Anda di halaman 1dari 22

Instrument Manifolds

Index

General Purpose Manifolds


Overview
2Valve
3Valve
5Valve
Mounting kits

1
2
4
6
8

Special Application Manifolds


Trifold 3Valve
Rotofold 3Valve
Pentafold 5Valve
Mounting kits

instrument manifolds

HOKE, Inc.
405 Centura Court PO Box 4866 (29305) Spartanburg, SC 29303
Phone (864) 574-7966 Fax (864) 587-5608
www.hoke.com sales@hoke.com

9
12
15
17

General Purpose Instrument Manifolds at a Glance


Hoke offers a variety of 2-,3-, and 5-valve instrument manifolds in direct and remote
mount styles with vent configurations to meet most flow, pressure, and level
measurement application requirements. Hoke 2valve manifolds are designed for static
pressure and liquid level applications; the 3 and 5valve manifolds are well suited for
use with most differential pressure transmitters and can accept both female and flange
process impulse line connections.

Valve Features
All valves are hydrostatically tested at 1.5X maximum working pressure to assure leak tight
performance. Stem packing is available in PTFE or Grafoil materials with the metal nonrotating stem tip offered as standard.

Gland adjuster packing seal can


be externally adjusted in service

Dust cap on stem prevents inflow


of contamination and protects
actuating threads

Safety locknut
Stem has rolled threads for smooth
acting, strength, and long life. Stem
threads above packing, no process
contamination or lube washout

Packing is below the stem threads


to isolate threads from process media
Dead stem through packing giving ease
of operation and less packing wear

One piece non-rotating stem


tip joint located above packing,
cannot work free

Stem has back seat


for added security
Precision Machined hard stem
tip of AISI 316 stainless steel
provide consistent shutoff

Metal to metal seal with body


suitable for high pressure
temperature applications. No
need for O-ring seals.

Pressure vs. Temperature Curves


GRAFOIL PACKING

Maximum pressure 6000 psi (413 bar) at 212 F (100 C)


Maximum pressure 4000 psi (275 bar) at 392 F (200 C)
Maximum pressure 6000 psi (413 bar) at 212 F (100 C)
Maximum pressure 3300 psi (230 bar) at 842 F (450 C)

* PTFE packing rated to maximum temperature of 392 F (200 C)

8702 (600)
7252 (500)

PSI (Bar)

PTFE PACKING*

5802 (400)
4351 (300)
2901 (200)
1450 (100)
0
0

212 392 572 752 932 1112


(100) (200) (300) (400) (500) (600)

Fahrenheit (Celsius)
PTFE Packing

HOKE, Inc.
405 Centura Court PO Box 4866 (29305) Spartanburg, SC 29303
Phone (864) 574-7966 Fax (864) 587-5608
www.hoke.com sales@hoke.com

Grafoil Packing

instrument manifolds

Removable T bar handle aids


low torque operation

2Valve General Purpose ManifoldDirect Mount


Dimensions
Dimensions in inches (millimeters) are for reference only and are subject to change.

INSTRUMENT
PORT
VENT

PROCESS IN

Front view
5.63 (143 mm)
3.35 (85 mm)
2.125 (54 mm)

Right side view

1
0 (6

mm

4.76 (121 mm)

1.625
(41.3 mm)

2.4

(63.5 mm)

NPT inlet
connection

Vent valve
(dustcap: red)

0.79
(20 mm)

NPT vent plug


(supplied loose)

Back view
Isolate valve
(dustcap: blue)

0.51
(13 mm)
1.50
(38.1 mm)

FOR YOUR SAFETY

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM DESIGNER


AND USER TO SELECT PRODUCTS SUITABLE FOR THEIR
SPECIFIC APPLICATION REQUIREMENTS AND TO ENSURE
PROPER INSTALLATION, OPERATION AND MAINTENANCE
OF THESE PRODUCTS. MATERIAL COMPATIBILITY,
PRODUCT RATINGS AND APPLICATION DETAILS SHOULD
BE CONSIDERED IN THE SELECTION. IMPROPER SELECTION
OR USE OF PRODUCTS DESCRIBED HEREIN CAN CAUSE
PERSONAL INJURY OR PROPERTY DAMAGE.
2

HOKE Instrument Manifolds

0.46 (11.8) dia

Transmitter interface
per IEC 61518, Type B
2.125 0.012 - in.
Center
2 Mounting holes
M8 x 0.47 (12) deep

How to Order
PART NUMBER
GP821211F8YL

PACKING
PTFE

GP821212F8YL

Grafoil

ACCESSORIES (NOT INCLUDED)


