Anda di halaman 1dari 1

ADDITIONAL FIRE NOTES

ALL WORKS TO COMPLY WITH ACT 103 OF 1977 AND SANS


10400 PART T -2011
OCCUPANCY CLASSIFICATION : G1 AS PER SANS 10400-A
CLAUSE 20
DOOR ALONG ESCAPE ROUTES ARE ONLY TO BE FITTED WITH
APPROVED LOCKING DEVICES AND SHALL COMPLY WITH
CLAUSE 4.16, 4,17 & 4,19.
EMERGENCY LIGHTING TO BE INSTALLED AND DESIGNED IN
ACCORDANCE WITH SANS 10400 - PART T AND SANS 10114-2
AND SANS 1464-22 AS PER CLAUSE 4.30. SEE LIGHTING AND
CEILING LAYOUT.
FIRE DETECTION AND EMERGENCY EVACUATION
COMMUNICATION SYSTEMS WHICH COMPLY WITH SANS 10139
TO BE INSTALLED AS PER CLAUSE 4.31
PHOTOLUMINESCENT ESCAPE SIGNS TO BE PROVIDED AND
TO COMPLY WITH SANS 1186 PART 1 &5 AS PER CLAUSE 4.29.
PHOTOLUMINESCENT SYMBOLIC SIGNS, INDICATING FIRE
EQUIPMENT TO BE PROVIDED AND COMPLY WITH SANDS 1186
PART 1 & 5 AS PER CLAUSE 4.32.
SUSPENDED CEILINGS AND ITS SUPPORTING MEMBERS
SHALL BE OF NON -COMBUSTIBLE MATERIALS.
STRUCTURAL ELEMENTS AND COMPONENTS SHALL HAVE A
MINIMUM STABILITY RATING OF 60 MINUTES.
EXISTING SPRINKLER SYSTEMS WILL BE EXTENDED / ALTERED
TO PROVIDE PROTECTION TO NEW EXTENSION OR
ALTERATIONS.
INSULATION MATERIAL TO COMPLY WITH SANS 426 : 2006

90

55

5 505

2 595

55

2 735

90

3 200

90

2 477

5 440

3 684
D8b

1 200

PAUSE
AREA

8 STAFF
LOCKERS
C

90

D9c

D8a

FEMALE
TOILETS

C
D9c

C
STORE
ROOM

1 000

1 500 90

IN DESK

1 590 410

6 112

DB

D9c

D9c

MALE
TOILET

WORKTOPS: HARVARD CHERY-FORMICA OR NATURAL


CHERRY-MAX ON TOP
ALL DOORS TO BE WHITE MELAMINE
OVER SINK HANGING CROCKERY CUPBOARD
SINGLE CUTLERY DRAWER UNDER SINK
MICROWAVE SHELF ABOVE FRIDGE
PAINT ALL CUPBOARDS INSIDE WITH WHITE PVA
SINK: FRANKE QUINLINE SINGLE END BOWL, MODEL: QLL611,
CODE: 820117
TAP: COBRA CARINA 296CA SINK MIXER, AVAILABLE FROM COBRA.

SYMBOL SPECIFICATION
HYDRO2.5

90

6 802

1 648

2.5 LITRE HYDROBOIL (FOR BRANCHES WITH 10 OR LESS STAFF)

ZIP HYDROBOIL 2.5 LITRE (CODE 380000) INSTANT BOILING WATER UNIT WITH WHITE EPOXY POWDER
COATED OUTER CASE, AND A TWO-WAY TAP, COMPLETE WITH TWIN-CHAMBER TECHNOLOGY. UNIT TO BE
INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTION MANUAL . 250 (W) X 150
(D) X 431 (H) MAX. CUPS AT ANY ONE TIME12 - 15. APPROX. RECOVERY RATE PER MINUTE : 1 CUP. ELEMENT
1.5 KW, REQUIRES SINGLE PHASE 220-230V

