Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo

History:

1864
1868

1909
1930
1943
1967

1968

1971

Foundation
Manufacture of the first european positive displacement
blower
 more than 130 years of experience!!!
The Aerzen workshops supply blower no. 10.000
Production start for rotary piston gas meters
Production start for screw compressors
Development and supply of special screw compressors
for air compression
Serial production of oil injected screw compressors
for refrigeration industry
Development and supply of oil injected screw
compressors for compressed air industry

Aerzener Maschinenfabrik GmbH

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo

1978

The worlds largest positive displacement blower


(conveying volume 84.000 m/h) built for steel
production

1984

The worlds largest screw compressors (conveying


volume 65.000 m/h) built for and supplied to
chemical industry

1987

Aerzen develops positive displacement blowers


with internal pulsation dampening

1989

Blower no. 250.000 ready for delivery

Aerzener Maschinenfabrik GmbH

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Aerzen Positive Displacement Blowers

Aerzen Positive Displacement Blowers of standard design


GM 3S bis GM 1080L, DN 50 up to DN 800
22 sizes, intake volume flows from approx. 30 to 65.000 m/h
p = max. 1000 mbar

Aerzen DELTA BLOWER (blower units of standard design)


3-lobe type blowers, GM 3S bis GM 240S, DN 50 up to DN 400
16 sizes, intake volume flows from approx. 30 to 15.000 m/h
max. p = 1000 mbar pressure service, max. - 500 mbar vacuum

Aerzen bulk vehicle blowers


4 sizes, intake volume flows from approx. 600 to 2.250 m/h
p = 1000 mbar, 1200 mbar max. dsign, up to max. - 500 mbar vacuum

Aerzener Maschinenfabrik GmbH

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Operating range of Aerzen blowers and screw compressors

DELTA SCREW series


DELTA BLOWER series

Aerzener Maschinenfabrik GmbH

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Rangeof
ofapplication
applicationof
ofAerzener
AerzenerPositive
PositiveDisplacement
DisplacementBlowers
Blowers
Range

Sewage water
technique

Aeration

basin

Water
treatment

Pneumat.
transport

Ventilat.
Rivers/
Lakes

Vacuum
operation

Aerzener Maschinenfabrik GmbH

Chem./ foodstuff indus

Gas
supply

Chem./process
gas industry

Vacuum
technique

Sewage
gas

Oxidation
air

Grit
chamber

Filter
flushing

Flue gas
desulfurization

Increase
of gas
pressure
Bulk
goods

Techn.
gas

Mixed gases

Pump stands

Pressure
operation

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Mech. - biological sewage treatment
Mechanical stage
Grit chamber

Oil and grease trap

Primary settlement tank

Waste water
Screen
Sludge

Biogas

Aeration by
Aerzen PD
blowers

Aeration basin

Fowling tower

Secondary settlement tank

Gas reservoir

Treated water
Aerzen PD blowers
(biogas arrangement)
for the gas supply to
the gas motor or
burner

Aerzener Maschinenfabrik GmbH

Sludge
Biological stage
Oxidation air (O2) by Aerzen PD
blowers or screw compressors

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Waste water treatment application

Screen

waste water

Aeration
basin

Grit chamber

Clarification

treated water

air
air (O2)

Plant`s structure of costs


1.) Costs of investment
2.) Power consumption
Appr. 60% of the energy
Consumption of the aeration
system

Aerzener Maschinenfabrik GmbH

3.) Costs for maintenance / repairs

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Waste water treatment application

Aerzen Blowers for the aeration of the biological part and the grit chamber
Aerzener Maschinenfabrik GmbH

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Waste water treatment application

Distribution of air in the aeration basin


Aerzener Maschinenfabrik GmbH

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Waste water treatment application

Usual blow in depths:


municipal plants 4...8 mWS
industrial plants 10...20 mWS

Blow in depth

Aerzener Maschinenfabrik GmbH

basin

10

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Waste water treatment application
pressure
increase
dirty

diffusor

clean
pressure loss piping
blow in depth

Demand on pressurized
air:
air flow

By pollution of the diffusor system the


pressure can increase by 20% !

Aerzener Maschinenfabrik GmbH

11

oil free

stable performance curve

ability of flow control

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Waste water treatment
application

Why is the air flow to be


controlled ?

