Anda di halaman 1dari 38

ELECTRIC DRIVES &

CONTROL
MANUAL

NAME- Punit kumar


REG. No.-13BEE0236

SLOT- L11+l2

3 INDUCTION MOTOR DC DYNAMIC BRAKING


Ex. No. 3

Date: 21/01/16

Aim
To detain the braking of 3 phase induction motor using DC dynamic braking.
NAME PLATE DETAILS:
a) 3 phase induction motor details and rating
(i)
Types of motor: Squirrel cage induction motor
(ii)

Voltage

: 415 V

(iii)

Current

: 1.3 A

(iv)

Speed

: 1440 rpm

(v)

Frequency : 50 Hz

Insulation : Class B

Apparatus Required:
S.No
1.
2.
3.
4.
5.

Apparatus
Induction motor
Ammeter
Voltmeter
Stopwatch
Rheostat

Range

Type

0-10 A
0-230 V

MC
MC

290 ohm/2.8 A

Quantity

1
1
1
1
1

Procedure:
1. Make the connection as per the circuit diagram .
2. Initially with switch being position A the working of induction motor is observed and supply
is switched off natural braking time is observed and noted.
3. At this point switch S is closed to B side ie applying DC voltage to the two terminals of stator
induction motor by disconnecting the AC supply.
4. Then the motor goes to braking region by decelerating and come to rest. Braking, time and
current are noted. The values are tabulated by considering different DC voltages.
TABULAR COLUMN:
S.No

Injected DC voltage

Deceleration time with DC

Braking current

braking

1.

25

3.34

0.6

2.

40

2.69

0.7

3.

60

2.17

0.9

4.

80

1.32

1.1

5.

100

1.19

1.3

4
_

3
AC
415 V

3 AC INDUCTION MOTOR WITH DYNAMIC BRAKING

U,

_
ACMoto
r

0 10 A
MC

V
V
W

+220

+0 220 V

290
DC 2.8A

Sup
_

MC
_

TPST

R
3
AC
415 V

Y
3
AC
415 V

Inference: In this braking for 3 phase induction motor ,decreasing the voltage results in a
decrease in the deceleration time. Current decreases as the deceleration time decreases.

Result: The braking of 3 phase induction motor has been obtained using DC dynamic braking.

DYNAMIC BRAKING OF DC MOTORS


Ex. No. 1

Date: 07/01/16

Aim
To study the type of braking experimentally applied to self excited DC motor.
1. Rheostat or dynamitic braking
NAME PLATE DETAILS:
Motor

Generator

Armature (field) voltage : 230 V


Armature current
: 1.8 A
Speed
: 1500 rpm
Power
: 0.37 kW

230 V
2.3 A
1500 rpm
0.37 kW

Apparatus Required:
SL. No
1.
2.
3.

4.
5.

Apparatus
D.C. motor
Ammeter
Rheostat

Range
0-10 A
750 ohm/10 A
290 ohm/2.8 A
100 ohm/10 A

Stopwatch
Tachometer

Type

Quantity

Self-excited
MC

1
1
1
1
1
1
1

Procedure:
Rheostat Braking:
1. Make the connection as per the circuit diagram.
2. The armature rheostat is kept at its maximum, field rheostat is kept at its minimum and
braking rheostat is kept at 50, 10A.
3. The switch is closed to A side and DC supply is given
4. By varying the armature rheostat, the speed of motor is set to 1000rpm with help of
tachometer.
5. Then the switch is moved from A side i.e. supply is disconnected to B side where braking
resistance is present in which generated energy is dissipated.
6. Thus motor comes to rest position after some time due to inertia and braking time is noted
through stop watch.
7. For different values of speed and also different values of braking resistances, results are
obtained and tabulated.

TABULAR COLUMN:
Speed and declaration time without braking:

S.No

Speed (RPM)

Deceleration time (sec)

1.

1110

1.45

2.

1200

1.76

3.

1270

1.9

TABULAR COLUMN:
Speed and declaration time with Rheostat Braking:

Deceleration
S.No

R()

Speed (RPM)

Braking time
(sec)

Braking
Current

1.

750

1140

0.86

0.1

2.

750

1200

1.07

0.12

3.

750

1250

1.00

0.14

4.

375

1135

0.83

0.24

5.

375

1200

0.72

0.24

6.

375

1200

0.84

0.26

RHEOSTATIC BRAKING

10

220 DC Supply

11

0 - 10 A MC

Inference: For a fixed resistance, as speed increases, deceleration time and current increase.
Result: Rheostat or dynamic braking has been experimentally applied to self excited DC motor.

