Anda di halaman 1dari 5
EHAF 100 -ELECTRIC TRACTION ELEVATORS SECTION 142100 - ELECTRIC TRACTION ELEVATORS, RESIDENTIAL MARINA RES-28| “Technical Specfnon Rev 00 2100-1 EHAF M0100 ~ ELECTRIC TRACTION ELEVATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS ‘A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section, 12 SUMMARY ‘A. Drawings and General Provisions of contract including general and special conditions and general requirements shall apply to work of this section. This section details the performance specification for the lift installation, associated control, and auxiliary equipment, B. The finish for lift cars, landing door/fixtures, architraves, transom panels, etc. are described generally in this Specification, unless it is separately shown on the drawings or described in the particular Specification. The stainless steel finished as specified shall have a minimum standard thickness of not less than 1.5 mm or as specified in the technical submission and approved by the engineer. Construction and installation details for various applications shall be submitted to the Engineer for approval prior to ‘commencement of work C.. The Contractor shall take into account of the maximum loading of car internal finishes for each of the lifts (including false ceiling, wall panels, flooring, lighting fixtures and the like) when proposing the equipment for the Lift Installation, As a general guidance, the loading of internal finishes shall not be less than 30% (unless, otherwise specified) of the lift rated capacity D. Exact provision shall be submitted for Engineer's approval prior to construction. The type, quantity, capecity, speed of lifts shall be as described and as shown on the Drawings. E. Related Requirements: 1. Section 015000 "Temporary Facilities and Controls” for temporary use of elevators for construction purposes. 2. Section 033000 "Cast-In-Place Concrete” for setting sleeves, inserts, and anchoring devices in concrete 3. Section 042200 “Unit Masonry Assemblies" for setting sleeves, inserts, and anchoring devices in masonry and for grouting elevator entrance frames installed in masonry walls. 4, Section 051200 "Structural Stee!" for the following: a) Attachment plates, angle brackets, and other preparation of structural stee! for fastening guide-rail brackets. b) Divider beams. ©) Hoist beams. 5. Section 055000 "Metal Fabrications" for the following: [RESIDENTIAL MARINA RES.2¢ ‘esha Speieston Rev. 00 ai00-2 EHAF 142100 — ELECTRIC TRACTION ELEVATORS 14 1s ) Attachment plates and angle brackets for supporting guide-rail brackets. b) Divider beams ©) Hoist beams 4) Structural-stee! shapes for subsills ©) Cants in hoistways made from steel sheet 6 Section 096340 “Stone Flooring” for fi ish flooring in elevator cars. REFERENCES A. BS476 Fire tests on building materials and structures BL BS 5655 (EN 81) Lifts and service lifts Cc. BS 5656 (EN 115) Safety rules for the construction and installation of Escalators and passenger conveyors D. BS6977 Insulated flexible cables for lifts and for other flexible Connections E. BS 7255 Code of practice for safe working in lifts F. BSEN9000 Quality management and assurance standards G. Qatar Construction Specification, Section 21, Part 20 (Elevators / Escalators) Ministry of Electricity and Water Regulations (KAHRAMAA) for passenger and goods lifts DEFINITIONS ‘A. Definitions in EN11S apply to work ofthis Section. B. Service Elevator: A passenger elevator that is also used to carry freight, ACTION SUBMITTALS ‘A. Product Data: Include capacities, sizes, performances, operations, safety features, finishes, and similar information. Include product data for car enclosures, hoistway entrances, and operation, control and signal systems. B. Shop Drawings: 1. Include plans, elevations, sections, and large-scale details indicating service at each landing, machine room layout, coordination with building structure, relationships with other construction, and locations of equipment, 2. Indicate maximum dynamic and static loads imposed on building structure at points of support, and maximum and average power demands, C._ Samples for Initial Selection: For finishes involving color selection, RESIDENTIAL MARINA RES-24 Teshucal Spcifcaton~Rev (0 142100-3, EHAF 142100 ELECTRIC TRACTION ELEVATORS 17 18 D. Samples for Verification: For exposed car, hoistway door and frame, and signal equipment finishes; 75-mm- square Samples of sheet materials; and_100-mm lengths