O2 content in the aeration basin


4
3,5
3

mg O2/l

2,5
Reihe1

2
1,5
1
0,5

00
:0
0

22
:0
0

20
:0
0

18
:0
0

16
:0
0

14
:0
0

12
:0
0

10
:0
0

08
:0
0

06
:0
0

04
:0
0

02
:0
0

daytime

Aerzener Maschinenfabrik GmbH

12

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Waste water treatment application

Delta Blower GM 3S for the aeration of the grit chamber


Aerzener Maschinenfabrik GmbH

13

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Waste water treatment application

Delta Blower Gen. 5, GM 60S in STP Sports City Dubai, UAE


Aerzener Maschinenfabrik GmbH

14

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo

Subjects
1. Blower and DELTA BLOWER
- Operating ranges of Positive Displacement Blowers and Srew Compressors
- Range of application of Aerzen Positive Displacement Blowers
- 3-lobe blowers with pre-inlet channel, working principle
- History of Aerzen blower units
- Package Delta Blower: advantages, scope of supply, modifications
2. Delta Blower Generation 5
- Noise study
- Construction of units, constructive modifications
- Advantages and customer benefit
- Possibilities to deliver
- Possible modifications
3. ATEX-solutions from Aerzen
Aerzener Maschinenfabrik GmbH

15

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo

The third dimension of


air conveyance

Aerzener Maschinenfabrik GmbH

16

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo

Conveying cycle of a two-lobe blower

Aerzener Maschinenfabrik GmbH

17

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo

Conveying cycle of a two-lobe blower


4 partial conveying gas
volumes per revolution of
the drive shaft

The PD blower operates acc. to the displacement principle without internal


compression (only isochore ), therefore the counter system pressure only
determines the amount of compression and consequently the power consumption.
Alteration of volume flow can only be achieved by speed control.

Vibrations and pulsations !


Aerzener Maschinenfabrik GmbH

18

Bombas Bornemann S.R.L.

blower
units
Seminario sobre Seleccin deAerzen
Equipos
y Mantenimiento
Preventivo

Lp12 = Lp1 + Lp2 (2-lobe)

Lp1: Sqeeze-impuls
Lp2: Pressure-impuls 2-lobe

Aerzener Maschinenfabrik GmbH

19

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo

Aerzens Patent

The application of the Interference process to


the construction of rotary lobe blowers has
been patented by the Aerzener
Maschinenfabrik under the registration
number DE 3527292 C2

Aerzener Maschinenfabrik GmbH

20

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Conveying cycle of a three-lobe blower

6 partial conveying gas


volumes per revolution of
the drive shaft

Intake
Gas enters the open
conveying chamber of
the blower via the
intake opening
Aerzener Maschinenfabrik GmbH

Conveying cycle
By rotors`rotation closing of the
intake opening and displacement of
the conveying gas volume to
discharge side is proceeded.
21

Outpouring
The rotor opens the discharge
socket, the conveying gas
volume is pushed into the
system.
Bombas Bornemann S.R.L.

blower
units
Seminario sobre Seleccin deAerzen
Equipos
y Mantenimiento
Preventivo

Lp12 = Lp1 + Lp2 (2-lobe)


Lp13 = Lp1 + Lp3 = 0 (3-lobe)

Lp1: Sqeeze-impuls
Lp2: Pressure-impuls 2-lobe
Lp3: Pressure-impuls 3-lobe
Aerzener Maschinenfabrik GmbH

22

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages of the 3-lobe-blower
with pre-inlet channels

Pulsations are cancelled directly in the blower stage


The vibration loading of the bearings, timing gears and casing is
much more lower than regarding a two-lobe-blower
The noise energy in the discharge piping is about 25 dB lower
Lower investment outlays for buildings and system components

Aerzener Maschinenfabrik GmbH

23

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Cross sectional drawing of a 3lobe blower GM 35S

Aerzener Maschinenfabrik GmbH

24

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


An Aerzen three-lobe blower.....

Ring retainers....
Sealed by O-rings against shafts
Large neutral chambers to avoid
oil mist leakage into conveying
chamber

Timing gears....
Helical, hardened and ground
Fixed on shaft ends by conicalpress-on taper
Removable by oil pressure

Housing consists of...