12

PLUGGING OF DC MOTORS
Ex. No. 2

Date: 14/01/14

Aim :
To study the type of braking experimentally applied to self excited DC motor.
100 10A

750 10 A

1.Plugging or reverse voltage braking

NAME PLATE DETAILS:


Motor
Armature (field) voltage
Armature current
Speed
290 2.8A
Power

Generator

: 230 V
: 1.8 A
: 1500 rpm
: 0.37 kW

230 V
2.3 A
1500 rpm
0.37 kW

Apparatus Required:

SL . No
1.
2.
3.
4.
5.
M

Apparatus
D.C. motor
Ammeter
Rheostat

Range
0-10 A
750 ohm/10 A
290 ohm/2.8 A
100 ohm/10 A

Stopwatch
Tachometer

13

Type
Self-excited
MC

Quantity

1
1
1
1
1
1
1

A2

Procedure
PLUGGING:
1. Make the connection as per the circuit diagram.
A2

2. The armature rheostat is kept at its max, field rheostat is kept at its min and braking rheostat is
kept at 50
3. The switch is closed to A side and DC supply. is given
4. By varying the armature rheostat, the speed of motor is set to 1000rpm with help of
tachometer.
5. Then the switch
A2is moved from A side (i.e. supply is disconnected) to B side where dc supply is
reversed braking and resistance is present in which generated energy is dissipated.
6. Thus motor comes to rest position after some time due to inertia and braking time is noted
through stop watch.
7. For different values of speed and also different values of braking resistances, results are
Obtainedand tabulated
A1

A1

A1

14

F2

TABULAR COLUMN:

Speed and declaration time with Rheostat Plugging

S.No

R()

Speed (RPM)

Deceleration

Plugging

Plugging time (sec)

Current

1.

50

785

0.99

2.

50

900

1.05

5.2

3.

50
F1

1050

1.51

4.

25

810

1.00

5.

25

950

1.24

9.2

6.

25

1046

1.38

10

A2

15
A1

16

17

Inference:

In rheostat plugging, for a fixed resistance, as speed increases, current and

deceleration time increases.

PLUGGING

Result: Plugging or reverse voltage braking applied to self excited DC motor has been studied.

18

220 DC

FC 302 Initialisation via 14-22


Ex. No. 4

Date: 21/01/16

Aim:To reset the VLT Automation Drive FC 302 series to default values.
Apparatus Required:Sl. No.
1.

Apparatus
VLT Automation Drive FC 300

Range

Qty

240 Vac

2.

Design Guide

3.

Programming Guide

4.

Remote I/O Simulation Station

5.

PC (Optional)

6.

DVD Literature

Theory:The premier drive concept for exceptional control:


Designed for variable speed control of all asynchronous motors and permanent magnet motors, on any
industrial machine or production line, a VLT Automation Drive helps its owner save energy, increase
flexibility, and optimize processes.

VLT AutomationDrives are proven performers in all industrial environments and grid voltages, including
690V. Enclosures are available up to IP 66 (depending on model), and integrated DC chokes and RFI
filters in all models protect installations by minimizing harmonic distortion and electromagnetic
interferences.

All

drives

are

fully

tested

at

the

factory

before

they

are

shipped.

Easy to set up and operate via the user-friendly graphical control panel, a VLT AutomationDrive only
requires little maintenance once in operation. The result is an market leading control solution that
provides a fast return on investment and a highly competitive cost of ownership.

19

Fig:- VLT Automation drives


An integrated drive-motor solution:
The VLT Drive Motor FCM 300 Series is an integrated drive-motor solution which combines a VLT
frequency converter and a high standard quality motor in a single product.

Fig:- Integrated drive-motor

20

0 - 10 A MC

Fig:- Complete set up for experiment

Procedure:1. Press Main Menu


2. Scroll up/down to group 14-** (Special Functions)
3. Press [Ok]
4. Scroll up/down to 14-2* (Trip Reset)
5. Press [Ok]
6. Scroll up/down to 14-22 (Operation Mode)
7. Press [Ok]
8. Select Initialisation
9. Press [OK]
10. Disconnect the mains supply and wait until the display turns off
11. Reconnect the mains supply - the frequency converter is now reset.
12. Observe the message on the Local Control Panel (LCP)
Precautions:1. Do not touch the Power terminals on the FC 302. Voltage levels can be dangerous.
2. Be aware of rotating motor shaft.
Note:- Initialisation via 14-22 initialises all parameters except for:

14-50 RFI 1
8-30 Protocol
8-31 Address
8-32 Baud Rate
8-35 Minimum Response Delay

21

8-36 Max Response Delay


8-37 Max Inter-char Delay
15-00 to 15-05 Operating data
15-20 to 15-22 Historic log
15-30 to 15-32 Faultlog

Result: VLT Automation Drive FC 302 series to default values has been set.