of running trim members. E. Include sample proposed for flooring mentioned in another section (Stone flooring). INFORMATIONAL SUBMITTALS, ‘A. Qualification Data: For Installer. B, Manufacturer Certificates: Signed by elevator manufacturer certifying that hoistway, pit, and machine room layout and dimensions, as shown on Drawings, and electrical service, as shown and specified, are adequate for elevator system being provided, C. Sample Warranty: For special warranty ‘CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: For elevators to include in emergency, operation, and ‘maintenance manuals, 1. In addition to items specified in Section 01782 "Operation and Maintenance Data,” include diagnostic and repair information available to manufacturer's and Installer's maintenance personnel. B. Inspection and Acceptance Certificates and Operating Permits: As required by authorities having jurisdiction for normal, unrestricted elevator use, C. Continuing Maintenance Proposal: Submit a continuing maintenance proposal from Installer to Owner, in the form of a standard 400 days maintenance period, starting on date initial maintenance service is concluded. State services, obligations, con and terms for agreement period and for future renewal options. QUALITY ASSURANCE ‘A. Installer Qualifications: Elevator manufacturer or an authorized representative who is trained and approved by manufacturer. DELIVERY, STORAGE, AND HANDLING ‘A. Deliver, store, and handle materials, components, and equipment in manufacturer's protective packaging. Store materials, components, and equipment off of ground, under cover, and in a dry location, COORDINATION A. Coordinate installation of sleeves, block outs, elevator equipment with integral anchors, ‘and other items that are embedded in concrete or masonry for elevator equipment Furnish templates, sleeves, elevator equipment with integral anchors, and installation instructions and deliver to Project site in time for installation. B. Coordinate locations and dimensions of other work relating to electric traction ‘elevators; entrance subsills; electrical service; and electrical outlets, lights, and switches in hoist ways, pits, and machine rooms. RESIDENTIAL MARINA RES.24 “esha Speieation ~Rev. 00 EHAF 142100 ELECTRIC TRACTION ELEVATORS WARRANTY A Manufacturer's Special Warranty: Manufacturer agrees to repair, restore, or replace ‘elevator work that fails in materials or workmanship within specified warranty period, 1. Failures include, but are not limited to, operation or control system failure, including excessive malfunctions; performances below specified ratings: ‘excessive wear, unusual deterioration or aging of materials or finishes; unsafe ‘conditions; need for excessive maintenance; abnormal noise or vibration; and similar unusual, unexpected, and unsatisfactory conditions. Warranty Period: 10 years from date of Substantial Completion. PART 2- PRODUCTS 21 MANUFACTURERS ‘A. Subject to compliance with requirements, provide products by one of the manufacturers, included in Annexure B, “VENDORS’ LIST” of Volume One “Tender Particulars” of the Tender Documents. B. Source Limitations: Obtain elevators from single manufacturer. 1. Major elevator components, including driving machines, controllers, signal fixtures, door operators, car frames, cars, and entrances, shall be manufactured by single manufacturer. 22 PERFORMANCE REQUIREMENTS ‘A. Regulatory Requirements: Comply with EN-81 23. ELEVATORS ‘A. Elevator System, General: Manufacturer's standard elevator systems. Unless otherwise indicated, manufacturer's standard components shall be used, as included in standard ‘elevator systems and as required for complete system. B. Subject to compliance with requirements provide the following Elevators: PASSENGER TOWER ELEVATORS LIFTS SN Tem Description | Passenger Elevator i Quantity s 2 Type Machine Room 3 Capacity 15 Persons (1000 Kg) 4 Speed 4mis Variable Voltage Variable Frequency Drive 5 Drive System (VWVF), Gearless with Permanent Magnet Synchro- _| nous Motor with two independent brake system _| 6 ‘Stops/Entrances 28 stops /28 opening, All in same line 7 Landing Denomination ‘As per drawings 8 Control Duplex Selective Collective Control 9 Travel (Mts 108.80 Meters 10 Carinternal size in mm Té00mm Wx 1400mm D x 2300mm H. i ‘Car Interior ‘Car Walls Etched finished stainless stee! from manu ‘RESIDENTIAL MARINA RES.24 Technical Speifeation Rev. 00 2100-5

Anda mungkin juga menyukai