OLYMPUS Stream
For Materials Science Microscopes
Easy-to-read toolbar
for all major functions
My Function
You can create intuitive workows
based on the most frequently used
functions, simplifying repetitive tasks
so that even new users are able
to operate the software easily and
efficiently.
Image Acquisition
Measurements
Place your sample on the system and adjust the optics for
a crisp image.
Microsoft Office
Integration
OLYMPUS Stream offers complete
integration with Microsoft Word and
Microsoft PowerPoint.* This allows for
the creation of professional reports
and presentations accommodating
your company templates including
your own headers and footers.
OLYMPUS Stream uses a dedicated
menu and toolbar that is integrated
into your preferred Microsoft Office
package for an improved image
handling experience. Tables and
graphs can also be easily exported
into Microsoft Excel for extended
processing. Due to a unique
compression method, OLYMPUS
Stream ensures your report les are
a reasonable size for easier data
exchange by email.
*Microsoft PowerPoint Assistant is optional
Particle Analysis
Report Generation
HDR Capability
HDR (High Dynamic Range) offers an exceptional level of contrast for microscopic images containing both bright, highly
reective features as well as darker low-reective features. As an integral part of OLYMPUS Stream software, the HDR
algorithms automatically acquire a series of images at varying exposure times. Within seconds create a composite image
perfectly exposed at every level. This is especially useful for metallurgical microstructures, printed circuit boards, or composite components. HDR imaging is also offered when acquiring stitched, panoramic (MIA) images, or when using the built
in Extended Focal Image (EFI) capability to create an image with focus even with varying heights.
Digital Reticle
Autofocus
Automatic MIA/EFI
For precise sample focusing and fast image acquisition, OLYMPUS Stream offers two autofocus options. For
surfaces with high contrast, OLYMPUS Stream can use its
contrast-based software autofocus. For surfaces with low
contrast, such as polished or transparent materials, the optional laser autofocus unit is a fast, repeatable option when
integrated with the Olympus BXiS microscope system.
Both systems provide perfectly focused images with the
simple click of a button.
Macro Recorder
Tilt Compensation
OLYMPUS Stream provides a way to preset complex imaging and measuring tasks with the Macro Recorder. The
Macro Recorder creates step-by-step processes, that after
completion, are stored and then implemented with a single
click. The capability ensures different operators are using
the same settings for a consistent output.
Coin detail
Surface View
By using the motorized focus unit, samples with different heights can be imaged automatically. In addition, a 3D image
can be created that can be measured using the z-stack data.
*For the appropriate main license for this solution, please refer to the specication table at the end of the brochure.
Arithmetics
Image Processing
OLYMPUS Stream has a variety of lters for edge detection, smoothing, and other purposes. You can visualize image
features by enhancing and modifying your image with a processing lter. For best results, you can check or adjust the lter
results in a preview display before making the change. Additionally, image manipulations such as sum, subtraction and
erosion are also carried out without losing your original image.
Measurement operation
Basic Measurement
Magic Wand
Measurement Result
Included with the OLYMPUS Stream Basic package and
other more advanced packages is an integrated data analysis package. The data analysis provides statistical analysis
on your data based on your needs. You can calculate
mean, standard deviation, min, max, and more. All of the
data gathered is exported to Microsoft Excel with a single
click.
Layer Management
Each image as it is captured and annotated is broken into
layers (original image, measurement data, annotations etc.),
allowing you to change processing les (smoothing and/
or sharpening) without affecting your measurement results.
You can easily retain your measuring data as you carry out
your analysis and measurements.
Traceability
For quality control and traceability recording the conditions
of image acquisition is essential. With OLYMPUS Stream,
you can quickly create a calibration report for important
information such as magnication, objective lens type, pixel
size, scale bar, etc. The Info Stamp created from updated
calibration information can be overlaid on the acquired
image and reports.
Original image
Measurement: A-throat
Weld Measurement
OLYMPUS Stream offers an optional set of measurements dedicated to the measurement of geometric distortion induced
by the heating during welding. Asymmetry, Multiple Perpendicular Lines and A-Throat measurements can be conducted
with a few simple clicks. This allows detailed and statistical measurements of the welding distortion. These measurements
are perfect for assessing the quality of the weld.
