KOMPETENSI 1\
11/03/2016 02:04:39 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
OB1 - <offline>
""
Name:
Author:
Family:
Version: 0.1
Block version: 2
11/03/2016 02:01:48 PM
Time stamp Code:
02/15/1996 04:51:12 PM
Interface:
Lengths (block/logic/data): 01158 00946 00020
Name
Data Type
TEMP
Address
Comment
0.0
OB1_EV_CLASS
Byte
0.0
OB1_SCAN_1
Byte
1.0
OB1_PRIORITY
Byte
2.0
Priority of OB Execution
OB1_OB_NUMBR
Byte
3.0
OB1_RESERVED_1
Byte
4.0
OB1_RESERVED_2
Byte
5.0
OB1_PREV_CYCLE
Int
6.0
OB1_MIN_CYCLE
Int
8.0
OB1_MAX_CYCLE
Int
10.0
OB1_DATE_TIME
Date_And_Time 12.0
Block: OB1
Network: 1
M141.0
EMERGENCY
STOP
"ES"
M10.3
M10.0
M10.0
Page 1 of 24
SIMATIC
KOMPETENSI 1\
11/03/2016 02:04:39 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
Network: 2
MOTOR 1 CW
M142.0
RESET
"RESET"
M10.0
M10.3
M10.1
M10.1
Network: 3
M10.1
M118.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 1
"I_STG_1"
M10.3
Network: 4
M143.0
TOMBOL
START
UTAMA SC 2
"START_U"
M118.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 1
"I_STG_1"
M10.0
M10.2
M10.2
Page 2 of 24
SIMATIC
KOMPETENSI 1\
11/03/2016 02:04:39 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
Network: 5
I125.3
SENSOR
COUNTER
"S4"
T2
S_PULSE
S
S5T#300MS TV
R
Network: 6
I125.0
SENSOR 1
"S1"
Network: 7
I125.0
SENSOR 1
"S1"
Network: 8
I125.0
SENSOR 1
"S1"
BI
BCD
I125.1
SENSOR 2
"S2"
I125.2
SENSOR 3
"S3"
I125.3
SENSOR
COUNTER
"S4"
T2
M118.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 1
"I_STG_1"
T2
M119.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 2
"I_STG_2"
I125.1
SENSOR 2
"S2"
I125.2
SENSOR 3
"S3"
I125.3
SENSOR
COUNTER
"S4"
I125.1
SENSOR 2
"S2"
I125.2
SENSOR 3
"S3"
I125.3
SENSOR
COUNTER
"S4"
T2
M120.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 3
"I_STG_3"
Page 3 of 24
SIMATIC
Network: 9
I125.0
SENSOR 1
"S1"
Network: 10
I125.0
SENSOR 1
"S1"
Network: 11
I125.0
SENSOR 1
"S1"
KOMPETENSI 1\
11/03/2016 02:04:39 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
I125.1
SENSOR 2
"S2"
I125.2
SENSOR 3
"S3"
I125.3
SENSOR
COUNTER
"S4"
T2
M121.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 4
"I_STG_4"
T2
M122.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 5
"I_STG_5"
T2
M123.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 6
"I_STG_6"
I125.1
SENSOR 2
"S2"
I125.2
SENSOR 3
"S3"
I125.3
SENSOR
COUNTER
"S4"
I125.1
