Qair = Qwater
Reference temperature = 00C
[a2ha2 - a1ha1] + [s2hs2 - s1hs1] + g[l2(a2 +s2) l1(a1 + s1)] = (w2hw2 - w1hw1) + g(l2w2
l1w1)
Qair =0.0326+0.0144+0.00009539=0.0471 kW
3
2.13 10 m ,
w2 = V = 1000kg/m (
60 s
3
= 0.0355kg/s
w1 = w2 +
d V tank
dt
= 0.2155kW
g(l2w2 l1w1) = 9.8(0.6(0.0355) 0)
= 2.087 10-4kW
Therefore,
Qwater =0.2155+0.0002087=0.2158 kW
Qwater 0.0471 kW
=
=0.2183
Qair 0.2158 kW