Anda di halaman 1dari 16

Project Highlights

Cooling Tower

Analogue Technical Agencies Ltd. (ATAL) is the sole distributor of Evapco on evaporative cooling
products in Hong Kong & Macau. We have a team of professional & factory-trained sales and engineers to provide one-stop solution from design, equipment selection, installation, testing & commissioning to maintenance.
Evapco is a US based and world-wide market leader on evaporative cooling equipment with manufacturing facilities in both Shanghai and Beijing. In addition to CTI certification on the products,
Evapco offers 100% thermal guarantee to all products they manufactured.
Our products include:
Induced and Forced Draft Cooling Tower
Open and Close Type Cooling Tower
Evaporative Condenser
Industrial Field Erected Cooling Tower
Evaporator in Refrigeration

Cooling Tower
Closed Circult Cooler

Cooling Tower
Induced Draft

Cooling Tower
Forced Draft

i- SQUARE
Project Description:

A massive shopping and entertainment


complex developed by Associated International Hotels Ltd. This is another important shopping center located in the heart
of Tsim Sha Tsui between Nathan Road and
Peking Road with the challenge of delivery
restriction at Nathan Road. Our delivery and
installation work were only allowed at overnight time because of busy traffic at Nathan
Road. We only used two over nights to finish
all the cooling towers delivery and assembly
work. Factory pre-assembly design is our key
success in this project.

Equipment Description:

We provided 4 nos. of AT 112-720 and 1 no.


of AT 19-88 single cell hot dipped galvanized
steel construction cooling tower.
Association International Hotels Ltd.
Meinhardt (M&E) Ltd.
June 2010

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Evaporative Condenser

Cooling Tower
Evaporative Condenser

Cooling Tower
Forced Draft

Cooling Tower
Induced Draft

City of Dream, Macau


Project Description:

This is one of the major casino and resort


located in the heart of Cotai, Macau. The
central chiller plant provided 32,000 refrigerant tons for whole development which included 3 hotels, casino, theaters and shopping mall. Since the cooling tower plant
was located closed to a hotel. We offered
32 nos. of super low noise fan in 8 groups
providing 40,000 tons heat rejection. We
finished all installation within 3 months only.

Equipment Description:

We provided 8 nos. of AT 428-1148 4 cells


hot-dipped galvanized steel construction
with Super Low Noise Fan cooling tower.
Melco Crown Entertainment Ltd.
J. Roger Preston Ltd.
November 2008

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Closed Circult Cooler

Cooling Tower
Closed Circult Cooler

Cooling Tower
Induced Draft

Cooling Tower
Forced Draft

Cooling Tower
Evaporative Condenser

Cooling Tower
Evaporative Condenser

Cooling Tower
Forced Draft

Cooling Tower
Induced Draft

Cooling Tower
Closed Circult Cooler

The ONE
Project Description:

This is the major shopping mail with 400,000 square feet located at Nathan Road
and the center of Tsim Sha Tsui. The ONE is designed to cater to a diverse and sophisticated tenant mix, presenting an enticing assortment to shoppers in pursuit of
quality of life. In a narrow space, we provided 5,500 heat rejection ton for chiller
plant. Each cooling tower constructed with double cells design to fill the limited
space and height challenge.

Equipment Description:

We provided 5 nos. of AT 220-518 double cells hot dipped galvanized steel construction cooling tower.
Chinese Estates Holdings Ltd.
Meinhardt (M&E) Ltd.
April 2010

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Closed Circult Cooler

Cooling Tower
Induced Draft

Cooling Tower
Forced Draft

The Masterpiece
Project Description:

A high-rise mixed redevelopment with Urban


Redevelopment Authority. It changed from
old district into the modern high-rise commercial building. It contained not only the
shopping mall and hotel, but also with the
apartment and art gallery. All the cooling
towers made by stainless steel 316 in USA.
The total heat rejection capacity reached
5500 ton.