5 LITRE HYDROBOIL (FOR BRANCHES WITH 11 TO 40 STAFF)

5 173
HYDRO5.0

FIRST FLOOR PLAN Scale 1:100


HYDRO7.5

ZIP HYDROBOIL 7,5 LITRE (CODE 380004) INSTANT BOILING WATER UNIT WITH WHITE EPOXY POWDER
COATED OUTER CASE, AND A TWO-WAY TAP, COMPLETE WITH TWIN-CHAMBER TECHNOLOGY. UNIT TO BE
INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTION MANUAL . 318 (W) X 180
(D) X460 (H) MAX. CUPS AT ANY ONE TIME 36-45. APPROX. RECOVERY RATE PER MINUTE : 1 CUP. ELEMENT
1.5 KW, REQUIRES SINGLE PHASE 220-230V

DISTRIBUTION BOARD
FIRE REGULATION NOTE

1 HR FIRE RATED DRYWALL, AS PER SANS PART T

1 631
2 977
90
90
1 150

1 436

9610

90

SF3

E-07

TREASURY
CLERK

ST15/01

4 290

CLIENT AREA
M

SHOP FRONT RESISTO GLASS NOTE


RESISTO GLASS TO BE USED FOR SHOP FRONT, SEE
SPECIFICATIONS & DETAILS ON DRAWING. THIS GLASS NOT TO BE
USED WHERE OUTLET IS ON THE INSIDE OF A SECURED
SHOPPING CENTRE. REFER TO DWG GEN_ARM_046 & 047

1 810

90

1 360

PARA/
FEMALE

D9c

KITCHEN

UNISEX
TOILET

1 691

115

110mm MASONRY WALL.

100mm ABOVE CEILING LEVEL

90mm DRY WALL PARTITION, TO 100mm ABOVE CEILING

C
H

2HR FIRE RESISTANT DRY WALL

2mm LINED DEMOUNTIBLE METAL WALL SYSTEM (128mm)


FULL HEIGHT TO UNDERSIDE OF SOFFIT / ROOF

M1

2mm LINED DEMOUNTIBLE METAL WALL SYSTEM (128mm) TO


BE BUILT TO 1 METER ABOVE CEILING AND MESH FROM TOP
OF WALL TO UNDER SIDE OF SOFFIT /ROOF
1mm LINED DEMOUNTIBLE METAL WALL SYSTEM (128mm)

INTERNAL SHOP FRONT TYPES


CODE
SF1

DESCRIPTION
2700mm HIGH FRONT OF HOUSE PRIVATE OFFICE
FRAME LESS HIGH SPECIFICATION

160

AIR TUBE POINT - 160mm

SECURITY CAMERA POSTS

CFNP_KOOLCON_GRAHGAMSTOWN_WD_DEM

DEMOLITION LAYOUT

CFNP_KOOLCON_GRAHGAMSTOWN_WD_CON

CONSTRUCTION LAYOUT

CFNP_KOOLCON_GRAHGAMSTOWN_WD_DS

DOOR SCHEDULE AND DETAILS

CFNP_KOOLCON_GRAHGAMSTOWN_WD_WF

WALL FINISHES LAYOUT

CFNP_KOOLCON_GRAHGAMSTOWN_WD_FLF

FLOOR FINISHES LAYOUT

CFNP_KOOLCON_GRAHGAMSTOWN_WD_FURN

FURNITURE LAYOUT

CFNP_KOOLCON_GRAHGAMSTOWN_WD_ELEC

ELECTRICAL LAYOUT

CFNP_KOOLCON_GRAHGAMSTOWN_WD_CEIL

LIGHTING AND CEILING LAYOUT

CFNP_KOOLCON_GRAHGAMSTOWN_WD_CORD

SERVICES COORDINATION

CFNP_KOOLCON_GRAHGAMSTOWN_WD_DET

GENERIC DETAILS LAYOUT

CFNP_KOOLCON_GRAHGAMSTOWN_WD_SECT

SECTION & WALL DETAILS

REVISION HISTORY

TO BE LOCATED AT ENTRANCE OF BRANCHES,

POST IS AN UPRIGHT 101.6 STAINLESS STEEL TUBE IN A BRUSHED No.4 FINISH

SPIGOT ASSEMBLY TO BE BOLTED INTO THE GROUND WITH 3xM10 RAWL BOLTS

UPRIGHT TO BE FASTENED TO SPIGOT ASSEMBLY BY MEANS OF 1XM4 BOLT

Rev Description

By

DATE

FROM REAR (THROUGH SLOT TO ALLOW FOR SWIVEL ADJUSTMENT

FIRE REGULATION NOTE

103 High street


Grahamstown

1 HR FIRE RATED DRYWALL, AS PER SANS PART T

Usable Area:

