Perancangan Over Head3
Perancangan Over Head3
=
=
=
=
=
=
=
Lebar
Portal Crane
30
32.5
12
13
16
15
ton
ton
m
m
m
m
294000
318500
12000
13000
16000
15000
N
N
mm
mm
mm
mm
//Trolley Frame
1
Bahan
Material Baja Konstruksi
b =
SF =
a =
1000 mm
400 N/mm2
4
100 N/mm2
M max =
( P.L ) / 4
Perhitung
Maka
Mmax
Modulus
Mmax =
231769078 N/mm3
231.7690781 N/mm2
=
Berat Keseluruhan Trolley Frame Adalah :
V = A x Ltotal Leg
Berat Jenis Baja =
A = Luas =
L total Leg =
Volume profil=
Berat Total =
=
7.81 Ton/m3
0.004704 m2
1m
0.004704 m3
0.03674 Ton
360.4021344 N
0.0008779132 m
0.87791 mm
Dengan batasan :
defleksi max ()
L/1000
mm
1 mm
39812.5 N.m
//GIRDER
b ( material baja konstruksi )
a
SF
=
=
=
400 N/mm^2
100 N/mm^2
103.938973389
total =
61090.66191
4246.875
65337.53691
640307861.718
64030.7861718
2416 kg
2.416 ton
kgm
kgm
kgm
Nmm
Nm
6403078.6 mm^3
6403.0786 cm^3
5760 cm^3 >
// DEFLEKSI
= P.L^3 / 192 EI
Dimana =
E=
200 Gpa
=
200000000000 N/m2
= Modulus Elastisitas
I=
0.0201 m^4
=
=
0.0013961987 m
1.39620 mm
Dengan batasan :
defleksi max ()
L/1000
mm
25 mm
151 kg/mm
3926 kg
3.926 ton
6403.07861718 cm^3
59.192 N/mm2
= Perhitungan a
= Diizinkan
Diketahui :
a=
b=
c=
d=
200
110
94
184
mm
mm
mm
mm
=
=
=
=
=
9.447712E-006 m4
Modulus Profil
Momen Inertia
=
Jarak Terjauh Sumbu Profil
0.000172 m3
0.2
0.11
0.094
0.184
m
m
m
m
55 mm
80
150
138
68
mm
mm
mm
mm
=
=
=
=
0.08
0.15
0.138
0.068
m
m
m
m
100 mm
Momen Inertia
(1/12 x a x b3 )
Modulus Profil
- ( 1/12 d x c3) =
7.61E-06 m4
=
7.61E-005 m3
Momen Inertia
=
Jarak Terjauh Sumbu Profil
Berat Keseluruhan Leg Adalah :
V = A x Ltotal Endcarriege
Berat Jenis Baja =
A = Luas =
L total Endcarriege =
7.81 Ton/m3
0.002616 m2
2.2 m
Volume profil=
0.01 m3
Berat Total =
0.045 Ton
440.941
200
260
244
184
mm
mm
mm
mm
=
=
=
=
0.2
0.26
0.244
0.184
100 mm
Momen Inertia
(1/12 x a x b3 )
Modulus Profil
- ( 1/12 d x c3) =
Momen Inertia
=
Jarak Terjauh Sumbu Profil
Berat Keseluruhan Leg Adalah :
V = A x Ltotal Endcarriege
Berat Jenis Baja =
A = Luas =
L total Endcarriege =
Volume profil=
Berat Total =
7.81 Ton/m3
0.007104 m2
2.2 m
0.02 m3
0.122 Ton
0.000702 m3
m
m
m
m
7.02E-05 m4
Bahan
a =
SF =
b =
Dimana =
P = SWL + over loading + W. Trolley frame
=
32.53673824 ton
= 318860.034752 N
79715.0087
L=
1.5 m
Mmax
L2
Maka
Dimana
Mmax =
P=
16.26836912 ton
159592.701067 N
=
L=
a=
b=
W=
perhitungan =
18849.24998255 N.m
2m
0.25 m
1m
0.04 ton
W.L2
12
146.9803
P.a.(a+b)2
62340.9
P.(a+b).a
12468.18
=
Mmax
Modulus
440.9 N
=
247768939 N/m2
247.77 N/mm2
Dengan Batasan y =
2 mm
Dimana P :
=
=
L=
SWL + over loading + W. Trolley frame + Cross travel End truck + Girder
37.490799168 ton
367409.8318464 N