Mounting kitOrder No. 800000K1 (page 8)
1.5 mounting bolts for Honeywell transmitter
(4 required) Order No. 095-0411-100

2Valve General Purpose ManifoldRemote Mount


Dimensions
Dimensions in inches (millimeters) are for reference only and are subject to change.
INSTRUMENT
PORT
VENT

PROCESS IN

4.45 (113 mm) open

2.75 (70 mm)

Vent valve
(dustcap: red)

Front view

0.59
(15 mm)

2.40 (61 mm)

1.18
(30 mm)

Isolate valve
(dustcap:blue

0.56
(14.3 mm)

NPT vent plug


(supplied loose)

1.125
(28.6 mm)

0.26 (6.5)
thru hole
1.25 (32 mm)

2.165 (55 mm)

3.43 (87 mm) open

Right side view

NPT
outlet

NPT
inlet

1.65 (42 mm)


2.75 (70 mm)

FOR YOUR SAFETY

How to Order
PART NUMBER
PACKING
GP823211F8YL
PTFE
GP823212F8YL
Grafoil
Mounting kitOrder No. 800000K2 (page 8)

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM DESIGNER AND USER TO SELECT PRODUCTS SUITABLE FOR THEIR SPECIFIC
APPLICATION REQUIREMENTS AND TO ENSURE PROPER INSTALLATION, OPERATION AND MAINTENANCE OF THESE PRODUCTS.
MATERIAL COMPATIBILITY, PRODUCT RATINGS AND APPLICATION DETAILS SHOULD BE CONSIDERED IN THE SELECTION.
IMPROPER SELECTION OR USE OF PRODUCTS DESCRIBED HEREIN CAN CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.
HOKE Instrument Manifolds

3Valve General Purpose ManifoldDirect Mount


Dimensions
Dimensions in inches (millimeters) are for reference only and are subject to change.
INSTRUMENT PORTS
BLEED/
PURGE

BLEED/
PURGE

NPT
NPT
PROCESS IN

2.125 (54.0)*
(2) mounting holes,
M10 X 0.39 (10) deep

5.04 (128) maximum opeing

1.50 (38.1)

Bottom

2.50 (63.5)

0.63
(15.9)

Side view

1.97 (50.0)
3.94 (100.0)
1.25
(31.8)

*Transmitter interface per IEC 61518, Type B

Isolate valve
(dustcap: green)

Front view

1.61 (41)
FOR YOUR SAFETY

Isolate valve
(dustcap: blue)

NPT
vent port

0.56 (14.3)

1.63 (41.3)

Isolate valve
(dustcap: blue)

NPT vent
plug (supplied
loose)

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM DESIGNER


AND USER TO SELECT PRODUCTS SUITABLE FOR THEIR
SPECIFIC APPLICATION REQUIREMENTS AND TO ENSURE
PROPER INSTALLATION, OPERATION AND MAINTENANCE
OF THESE PRODUCTS. MATERIAL COMPATIBILITY,
PRODUCT RATINGS AND APPLICATION DETAILS SHOULD
BE CONSIDERED IN THE SELECTION. IMPROPER SELECTION
OR USE OF PRODUCTS DESCRIBED HEREIN CAN CAUSE
PERSONAL INJURY OR PROPERTY DAMAGE.

How to Order
2.13 (54)
4.02 (102)
6.50 (165.1)

HOKE Instrument Manifolds

4X DIA
0.46 (11.8)

PART NUMBER
PACKING
GP831211F8YL
PTFE
GP831212F8YL
Grafoil
Mounting kitOrder No. 800000K1 (page 8)
1.5 mounting bolts for Honeywell transmitter
(4 required) Order No. 095-0411-100

3Valve General Purpose ManifoldRemote Mount


Dimensions
Dimensions in inches (millimeters) are for reference only and are subject to change.
TO INSTRUMENT
VENT

VENT

NPT
NPT
PROCESS IN

Top view
2.39 (60.8)

Bottom

3.54 (90)

8.15 (207) open

Isolate valve
(dustcap: blue)

NPT
inlets

2.50 (63.5)
Isolate valve
(dustcap: blue)

0.28 (7) dia

Side view

1.57 (40.0)

4.06 (103) Side open

2 NPT
vent plugs
(supplied loose)

2.13 (54,0)

NPT
outlets

0.56
(14.3)

Equalize valve
(dustcap: green)

0.63
(15.875)

1.46
(37.1)

1.75
(44.45)

FOR YOUR SAFETY

How to Order
PART NUMBER
PACKING
GP833211F8YL
PTFE
GP833212F8YL
Grafoil
Mounting kitOrder No. 800000K2 (page 8)

