Anda di halaman 1dari 2

Unique, safe and

smart

&tech

ACV

ELECTRIC BOILER
& HOT WATER
GENERATOR

Thanks to its state-of-the-art technology,


ACVs E-Tech S is a unique electric boiler for
ACV offers reliable, powerful, cost effective
both domestic and commercial use, which
and environment-friendly solutions for most
provides the convenience of optimal heating
demanding applications in Domestic Hot Water
and high quality domestic hot water.
for both commercial and residential users.
E-Tech S is the intelligent boiler that stores
ACV has become a world leader distributing

energy when it costs less, and provides

engineered products in more than 40

convenience when you need it, helping you to

countries over 5 continents.

save both energy and money.


Moreover, ACVs E-tech S needs no oil or gas
PT. Surya Pratama Adirajasa
Casamora Square Blok BB 7, Jalan Sirsak, Moh. Kahfi I, Ciganjur
Jagakarsa, Jakarta Selatan 12630
TEL.: +62 21 2271 3822/23 - FAX: +62 2271 3823
Email : suryapratamaadirajasa.com
www.suryapratamaadirajasa.com
ACV International nv/sa
Kerkplein, 39
B-1601 RUISBROEK - BELGIUM
TEL.: +32 (0)2 334 82 20 - FAX: +32 (0)2 378 16 49
E-MAIL: international.info@acv-world.com
www.acv-world.com

supply: it can be installed anywhere in the house


or office building and operates silently!
And, to top it all, when you consider that it
also offers the benefits of the "Tank in Tank"

it is unique.

com 07/2002 - 67000800

maintenance free, you can see why

skeda

system, prevents lime build-up and is

STOCKIST

ACV accepts no responsibility whatsoever for any inaccuracy in transcribing or printing the present document.
ACV reserves the right to change the technical specifications and components of its products without prior notice.

excellence in hot water

SAFETY AND
RELIABILITY FEATURES
Maintenance free: none of the risk from lack of maintenance that there is with oil or gas
boilers.
Double switching system, with a redundant safety switch controlled by a maximum temperature
thermostat (103C).
Built-in Multiple Circuit Breaker (2 A) that protects the control circuit.
Low pressure safety switch connected to the redundant safety switch: if system pressure
drops below 0,5 bar, the boiler will shut down until the system is topped up.
Electro-mechanical devices are fail-safe components: there is no requirement for complicated
printed circuit boards or microprocessors.
Robust heating elements in stainless steel.
No requirement for a water flow switch.

&tech

Tank in Tank large exchange surface

Self-descaling

The DHW tank of the E-tech S is made of stainless steel.


It constitutes the inner tank of the Tank in Tank generator,
which is completely immersed in the primary fluid of the
heating circuit.
Its large heat exchange surface (typically 1.5 to 2.5 times
more than a traditional coil) allows a large quantity of
domestic hot water to be heated in an exceptionally short
time.
Thanks to the rapid heating of the domestic hot water,
the stored volume can be reduced and energy losses
minimised.

The E-tech S domestic hot water tank is free to expand


and contract as a result of the variations in pressure
which occur with every draw-off and during each heating
cycle. Besides, the corrugation of the tank over its entire
length amplifies this movement and prevents the formation
of lime on the surface of the exchanger. This is one of
the main strengths of ACV Tank in Tank generators.

Anti-legionellae

Thanks to the large thermal exchange surface of the tank,


which is completely immersed, the domestic hot water
can be maintained at a uniform temperature of at least
Stainless steel tank
60C, which prevents the formation of legionellae and
Stainless steel, coupled with the know-how of ACV, provides other bacterial proliferation. Finally, the E-tech S needs
the DHW tank with exceptional strength against water
no protection anode, a device that could also lead to
and corrosion attacks.
bacterial growth.

MAXIMUM CONVENIENCE IN
ENERGY STORAGE
Boiler Temperature (C)

No maintenance

The E-tech S is thermally insulated over its whole surface


by 70 mm injected polyurethane. The polyurethane used
is the opened cell type with a very low coefficient of
thermal conductivity (= 0.033 W/m.K), which minimises
the static heat loss to less than 3C in 8 hours (with a
storage temperature of 85 C).

Thanks to its stainless steel tank, the E-tech S requires


no protection anode. Besides, its anti-scaling feature
eliminates the need for regular descaling. Therefore, the
E-tech S is entirely maintenance-free: the pleasure of hot
water comfort with nothing to worry about.

