INSPECTION VISIT REPORT

No.: MB/2016/015
Date-15/07/2016

TV-SD South Asia Pvt. Ltd., INDIA


230A,ChitrakootBuilding
A.J.C. Bose Road
Space-24
Kolkata-700020
West Bengal
India.

INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET
INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET
INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET
INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET
INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET
INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET
INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET
INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET
INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET
INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET
INCLUDEPICTURE
"cid:image004.jpg@01C93
07F.E3860200" \*
MERGEFORMATINET

Doc. No. TSSA_IS_IN_FR_04 Rev.1Dt. 01-02-16


For any suggestions/complaint please write to Quality.Industryservices@tuv-sud.in

1.

TV Ref. No. / Job File No.

2.

Name of Owner

:
:

3.

Consultant

IND-008103
Bharat Petroleum Corporation Limited. Kochi.
--

4.

Project

BPCL Kochi Project.

5.

EP Contractor

Offshore Infrastructures Ltd

Buyer: M/S Offshore Infrastructures Ltd

Buyer/Supplier

6.

Supplier: M/S Polybond Insulation Pvt Ltd.

7.

Purchase order / L.C.No

8.

Scope of Inspection

As per QAP Number: 1.OIL/3104/QAP/002 REV 00 Date: 20.01.2016.

9.

Material offered

As per annexure A.

10.
11.
12.
13.

Contacted person
Place & Date of attendance
Time in :-10.00 AM
SPECIAL REMARKS :-

:
:

Mr. Praveen Thulkar. ( 09993754565 )

14.

All equipments/instrumentsused by customer/vendor during inspection are verified for suitability by having accreditation to
ISO/IEC 17025 for the relevant tests, range accuracy and calibration validity. OR
Equipment is suitable in
Equipment calibrated
Facilities & Environmental
YES/
YES/
YES/
terms of range, least count,
traceably to national or
conditions for measurement are
NO
NO
NO
accuracy
iinternational standards
maintained
Unique identification of
YES/ Use of equipment by
YES/ Validity of Calibration
YES/
equipment
NO
competent person
NO
NO
Stamped / Punched / Stenciled / Stickered (for identification only):TUV SUD Stamp Sticker put on inspected
items as

15.

OIL/3104/16-17/PP/07/0335 Dated:05/07/2016

Polybond Insulation Unit I Bhilai& Unit II Rasmada Date: 14/07/2016 & 15/07/2016

Time Out :-5.30PM

for identification only.

Result of Inspection :-

Remarks

Conform / Satisfactory
Not Conform
Accepted under Deviation (with written document from Purchaser mandatory)
Pending for Further Work in progress
a) Testing/Painting / Finishing / Packing / Marking -16.

X
X
X

This inspection is valid for 60 days from the date of inspection.

Companys
representative

For TV-SD South Asia Private Limited

Name: Mukul Bain


Mobile: +91 9831953344
Email: Mukul.Bain@tuv-sud.in

(Name & Signature)


TV-SD South Asia Pvt. Ltd., INDIA
230A,ChitrakootBuilding
A.J.C. Bose Road
Space-24
Kolkata-700020
West Bengal
India.

INSPECTION VISIT REPORT


No.: MB/2016/015
Date-15/07/2016

(A) Reference Document :1.


2.
3.
4.

PO No: OIL/3104/16-17/PP/07/0335 Dated:05/07/2016


OIL/3104/QAP/002 REV 00 date: 20.01.2016
IS 8183: 1993 & IS 9842: 1994
EIL Spec :6-44-0002 Rev 05.

Doc. No. TSSA_IS_IN_FR_04 Rev.1Dt. 01-02-16


For any suggestions/complaint please write to Quality.Industryservices@tuv-sud.in

(B) Detail of Inspection Activity: 1. Identification and Marking visually checked for Pipe sections, packed inside corrugated box for protection &
found acceptable as per specification.
2. Sample were selected randomly as per relevant specification.
3. Visual, Dimensional & Bulk density check witnessed on selected samples and found acceptable.
4. Recovery after compressions, Linear shrinkage, compressive strength, shot content, Incombustibility,
Sulpher content, Alkalinity witnessed on 14.07.2016 at manufacturer laboratory at Bhilai and the result found
within specified limits as per Material specification and EIL specification.
5. Chloride content tests witnessed on 15.07.2016 at manufacturer laboratory at Bhilai and found acceptable as
per QAP, Material Specification and EIL Specification.
(C) Document Reviewed : Below mentioned documents are reviewed and found in order.
1.
2.
3.

Internal Inspection reports.


Manufacturer / Raw Material test certificates.
Thermal Conductivity Test report.

(D) List of Calibration instruments: 1.


2.
3.

Steel Tape.
Steel Scale
Weighing Machine.

(E) Conclusion:1.

Offered material is accepted as per above mentioned checks and tests.

(F) Enclosure :1.


2.
3.
4.

Internal Inspection reports.


Manufacturer Test certificates.
Witnessed Test report.
Calibration certificates of measuring instruments.

Companys
representative

(Name & Signature)

For TV-SD South Asia Private Limited

Name: Mukul Bain


Mobile: +91 9831953344
Email: Mukul.Bain@tuv-sud.in

Date: 15.07.2016

ANNEXURE: A
Doc. No. TSSA_IS_IN_FR_04 Rev.1Dt. 01-02-16
For any suggestions/complaint please write to Quality.Industryservices@tuv-sud.in

PIPE SECTION

SL No.

P.O. Sl.
No.

Dia (Inch)

THICK
(MM)

Total Ord.
Qty. (RMT)

Prev. Insp.
Qty. (RMT)

Offered Qty.
(RMT)

1.50

55.0

1000

500

500

2.00

25.0

325

325

3.00

55.0

450

200

250

6.00

55.0

1500

300

1200

8.00

25.0

700

200

500

12.00

25.0

2350

150

2200

6325

1675

4650

Doc. No. TSSA_IS_IN_FR_04 Rev.1Dt. 01-02-16