SENSOR 2
"S2"
I125.2
SENSOR 3
"S3"
I125.3
SENSOR
COUNTER
"S4"
Page 4 of 24
SIMATIC
Network: 12
M135.0
UNTUK
PUTARAN
MOTOR CW
1 STEP
"CW_1_
STEP"
KOMPETENSI 1\
11/03/2016 02:04:39 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
MELIHAT POSISI 1
M136.0
UNTUK
PUTARAN
MOTOR CW
2 STEP
"CW_2_
STEP"
M137.0
UNTUK
PUTARAN
MOTOR CW
3 STEP
"CW_3_
STEP"
M133.0
UNTUK
PUTARAN
MOTOR CCW
1 STEP
"CCW_1_
STEP"
M134.0
UNTUK
PUTARAN
MOTOR CCW
2 STEP
"CCW_2_
STEP"
M118.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 1
"I_STG_1"
M134.0
UNTUK
PUTARAN
MOTOR CCW
2 STEP
"CCW_2_
STEP"
M119.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 2
"I_STG_2"
M134.0
UNTUK
PUTARAN
MOTOR CCW
2 STEP
"CCW_2_
STEP"
M120.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 3
"I_STG_3"
M11.7
M10.2
M112.0
MELIHAT
POSISI 1
"POS_1"
M10.2
M113.0
MELIHAT
POSISI 2
"POS_2"
M10.2
M114.0
MELIHAT
POSISI 3
"POS_3"
M112.0
MELIHAT
POSISI 1
"POS_1"
Network: 13
M135.0
UNTUK
PUTARAN
MOTOR CW
1 STEP
"CW_1_
STEP"
MELIHAT POSISI 2
M136.0
UNTUK
PUTARAN
MOTOR CW
2 STEP
"CW_2_
STEP"
M137.0
UNTUK
PUTARAN
MOTOR CW
3 STEP
"CW_3_
STEP"
M133.0
UNTUK
PUTARAN
MOTOR CCW
1 STEP
"CCW_1_
STEP"
M11.7
M113.0
MELIHAT
POSISI 2
"POS_2"
Network: 14
M135.0
UNTUK
PUTARAN
MOTOR CW
1 STEP
"CW_1_
STEP"
MELIHAT POSISI 3
M136.0
UNTUK
PUTARAN
MOTOR CW
2 STEP
"CW_2_
STEP"
M137.0
UNTUK
PUTARAN
MOTOR CW
3 STEP
"CW_3_
STEP"
M133.0
UNTUK
PUTARAN
MOTOR CCW
1 STEP
"CCW_1_
STEP"
M11.7
M114.0
MELIHAT
POSISI 3
"POS_3"
Page 5 of 24
SIMATIC
Network: 15
M135.0
UNTUK
PUTARAN
MOTOR CW
1 STEP
"CW_1_
STEP"
KOMPETENSI 1\
11/03/2016 02:04:40 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
MELIHAT POSISI 4
M136.0
UNTUK
PUTARAN
MOTOR CW
2 STEP
"CW_2_
STEP"
M137.0
UNTUK
PUTARAN
MOTOR CW
3 STEP
"CW_3_
STEP"
M133.0
UNTUK
PUTARAN
MOTOR CCW
1 STEP
"CCW_1_
STEP"
M134.0
UNTUK
PUTARAN
MOTOR CCW
2 STEP
"CCW_2_
STEP"
M121.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 4
"I_STG_4"
M134.0
UNTUK
PUTARAN
MOTOR CCW
2 STEP
"CCW_2_
STEP"
M122.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 5
"I_STG_5"
M134.0
UNTUK
PUTARAN
MOTOR CCW
2 STEP
"CCW_2_
STEP"
M123.0
INDIKATOR
POSISI
SENSOR DI
STORAGE 6
"I_STG_6"
M11.7
M10.2
M115.0
MELIHAT
POSISI 4
"POS_4"
M10.2
M116.0
MELIHAT
POSISI 5
"POS_5"
M10.2
M117.0
MELIHAT
POSISI 6
"POS_6"
M115.0
MELIHAT
POSISI 4
"POS_4"
Network: 16
M135.0
UNTUK
PUTARAN
