Anda di halaman 1dari 8

+

DINAGAS
PRESSURIZED COLLECTIVE FLUE SYSTEM FOR SEALED SINGLEPOSITIVE

..

ft t
r ch
ep a
r g rw
te be
us n
um tio
Ba duk
Pro

Pro
du Typ
cti e
on tes
m ted
on
ito
re
d

PRESSURE GAS CONDENSING BOILERS

TUV
..

SUD

0036

EN 1856-1

0036 CPD 90220 023


EN 1856-1

T200 P1 W V2-L50040 050

ISO 9001 : 2008

NEW
THE SIMPLE AND
EFFECTIVE ANSWER
TO COLLECTIVE
EVACUATION OF
PRESSURIZED
SINGLE GAS
CONDENSING
BOILERS

new

DINAGAS+

ASSEMBLY TYPE

THE DINAGAS+ SYSTEM

GAS

010E2

+ A stainless steel concentric chimney for the collective

FINAL ELEMENT
AIR INTAKE
GAS OUTLET

940 mm.

AIR

evacuation of sealed single gas positive pressure


condensing boilers , which incorporate a non-return
valve.

+ The evacuation of gases is done through an inner


Elbow sections
available in
45,30,15

STORM COLLAR

flue and the oxidising contribution in each boiler is


done through an outer flue from the final element.

+ The tightness of the system is guaranteed by the


940 mm.

silicone seal placed on the inner and outer wall.

CHARACTERISTICS AND ADVANTAGES


017

ADJUSTABLE FLASHING
30/45

080E2

WALL SUPPORT

020E2

STRAIGHT LENGTH 960mm

Tee branches
available
Male:
60/100 and 80/125
These dimensions are available
in the following configurations:

940 mm.

940 mm.

036E2

93 TEE - BRANCH 60/100

Non-return valve
(1 for each
boiler)

Easy, quick and safe


assembly
The ease of assembling a male
female end fitted system, together
with one of the characteristics
common in all Dinak flues, the
manufacturing of safety end folded
edges, makes this new product an
easy, quick and safe assembly
As there are adjustable elements
from 350 mm up to 1100 mm (3
different adjustables in total) this
allows for the ease of any job in
question.

221E2

760-1380 mm.

2640-3260 mm.

ADJUSTABLE ELEMENT

Adjustable elements available:


221E2 L= 760 - 1380 mm
022E2 L= 510 - 880 mm
023E2 L= 340 - 545 mm

070E2

LOCKING BAND

Tightness
The tightness is assured
by the:
- Two seals in each fit

940 mm.

- An inner cap welded by plasma


- An extruded T

901E2

Finished Design

SLAB SUPPORT
COLLAR

940 mm.

366

93 TEE - BRANCH 60/100

Soot collector
061E2

FLUE PLATE

The finished design of the Dinagas


3CE+ system is discreet and at the
same time modern, bringing together
functionality and architectural
integration.

new

DINAGAS+

MATERIALS
INNER WALL:

OUTER WALL:

Stainless Steel AISI 316L (1.4404).

Aluminized stainless steel (for interior assembly)


Stainless Steel AISI 304 (1.4401).
Stainless Steel AISI 316L (1.4404).

SEAL: Silicone.

The design of the DINAGAS 3CE has been done in accordance with the En 13384-2.
,1
ranxo

9. 36216 VIGO -SPAIN. +3


4 98
6 45
25
26

+3
49
86

DINAK
IA
TIO

E
OP

E UR

CHI

www.dinak.com

ECA

AN

MN EYS AS

SO

REQUEST OUR SOFWARE DINAKALC CE IV TO CALCULATE THE DIMENSIONS OF


THE CHIMNEYS, BASED ON THE REGULATIONS EN13384-1 (*) AND EN 13384-2 (**)
AND APPROVED BY THE TV (Technical Inspection Service).

45
4

om
k.c
ina
@d
les
sa
219

o La
od
mi
Ca
.A.
,S
K
NA
DI

(*) EN 13384-1: individual chimneys (boilers and generator groups )


(**) EN 13384-2: collective chimneys: multi-entry or in cascade

NEW

OFFER FOR COLLECTIVE


DINAGAS FLUE SYSTEMS
This software produces a
complete offer including a
2D diagram, list of items
and economic valuation.