Cash Area: 80 m

Staff Compliment: 25

LOBBIES REQUIRED AT ALL LIFTS, 30 MINUTES FIRE

Sales Area: 362m

Internet: 2

RATING WITH COLD SMOKE SEALS

External Devices: CAD:3 ATM:1

m2 per Head (Usable):

ESCAPE ROUTES

Increase Size of
opening and replace
Fire Door

ALL DOORS ALONG ESCAPE ROUTES TO PREFERABLY


HAVE PUSH BARS

Mini High

BRANCH TYPE AND AREAS:


Rentable Area: GFL=345 m FFL= 327m

AROUND DISTRIBUTION BOARDS IN EMERGENCY

Rentable Area: GFL=345 m FFL= 327m


Total= 672 m

Landing

D9a

D10

AIR TUBE POINT - 110mm

SPECIFICATION:

Create 1000mm
Opening

D18

90

AIR TUBE SYSTEM

SECURITY CAMERA

1 000
1 200

1 637

A3

PROGRAM_ORIGINATOR_BRANCH NAME_DOCUMENT TYPE_DRAWING TYPE_VERSION

390

230mm PERIMETER PLASTERED MASONRY WALL.


BRICKWORK OF NFP CLAY BRICKS IN CLASS II MORTAR TO
BE BUILT TO 1 METER ABOVE CEILING AND MESH FROM
TOP OF WALL TO UNDER SIDE OF SOFFIT /ROOF
230mm PERIMETER PLASTERED MASONRY WALL.
BRICKWORK OF NFP CLAY BRICKS IN CLASS II MORTAR TO
BE BUILT TO 100mm ABOVE CEILING - ABLUTIONS ONLY

CUSTOM HEIGHT FRONT OF HOUSE PRIVATE OFFICE


SF2

NO CEILING PROTECTION IS REQUIRED OVER ATM, TREASURY


FRAME LESS HIGH SPEC
AND UTILITY ROOMS DUE TO VISUAL VERIFICATION.

ALL WALLS THAT FORM UTILITY ROOM, TREASURY, ATM WALL


2700mm HIGH FRONT OF HOUSE PRIVATE OFFICE
SF3
AND PERIMETER WALLS TO BE TO A HEIGHT OF 1m ABOVE
STANDARD ALUMINUM FRAME
CEILING HEIGHT. ONLY PERIMETER WALLS FORMING THE
PERIMETER OF THE BANK WILL HAVE A MESH FROM 3700mm TO
CUSTOM HEIGHT FRONT OF HOUSE PRIVATE OFFICE
SF4
STANDARD ALUMINUM FRAME
UNDERSIDE OF SLAB OR ROOF.

STEEL FRAME WITH MESH DESIGNED BY STRUCTURAL ENGINEER


BACK OF HOUSE PRIVATE OFFICE WINDOW
SF5
ABOVE PERIMETER WALL ONLY. EXPANDED METAL (MENTEX)
1800 (H) x 500 (W) TO BE ALIGNED WITH TOP OF DOOR
6 mm THICK 20 mm X 60 mm (Code:MENTEX 70/VEM 325A).

THE RSC SHALL DETERMINE ANY ADDITIONAL AREAS TO BE


REFERENCE DRAWINGS
PROTECTED BASED ON THE RISK AND SITE-SPECIFIC FACTORS.