MOTOR CW
1 STEP
"CW_1_
STEP"
MELIHAT POSISI 5
M136.0
UNTUK
PUTARAN
MOTOR CW
2 STEP
"CW_2_
STEP"
M137.0
UNTUK
PUTARAN
MOTOR CW
3 STEP
"CW_3_
STEP"
M133.0
UNTUK
PUTARAN
MOTOR CCW
1 STEP
"CCW_1_
STEP"
M11.7
M116.0
MELIHAT
POSISI 5
"POS_5"
Network: 17
M135.0
UNTUK
PUTARAN
MOTOR CW
1 STEP
"CW_1_
STEP"
MELIHAT POSISI 6
M136.0
UNTUK
PUTARAN
MOTOR CW
2 STEP
"CW_2_
STEP"
M137.0
UNTUK
PUTARAN
MOTOR CW
3 STEP
"CW_3_
STEP"
M133.0
UNTUK
PUTARAN
MOTOR CCW
1 STEP
"CCW_1_
STEP"
M11.7
M117.0
MELIHAT
POSISI 6
"POS_6"
Page 6 of 24
SIMATIC
Network: 18
M106.0
START DI
STORAGE 1
SC 3
"ST_1"
KOMPETENSI 1\
11/03/2016 02:04:40 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
M11.7
M10.2
M100.0
MEMORY
TOMBOL
START DI
STORAGE 1
SC 3
"M_ST_1"
M100.0
MEMORY
TOMBOL
START DI
STORAGE 1
SC 3
"M_ST_1"
Network: 19
M107.0
START DI
STORAGE 2
SC 4
"ST_2"
M11.7
M10.2
M101.0
MEMORY
TOMBOL
START DI
STORAGE 2
SC 4
"M_ST_2"
M101.0
MEMORY
TOMBOL
START DI
STORAGE 2
SC 4
"M_ST_2"
Page 7 of 24
SIMATIC
Network: 20
M108.0
START DI
STORAGE 3
SC 5
"ST_3"
KOMPETENSI 1\
11/03/2016 02:04:40 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
M11.7
M10.2
M102.0
MEMORY
TOMBOL
START DI
STORAGE 3
SC 5
"M_ST_3"
M102.0
MEMORY
TOMBOL
START DI
STORAGE 3
SC 5
"M_ST_3"
Network: 21
M109.0
START DI
STORAGE 4
SC 6
"ST_4"
M11.7
M10.2
M103.0
MEMORY
TOMBOL
START DI
STORAGE 4
SC 6
"M_ST_4"
M103.0
MEMORY
TOMBOL
START DI
STORAGE 4
SC 6
"M_ST_4"
Page 8 of 24
SIMATIC
Network: 22
M110.0
START DI
STORAGE 5
SC 7
"ST_5"
KOMPETENSI 1\
11/03/2016 02:04:40 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
M11.7
M10.2
M104.0
MEMORY
TOMBOL
START DI
STORAGE 5
SC 7
"M_ST_5"
M104.0
MEMORY
TOMBOL
START DI
STORAGE 5
SC 7
"M_ST_5"
Network: 23
M111.0
START DI
STORAGE 6
SC 8
"ST_6"
M11.7
M10.2
M105.0
MEMORY
TOMBOL
START DI
STORAGE 6
SC 8
"M_ST_6"
M105.0
MEMORY
TOMBOL
START DI
STORAGE 6
SC 8
"M_ST_6"
Page 9 of 24
SIMATIC
Network: 24
KOMPETENSI 1\
11/03/2016 02:04:40 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
M112.0
MELIHAT
POSISI 1
"POS_1"
M100.0
MEMORY
TOMBOL
START DI
STORAGE 1
SC 3
"M_ST_1"
M11.7
M10.0
M135.0
UNTUK
PUTARAN
MOTOR CW
1 STEP
"CW_1_
STEP"
M101.0
MEMORY
TOMBOL
START DI
STORAGE 2
SC 4
"M_ST_2"
M113.0
MELIHAT
POSISI 2
"POS_2"
M101.0
MEMORY
TOMBOL
START DI
STORAGE 2
SC 4
"M_ST_2"
M102.0
MEMORY
TOMBOL
START DI
STORAGE 3
SC 5
"M_ST_3"
M114.0
MELIHAT
POSISI 3
"POS_3"