22

50 10 A
100 10A

290 2.8A

INITIAL / BASIC COMMISSIONING


Ex. No. 5

Date: 28/01/16

Aim:Study and understand the initial commissioning using Quick Menu Button.
Apparatus Required:Sl. No.
1.

Apparatus
VLT Automation Drive FC 300

240 Vac

Range
1

Qty

2.

Design Guide

3.

Programming Guide

4.

Remote I/O Simulation Station

5.

PC (Optional)

6.

DVD Literature

Theory:The premier drive concept for exceptional control:


Designed for variable speed control of all asynchronous motors and permanent magnet motors, on any
industrial machine or production line, a VLT Automation Drive helps its owner save energy, increase
flexibility, and optimize processes.
VLT AutomationDrives are proven performers in all industrial environments and grid voltages, including
690V. Enclosures are available up to IP 66 (depending on model), and integrated DC chokes and RFI

23

A2

filters in all models protect installations by minimizing harmonic distortion and electromagnetic
interferences.

All

drives

are

fully

tested

at

the

factory

before

they

are

shipped.

Easy to set up and operate via the user-friendly graphical control panel, a VLT AutomationDrive only
requires little maintenance once in operation. The result is an market leading control solution that
provides a fast return on investment and a highly competitive cost of ownership.

A2

A2

Fig:- VLT Automation drives


An integrated drive-motor solution:
The VLT Drive Motor FCM 300 Series is an integrated drive-motor solution which combines a VLT
frequency converter and a high standard quality motor in a single product.

A1

24

A1

Fig:- Integrated drive-motor

A1

Fig:- Complete set up for experiment

Precautions:1. Do not touch the Power terminals on the FC 302. Voltage levels can be dangerous.
2. Be aware of rotating motor shaft.

F2

Example for open loop application with the above mentioned name plate ratings.

25
F1

A2

A1

26

Procedure:1. Press the Quick Menu Button.


2. Enter into the following Parameters inside the menu and press OK for setting the values.
i) Language in 0-01 and enter English.
ii) Motor Power in 1-20 and enter the value3.75KW.
iii) Motor Voltage in 1-22 and enter the value 240V.
iv) Motor Frequency in 1-23 and enter 50Hz.
v) Motor Current in 1-24 and enter 6.13A.
vi) Motor Nominal speed in 1-25 and enter 1500RPM.
vii) Terminal 27 Digit input in 5-12.
viii) Automatic motor adaptation in 1-29.
ix) Minimum reference speed in 3-02 and enter 150RPM.
x) Maximum reference speed in 3-03 and enter 1500RPM.
xi) Ramp1 up time in 3-41 and enter 3sec.
xii) Ramp1 down time in 3-42 and enter 3sec.
xiii) Reference site in 3-13.
3. Switch to [Hand On] operation.
4. Using the up/down/left/right navigation keys set the speed reference to 10% of the motor
synchronous speed (150rpm for 4 pole motor). The desired motor speed units (RPM or
Hz) can be adjusted from parameter 00-02.
5. Check if the motor is rotating. If not, check the Terminal 27 Digital Input setting
(Parameter- 05 Set to No operation mode). Check the direction of rotation and if it is of
opposite direction turn off the mains, wait for DC link to discharge and swap two of the
motor phases over by observing the usual safety procedures

OBSERVATION:

27

Result:

the initial commissioning using Quick Menu Button has been done.

Manual Initialisation three finger reset


28

Ex. No. 6

Date: 11/2/15

Aim:To reset the VLT Automation Drive FC 302 series to default values.
Apparatus Required:Sl. No.
1.

Apparatus
VLT Automation Drive FC 300

Range

Qty

240 Vac

2.

Design Guide

3.

Programming Guide

4.

Remote I/O Simulation Station

5.

PC (Optional)

6.

DVD Literature

Theory:The premier drive concept for exceptional control:


Designed for variable speed control of all asynchronous motors and permanent magnet motors, on any
industrial machine or production line, a VLT Automation Drive helps its owner save energy, increase
flexibility, and optimize processes.
VLT AutomationDrives are proven performers in all industrial environments and grid voltages, including
690V. Enclosures are available up to IP 66 (depending on model), and integrated DC chokes and RFI
filters in all models protect installations by minimizing harmonic distortion and electromagnetic
interferences.

All

drives

are

fully

tested

at

the

factory

before

they

are

shipped.

Easy to set up and operate via the user-friendly graphical control panel, a VLT AutomationDrive only
requires little maintenance once in operation. The result is an market leading control solution that
provides a fast return on investment and a highly competitive cost of ownership.