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM DESIGNER AND USER TO SELECT PRODUCTS SUITABLE FOR THEIR SPECIFIC
APPLICATION REQUIREMENTS AND TO ENSURE PROPER INSTALLATION, OPERATION AND MAINTENANCE OF THESE PRODUCTS.
MATERIAL COMPATIBILITY, PRODUCT RATINGS AND APPLICATION DETAILS SHOULD BE CONSIDERED IN THE SELECTION.
IMPROPER SELECTION OR USE OF PRODUCTS DESCRIBED HEREIN CAN CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.
HOKE Instrument Manifolds

5Valve General Purpose ManifoldDirect Mount


Dimensions
Dimensions in inches (millimeters) are for reference only and are subject to change.
INSTRUMENT PORT
VENT

VENT

PROCESS IN

3.00 (7.62)

Side view

Front view

0.49
(12.4)

Equalize valve
(dustcap: green)

Vent valve
(dustcap: red)

NPT
inlet

Transmitter
interface
per IEC
61518,
Type B

4.02 (102)
5.51 (140)
6.22 (158)
10.83 (275) open

HOKE Instrument Manifolds

4X DIA
0.46 (11.8)

2.125 (54)
3.94 (100)

NPT
plugged
port

1.61
(41)

FOR YOUR SAFETY

1.63
(41.3)

5.04 (128) open

Isolate valve
(dustcap: blue)

1.25
(31.8)

NPT Vent
PLUGS
(supplied loose)

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM


DESIGNER AND USER TO SELECT PRODUCTS
SUITABLE FOR THEIR SPECIFIC APPLICATION
REQUIREMENTS AND TO ENSURE PROPER
INSTALLATION, OPERATION AND MAINTENANCE
OF THESE PRODUCTS. MATERIAL COMPATIBILITY,
PRODUCT RATINGS AND APPLICATION DETAILS
SHOULD BE CONSIDERED IN THE SELECTION.
IMPROPER SELECTION OR USE OF PRODUCTS
DESCRIBED HEREIN CAN CAUSE PERSONAL INJURY
OR PROPERTY DAMAGE.

How to Order
PART NUMBER
PACKING
GP851211F8YL
PTFE
GP851212F8YL
Grafoil
Mounting kitOrder No. 800000K1 (page 8)
1.5 mounting bolts for Honeywell transmitter
(4 required) Order No. 095-0411-100

5Valve General Purpose ManifoldRemote Mount


Dimensions
Dimensions in inches (millimeters) are for reference only and are subject to change.
TO INSTRUMENT

VENT

VENT

PROCESS IN

Right side view

1.61
(41)

2.40 (61)

NPT vent
plugs
(supplied loose)

1.125 (28.6)
3.42 (87) open

Back view
Vent valve
(dustcap: red)

Isolate valve
(dustcap: blue)

0.31 (8) dia

3.00 (76.2)

2.36 (60)

1.6
(41 1
)

NPT outlet
connections

1.81 (46)
2.125 (54)

NPT inlet
connections

Top view

9.61 (244) open


FOR YOUR SAFETY

Equalize valve
(dustcap: green)

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM DESIGNER AND USER TO SELECT


PRODUCTS SUITABLE FOR THEIR SPECIFIC APPLICATION REQUIREMENTS AND TO ENSURE
PROPER INSTALLATION, OPERATION AND MAINTENANCE OF THESE PRODUCTS. MATERIAL
COMPATIBILITY, PRODUCT RATINGS AND APPLICATION DETAILS SHOULD BE CONSIDERED
IN THE SELECTION. IMPROPER SELECTION OR USE OF PRODUCTS DESCRIBED HEREIN CAN
CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.

How to Order
PART NUMBER
PACKING
GP853211F8YL
PTFE
GP853212F8YL
Grafoil
Mounting kitOrder No. 800000K2 (page 8)

HOKE Instrument Manifolds

General Purpose Manifold Mounting Kits


800000K1 For Direct Mount Models
Dimensions are in inches (millimeters) are for reference only and are subject to change.

10.5mm hole for


direct mounting
of (5) valve manifold
series GP8512 (2) req'd

ITEM

TITLE

MATERIAL

Bracket

SST 304

Clamp Plate

SST 304

U-Bolt

SST 316

Nut, Hex

SST

Washer, Lock

SST

ITEM

TITLE

MATERIAL

Bracket

SST 304

Clamp Plate

SST 304

U-Bolt

SST 316

8.5mm holes for


direct mounting of (2) & (3) valve
manifold series GP8212 & GP8312
1

2.60
(66)

1.18
(30)

4.92
(125)

2" pipe (2.375 OD)


REF
4

4.72
(120)

800000K2 For Remote Mount Models


Dimensions are in inches (millimeters) are for reference only and are subject to change.