M102.0
MEMORY
TOMBOL
START DI
STORAGE 3
SC 5
"M_ST_3"
M103.0
MEMORY
TOMBOL
START DI
STORAGE 4
SC 6
"M_ST_4"
M115.0
M103.0
MEMORY
TOMBOL
START DI
Page 10 of 24
SIMATIC
M115.0
MELIHAT
POSISI 4
"POS_4"
KOMPETENSI 1\
11/03/2016 02:04:40 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
START DI
STORAGE 4
SC 6
"M_ST_4"
M104.0
MEMORY
TOMBOL
START DI
STORAGE 5
SC 7
"M_ST_5"
M116.0
MELIHAT
POSISI 5
"POS_5"
M104.0
MEMORY
TOMBOL
START DI
STORAGE 5
SC 7
"M_ST_5"
M105.0
MEMORY
TOMBOL
START DI
STORAGE 6
SC 8
"M_ST_6"
M117.0
MELIHAT
POSISI 6
"POS_6"
M100.0
MEMORY
TOMBOL
START DI
STORAGE 1
SC 3
"M_ST_1"
M105.0
MEMORY
TOMBOL
START DI
STORAGE 6
SC 8
"M_ST_6"
Page 11 of 24
SIMATIC
Network: 25
KOMPETENSI 1\
11/03/2016 02:04:40 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
M112.0
MELIHAT
POSISI 1
"POS_1"
M102.0
MEMORY
TOMBOL
START DI
STORAGE 3
SC 5
"M_ST_3"
M113.0
MELIHAT
POSISI 2
"POS_2"
M103.0
MEMORY
TOMBOL
START DI
STORAGE 4
SC 6
"M_ST_4"
M102.0
MEMORY
TOMBOL
START DI
STORAGE 3
SC 5
"M_ST_3"
M104.0
MEMORY
TOMBOL
START DI
STORAGE 5
SC 7
"M_ST_5"
M115.0
MELIHAT
POSISI 4
"POS_4"
M105.0
MEMORY
TOMBOL
START DI
STORAGE 6
SC 8
"M_ST_6"
M116.0
MELIHAT
POSISI 5
"POS_5"
M100.0
MEMORY
TOMBOL
START DI
STORAGE 1
SC 3
"M_ST_1"
M117.0
MELIHAT
POSISI 6
"POS_6"
M101.0
MEMORY
TOMBOL
START DI
STORAGE 2
SC 4
"M_ST_2"
M11.7
M10.0
M136.0
UNTUK
PUTARAN
MOTOR CW
2 STEP
"CW_2_
STEP"
Page 12 of 24
SIMATIC
Network: 26
KOMPETENSI 1\
11/03/2016 02:04:41 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
M112.0
MELIHAT
POSISI 1
"POS_1"
M103.0
MEMORY
TOMBOL
START DI
STORAGE 4
SC 6
"M_ST_4"
M113.0
MELIHAT
POSISI 2
"POS_2"
M104.0
MEMORY
TOMBOL
START DI
STORAGE 5
SC 7
"M_ST_5"
M114.0
MELIHAT
POSISI 3
"POS_3"
M105.0
MEMORY
TOMBOL
START DI
STORAGE 6
SC 8
"M_ST_6"
M115.0
MELIHAT
POSISI 4
"POS_4"
M100.0
MEMORY
TOMBOL
START DI
STORAGE 1
SC 3
"M_ST_1"
M116.0
MELIHAT
POSISI 5
"POS_5"
M101.0
MEMORY
TOMBOL
START DI
STORAGE 2
SC 4
"M_ST_2"
M117.0
MELIHAT
POSISI 6
"POS_6"
M102.0
MEMORY
TOMBOL
START DI
STORAGE 3
SC 5
"M_ST_3"
M11.7
M10.0
M137.0
UNTUK
PUTARAN
MOTOR CW
3 STEP
"CW_3_
STEP"
Page 13 of 24
SIMATIC
Network: 27
KOMPETENSI 1\
11/03/2016 02:04:41 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
M112.0
MELIHAT
POSISI 1
"POS_1"
M105.0
MEMORY
TOMBOL
START DI
STORAGE 6
SC 8
"M_ST_6"
M113.0
MELIHAT
POSISI 2
"POS_2"
M100.0
MEMORY
TOMBOL