Cylinder
Side plates
Gear- and housing cover
Adjusted by conical pins and boltet !
Aerzener Maschinenfabrik GmbH

25

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Inlet and outlet conditions, blower sizing
Intake conditions:
t1 = 40 C
P1 = 1,0 bar abs.
m = 1000 kg/h
 Q1 = 900 m/h

p1 * Q1
T1

Aerzener Maschinenfabrik GmbH

Outlet conditions:
t2 = 104 C
P2 = 1,6 bar abs.
m = 1000 kg/h
 Q2 = 676 m/h

p2 * Q2
T2

26

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Performance curve of blower GM 35S, pressure service

Q1
Pressure service

intake volume flow at


intake pressure
p1 = 1,0 bar abs.
intake temperature t1 = 20 C

p
t
n
P

pressure difference
temperature difference
blower speed
power consumption

Mechanical limits
max. speed
min. speed
max. pressure
max. outlet temperature
max. temperature difference

Aerzener Maschinenfabrik GmbH

27

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Blower sizing

Pth = (nG * q0 * dp) / 600.000

Losses included in PK :
 Pressure loss filter silencer
 Power loss of bare shaft blower
 Pressure loss of base frame
 Pressure loss of non return flap

PK = Pth + PV bare shaft + PV access

Aerzener Maschinenfabrik GmbH

28

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Blower sizing

Pth = (nG * q0 * dp) / 600.000

Losses not included in Pk:


 Belt drive
 Ventilation fan

PK = Pth + PV bare shaft + PV access

Aerzener Maschinenfabrik GmbH

29

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Compressed-air production with positive displacement blowers
Machine selection and design: Evaluation of operating data

Stipulations: QN = 1936 Nm/h


(based on: 1,013 bar abs. + 0 C)
m = 2503 kg/h
Winter operation

Sommer operation
Intake temperature

t1 = 35 C

Intake temperature

t1 = -15 C

Intake pressure

p1 = 1,0 bar abs.

Intake pressure

p1 = 1,0 bar abs.

Relative humidity

RF = 70%

Relative humidity

RF = 70%

Intake volume flow

Q1 = 35,70 m/min

Intake volume flow

Q1 = 30,93 m/min

Aerzener Maschinenfabrik GmbH

30

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Single Circuit control: Continous control of volume flow
with one blower unit
transmitter

power consumtion

controller with
setpoint

aeration basin

frequency
converter

intake volume

Positive displacement blower GM 35S


drive motor with frequency converter
intake volume flow Q1 = 9,1...35,7 m/min
absorbed power at coupling PK = 14...47 kW

Aerzener Maschinenfabrik GmbH

31

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Blower package: demands on the unit
Necessary scope of supply:

Aerzener Maschinenfabrik GmbH

32

Positive displacement blower

Filter silencer

Discharge silencer

Non-return flap

Belt drive

Pressure valve

Flexible machinery mountings

Flexible piping connection

Start-up unloading device

Drive motor

Acoustic hood
Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DELTA BLOWER

Intake filter silencer:


Silencing
2.
Filtering
To avoid pollution of the system
by absorption material
1.

Aerzener Maschinenfabrik GmbH

33

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DELTA BLOWER

Intake filter silencer:


Silencing
2.
Filtering
To avoid pollution of the system
by absorption material
1.

Filter class G4 (EU 4) acc. EN779


Average Filtration efficiency: 92 %
Synthetic material: polyester microfibres
Food-genuinly and regenerable

Aerzener Maschinenfabrik GmbH

34

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DELTA BLOWER

Base frame with integrated


discharge silencer
Reactive type without any absorption
material
To avoid pollution of the system by
absorbtion material
Discharge silencer acc. to pressure
vessel equipment directive 97/23/EG

Aerzener Maschinenfabrik GmbH

35

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DELTA BLOWER

Base frame with integrated


discharge silencer

Aerzener Maschinenfabrik GmbH

36

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DELTA BLOWER

Belt tensioning

Hinged motor support


Aerzener Maschinenfabrik GmbH

37

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DELTA BLOWER

Belt tensioning
Example: Blower GM 150S
Nominal bore DN 300
Motor 200 kW

Totally closed belt guard

Aerzener Maschinenfabrik GmbH

38

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DELTA BLOWER

Start-up unloading valve

....only neccessary, if the motor must be started in Star-Delta


and the blower starts against full back pressure (aeration basin)
Aerzener Maschinenfabrik GmbH

39

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DELTA BLOWER

Compact IV design !
Acoustic hood:
Indoor execution or
Outdoor execution or
Execution for higher noise dampening:
25 dB(A).