*For the appropriate main license for this solution, please refer to the specication table at the end of the brochure.
10
11
Acquire Image
Process Image
Analyze Image
Create Report
Particle Distribution
Coating Thickness
Mineral compound
Phase Analysis
Porosity
13
Grains Intercept
Grains Planimetric
Inclusion
Chart Comparison
Cast Iron
Layer Thickness
Wafer pattern
Throwing Power
Automatic Measurement
DP21
DP26
This high-resolution 5M-pixel color CCD camera provides
optimum true color performance for all industrial applications and imaging techniques. The DP26 incorporates high
speed progressive scanning with IEEE1394b connectivity.
Available
Olympus recommendation
Universal model
Outstanding performance
n/a
Standard model
First-rate Flexibility
Stand-alone
model
Introductory model
For standard applications
Cost performance
DP73
XC10
DP26
UC30
SC30
DP21
Image sensor
1/1.8 in.
Color CCD
2/3 in.
Color CCD
2/3 in.
Color CCD
1/1.8 in.
Color CCD
1/2 in.
Color CMOS
1/1.8 in.
Color CCD
17.3*1
1.4
5.0
3.2
3.3
2.0
27~15
50~15
31~7
35~7
49~10
27~15
ADC*2
14 bit
14 bit
12 bit
14 bit
10 bit
12 bit
Bright condition
(e.g. Brighteld)
Thresholding analysis
(B/W mode)
Observation
Measurement
/ Analysis
*1 Pixel-shift
*2 Analog-to-digital converter. Actual bit depth of the camera depends on software used.
Projection
magnications
Video camera
adapter
XC10
DP26
UC30
SC30
DP21
1X
U-TV1XC
8.8
11.0
11.0
8.8
8.0
8.8
0.63X
U-TV0.63XC
14.0
17.5
17.5
14.0
12.7
14.0
0.5X
U-TV0.5XC
17.6*3
22.0*3
22.0*3
17.6
16.0
17.6
0.35X
U-TV0.35XC
22.0*3
*3 Insufficient peripheral light intensity or vignetting may be distinct depending on optical system.
Practical Field of View (mm) = Projection Area (eld number) / Objective Lens Magnications
Actual camera sensitivity is dependent on the level of light reectance from the sample. This level of light reectance is dependent on observation method chosen and sample material.
15
Space saving
LM laboratory
Job processing
Production
EM laboratory
Management
Server
LIMS
Intake Control
QA
Stream
CRM
Data Management
Windows 8
Microsoft Windows 8 (32bit/64bit) is the new standard in
operating systems. OLYMPUS Stream fully utilizes all of the
advanced capabilities for your everyday tasks.
* Microsoft Windows XP, Windows Vista, Windows 7 are also supported.
16
Motion
Motion
Time lapse
Write and read all major le formats and open Olympus proprietary formats (DSX, LEXT,
and VS le formats)
Scale bar (X, Y, and XY), crosshair and info stamp display
Basic
: Standard
: Optional
Start
Essentials
Main Licenses
IMAGE ACQUISTION
Basic image acquisition
Extended image
acquisition
Advanced motorized
image acquisition
IMAGE TOOLS
Surface View
CUSTOMIZATION
Basic customization
Extended customization
*5
Macro manager
IMAGE ANALYSIS
Calculates many selectable parameters (diameter, size, color, grey level, ...) on
segmented particles on the image. Creates graphical representation of the results with
histograms and scattergrams.