Equipment Description:

We provided 4 nos. of AT 112-018, 4 nos. AT


19-99 and 1 no. of AT 19-86 single cell stainless steel 316 construction cooling tower.
New World Development Co. Ltd.
Meinhardt (M&E) Ltd.
June 2008

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Evaporative Condenser

Cooling Tower
Evaporative Condenser

Cooling Tower
Forced Draft

Cooling Tower
Induced Draft

Cityplaza One Office


Project Description:

The skyscrapers located at Cityplaza, one


major icon of residential, commercial and
shopping mall in Hong Kong Island. The office building already operated over 15
years. It is the time to replace the inefficient
old air cooled system into efficient water
cooled system. The challenge of this project
is to locate the cooling towers into the same
footprint and height as old air-cooled chiller.
We employed the Evapco forced draft low
profile type cooling tower to meet it. Our
cooling towers provided full capacity and
not exceed height limit to the building. We
achieved the total heat rejection in 2,000
tons for the chillers.

Equipment Description:

We provided 4 nos. of LPT 8212 and 1 no. of


LPT 8312 hot dipped galvanized steel construction cooling tower.
Swire Properties Ltd.
Talent M&E Engineers Ltd.
August 2009

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Closed Circult Cooler

Cooling Tower
Closed Circult Cooler

Cooling Tower
Induced Draft

Cooling Tower
Forced Draft

Landmark East
Project Description:

This is the 1.37 million square-feet Grade A


office with 35,000 square feet landscaped
garden designed by award-winning US architecture firm Arquitectonica. With the
Evapco counter flow induced draft design,
the optimum size of cooling towers fulfilled
the total 6,600 heat rejection tons the chiller
plant. It combined different size of cooling
towers to meet the challenge of elliptic plant
area and heat rejection requirement.

Equipment Description:

We provided 7 nos. of AT 112-212, 4 nos. of


AT 212-024 and 3 nos. of AT 19-88 stainless
steel 304 construction cooling tower.
Winsor Properties Holdings Ltd.
Thomas Anderson & Partners (HK) Ltd.
October 2008

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Evaporative Condenser

Cooling Tower
Evaporative Condenser

Cooling Tower
Forced Draft

Cooling Tower
Induced Draft

W Square
Project Description:

This is the ex-East Asia Bank building at


the Hennessy road Wan Chai. The building was retrofitted and designed in using
water cooled VRV system. With Evapco
designed closed circuit loop condensing
water cooling tower, it provided clean
and low temperature condensing water to
the VRV condenser for heat rejection. The
benefit of closed loop type can eliminate
the dust and dirt from the air go into the
water. The polluted water caused the water-cooled VRV condenser clog and malfunction. Hence, the maximum efficiency
of water-cooled VRV can be performed.

Equipment Description:

We provided 1 no. of ATW 102-5L and 1 no.


of ATW 204-5L in stainless steel 304 water
basins and hot dipped galvanized steel
casing construction closed circuit cooler.
Wing Tai Asia Enterprises
Thomas Anderson & Partners (HK) Ltd.
November 2008

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Closed Circult Cooler

Cooling Tower
Closed Circult Cooler

Cooling Tower
Induced Draft

Cooling Tower
Forced Draft

The United Christian Hospital


Project Description:

This is the major hospital in Kowloon East


Cluster. Since residential estate is close
to the hospital, the consultant employed
forced draft design to overcome the intake
and discharge duct silencer pressure drop.
Moreover, the closed typed cooling tower
design can provide a certain heat rejection
once the hospital is out of city water. It works
as air cooled condenser in case no city water supply. Such heat rejection can maintain
the emergency heat rejection for the chillers
in hospital. On one hand, the hospital can
enjoy the high efficiency from water cooled
system most of the time. On the other hand,
the closed type cooling tower can keep the
emergency chiller function in case out of
city water.

Equipment Description:

We provided 4 nos. LSWA 232B hot dipped


galvanized steel construction closed circuit
cooling tower. All the units were made in
USA.
The Hong Kong Hospital Authority/ United
Christian Hospital
EMSD/ Parsons Brinckerhoff (Asia) Ltd.
May 2008

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Evaporative Condenser

Cooling Tower
Evaporative Condenser

Cooling Tower
Forced Draft

Cooling Tower
Induced Draft

NT South Police HQ, Tusen Wan


Project Description:

This is our first model of cooling towers that meet


with all the requirements from the code of practice for water-cooled air conditioning systems
in Hong Kong. We demonstrated the cooling
tower in low drift rate (0.001%), tight inlet louver design (no sunlight goes into the tower and
water splash out) and easy maintenance with
belt driven design. Our stainless steel 316 casing material design demonstrating the market
a cooling tower with rigid and easy to clean
concept.

