Section
Page
1 LAPTOP SETUP:
SETUP Description
NOTE: If you have any problems with any steps of this MOP, DO NOT PROCEED,
Contact your PM immediately.
The Steps below need to be executed in the specified sequence on all impacted nodes.
login: admin
password: hidden
login: admin
password: hidden
1. Double click on the file msftpsrvr.exe to start the mini-sftp server program
on your PC.
2. Change these values on the mini-sftp-server as below
3. The user and password is TCU
4. Then click on start button to start the SFTP server
Connect an Ethernet cable from the PC LAN port to the Console port on the TCU
2.
3.
4.
rev
R1E01
R1T01
R1T01
uselocalsftp on
OSmon> startswsession
OperationSucceeded
OSmon>
downloadsw 1
sftp://TCU:TCU@192.168.1.2/2_19089_CXP102165_2XA/tcu02_sw.tar
5.
OperationSucceeded
OSmon> getswsessionstatus
DownloadInProgress
OperationSucceeded
When the software download is complete, activate the software using the following command:
OSmon> activatesw
OperationSucceeded
Check the software revision and verify that the primary software is the latest version and the
TCU is running on the primary application as follows:
6.
OSmon> rev
--------- Software modules --------cesopsn_pwr.chk
CXC 172 8394/4
p_relayr.chk
CXC 172 2708/4
snc.chk
CXC 112 3424/3
dhcpr.chk
CXC 172 9220/3
oam.chk
CXC 112 3423/4
profiler.chk
CXC 112 3517/3
sshdr.chk
CXC 172 2713/5
hdlc_pwr.chk
CXC 172 6448/4
secmgrr.chk
CXC 172 2710/5
telnetd.chk
CXC 172 2715/4
inetapps.chk
CXC 172 2851/4
sftpr.chk
CXC 172 2711/5
inetr.chk
CXC 172 9038/3
lcf_cp.chk
CXC 112 3683/3
bsp.drv
CXC 112 3427/4
bootstrap.chk
CXC 112 3428/4
loader.drv
CXC 112 3429/4
R1J02
R1J02
R1J02
R1L01
R2C01
R1J02
R1J02
R1J02
R1J02
R1J02
R1J02
R1J02
R2D01
R1J01
R2C01
R1L01
R1J02
R1E01
CXP102084_1
R2D01
R1T01