New
Dimensioning of collective chimneys in depression and in pressure
Integration of the system QUICK QUOTATION
Automatic orders
Updating of prices through Internet
Data base of boilers with the possibility of updating through the Internet

V.4.0.0

DINAKALC CE IV
CHIMNEY SIZING PROGRAM ACCORDING TO THE EUROPEAN STANDARDS:
EN 13384-1 (individual chimneys: boilers and power generators)
EN 13384-2 (collective chimneys: multi-inlet and cascade arrangements)

GENERAL CONDITIONS:
Generator

Flue Plate

Power:
Fuel:
Maximum pressure:
Nominal yield /min.:
Nominal temperature of fumes /min.:

25 kW
Natural gas
70 Pa
98% / 107%
70 C / 45 C

Environment
Average temperature of environment max./min.: 15 C / 0 C
Assembly:
Interior

Diameter inner /outer:


Length:
Part:

80 / 125 mm
2m
1 elbow of 87

Chimney
Distance between floors:
Distance on finishing:

3m
3m

CONDENSING BOILERS

Double connection: 1 boiler of 25 kW per floor

Simple connection: 1 boiler of 25 kW per floor


o

N . of boilers

2-5
6-7
8

mm inner nominal

125
150
175

mm

outer nominal

200
225
275

N . of boilers

2-4
6
8 - 10
12 - 14
16

mm

inner nominal

125
150
175
200
250

mm

outer nominal

200
225
275
300
400

CAT/DGPLUS-UK-101

Other DINAGAS ranges available

AIR

0036 CDP 90220 010

GAS

DINAGAS
AIR

INNER WALL AISI 316L ( 1.4404 )


EN 1856-1 T 160 N1 W V2 L50040 O00
INNER WALL AISI 304 ( 1.4301 )
EN 1856-1 T 160 N1 W Vm L20040 O00
Natural draught collective evacuation
system for sealed individual gas boilers
type C42 y C43.

AI

GA

GAS

AI

DINAK UK
Unit 4 Albertine Close
Sweet Briar Industrial Estate
NORWICH - NR3 2FA
016 03 48 27 06
016 03 42 90 20
uk@dinak.com

AIR

GA

AI

DINAGAS

OUTER ASSEMBLY
0036 CDP 90220 011
MANCHESTER

SZCZECIN

INNER WALL AISI 316L ( 1.4404 )


EN 1856-1 T160 N1 W V2 L50040 O00
INNER WALL AISI 304 ( 1.4301 )
EN 1856-1 T160 N1 W Vm L20040 O00
TOULOUSE

E
OP

ECA

AN

CHI

MNEYS AS

IA
TIO

EUR

www.dinak.com

ALICANTE

SO

AI

HEAD OFFICE DINAK


Camio do Laranxo, 19
36216 Vigo - SPAIN
+34 986 452 526
+34 986 454 192
sales@dinak.com

DINAGAS
SHARED SYSTEM CHIMNEY FOR MULTIPLE BOILER INSTALLATIONS IN APPARTMENT

..

ft t
r ch
ep a
r g rw
te be
us n
um tio
Ba duk
Pro

Pro
du Typ
cti e
on tes
m ted
on
ito
re
d

BUILDINGS (FOR ROOM-SEALED FAN DRAUGHT C4 APPLIANCES)

TUV
..

SUD

EN 1856-1

0036

DINAGAS
0036 CPD 90220 010
INTERNAL MATERIAL AISI

316L (1.4404)

EN 1856-1
T 160 N1 W V2 L50040 O(00)
INTERNAL MATERIAL AISI

304 (1.4301)

EN 1856-1
T 160 N1 W Vm L20040 O(00)

www.dinak.com

Product in line
with the new
BS 5440-1:2008,
which came into effect
on 31 March 2008

Air

Gas

Air

TECHNICAL DRAWING FOR


CONDENSING AND STANDARD
BOILERS

TERMINAL FOR GAS


OUTLET/AIR INTAKE
Outside + 180 mm
mm

Gas
010E

TERMINAL
955 mm

CONCENTRIC NEGATIVE PRESSURE CHIMNEY THAT


ALLOWS SIMULTANEOUS AIR INTAKE AND GAS
OUTLET, WHICH CAN BE USED ON ROOM-SEALED
FAN DRAUGHT CONDENSING OR NON
CONDENSING C4 APPLIANCES (C42 AND C43).