Equipment Description:

We provided 4 nos. AT 112-518 stainless steel 316


construction induced draft cooling tower. This is
also the first lot of cooling towers using stainless
steel 316 that made in PRC.
HKSAR/ ASD
EMSD/ Parsons Brinckarhoff (Asia) Ltd.
October 2005

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Closed Circult Cooler

Cooling Tower
Closed Circult Cooler

Cooling Tower
Induced Draft

Cooling Tower
Forced Draft

Shek Wu Hui Municipal Services


Building
Project Description:

This is a special project that the cooling towers


were totally enclosed in a building. The cooling
tower shall overcome the pressure drop from
intake small opening louver and discharge
duct work. The Evapco centrifugal fan forced
draft type cooling tower providing sufficient
static pressure for this project. It demonstrated
the ability of forced draft cooling tower that
the induced draft cannot perform.

Equipment Description:

We provided 2 nos. LPT 559 with stainless steel


304 basin and hot dipped galvanized steel
casing construction cooling tower.
HKSAR / ASD
EMSD/ Hyder Consulting Ltd.
February 2006

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Evaporative Condenser

Cooling Tower
Evaporative Condenser

Cooling Tower
Forced Draft

Cooling Tower
Induced Draft

EMSD Headquarters
Project Description:

Hong Kong Government had the role in promoting and leading the energy saving. Evapco provided an evaporative condenser which
removes all the heat from ice making chiller directly. Ice making chiller made the ice at night
time. Ice melted and helped to provide chilled
water at daytime. The ice transfers the heat
load from daytime to night time, hence to reduce the size of chiller to overcome the peak
heat load. If the electric fee is low at night time,
the high electric fee charge at daytime can
be shifted to the night time through the ice.
The Evapco evaporative condenser cooled
down the chiller refrigerant directly, hence
provided maximum efficiency to the chiller.

Equipment Description:

We provided 4 nos. of LSCB 386 hot dipped


galvanized steel construction evaporative
condenser.
HKSAR/ EMSD
EMSD
2004

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Closed Circult Cooler

Cooling Tower
Closed Circult Cooler

Cooling Tower
Induced Draft

Cooling Tower
Forced Draft

ST. Teresa Hospital


Project Description:

This is a famous Catholic private hospital located at Kowloon City over 60 years. There are
some residential apartments around the hospital. Sound is the next concern other than the
heat rejection for chillers. We selected a low
speed cooling tower that provided the satisfaction acoustic performance in full operation
at night time. We concern not only the energy
saving in using water cooled system as environmental protection, but also concern the sound
effect.

Equipment Description:

We provided 4 nos. AT 112-012 stainless steel


304 construction induced draft cooling tower.
St. Teresa Hospital
Parsons Brinckarhoff (Asia) Ltd.
August 2007

Developer/ Owner:
M&E Consultant:
Completion Date:

Cooling Tower
Evaporative Condenser

ATAL Building Services Engineering Ltd. provides total solution from design, installation, testing,
commissioning to maintenance and operation of full spectrum of building services works,
including MVAC, Electrical, Fire, Plumbing & Drainage, ELV, Energy Management, Control and
Building Management Systems for building and infrastructure development projects. We offer a
wide range of intelligent and green building solutions include:
AudioVisual & Communication
Building Management & Control
Efficient HVAC Solution
Electrical Systems
ELV & Security
Energy Management
Lighting Solution
Renewable Energy
Thermal Storage

ATAL BUILDING SERVICES ENGINEERING LTD


13/F, Island Place Tower, No. 510 Kings Road, North Point, Hong Kong
Tel: 2565 3399 Fax: 2562 6401 Email: atalbs@atalbs.com.hk