Phase analysis (Materials Calculates area and area fraction with ROI*2 support. Includes the capability to perform
solution)
automatic measurement on multiple stage locations*3
Count & measure
Materials Solution
*4
*5
INTERACTIVE MEASUREMENT
Basic measurement
Distance, angles, rectangles, circles, ellipses, polygons, circle to circle distance and
angle ruler
Weld measurement
REPORTING/PRESENTATION
Report Composer
Detail zoom
Read existing analysis report format (*.src) and create workbook and chart based on
Olympus le format
Integration of OLYMPUS Stream images (gallery, database and other sources) into
Microsoft PowerPoint presentations
Document types
Presentation
DATA MANAGEMENT
Data management
utilizing Microsoft SQL
Server Express
DEVICE SUPPORT
Olympus microscopes
Olympus camera
Non Olympus camera
Imaging source converter DFG-1394 A-D (CON 800) analog to digital converter (Firewire or USB 2.0)
Stage controllers
*1
XYZ stage controllers from Objective Imaging, Prior ProScan, Ludl MAC, Mrzhauser,
ITK and LANG
Requires Olympus microscope with motorized Z-axis or external motorized Z-axis (Supported by OLYMPUS Stream Motion)
Rectangle, circle, triangle, polygons, and magic wand
Multiple Stage Location and Sample Alignment are available for Phase Analysis, Grain Size Measurement, Inclusions Worst Field, Porosity, Particle Distribution, and Automatic Measurement
*4
Please see page 18 and 19 for further information.
*5
Throwing Power is not available for Desktop License.
*2
*3
17
Count & classify detected particles in bins and extract statistical values of the population
Supported standards
User dened
Particles are dened using simplied threshold settings
Automatic classication according to a selected parameter (size, color or shape)
Measurement on ROIs and multiple thresholds
Denition of validation and coding according to user dened standards
Support of Multiple Stage Location and sample alignment (with OLYMPUS Stream Motion)
Class histogram and spreadsheet with individual measurements. Report automatically created in Microsoft Word
Measurement types
Output
COATING THICKNESS
Description
Semi-automatic measurement of coating thicknesses from prints created by the calotest method
Supported standards
EN1071-2:2002, VDI3824:2001
Prints are measured from top view
Calculation of the coating thickness according to the sample geometry
Spreadsheet with individual measurements. Report automatically created in Microsoft Word.
Measurement types
Output
PHASE ANALYSIS
Description
Measurement types
Output
POROSITY
Description
Measurement types
Output
Measures the area fraction, density and number of pores on steels castings
Pores detection per ROIs (Triangle, circle, rectangle or polygon) with overlapping capability
Measurement of the pores density, count and specic area.
Measurement of the biggest pore
Measurement on a specied size range
Support of Multiple Stage Location (with OLYMPUS Stream Motion)
Spreadsheet with individual measurements. Report automatically created in Microsoft Word.
GRAINS INTERCEPT
Description
Supported standards
ASTM E112, GB/T 6394, GOST 5639, ISO 643, DIN 50601, JIS G0551, JIS G0552
Selection of pattern (Circles, Cross, Cross & Circles, Vertical Lines, Horizontal Lines, Horizontal & Vertical Lines)
Denition of the number of test lines for determination of grain elongation
Displays the G-value in the Material Solution Tool Window
Stores all results in the image property for additional data mining
Support of Multiple Stage Location (with OLYMPUS Stream Motion)
Spreadsheet with individual measurements. Report automatically created in Microsoft Word.
Measurement types
Output
GRAINS PLANIMETRIC
Description
Supported standards
ASTM E112, GB/T 6394, GOST 5639, ISO 643, DIN 50601, JIS G0551, JIS G0552
Automatic extraction of grain boundaries
User interaction using Stream sliders for improved usability
Displays the G-value histogram in the Material Solution Tool Window for direct interaction
Stores all results in the image property for additional data mining
Support of Multiple Stage Location (with OLYMPUS Stream Motion)
Spreadsheet with individual bins measurements, Stream chart with the distribution. Report automatically created in Microsoft Word.
Measurement types
Output
CHART COMPARISON
Description
Allows the user to compare live or selected images with standard charts
ASTM E112, ISO 643:83 & ISO 643:03, DIN 50602, ISO 945, SEP 1520, SEP 1572 and EN 10247/07 (sold under license from copyright
Supported standards (Option)
owners)
Multiple displays available, including live overlay
User interaction using Stream sliders for improved usability
Measurement types
Calculates statistics on the selected values
Stores all results in the image property for additional data mining
Output
Spreadsheet with individual measurements
*Installation of .NET Framework3.5 with Windows Installer is required when you use Windows 8.