29

Fig:- VLT Automation drives


An integrated drive-motor solution:
The VLT Drive Motor FCM 300 Series is an integrated drive-motor solution which combines a VLT
frequency converter and a high standard quality motor in a single product.

Fig:- Integrated drive-motor

30

Fig:- Complete set up for experiment

Procedure:1. Disconnect from mains and wait until the display turns off.
2. Press [Status] - [Main Menu] - [OK] at the same time while power up for LCP
3. Release the keys after 5 s.
4. The frequency converter is now programmed according to default settings.
5. Observe the message on the Local Control Panel (LCP).

Precautions:3. Do not touch the Power terminals on the FC 302. Voltage levels can be dangerous.
4. Be aware of rotating motor shaft.
Note:Manual Initialization procedure initializes all parameters except for (examples below):

15-00 Operating Hours


15-03 Power-up's
15-04 Over temp's
15-05 Over volt's

31

Tips:1. If the LCP shows some Alarms this can be acknowledged & reset by pressing Reset key.
2. To be able reset Alarm 68 Safe Stop it is required a wire between terminals 12 & 37.
3. Adjust the brightness of the LCP at your preference
a) Press Status + Arrow Up to increase
b) Press Status + Arrow down to decrease
4. Use [Info] key located on LCP. It supplies information about a command, parameter, or
function in any display window. [Info] key provides detailed information whenever help is
needed. Exit info mode by pressing either [Info], [Back], or [Cancel]. See example below:
5. Go to 1-91 Motor External Fan & Press [Info] key. Scroll down.

6. The parameter shortcut can be carried out by holding down the [Main Menu] key for 3
seconds. The parameter shortcut allows direct access to any parameter. See example below:

32

Result: the VLT Automation Drive FC 302 series has been set to default values.

OBTAINING DRIVE INFORMATION


Ex. No. 6

Date: 18/02/16

Aim:To obtain information from the VLT Automation Drive FC 302


Apparatus Required:Sl. No.
1.

Apparatus
VLT Automation Drive FC 302

Range
240 Vac

2.

Design Guide

3.

Programming Guide

33

Qty

4.

Remote I/O Simulation Station

5.

PC (Optional)

6.

DVD Literature

Theory:The premier drive concept for exceptional control:


Designed for variable speed control of all asynchronous motors and permanent magnet motors, on any
industrial machine or production line, a VLT Automation Drive helps its owner save energy, increase
flexibility, and optimize processes.
VLT AutomationDrives are proven performers in all industrial environments and grid voltages, including
690V. Enclosures are available up to IP 66 (depending on model), and integrated DC chokes and RFI
filters in all models protect installations by minimizing harmonic distortion and electromagnetic
interferences.

All

drives

are

fully

tested

at

the

factory

before

they

are

shipped.

Easy to set up and operate via the user-friendly graphical control panel, a VLT AutomationDrive only
requires little maintenance once in operation. The result is an market leading control solution that
provides a fast return on investment and a highly competitive cost of ownership.

Fig:- VLT Automation drives

34

An integrated drive-motor solution:


The VLT Drive Motor FCM 300 Series is an integrated drive-motor solution which combines a VLT
frequency converter and a high standard quality motor in a single product.

Fig:- Integrated drive-motor

Fig:- Complete set up for experiment

Precautions:1. Do not touch the Power terminals on the FC 302. Voltage levels can be dangerous.
2. Be aware of rotating motor shaft.
Procedure:1.Press[Status]keyseveral timesuntil you get
thisscreen.

35

2. Press[MainMenu] key
3.Scroll down to 15-** Drive Information and press [Ok]key
4. Scroll down to 15-4* Drive Identification andpress [Ok]key
5. Scroll through Drive identification parameters and fill in data below.

1.15-40FCType - FC-302
2.15-41PowerSection P2K2:2.20KW
3.15-42Voltage -3380-500V
4.15-43SoftwareVersion- 0.731
5.15-44OrderedTypecode String -FC-302P2K2T5E20H2BG
6.15-45ActualTypecode String -FC-302P2K2TSE20H2BG
7.15-46FrequencyConverter OrderingNo -131B0068
8.15-47PowerCard OrderingNo - None
9.15-48LCPId No - Graphical V13
10.15-49SWIDControl Card - A07.31M08.L8D07.30
11.15-50SWIDPowerCard - SW:01.02EF:03.91
12.15-51Frequency Converter Serial Number - 156322G354
13.15-53PowerCard Serial Number - 130BC317983040G135

36

Result:The information from the VLT Automation Drive FC 302 has been
obtained.

37