4X 7mm wide slots for


remote mounting of
2-,3- and 5-valve manifolds
series GP8232, GP8332, and GP8532
3.78
(96)
2.36
(60)
1

3
2
1
(2" pipe, 2.375)

5.91
(150.1)
5

HOKE Instrument Manifolds

Nut, Hex

SST

Washer, Lock

SST

Trifold Needle Valve Manifold


The Hoke 3Valve Trifold manifold is designed for direct mounting to differential pressure transmitters having 2.125 inches (54
mm) center-to-center process connections.

Pipe by Flange
When direct coupling to orifice plate flanges is not desired, the pipe by flange Trifold Manifold allows for two NPT process
connections in addition to direct mounting of the transmitter.

Flange by Flange
When direct coupling to orifice plate flanges is required, the flange by flange Trifold Manifold mounts directly between the
flange and the transmitter. If direct coupling to orifice plate flanges is not required, process futbol connectors may also be used.

Features & Benefits

MAXIMUM
Dyna-Pak/Metal Stem Tip
OPERATING PRESSURE 6000 psig (414 barg) -65 F to +150 F
(-54C to +66 C)
3000 psig (307 barg) at +450 F (+232 C)
Graph-Lock/TFE Wafer Packing
5000 psig (345 barg) -60 F to +600 F
(-51C to +316 C)
3000 psig (307 barg) at +450 F (+232 C)
OPERATING
Dyna-Pak/Metal Stem Tip
TEMPERATURE RANGE -65 F to +450 F (-54C to +232 C)
Graph-Lock/TFE Wafer Packing
-60 F to +600 F (-51C to +316 C)

Purge ports are provided on the process side of


block valves for applications requiring continuous
purging.
Bleed or vent ports on the instrument side of the
block valves.
Dyna-Pak TFE or high-temperature 600 F (316 C)
Graph-lock/TFE wafer packing is standard.
Bonnet locks prevent accidental disengagement of
the bonnet.
Non-rotating hardened metal stem tip.
Integral backseats on all valve stems prevent
accidental removal.
Mounting bolts and TFE gaskets are standard.
Packing below stem threads prevents process
liquids from contaminating or washing away the
thread lubricants.
Special High Tolerance NPT Thread

Pressure Temperature Curves


PSIG (BARG)

6000 (414)
5000 (345)
4000 (276)
3000 (207)
2000 (138)
1000 (69)
0
-65
0
100
(-54) (-18) (38)

200 300 400 500 600


(93) (149) 204) (260) (316)

Fahrenheit (Celsius)
Dyna-Pak

Graph-lock/TFE

HOKE, Inc.
405 Centura Court PO Box 4866 (29305) Spartanburg, SC 29303
Phone (864) 574-7966 Fax (864) 587-5608
www.hoke.com sales@hoke.com

instrument manifolds

Technical Data

Trifold Needle Valve Manifold Pipe by Flange


Special Application Manifolds

Dimensions and Materials


Dimensions are in inches (millimeters) are for reference only and are subject to change
2.63
(66.8)
19

17
2.87
(72.9)
Open

18

16

13

0.59
(15.0)
1.02
(25.9)

15

15

8.10
(205.8)
Open
4.05
(102.9)
Open

1.69
(42.9)

DESCRIPTION

MATERIAL

HOUSING

316 stainless steel

PACKING NUT

316 stainless steel

LOCK NUT

316 stainless steel

WASHER

316 stainless steel

WAFER

PTFE tape

WASHER

316 stainless steel

SPACER

316 stainless steel

STEM

316 stainless steel

DISC

17-7PH stainless steel

10

STEM POINT

17-4PH stainless steel

11

WASHER

PTFE

12

SPRING PIN

302 stainless steel

13

MANIFOLD BLOCK

316 stainless steel

14

CAP SCREW

18-8 stainless steel

15

PIPE PLUG

316 stainless steel

16

SEAT INSERT

316 stainless steel

17

CAP LUG

Polyethylene

18

WASHER

304 stainless steel

19

HANDLE

316 stainless steel

2
3

PURGE

PURGE

BLEED

BLEED

3.75
(95.3)

2.43
(61.7)

4
7

1.71
(43.4)

Outlet

Outlet

2.125
(54)

11

10

3.38
(85.9)
2.63
(66.8)
Handle

INSTRUMENT PORTS

FOR YOUR SAFETY

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM DESIGNER AND USER


TO SELECT PRODUCTS SUITABLE FOR THEIR SPECIFIC APPLICATION
REQUIREMENTS AND TO ENSURE PROPER INSTALLATION, OPERATION AND
MAINTENANCE OF THESE PRODUCTS. MATERIAL COMPATIBILITY, PRODUCT
RATINGS AND APPLICATION DETAILS SHOULD BE CONSIDERED IN THE
SELECTION. IMPROPER SELECTION OR USE OF PRODUCTS DESCRIBED
HEREIN CAN CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.

