DISUSUN OLEH
SANIA DANIATI
03121403059
Pompa-01 (P-01)
Pompa-02 (P-02)
Pompa-03 (P-03)
Pompa-04 (P-04)
Pompa-05 (P-05)
Pompa-06 (P-06)
Pompa-07 (P-07)
Pompa-08 (P-08)
Pompa-09 (P-09)
Pompa-10 (P-10)
Pompa-11 (P-11)
Pompa-12 (P-12)
Pompa-13 (P-13)
Pompa-14 (P-14)
Pompa-15 (P-15)
Pompa-16 (P-16)
Pompa-17 (P-17)
Pompa-18 (P-18)
Pompa-19 (P-19)
Pompa-20 (P-20)
Reaktor-01 (R-01)
Reaktor-02 (R-02)
Blower-01 (BL-01)
=1
=2
=1
=1
=2
= 2`
=1
=2
=1
=2
=1
=1
=2
=1
=1
= 1`
=1
=1
=1
=1
=4
= 24
=1
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
Hp
= 55
HP 41,0135 kW
2. Reaksi Elektrokimia
3. Pemanasan
4. Penerangan
Penerangan rata-rata untuk setiap bagian pabrik tidaklah sama, untuk
menghitung kebutuhan penerangan digunakan unit iluminansi SI yaitu lux
(symbol: lx). Lux adalah unit turunan berdasarkan lumen, dan lumen adalah unit
turunan berdasarkan candela.
1 lx = 1 lmm-2 = 1 cdsrm2.
Area
Hallway/Toilet
House lighting
Office lighting
Factory lighting.
Overcast day; typical TV studio
lighting
Type
candle
gas mantle
100 W tungsten incandescent (220 V)
200 W tungsten incandescent (220 V)
100 W tungsten glass halogen (220 V)
200 W tungsten glass halogen (220 V)
luminous
efficacy (lm/W)
0.3
12
13.8
15.2
16.7
17.6
19.8
5
12.6
17.5
19.2
24
35
white LED
10150
3050
4672
60
70100
80100
100
65115
85150
100200
251
683
LightEmitting
diode
Arc lamp
Fluorescent
Gas
discherge
Ideal
sources
LER)
Sumber : (SNI 03-6197-2000)
1) Penerangan pabrik :
= 60.000 m2
= 6 Ha
Tipe Lampu
= Lampu fluorescent
Intensitas Penerangan
= 400 lumen/m2
(SNI 03-6197-2000)
= 60.000 m2 x 400
lumen
m2
= 24.000.000 lumen
24.000.000 lumen
lumen
46
watt
= 521.739,1304 watt
= 521,7391 kW
2) Penerangan kantor:
Luas area kantor
= 1 Ha = 10.000 m2
Tipe Lampu
= Fluoroscent
Intensitas Penerangan
= 350 lumen/m2
(SNI 03-6197-2000)
= 10.000 m2 x 350
lumen
m2
= 3.500.000 lumen
Daya yang dibutuhkan
3.500.000 lumen
lumen
=
50
watt
= 70.000 watt