Measurement types
Output
Measures the non metallic inclusion rating in steel using the worst eld method
ASTM E45 Method A, DIN 50602 Method M, ISO 4967 Method A, GB/T 10561 Method A, JIS G0555 Method A, UNI 3244 Method M,
EN10247
Automatic detection of non metallic inclusion using colors, shape and size
Automatic classication of oxides, suldes, silicates and aluminates
Live display of the detected inclusion with its rating
Stores all results in the image property for additional data mining
Support of Multiple Stage Location (with OLYMPUS Stream Motion)
Spreadsheet with individual measurements. Report automatically created in Microsoft Word.
CAST IRON
Description
Measures the distribution, shape and size of graphite content in cast iron samples
Supported standards
EN ISO 945-1, ISO/TR945-2, ASTM A247, JIS G5502, KS D 4302, GB/T 9441 and ASTM E2567-11
On polished samples: Automatic measures the characteristics of the graphite content (Size, Shape and Distribution)
On etched samples: Measures the ferrite to pearlite ratio
Integrated workow which take into account the sample status (etched or polished)
Stores all results in the image property for additional data mining
Spreadsheet with individual measurements. Report automatically created in Microsoft Word.
Measurement types
Output
18
Measurement types
Layer boundaries can be specied using automatic detection, magic wand or manual mode (using 2 or 3 points).
Individual measurements can be added or deleted later on.
Measurement of any type of layers (with even or uneven boundaries) is supported.
Layer thickness measurement calculates mean, maximum and minimum values as well as statistical data for each individual layer.
Output
THROWING POWER
Description
Measures the distribution of copper plating thickness in through-holes or microvias in printed circuit boards.
Measurement types
Output
AUTOMATIC MEASUREMENT
Description
Create complex measurement sequence by automatic edge detection and pattern recognition.
Measurement types
Automatically measure distances (point to point, point to line, circle to circle, point to circle, line to circle)
Automatically measure circle diameter (roundness, bounding box)
Automatically measure angles between two lines
Denition of tolerances values for measurement and visual validation
Expert and User mode for improved security
Support of Multiple Stage Location and sample alignment (with OLYMPUS Stream Motion)
Output
Measurement types
Multiple threshold methods are available (automatic, manual HSV, manual and adaptative). The system can automatically measure multiple
parameters on all segmented objects (Area, Aspect Ratio, Bisector, Bounding box, Gravity Center, ID, Mass Center, Intensities Values,
Convexity, Diameters, Elongation, Feret, Extent, Next Neighbor Distance, Orientation, Perimeter, Radius, Shape, Sphericity ...).
Output
WELD MEASUREMENT
Description
Measurement types
Output
SURFACE VIEW
Description
Displays a 3D perspective of an image stack acquired with a motorized Z. (available with Stream Motion)
Display
Output
The result image can be exported. Animation can also be created automatically.
PC Requirements
CPU
Intel Core series 1.8 GHz or higher (Intel Core i5-650, 3.2 GHz recommended)
RAM
Hard disk
DVD drive
DVD+R DL compatible
OS
Windows XP Professional SP3 (32 bit) / Windows Vista Business, Ultimate SP2 (32 bit) / Windows 7 Professional (32 bit/64 bit)* /
Windows 8 (32 bit/64 bit)*
Graphic card
* DP20/DP70 dose not support Windows 7 (64 bit) and Windows 8(32 bit/64 bit). DP73 supports only Windows 7 (64bit).
U"9*1-
",*",/" -"-"{Vivi`
^^^VS`TW\ZPTZJVT
UV>>``V>i>ii}ii`>`i>>`>`i>viiiVii
U>}ii*
>i>i`
U-iVvV>>`>i>>Vi>iLiVV>}i>ViL}>i>vi>v>Vi
159 Serm-Mit Tower, 9th Floor, Unit # 906-910, Sukhumvit 21 Road, North Klongtoey, Wattana,
Bangkok 10110, Thailand
10F, K. Wah Centre, 1010 Huai Hai Road (M), Xuhui District, Shanghai, 200031 P.R.C.
102B, 1st Floor, Time Tower, M.G. Road, Gurgaon, Haryana-122001, India
Olympus-Tower, 114-9 Samseong-Dong, Gangnam-Gu, Seoul, 135-090 Korea
3 Acacia Place, Notting Hill VIC 3168, Australia
M1725E-102013