BLEED/
PURGE

BLEED/
PURGE

1.19
(30.2)

15

NPT
NPT
PROCESS IN

11

2.88
(73.2)
3.67
(93.2)

12

1.80
(45.7)

0.42
(10.7)
316
6000 PSIG

How to Order Trifold Pipe by Flange


CONNECTIONS
PROCESS

INSTRUMENT

MODEL
NUMBER

STEM POINT

PACKING

1/2 Female NPT

Flange

8122F8Y

Non-rotating 17-4PH

Dyna-Pak

1/2 Female NPT

Flange

8128F8Y

Non-rotating 17-4PH

Graph-lock/
TFE wafers

Mani-Mount mounting module see page 17 for details (available for 8122F8Y only)

10 HOKE Instrument Manifolds

14

0.81
(20.6)
1.63
(41.4)
4.15
(105.4)
Open

1.32
(33.5)

Trifold Needle Valve Manifold Flange by Flange


Special Application Manifolds

Dimensions and Materials


Dimensions are in inches (millimeters) are for reference only and are subject to change
3.38
(85.7)

16
Inlet

2.13
(54.0)

Inlet

19
18

BLEED

BLEED

15

17
Outlet

Outlet

11

4.08
(103.6) Open

8.16
(207.2) Open

2.89
(73.4) Open
1.63
(41.3)
0.81
(20.6)

DESCRIPTION

MATERIAL

HOUSING

316 stainless steel

PACKING NUT

316 stainless steel

LOCK NUT

316 stainless steel

WASHER

316 stainless steel

WAFER

PTFE tape

WASHER

316 stainless steel

SPACER

316 stainless steel

STEM

316 stainless steel

DISC

17-7PH stainless steel

10

STEM POINT

17-4PH stainless steel

11

WASHER

PTFE

12

SPRING PIN

302 stainless steel

13

MANIFOLD BLOCK

316 stainless steel

14

CAP SCREW

18-8 stainless steel

15

PIPE PLUG

316 stainless steel

16

SEAT INSERT

316 stainless steel

17

CAP LUG

Polyethylene

18

WASHER

304 stainless steel

19

HANDLE

316 stainless steel

12

2
0.47 (11.9)

3
3.13
(79.4)

4
7

0.47 (11.9)

13

14

0.81
(20.6)
1.63
(41.3)

2.41
(61.1)

10

INSTRUMENT PORTS
BLEED/
PURGE

FOR YOUR SAFETY

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM DESIGNER


AND USER TO SELECT PRODUCTS SUITABLE FOR THEIR SPECIFIC
APPLICATION REQUIREMENTS AND TO ENSURE PROPER INSTALLATION,
OPERATION AND MAINTENANCE OF THESE PRODUCTS. MATERIAL
COMPATIBILITY, PRODUCT RATINGS AND APPLICATION DETAILS
SHOULD BE CONSIDERED IN THE SELECTION. IMPROPER SELECTION OR
USE OF PRODUCTS DESCRIBED HEREIN CAN CAUSE PERSONAL INJURY
OR PROPERTY DAMAGE.

BLEED/
PURGE

NPT
NPT
PROCESS IN

How to Order Trifold Flange by Flange


CONNECTIONS
PROCESS

INSTRUMENT

MODEL
NUMBER

STEM POINT

PACKING

Flange

Flange

8132YY

Non-rotating 17-4PH

Dyna-Pak

Flange

Flange

8138YY

Non-rotating 17-4PH

Graph-lock/
TFE wafers

7/16-20UNF-2B
4 holes

HOKE Instrument Manifolds

11

Rotofold Ball Valve Manifold


The Hoke Rotofold ball valve manifold has a unique design that utilizes quarter turn ball valves for blocking
process impulse lines and performing equalizing functions. They also provide easy rod though of all passages
when clean-out is necessary. PCTFE seats and PTFE stem packing are easily replaced if maintenance is required.
The pipe by flange Rotofold design allows the manifold to be directly mounted to integral orifice transmitters
by simply reversing the flanges and flange fittings. The pipe by pipe Rotofold design allows the manifold to be
remotely mounted separately from the process.