955 mm.

DINAGAS

Air

013

STORM COLLAR

960 mm.

GASTEC TESTED
(report Nw/wld/14E04/055)
Complies with the
aerodynamic performance
criteria specified in
BS 5440-1:2008

017

FLASHING

080

WALL SUPPORT

020

STRAIGHT LENGTH 960 mm.


93 TEE - BRANCH 60/100

960 mm.

036E

371

93 TEE - PARALLEL
BRANCH 80 mm.

901

CONCRETE
SLAB SUPPORT

MATERIALS
Outer wall:
. AISI 304 (1.4301).
. AISI 316L (1.4404).
. Aluminized Steel (for inside installations)

710 mm.

Air intake.

93 TEE

221E

ADJUSTABLE LENGTH

930-1330 mm.

Inner wall:
. AISI 304 (1.4301): standard boilers.
. AISI 316L (1.4404): condensing boilers.

FINISHING

Painted (Ral range).

WORKING TEMPERATURE

070

LOCKING BAND
93 DOUBLE BRANCHED TEE 180

960 mm.

160 C.

93 DOUBLE BRANCHED TEE 90

901
710 mm.

CONCRETE SLAB SUPPORT


93 TEE - BRANCH 80/125

Wind test of Dinagas terminal at GASTEC laboratory


020

STRAIGHT LENGTH 960 mm.

960 mm.

Dinagas terminal has been tested at the wind tunnel of


GASTEC laboratory (test report Nw/wld/14E04/055),
and fulfils the design criteria of BS 5440-1:2008 Annex
F (normative), for terminals of shared system chimneys,
in terms of aerodynamic properties and percentage of
recirculation.

061E

SOOT COLLECTOR WITH


DRAIN / DRAFT REGULATOR

Dinak reserves the right to change any information on this brochure without notification

DINAGAS SIZING ACCORDING TO THE BS EN 13384-2 STANDARD


The new BS 5440-1:2008 specifies in his clause 12.1.6 Sizing for shared system chimneys,
that the sizing shall be calculated according to BS EN 13384-2.

STANDARD BOILERS

CONDENSING BOILERS
GENERAL CONDITIONS:

GENERAL CONDITIONS:
Heating appliance
Fuel

Natural Gas
Nominal
Minimum
92 %
140 C
/
90 C
50 Pa
/
50 Pa

Efficiency
Flue gas temperature
Positive pressure
Environment
Altitude

Heating appliance
Fuel
Efficiency
Flue gas temperature
Positive pressure
Environment
Altitude
Ambient temperature
Installation

1m
0,2 m
1 x 87 elbow
60 / 100 mm
80 / 125 mm

Connecting flue pipe


Length
Height
Element
Diameter (Outputs 20,25 and 30 kW)
Diameter (Output 35 kW)

1m
0,2 m
1 x 87 elbow
60 / 100 mm
80 / 125 mm

3m
3m

Chimney
Floor distance
Distance to outlet

3m
3m

Ambient temperature
Installation
Connecting flue pipe
Length
Height
Element
Diameter (Outputs 20,25 and 30 kW)
Diameter (Output 35 kW)
Chimney
Floor distance
Distance to outlet