START DI
STORAGE 1
SC 3
"M_ST_1"
M114.0
MELIHAT
POSISI 3
"POS_3"
M101.0
MEMORY
TOMBOL
START DI
STORAGE 2
SC 4
"M_ST_2"
M115.0
MELIHAT
POSISI 4
"POS_4"
M102.0
MEMORY
TOMBOL
START DI
STORAGE 3
SC 5
"M_ST_3"
M116.0
MELIHAT
POSISI 5
"POS_5"
M103.0
MEMORY
TOMBOL
START DI
STORAGE 4
SC 6
"M_ST_4"
M117.0
MELIHAT
POSISI 6
"POS_6"
M104.0
MEMORY
TOMBOL
START DI
STORAGE 5
SC 7
"M_ST_5"
M11.7
M10.0
M133.0
UNTUK
PUTARAN
MOTOR CCW
1 STEP
"CCW_1_
STEP"
Page 14 of 24
SIMATIC
Network: 28
KOMPETENSI 1\
11/03/2016 02:04:41 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
M112.0
MELIHAT
POSISI 1
"POS_1"
M104.0
MEMORY
TOMBOL
START DI
STORAGE 5
SC 7
"M_ST_5"
M113.0
MELIHAT
POSISI 2
"POS_2"
M105.0
MEMORY
TOMBOL
START DI
STORAGE 6
SC 8
"M_ST_6"
M114.0
MELIHAT
POSISI 3
"POS_3"
M100.0
MEMORY
TOMBOL
START DI
STORAGE 1
SC 3
"M_ST_1"
M115.0
MELIHAT
POSISI 4
"POS_4"
M101.0
MEMORY
TOMBOL
START DI
STORAGE 2
SC 4
"M_ST_2"
M116.0
MELIHAT
POSISI 5
"POS_5"
M102.0
MEMORY
TOMBOL
START DI
STORAGE 3
SC 5
"M_ST_3"
M117.0
MELIHAT
POSISI 6
"POS_6"
M103.0
MEMORY
TOMBOL
START DI
STORAGE 4
SC 6
"M_ST_4"
M11.7
M10.0
M134.0
UNTUK
PUTARAN
MOTOR CCW
2 STEP
"CCW_2_
STEP"
Page 15 of 24
SIMATIC
KOMPETENSI 1\
11/03/2016 02:04:41 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
Network: 29
M100.0
MEMORY
TOMBOL
START DI
STORAGE 1
SC 3
"M_ST_1"
I125.3
SENSOR
COUNTER
"S4"
C1
S_CU
CU
M101.0
MEMORY
TOMBOL
START DI
STORAGE 2
SC 4
"M_ST_2"
S
PV
Q
CV
CV_BCD
MW50
M102.0
MEMORY
TOMBOL
START DI
STORAGE 3
SC 5
"M_ST_3"
M103.0
MEMORY
TOMBOL
START DI
STORAGE 4
SC 6
"M_ST_4"
M104.0
MEMORY
TOMBOL
START DI
STORAGE 5
SC 7
"M_ST_5"
M105.0
MEMORY
TOMBOL
START DI
STORAGE 6
SC 8
"M_ST_6"
M11.7
R
M10.3
M142.0
RESET
"RESET"
Page 16 of 24
SIMATIC
KOMPETENSI 1\
11/03/2016 02:04:41 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
Network: 30
COMPARATOR NILAI 1
M80.0
M20.0
CMP ==I
MW50 IN1
1 IN2
Network: 31
COMPARATOR NILAI 2
M135.0
UNTUK
PUTARAN
MOTOR CW
1 STEP
"CW_1_
STEP"
M133.0
UNTUK
PUTARAN
MOTOR CCW
1 STEP
"CCW_1_
STEP"
CMP ==I
M130.0
NILAI
COUNTER 1
STEP
"1_STEP"
2 IN1
MW50 IN2
Page 17 of 24
SIMATIC
KOMPETENSI 1\
11/03/2016 02:04:41 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
Network: 32
COMPARATOR NILAI 3
M136.0
UNTUK
PUTARAN
MOTOR CW
2 STEP
"CW_2_
STEP"
CMP ==I
M134.0
UNTUK
PUTARAN
MOTOR CCW
2 STEP
"CCW_2_
STEP"
M131.0
NILAI
COUNTER 2
STEP
"2_STEP"