READY TO INSTALL:
NO ADDITIONAL PARTS NEEDED
All-inclusive boiler:
- expansion vessel
- temperature and pressure
relief valve
- manothermometer
- circulation pump
- water pressure switch
all inside the boiler casing.

Easy to use and extremely convenient


Safety features

WHEN TO
CHOOSE THE
E-TECH S

Lower energy costs

the upper temperature is adjustable and controls ignition of the first power
stage
the lower temperature is automatically set at 7C below upper temperature
and controls ignition of the second power stage
Thanks to this simple but effective modulation feature, the E-Tech S has long
working cycles and requires less starts and stops: this results in a longer
lifetime and less disruption through the electricity grid.

Input
Voltage
Heating elements
Total capacity
Domestic Hot Water Capacity
Exchange surface
Max. Operating pressure (DHW)
Max. Operating pressure (Primary)
Built-in expansion vessel
Max operating temperature
Heating connections
DHW connections

kW
V
nr.
L
L
m2
bar
bar

Domestic Hot Water performance

(DHW)

Peak flow at 40 C
Peak flow at 40 C

L/10
L/60

E-Tech S
240

E-Tech S
290

E-Tech
380

21.6
3x400+N
6
161
106
1.26
10
3
1x8 L
85
4/4
3/4

28.8
3x400+N
6
242
174
1.87
10
3
1x8 L
85
4/4
3/4

28.8
3x400+N
7
295
198
2
10
3
2x8 L
85
4/4
4/4

28.8
3x400+N
7
394
267
2.6
10
3
2x8 L
85
4/4
6/4

E-Tech S is ideal for renovated historical


buildings without a chimney.

(Water supply at 10 C - Operating temperature at 80 C)


356
873

545
1234

676
1365

875
1564

In office blocks the E-Tech S avoids gas


or oil pipes inside the building.

Night and Day

85 C

Night position - The boiler works at maximum power and stores water at
temperature set by control thermostat.
60 C
0

Circulation
pump
(room
thermostat)

E-Tech S
160

Day position - The boiler must be kept above minimum temperature (60C).
If temperature drops below 60C, the boiler works at reduced power.
Switching from day to night position - A contact in the control board must
be open to switch to day position. It can be controlled by a clock, a boiler
control, an external signal, etc.

Booster function - A push button on the panel forces the boiler to night
position for 1 hour in case of high heating demand during the day

Electricity
consumption 1

DIMENSIONS
A
B
C
D
E
Weight

mm
mm
mm
mm
mm
Kg

160

240

290

380

1432
620
720
1282
290
115

1953
620
720
1800
290
155

1784
720
800
1627
300
202

2134
720
800
1985
300
230

The E-Tech S offers domestic hot


water comfort combined with intelligent
heating features.

0
07h00

22h00

INSTALLATION
FLEXIBILITY
Three choices for heating
connections.
The boiler can be installed:
against the wall
in a corner facing left
in a corner facing right

OPTIONS
HEATING CONTROL SYSTEM
E-Tech S boilers can be equipped with dedicated control
systems that make it very easy and effective to control
several heating circuits, including floor-heating. Ask your
installer to advise you on the best solution for your needs.
THERMOSTATIC MIXING VALVE
ACV recommends using a thermostatic mixing valve to
eliminate the risk of scalding.

In case of remote location the E-Tech S


combines the advantages of an electrical
boiler with a high performance DHW
strorage tank.

RAN
AR

TY

1. Domestic Hot
Water connections
2. Heating flow
3. Expansion vessels
4. Inner tank in
stainless steel
5. Drain valve
6. Heating elements
7. Dry well
8. Heating return
9. Primary tank
insulated with
70 mm rigid
polyurethane foam
10. Safety valve 3 bar
11. Water pressure
switch

Zero maintenance costs

Model

Built-in power modulation


The dual-stage boiler thermostat (60 85C) controls ignition of the 2
power stages of the boiler:

T C

Optimal insulation

THE ACV TANK IN TANK SYSTEM:


HIGH QUALITY DOMESTIC HOT WATER

&tech

no oil/gas supply

TECHNICAL DATA

Power (kW)

FEATURES

Lower installation costs: no chimney,

EARS

BOILER
BODY

Anda mungkin juga menyukai