1 770 90

1 800

M BCTU
AREA

A2

SECURITY SPECIFICATIONS

ONLY WHEN STACKING DOOR SYSTEMS AND AUTOMATED SLIDING DOORS ARE USED

D6b

500

8 STAFF
LOCKERS

1 220 390
2 000

230

SF3

E-06

LANDING 01

90

115 1 330

1 200

385
1 875 115

HELPLINE

BRANCH
MANAGER

SC

1 380

WAITING AREA

SF3

110

treasury
safe

M1

3 170

MIN 1m OPENABLE WINDOW FOR EACH STAIRCASE AT

COIN CAGE

M1

D8b

INTEL
CAB

INTERNET
KIOSK

3 551
3 190

D6b

FPR29

385

HOST FN15/18
PODIUM

2 515

LOBBIES REQUIRED AT ALL LIFTS, 30 MINUTES FIRE

3 079

BULK
TELLER

1 211

470 500
D8b

E-06

2 785

FHR

270

230

3 185

600

MAIN
ENTRANCE
DOOR

ALL DOORS ALONG ESCAPE ROUTES TO PREFERABLY

EACH LANDING FOR NATURAL VENTILATION

90

1 550

90 1 020 90
448
1 420

M1

D4

3 465
2 450

3 340

M1
M1

New stairs

5
6
7
8
9
Existing stairs

2 145
90
1 211

900

950
2 193

1 215

E-07

1 235

1 643

RATING WITH COLD SMOKE SEALS


O15/02

D8b

D12

M1

M SF3

4 32 1

M1

M1

675

New
Landing

M1

2 075

M1

DB BOARD

3 196

M1

1 470

1 200 90

D8b

2 x CUSTOMER SERVICES

230

D6e

SF3

4 x RETAIL TELLERS

8 434

NEW SHOPFRONT

IN
OUT

NEW
GLASS FIRE
ESCAPE DOOR

M1

M1

fax &
photo

90

D17b
M

1 145

1 511
90

D5b

HAVE PUSH BARS

CAB9

6634 Standard
Sleeve CAD

90

F14W

470

90

6634 Standard
Sleeve CAD

1 800

M1
6634 Standard
Sleeve CAD

3 336

6634 Standard
Sleeve CAD

90

ESCAPE ROUTES

FN15/63L

1 000

700

ATM ROOM

AROUND DISTRIBUTION BOARDS IN EMERGENCY

6 237

90

914 (L) x 381


(D) x 1800 (H)
O15/16

4 700
527
527
673
673

3 193

1 580

1 136

1 789

1 236

90

2 900

1 050

4 603

1 496

103

1 518

90

673

115

4 357

689

QTY

ZIP HYDROBOIL 5 LITRE (CODE 380002) INSTANT BOILING WATER UNIT WITH WHITE EPOXY POWDER COATED
OUTER CASE, AND A TWO-WAY TAP, COMPLETE WITH TWIN-CHAMBER TECHNOLOGY. UNIT TO BE INSTALLED
IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTION MANUAL . 318 (W) X 150 (D) X460 (H)
MAX. CUPS AT ANY ONE TIME 25-30. APPROX. RECOVERY RATE PER MINUTE : 1 CUP. ELEMENT 1.5 KW,
REQUIRES SINGLE PHASE 220-230V

7.5 LITRE HYDROBOIL (FOR BRANCHES WITH 41 OR MORE STAFF)

5 953

HYDROBOIL SPECIFICATIONS

90

FHR

90

CLEANERS
STORE

1 810

90

600

D20

ALL RAMPS TO COMPLY WITH THE NATIONAL BUILDING


REGULATIONS PART S.
ALL RAMPS TO HAVE A GRADIENT, MEASURED ALONG THE
CENTRE LINE, OF NOT MORE THAN:
1:12 WHERE THE DIFFERENCE IN LEVEL OF THE ENDS OF
THE RAMP IS MORE THAN 400mm OR
1:10 WHERE SUCH DIFFERENCE LEVEL IS NOT MORE THAN
400mm
HAVE CLEAR TRAFFICABLE SURFACE NOT LESS THEN 1100mm
WIDE
HAVE A SURFACE CONSTRUCTED OF A SLIP RESISTANT MATERIAL
BE PROVIDED WITH A LANDING FOR EVERY 1500mm OF VERTICAL
RISE, AND SUCH LANDING SHALL BE NOT LESS THAN 1200mm IN
LENGTH AND HAVE A WIDTH OF NOT LESS THAN THE RAMP
BE PROVIDED WITH A HANDRAIL ON THE SIDE WHERE THE
CHANGE IN LEVEL BETWEEN THE ENDS OF THE RAMP IS MORE
THAN 600mm, AND SUCH HANDRAIL SHALL:
BE POSITIONED BETWEEN 850mm AND 1000mm ABOVE THE
SURFACE OF THE RAMP
BE SO FINISHED OFF AS NOT TO PRESENT A HAZARD TO ANY
PERSON USING SUCH RAMP
FOLLOW THE GRADIENT OF SUCH RAMP FOR THE FULL
LENGTH OF THE RAMP

KITCHEN SPECIFICATIONS
D8a

914 (L) x 381 914 (L) x 381


(D) x 1800 (H) (D) x 1800 (H)

1 785

BMS FAL

IT PATCH
ROOM

CHECK

90

3 080

90

740mm HIGH x 800mm DEEP, HARVARD CHERY-FORMICA OR


NATURAL CHERRY-MAX, FINISH LENGTH ACCORDING TO PLAN.
REFER TO DETAIL DWG : GEN_DET15FURN29 TO
GEN_DET15FURN32 & GEN_DET15FURN36

1 200

FITTINGS

All materials and finishes to be utilised and procured from specified suppliers
only.