3 IN1
MW50 IN2
Network: 33
COMPARATOR NILAI 4
M137.0
UNTUK
PUTARAN
MOTOR CW
3 STEP
"CW_3_
STEP"
CMP ==I
M132.0
NILAI
COUNTER 3
STEP
"3_STEP"
4 IN1
MW50 IN2
Page 18 of 24
SIMATIC
KOMPETENSI 1\
11/03/2016 02:04:41 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
Network: 34
PROSES MENGHENTIKAN MOTOR STORAGE OFF
M130.0
NILAI
COUNTER 1
STEP
"1_STEP"
M11.7
M10.0
M11.0
M20.0
M131.0
NILAI
COUNTER 2
STEP
"2_STEP"
M132.0
NILAI
COUNTER 3
STEP
"3_STEP"
M11.0
Network: 35
T3
S_ODT
M11.0
S
S5T#250MS TV
R
M15.0
Q
BI
BCD
Page 19 of 24
SIMATIC
KOMPETENSI 1\
11/03/2016 02:04:41 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
Network: 36
PROSES KONVEYOR CW SLOW ON
I124.1
SENSOR
KONVEYOR 1
"SEN1"
M11.0
M11.1
M11.1
Network: 37
MOTOR KONVEYOR CW OFF
I124.0
SENSOR
KONVEYOR 2
"SEN2"
M11.1
M11.3
M11.3
Network: 38
KONTAK TIMER 1 SETELAH 3S
T1
M12.0
N
M11.3
M11.4
M11.4
Page 20 of 24
SIMATIC
KOMPETENSI 1\
11/03/2016 02:04:41 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
Network: 39
PROSES KONVEYOR CCW FAST ON
I124.0
SENSOR
KONVEYOR 2
"SEN2"
M11.4
M11.5
M11.5
Network: 40
MOTOR KONVEROR CCW OFF
I124.1
SENSOR
KONVEYOR 1
"SEN1"
M11.5
M11.7
M11.7
Network: 41
DELAY TIMER 3S BUZZER
T1
S_PEXT
M11.3
S
S5T#3S TV
R
Q
BI
BCD
Page 21 of 24
SIMATIC
KOMPETENSI 1\
11/03/2016 02:04:42 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
Network: 42
SPEED FAST
M11.5
M11.7
EN
30000 IN
MOVE
ENO
OUT PQW800
Network: 43
SPEED SLOW
M11.1
M11.3
EN
10000 IN
Network: 44
M135.0
UNTUK
PUTARAN
MOTOR CW
1 STEP
"CW_1_
STEP"
MOVE
ENO
OUT PQW800
MOTOR STORAGE CW
M15.0
Q125.1
MOTOR
STORAGE
CCW
"MCCW"
Q125.0
MOTOR
STORAGE CW
"MCW"
M136.0
UNTUK
PUTARAN
MOTOR CW
2 STEP
"CW_2_
STEP"
M137.0
UNTUK
PUTARAN
MOTOR CW
3 STEP
"CW_3_
STEP"
M10.1
Page 22 of 24
SIMATIC
Network: 45
M133.0
UNTUK
PUTARAN
MOTOR CCW
1 STEP
"CCW_1_
STEP"
KOMPETENSI 1\
11/03/2016 02:04:42 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
M15.0
Q125.0
MOTOR
STORAGE CW
"MCW"
Q125.1
MOTOR
STORAGE
CCW
"MCCW"
M134.0
UNTUK
PUTARAN
MOTOR CCW
2 STEP
"CCW_2_
STEP"
Network: 46
M11.1
Network: 47
M11.5
MOTOR KONVEYOR CW
M11.3
Q124.6
MOTOR
KONVEYOR
CW
"KCW"
M11.7
Q124.7
MOTOR
KONVEYOR
CCW
"KCCW"
Page 23 of 24
SIMATIC
Network: 48
M11.3
KOMPETENSI 1\
11/03/2016 02:04:42 PM
SIMATIC 300(1)\CPU 314C-2 PN/DP\...\OB1 - <offline>
BUZZER / SPEAKER
M11.4
M140.0
BUZZER /
SPEAKER
"BUZ"
Page 24 of 24