Features
ures & Benefits
Benefits

MAXIMUM
6000 psig (414 barg)
OPERATING PRESSURE -65 F to +150 F (-54C to +66 C)

Flange can be reversed for direct mounting to an


integral orifice type transmitter
Connections on instrument side of block valves for
bleeding and venting.
Replaceable PCTFE seats on all valves provide
longer service life.
All media passages can be rodded for easy
cleaning.
turn handle provides visual indication of valve
mode.
Mounting bolts and TFE gaskets are standard with
flange models.
Cam handles provide error-proof sequencing of
valves.
Mani-Mount mounting kit available for NPT pipe
style (see Mani-mount mounting system, page 17)
Special High Tolerance NPT Thread

400 psig @ +300 F (28 barg @ +149 C)


OPERATING
TEMPERATURE RANGE 0 F to +300 F (-18C to +149 C)

Pressure Temperature Curves


6000 (414)

PSI (BAR)

5000 (345)
4000 (276)
3000 (207)
2000 (138)
1000 (69)
0

0
50 100 150 200 250 300
(-18) (10) (38) (66) (93) (121) (149)

Fahrenheit (Celsius)

Cam-Valve Interlocking Sequencing Handles


The correct sequencing of opening and closing manifold valves
is critical to eliminating pressure transmitter damage due to over
ranging. By attaching cams to the equalizing and block valve handles,
the inter-locking design assures proper initial service and transmitter
zeroing during calibration.
Cam kit 8200K5 can be field installed or factory assembled to the
manifold at time of order. For factory assembled, add part number
8200K5 to the end of the manifold part number.

HOKE, Inc.
405 Centura Court PO Box 4866 (29305) Spartanburg, SC 29303
Phone (864) 574-7966 Fax (864) 587-5608
12 HOKE Instrument
Manifolds
www.hoke.com
sales@hoke.com

instrument manifolds

Technical Data

Rotofold Ball Valve Manifold - Pipe by Flange


Special Application Manifolds

Dimensions and Materials


Dimensions are in inches (millimeters) are for reference only and are subject to change
1

6
1

9
8

2.125
(53.98)

24

0.63
(16.0)

6
23

22

21

20
3

17

18

1.97
(50.0)
2.50
(63.5)

DESCRIPTION

MATERIAL

PLUG WASHER

PTFE

VENT FITTING

316 stainless steel

PIPE PLUG

316 stainless steel

316
6000 PSIG
8221F8Y14
1.25
(31.8)

WASHER

Viton

SEAT RETAINER

316 stainless steel

SEAT

PCTFE

BALL

316 stainless steel

INSERT

316 stainless steel

O-RING

Fluorelastomer

10

HANDLE

Aluminum alloy 360

11

STEM

316 stainless steel

12

RETAINING RING

PH15-7MO

13

STEM RETAINER

316 stainless steel

14

SHIM WASHER

316 stainless steel

15

SHIM WASHER

316 stainless steel

16

SHIM WASHER

PTFE

17

MANIFOLD BODY

316 stainless steel

18

SPIRAL PIN

302 stainless steel

19

CAP SCREW

Carbon Steel

20

RETAINING RING

302 stainless steel

21

FLANGE

Carbon Steel

22

FLANGE CONNECTOR

316 stainless steel

23

WASHER

PTFE

24

END FITTING

316 stainless steel

INSTRUMENT PORTS

19

BLEED/
PURGE

BLEED/
PURGE

NPT
NPT
PROCESS IN

Open

10

11

Outlet

Inlet

4.31
(109.5)

10

16

2.06
(52.3)

1.69
(43.0)
Outlet

15

Open

14

Closed

13

Rotofold

3.38
(85.9)

12

Inlet

10
51.6
(131.1)

How to Order Rotofold-Pipe by Flange


CONNECTIONS
BODY OUTLET STYLE

INLET PROCESS

OUTLET
INSTRUMENTATION

Flange

1/2 Female NPT

Flange

ORDERING
NUMBER
8221F8Y

Cam-valve sequencing handles order No. 8200K5


Mani-Mount mounting module - see page 17 for details (available
for 8221F8Y only)

FOR YOUR SAFETY

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM DESIGNER AND USER TO SELECT


