontal run. 4.
Approved fittings, terminations, and support required,
per manufacturers installation instructions.
Date: 6/30/2016 Canceled infield
Date: 7/5/2016 Not ready.
Date: 7/8/2016 Gas pressure test is OK. For final finish
roof top termination of vent pipe, bond hot, cold and
gas pipes, use approved earthquake straps to secure
the water heater.

Record ID: SL1202486


Address: 2757 RITCHIE ST
APN: 040 340501000
Unit #:
Description: Repair/replace building sewer ON PROPERTY ONLY. SL & X required beyond PL. Overflow device may be
needed. Call PWA INSPECTION prior to start: 510-238-3651. 4th FLOOR.

Date Opened: 11/19/2012


Record Status: Permit Issued
Record Status Date: 11/19/2012
Job Value: $0.00
Requestor: PLUMBING MINISTRY, THE
:
Business Name:
License #: 894946
Inspection Date

Inspector Name

Inspection Type

Status / Result

Result Comments

For real-time, direct access to


information via the Internet, 24
hours a day -

https://adhoc1.accela.com/AdhocReportWeb/Report/rs.aspx?p=htmlreport&print=1&refrn...

10/6/2016

Page 4 of 4

https://aca.accela.com/oakland

https://adhoc1.accela.com/AdhocReportWeb/Report/rs.aspx?p=htmlreport&print=1&refrn...

10/6/2016

Anda mungkin juga menyukai