WC: CONCORDE CLOSED COUPLE SUITE, CODE:772763

Any contradiction on the plans must be brought under the attention of ABSA

URINAL: LAVATERA, CODE: 705427


Architectural Studio and the Appointed Project architect. .

All Works and finishes to comply with the ABSA specifications.

BASIN: TUSCANY PEDESTAL BASIN 560X415, CODE: 7006 OR

Refer to detail documentation where indications.


CAMEO DROP IN 595X455, CODE: 7028

All dimensions to be checked on site by contractor prior to ordering of materials

BASIN PARAPLEGIC FACILITY: BANTAM BASIN 455X290, CODE:


and construction. Each supplier/ sub-contractor will be totally responsible for
checking all site dimension & conditions & taking setting out points and
7030
attainment of proper materials specified for approval prior to commencing of
ALL FITTINGS TO BE WHITE,
any alignment & levels. Each supplier must submit detailed drawings and
samples of fabrication on or off site if specification varies from approved ABSA
AVAILABLE FROM: VAAL SANITARY WARE, TEL: 016-360-6000
specifications.
TAPS:

All variations to be confirmed and agreed in writing with related cost copies to

BASINS: COBRA CARINA 292CA BASIN MIXER


PM, contractor, QS, designer and client, all agreed prior to any works carried
out.

BASIN PARAPLEGIC FACILITY: COBRA RAISED NOSE PILLAR TAP

Do not scale this drawing, use figured dimensions only. If any discrepancies
503-21B & 503-21R
arise please contact the project architect immediately.

All consultants must examine drawings on completion for finishes, materials,


AVAILABLE FROM: COBRA
specification. No claim on grounds of lack of knowledge to details will be
VANITY TOP:
entertained after the completion date.

HARVARD CHERRY FORMICA

Designer has the right to change any of the specifications on this page without
notice. Contractor should always liase with designer and out-line programme
AVAILABLE FROM: PG BISON
and finishes schedule.
ACCESSIBLE TOILETS
GRAB RAILS:
LEGEND

GRAB BAR - ANGLE 135 - CNTX 700A, 32mm , STAINLESS STEEL.


EXISTING PARTITION
EXISTING WALL
LENGTH = 618mm.

32mm C.P. GRAB RAIL - STAINLESS STEEL


NEW PARTITION
NEW WALL

GRAB BAR - STRAIGHT - CNTX 550, 32mm , STAINLESS STEEL,


METAL WALL
LENGTH = 550mm
ADDITIONAL NOTES:
WALL TYPES

DIVIDING WALLS CAN BE DRYWALL, PANELLING OR BRICK


CODE
DESCRIPTION
DEPENDING ON SITE-SPECIFIC REQUIREMENT.
230mm PLASTERED MASONRY WALL.

THESE GUIDELINES ARE FOR ANY OUTLET WHERE ABSA NEEDS


A
BRICKWORK OF NFP CLAY BRICKS IN CLASS II MORTAR TO
TO APPLY ABLUTIONS FOR BACK OFFICE APPLICATIONS. FRONT
BE BUILT 1m ABOVE CEILING LEVEL
OFFICE (CLIENTS) APPLICATIONS WILL BE DETERMINED BY
230mm PERIMETER PLASTERED MASONRY WALL.
A1
BUILDING FINISHES AND OR SBU REQUIREMENT.
BRICKWORK OF NFP CLAY BRICKS IN CLASS II MORTAR TO
RAMPS SPECIFICATIONS
BE BUILT TO UNDER SIDE OF SOFFIT / ROOF