PRODUCTS SUITABLE FOR THEIR SPECIFIC APPLICATION REQUIREMENTS AND TO ENSURE
PROPER INSTALLATION, OPERATION AND MAINTENANCE OF THESE PRODUCTS. MATERIAL
COMPATIBILITY, PRODUCT RATINGS AND APPLICATION DETAILS SHOULD BE CONSIDERED
IN THE SELECTION. IMPROPER SELECTION OR USE OF PRODUCTS DESCRIBED HEREIN CAN
CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.
HOKE Instrument Manifolds

13

Rotofold Ball Valve Manifold - Pipe by Pipe


Special Application Manifolds

Dimensions and Materials


Dimensions are in inches (millimeters) are for reference only and are subject to change
1

9
8

2.125
(53.98)

19

0.63
(16.0)

7
3

17

DESCRIPTION

MATERIAL

PLUG WASHER

PTFE

VENT FITTING

316 stainless steel

PIPE PLUG

316 stainless steel

18

WASHER

Viton

SEAT RETAINER

316 stainless steel

SEAT

PCTFE

BALL

316 stainless steel

INSERT

316 stainless steel

O-RING

Fluorelastomer

10

HANDLE

Aluminum alloy 360

11

STEM

316 stainless steel

12

RETAINING RING

PH15-7MO

13

STEM RETAINER

316 stainless steel

14

SHIM WASHER

316 stainless steel

15

SHIM WASHER

316 stainless steel

16

SHIM WASHER

PTFE

17

MANIFOLD BODY

316 stainless steel

18

SPIRAL PIN

302 stainless steel

19

END FITTING

316 stainless steel

2.65
(67.2)

6000 PSIG
8211F8Y

0.68 (17.2)

INSTRUMENT PORTS
BLEED/
PURGE

BLEED/
PURGE

10

12

OUTLET

13

14

16

INLET

CLOSED

11

OPEN

NPT
NPT
PROCESS IN

10

3.38
(85.7)

4.67
(118.7)

1.69
(42.9) OUTLET

INLET
OPEN

15

2.23
(56.6)

10

4.61
(117.1)

FOR YOUR SAFETY

How to Order Rotofold-Pipe by Pipe


CONNECTIONS
BODY OUTLET STYLE

INLET PROCESS

OUTLET INSTRUMENTATION

ORDERING
NUMBER

NPT Pipe

1/2 Female NPT

1/2 Female NPT

8211F8Y

Cam-valve sequencing handles order No. 8200K5


14 HOKE Instrument Manifolds

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM DESIGNER AND USER


TO SELECT PRODUCTS SUITABLE FOR THEIR SPECIFIC APPLICATION
REQUIREMENTS AND TO ENSURE PROPER INSTALLATION, OPERATION AND
MAINTENANCE OF THESE PRODUCTS. MATERIAL COMPATIBILITY, PRODUCT
RATINGS AND APPLICATION DETAILS SHOULD BE CONSIDERED IN THE
SELECTION. IMPROPER SELECTION OR USE OF PRODUCTS DESCRIBED HEREIN
CAN CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.

Pentafold 5Valve Manifold


The Hoke Pentafold 5-valve manifold is specifically designed for use with differential pressure transmitters when applied to gas
flow measurement. This manifold design uses two PCTFE seated ball valves and three needle valves with non-rotating PCTFE
stem tips as bypass or equalizing valves and vent valves. The two by-pass valves assure no leakage across the high and low side
of the orifice meter for critical gas flow measurement. The pipe by pipe Pentafold design allows the manifold to be mounted
away from the process but close to a differential pressure transmitter through the use of impulse piping.

Features & Benefits

MAXIMUM
6000 psig (414 barg)
OPERATING PRESSURE -20 F to +150 F (-29C to +66 C)

Static or vent ports provided on instrument side.


Replaceable ball seats and stem tips extend service
life, reducing cost.
Threaded mounting hole provided on all models.
Single manifold block has fewer potential leak
paths than individually assembled valves.
TFE standard packing in all valves.
Special High Tolerance NPT Thread

400 psig @ +300 F (28 barg @ +149 C)


OPERATING
TEMPERATURE RANGE 0 F to +300 F (-18C to +149 C)

Pressure Temperature Curves


6000 (414)

PSI (Bar)

5000 (345)
4000 (276)
3000 (207)
2000 (138)
1000 (69)
0

0
50 100 150 200 250 300
(-18) (10) (38) (66) (93) (121) (149)

Fahrenheit (Celsius)

HOKE, Inc.
405 Centura Court PO Box 4866 (29305) Spartanburg, SC 29303
Phone (864) 574-7966 Fax (864) 587-5608
www.hoke.com sales@hoke.com

instrument manifolds

Technical Data

Pentafold 5Valve Manifold


Special Application Manifolds

Dimensions and Materials


Dimensions are in inches (millimeters) are for reference only and are subject to change
1
22

