Operation
1. During start and operation,please check whether reading on
instruments are normal,whether bearing is overheated,whether there is
water leakage from stuffing,and whether vibration and noises of pump
are normal,please handle in time when abnormal situations occur
2. Maximum temperature of bearing shall be no more than 80 C,and
bearing temperature shall not be higher than ambient temperature by
more than 40 C
3. When stuffing is normal,water leakage shall be of minor ammount and
even
4. Oil level bearing shall be normal,not to high or too low,add the
lubricating oil in time when it is too low
5. When abrasion on the coupling part between a seal ring and an
impeller is too serious,please replace with a new seal ring.
Failure/permasalahan
1.pump not suck
water,both pointers of
manometer and
vacuometer severely
jump
2.Pump not suck
water,high vacumm
shown on vacuometer
penyebabnya
A. Water input the
water pump is not
enoug
B. Air leakage on
water input pipes
and instruments
A. Bottom valve not
opened or blocked
up
B. Too large
resistance of the
suction pipeline
C. Too high suction
height
Troubelshooting/penanga
nan
A. Input more water
into the water
pump
B. Tighten and block
the air leakage
parts
A. Adjust or replace
bottom valve
B. Clean or replace
water input pipes
C. Reduce water input
hight