1 BOILER PER FLOOR


mm

285
340
390
285
340
390
285
340
390
425
285
340
390
425
475

N of boilers

20 kW

150
180
205
150
180
205
150
180
205
225
150
180
205
225
250

1 BOILER PER FLOOR


External nominal

25 kW

mm

30 kW

2-5
6-7
8
2-4
5-6
7-8
2-3
4-5
6-7
8
2
3-4
5-6
7
8

Internal nominal

35 kW

25 kW 20 kW
30 kW
35 kW

N of boilers

Minimum
107 %
45 C
50 Pa

50 m
Maximum Minimum
15 C
/
0 C
Inside building

50 m
Maximum Minimum
15 C
/
0 C
Inside building

OUTLET

Natural Gas
Nominal
98 % /
70 C /
50 Pa /

mm

2-4
5-6
7-8
2-3
4-5
6-7
8
2-3
4
5-6
7
8
2
3
4-5
6
7-8

Internal nominal

150
180
205
150
180
205
225
150
180
205
225
250
150
180
205
225
250

mm

External nominal

285
340
390
285
340
390
425
285
340
390
425
475
285
340
390
425
475

2 BOILERS PER FLOOR

2 BOILERS PER FLOOR

150
180
205
225
250
300
150
180
205
250
300
150
180
205
225
250
300
150
205
225
250
300
350

mm

N of boilers
External nominal

285
340
390
425
475
575
285
340
390
475
575
285
340
390
425
475
575
340
390
425
475
575
675

20 kW

Internal nominal

25 kW

2-4
6
8
10
12 - 14
16
2
4
6-8
10 - 12
14 - 16
2
4
6
8
10
12 - 16
2
4
6
8
10 - 12
14 - 16

mm

30 kW

N of boilers

35 kW

35 kW

30 kW

25 kW

20 kW

OUTLET

2
4
6
8
10 - 12
14 - 16
2
4
6
8
10
12 - 14
16
2
4
6
8
10 - 12
14 - 16
2
4
6
8 - 10
12 - 16

mm

Internal nominal

150
180
205
225
250
300
150
180
205
225
250
300
350
150
180
225
250
300
350
180
225
250
300
350

mm

External nominal

285
340
390
425
475
575
285
340
390
425
475
575
675
285
340
425
475
575
675
340
425
475
575
675

CAT/DG-UK-105

ASK FOR OUR NEW CALCULATION


SOFTWARE DINAKALC CE III,
ACCORDING TO THE BS EN 13384-1
AND BS EN 13384-2 STANDARDS.
0036

NEW

- 14 -926

DINAKALC CE III
software certified by ECA
(European Chimney Association)

and ESCHFOE (European Federation


of Chimney-Sweeps) and has passed the
required calculation tests at TV

DINAK UK

Unit 4 Albertine Close


Sweet Briar Industrial Estate
NORWICH - NR3 2FA

F 016 03 48 27 06
6 016 03 42 90 20.
uk@dinak.com
HEAD OFFICE DINAK

Camio do Laranxo, 19
36216 Vigo - SPAIN

F +34 986 452 526


6 +34 986 454 192.
nxo

+3 4

986

454

-s a
le

CI
AT
ION

OP

EUR

O
SS
NEYS A

BRUSSELS CO
ME LO
RO
GN

-M

LYON - P
BAO ARI
BIL
S
IA
NC

O
IG

OFFER FOR COLLECTIVE


DINAGAS FLUE SYSTEMS
This software produces a
complete offer including a
2D diagram, list of items
and economic valuation.

H - LODZ - MOSC
WIC
OW
OR
-V
-N

MANCHESTER

ID - BARCELONA
ADR
-V
-M
AL
E
V.3.0.0

DINAKALC CE III

SZCZECIN
KLN

TOULOUSE

ALICANTE

CHIMNEY SIZING PROGRAM ACCORDING TO THE EUROPEAN STANDARDS:


EN 13384-1 (individual chimneys: boilers and power generators)
EN 13384-2 (collective chimneys: multi-inlet and cascade arrangements)

Certified ISO 9001 by

OP

EUR

www.dinak.com

48259

ECA

EA
N

CI
AT
ION

NEW

NLA

CHIM

www.dinak.com

ECA

EA
N

.co

DINAK

19
2

O
SS
NEYS A

CHIM

IMASCECOMUNICACIONGRAFICA

a ra

5 26 6

ak

D IN
AK

oL

O -SPAIN. F +34 986 452

din

,S

am
.C

d
io

16 V I G

s@

.A

sales@dinak.com
. 3 62
, 19

Anda mungkin juga menyukai