WORK TOP AREA SPECIFICATIONS

90

90
1 115

2 558

2 558

8 9 10 1112 13 14 1516 1718 19 20 21 22 23

1 590

46"TV15/01

5 090

STAIRCASE UP

1 550

914 (L) x 381


(D) x 1800 (H)

D6b

1 103

SALES CONSULTANTS

5 774

ST15/07

FN15/58

WAITING AREA

SF3

90

COFFEE STOP

ST15/07

10 260

ST15/07

FN15/12 46"TV15/02

D8b

2 187

D8b

2 900

7 702

SF3

914 (L) x 381 (D) x 1800 (H)

SF3

fax &
photo

2 956
C

D6b

D6b

PRIVATE
OFFICE

1 111

SF3

90

2 933

1 118

SF3

FSU04

PRIVATE
OFFICE

FSU04

PRIVATE
OFFICE

FSU04

14 SEATER
BOARD ROOM

SEMI PRIVATE

SEMI PRIVATE

FSU04

NOTES

Total= 672 m

EACH LANDING FOR NATURAL VENTILATION

Cnr New Market &


Witkoppen,
Unit D8, Deco Park,
New Market Rd,
Johannesburg,
2162
Phone:011 465 6947

Site Plan Scale 1:200

1 810

21.1m

MIN 1m OPENABLE WINDOW FOR EACH STAIRCASE AT

3 639

ARCHITECTURAL FIRM JOB NUMBER :

C.R.E.S
Corporate Real Estate Services

GROUND FLOOR PLAN Scale 1:100

VI: 2015

5th Floor
Broadcast House, 171 Fox Street, Johannesburg
2000. Tel: 011 846 8500
900

Measure From Plan

PROJECT

WU04

WU01

WU06

WU06

520

WF
15/09

WF
15/09

100
2 700

Havard Cherrie Top

HYDRO 5.0L
PLUG POINT

520 X 1410
OPENING
FOR CASH
DROP UNIT

WF15/04
PLUG TO BE ALIGNED
WITH CENTRE OF SAFE

FPR09
PLUG POINT

PLUG POINT

FSU01

FSU01

Elevation E-06
KITCHEN UNIT GROUND FLOOR
SCALE 1:50

Elevation E-02
KITCHEN UNIT
SCALE 1:50

FPR25

FPR24B

TREASURY SAFE PLUG


POINT HEIGHT
SCALE 1:50

DROP SAFE
OPENING
SCALE 1: 50

SF3

FPR15

FSU04

BCTU OPENING
SCALE 1:50

103 HIGH STREET, GRAHAMSTOWN,


EASTERN CAPE

DRAWING NAME

985

770 X 985
OPENING
FOR BCTU

1 600

O15/18
Undercounter Fridge.
Supplied by Koolcon

235 X 265
OPENING
FOR VIEW
PANEL

1 733

Havard Cherrie Top

PROJECT ADDRESS

WITH CENTRE OF SAFE

265

HYDRO 2.5L

D6b

PLUG TO BE ALIGNED

PLUG POINT

PLUG POINT

PLUG POINT

Note: Tiling to continue


behind fridge

WU04

WU01

ABSA Grahamstown

235

WF15/01

WF15/01

2 700

600

600

1 410

600

600

1 600

600

600

ATM SAFE PLUG POINT


HEIGHT
SCALE 1:50

New Internal Banch Fit-out


Ground & First Internal Changes
Construction Layout

PRIVATE OFFICE
ELEVATION

ARCHITECTURAL FIRM

Koolcon Proffesional Services

DRAWN BY

DATE

APPROVED BY

DATE

SCALE 1:50

RC Eicker

24/08/2016

BUILDING No.

DRAWING STATUS

SCALE / PAGE

xxxx

Concept Design Apporved

1:100

DRAWING NUMBER
CFNP_KOOLCON_Grahamstown_CDA_CON
GSPublisherEngine 0.0.100.100

A1

REV No.
0.3

THIS DRAWING TO BE HANDLED WITH GREAT CONFIDENTIALITY - DO NOT FORWARD A MANUAL OR ELECTRONIC COPY TO ANY OTHER PARTY WITHOUT THE CONSENT OF ABSA CRES PSM. DO NOT DISPLAY OR DISTRIBUTE UNDER ANY CIRCUMSTANCES

5 000

SANITARY SPECIFICATIONS

Anda mungkin juga menyukai