4
2

0.62
(15.7)

Outlet

Inlet

2.13
(54.1)

25

Inlet

Outlet

1.00
(25.4)

DESCRIPTION

MATERIAL

WASHER

Fluorelastomer

SEAT RETAINER

316 stainless steel

SEAT

PCTFE

BALL

316 stainless steel

PLUG WASHER

PTFE

END FITTING

316 stainless steel

HANDLE

316 stainless steel

PACKING NUT

316 stainless steel

PACKING

PTFE

10

SPACER

316 stainless steel

11

HOUSING

316 stainless steel

12

SPINDLE

316 stainless steel

13

SEAT RETAINER

316 stainless steel

14

SEAT

PCTFE

15

STEM

316 stainless steel

16

RETAINING RING

Stainless steel

17

STEM RETAINER

316 stainless steel

18

SHIM WASHER

316 stainless steel

19

SHIM WASHER

316 stainless steel

20

SHIM WASHER

PTFE

21

HANDLE

Aluminum alloy 360

12
8
9
26

10

22

BODY

316 stainless steel

23

SEAT RETAINER

316 stainless steel

10

24

SEAT

PCTFE

11

25

SCREW

18-8 stainless steel

11

26

O-RING

Fluorelastomer

13

27

SPRING PIN

302 stainless steel

23

14

24
27

21
TO INSTRUMENT

VENT

VENT
3.38
(85.8)

7.06
(179.3)
Open

PROCESS IN

1.69
(42.9)

17

16

20
18
19

2.56
(65.0)

1.10
(27.9)

1.84
(46.7)
Open

2.75
(69.9)
4.56
(115.8)

How to Order Pentafold


FOR YOUR SAFETY
CONNECTIONS
INLET PROCESS

OUTLET INSTRUMENTATION

1/2 Female NPT

Flange

16 HOKE Instrument Manifolds

ORDERING NUMBER
8613F8Y

IT IS SOLELY THE RESPONSIBILITY OF THE SYSTEM DESIGNER AND USER TO SELECT PRODUCTS
SUITABLE FOR THEIR SPECIFIC APPLICATION REQUIREMENTS AND TO ENSURE PROPER INSTALLATION,
OPERATION AND MAINTENANCE OF THESE PRODUCTS. MATERIAL COMPATIBILITY, PRODUCT RATINGS
AND APPLICATION DETAILS SHOULD BE CONSIDERED IN THE SELECTION. IMPROPER SELECTION OR
USE OF PRODUCTS DESCRIBED HEREIN CAN CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.

Manifold Accessories
Mani-Mount Manifold Mounting System*
This installation method provides for rigid mounting of a Trifold
or Rotofold manifold to a 2 inch pipe stand instead of a differential pressure transmitter. Only the manifold is mounted during construction, which permits storage of the transmitter until
needed. The Mani-Mount not only provides a simple universal
mounting solution, but also converts the manifold to a single
flange design for direct mounting to the transmitter. The ManiMount can be used with any standard transmitter having 2 1/8
center to center process connections. Typical installation hardware costs are reduced because transmitter mounting brackets
are not necessary.
*Available for Special Application Trifold 8122F8Y and Rotofold 8221F8Y models only

Features & Benefits


Allows for rigid mounting of the manifold, instead of the
transmitter.
Simple universal mounting system for vertical, horizontal or
either side of 2 inch pipe stand.
Only the manifold needs to be mounted during construction;
the transmitter can be securely stored until final installation.
Transmitter mounting bracket is not necessary, reducing
costs.
Provides easy access to the transmitter by loosening 4 flange
bolts.
Fast installation process, saving time and money on costly
conventional installations.
Converts the manifold to a single flange style for direct
mounting to the transmitter cell.
Special High Tolerance NPT Thread

How to Order Kit*


PART NUMBER
8200K9
* manifold not included

17

Notes

Notes

Notes

CIRCOR Instrumentation Technologies (CIT) is the logical choice for fluid control solutions.
We provide the lowest cost of ownership, offering the best in class reliability and
availability of our products. We have global coverage, delivering value in the form of local,
flexible service to meet our customers needs. CIT is a product group specializing in
instrumentation with orifice sizes typically up to 2.

Our corporate head office and ISO 9001:2000 registered


manufacturing facilities are located at
405 Centura Court
Spartanburg, SC, USA, 29303
Tel +1-864-574-7966
Fax +1-864-587-5608
www.hoke.com
www.circortechnologies.com
Proudly Distributed By:

79011ENG 07/12 APS2036