2 m
Mmax
Maka
Dimana
L2
Mmax =
P=
=
31546.7915976 N.m
18.745399584 ton
183892.369919 N
L=
a=
b=
W=
3m
0.5 m
1m
0.12 ton
perhitungan =
=
Mmax
Modulus
Dengan Batasan y =
3 mm
898.0633
P.a.(a+b)2
206878.9
P.(a+b).a2
68959.64
1197.4 N
=
=
W.L2
12
44945293 N/m2
44.95 N/mm2
a =
P
A
Mc
I
P.e.(h/2)
(b.h3)/12
a = 114932731.199 N/m2
= 114.932731199 N/mm2
Dimana P :
=
=
L=
SWL + over loading + W. Trolley frame + Cross travel End truck + Girder
37.612860096 ton
368606.0289408 N
8 m
Mmax
L2
Maka
Dimana
Mmax =
P=
18.806430048 ton
184491.078771 N
=
L=
a=
b=
W=
231281.0445251 N.m
5m
2m
1m
0.48 ton
perhitungan =
=
96.8
484
0.484
1490
0.00149
Mmax
Modulus
Dengan Batasan y =
5 mm
9891.75
P.a.(a+b)2
3320839
P.(a+b).a
2213893
4748.0 N
kg/m
kg
ton
cm3
m3
=
=
W.L2
12
155222178 N/m2
155.22 N/mm2
//SISTEM PULI
Perencanaan Tali Baja
// Sistem Puli (4/1)
n
SWL+25% over load (Q)
=
=
=
3
12500
1.05
kg
Q . ( 1 )
n+1
= 3357.284
1 )
kg
dimana, b
E
k
D/d
i
=
=
=
=
=
maka, P
Zx b
b
E
d
.
k 1. 5 i D
16000
800000
5
30
114
kg
kg/cm2
.
5,5
1. 5 114 30
= 34995.43 kg
=
35000 kg
dari tabel pemilihan diameter tali baja jenis 6 x 19(9/9/1)
didapat diameter tali baja = 24 mm dan beban putus = 37000 kg
// Diameter puli
puli
// Diameter drum
drum
= 20 x tali baja
480 mm
=
=
30 x tali baja
720 mm
=
=
6.25
rpm ( N )
C
x n1
0.1333
3,14 x 720 x 1000
2.765
=
Beban ( F )
Torsi (T)
2xZ
2 x 3357. 284
6714.5674429396 kg
65869.9066152374 N
=
=
=
FxR
65869,91 x 1
65869.9066152374 Nm
19059.579
19.06
Daya efisien
dimana,
sf
=
=
=
=
=
=
rpm
=
=
=
=
=
=
m/min
720 mm
watt
kW
P
x sf
kW
3660 x 60
2 x x 1000
303.50
Nm
x 1,25
=
=
=
=
=
Motor
Reduction Gear
C
SF
gear
=
=
=
=
=
>> Motor
kW
RPM
m/menit
%
mm
1.5
3,14 x 100
6.3694
put/menit
=
=
=
=
2.Z
2 x 17533,87
7316.96
71706.21
kg
N
=
=
=
F.R
113482,81 x 0,05
3585.310318464 Nm
=
=
8
800
1:25
2
80
1.25
1100
2390.207
2.390
watt
kW
3.73
kW
=
=
=
SWL
12500 kg
1250 kg
>> Motor
Daya
Reduction Gear
C
SF
gear
=
=
=
=
=
8
1000
1:25
2
80
1.25
120
kW
RPM
m/menit
%
mm
=
F
5.308 put/menit
=
=
=
=
2.Z
2 x 1250
=
=
=
F.R
78400 x 0.055
=
=
2500 kg
24500 N
1470 Nm
816.6666666667 watt
0.8166666667 kW
1.276 Kw
12.191 Nm
(10% Z)
(10% dari Z)
=
=
= ( 5,1 x T/a)1/3
=
560020.326778 kg.mm
80.38 mm
Dimana
127.59 mm
Material SS55C
b =
66 kg.mm2
Sf1 =
6
Sf2 =
2
Kt =
2 Tumbukan Besar
Perhitungan poros berdasarkan beban puntir
a = b/(Sf1 x Sf2)
=
5.50 kg.mm2
Km =
2 Tumbukan ringan
Kt =
Cb =
2
2
237 mm
untuk l/d pada bantalan rotor lebih baik antara 1,0 - 2,0
l/d =
1
l = 237.1377 mm
maka panjang bantalan yang aman =
237 mm
Dari Beban radial
d ( 5,1 x W x L / a )1/3
dimana :
32466.87 kg
237
mm
1
kg/mm2
// Flange Wheel
Control System