Oil level check can be done without


opening of the acoustic hood

Aerzener Maschinenfabrik GmbH

40

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Driving motor
Aerzen motors

Motors acc. to IEC - STD.

Driving motors acc. to IEC and works STD TNO 1159


Name plate:
Aerzener Maschinenfabrik
Operating manual:
4PG-702-D-XU
make: WEG
2 - pole:
1,5....37 kW
make: WEG
45....160 kW
make: WEG
4 - pole:
75....160 kW
Motors should fulfill the stipulations of works STD.
TNO 1159

Extracts from works standard TN0 1159:


Insulation class F
Type of protection IP 55
Junction box on top, cable entry from fan side
Motors must be suitable for frequency converter operation, speed range 1 :3
Admissible radial vibration velocity of rotor: 11 mm/sec
Bearing of the rotors in single row ball bearings
Admissible lateral load: 1,1 x motor weight
Defined regreasing intervals (2000h for 2-pole, 4000 h for 4-pole motors
Nominal bearing lifetime: 25000 h

Aerzener Maschinenfabrik GmbH

41

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo

2006: The new ones there...


Aerzener Maschinenfabrik GmbH

42

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Sound level
Stipulated sound pressure levels: dp = 700 mbar
DN 50

< 65 dB(A)

DN 80

65.70 dB(A)

DN 100

70.73 dB(A)

DN 125

70.73 dB(A)

DN 150

max. 75 dB(A)

DN 200

max. 78 dB(A)

Aerzener Maschinenfabrik GmbH

43

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Noise Study DELTA Blower Generation 5,
GM 7L / 700 mbar
79
78
77

Machine noise Lp(A) [dB(A)]

76
75
74
73
72
71
70
69
68
67
66
65
2

Intake volum e flow Q1[m /m in]


GM 7L/DN 80 brochure
Aerzener Maschinenfabrik GmbH

44

GM 7L-G5/DN 80 measured
Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Noise study DELTA Blower Generation 5,
GM 25S / 1000 mbar
86
Machine noise Lp(A) [dB(A)]

84
82
80
78
76
74
72
70
68
66
5

10

15

20

25

Intake volum e flow Q1[m /m in]

GM 25S/DN 125 Prospekt

Aerzener Maschinenfabrik GmbH

GM 25S-G5/DN 125 gemessen

45

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Sound pressure level of the machine noise by 6...9 dB(A) lower than the previously
documented level
Schallstudie DELTA Blow er Generation 5,
GM 50L / 700 m bar

Maschinengerusch Lp(A) [dB(A)]

84

Customer benefit:

82
80
78
76
74
72
70
68
15

20

25

30

35

40

Ansaugvolum enstrom Q1[m /m in]


GM 50L/DN 150 Prospekt

Aerzener Maschinenfabrik GmbH

GM 50L-G5/DN 150 Messw erte

46

 Reduced sound emission


and -damage to the
environment.
Special acoustic hoods are
not necessary, the
investment charges are
considerably reduced!
Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Simple operation and maintenance: Transport with fork lift truck/stacker lift truck,
the maintenance work oil and filter are effected from the front. The oil level
check can be carried out with running blower.

Main-operation side
Aerzener Maschinenfabrik GmbH

47

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Simple operation and maintenance: Transport with fork lift truck/stacker lift truck,
the maintenance work oil and filter are effected from the front. The oil level
check can be carried out with running blower.

Main-operation side
Aerzener Maschinenfabrik GmbH

48

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Simple operation and maintenance: Transport mit fork lift truck/stacker lift truck,
the maintenance work oil und filter are effected from the front. The oil level
check can be carried out with running blower.

Main-operation side
Aerzener Maschinenfabrik GmbH

49

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Simple operation and maintenance: Transport mit fork lift truck/stacker lift truck,
the maintenance work oil and filter are effected from the front. The oil level
check can be carried out from the outside with running (DN 80....DN 200)

Customer benefit:

 Easy handling of
assembly/commissioning.
The time- and expenditure
for operation and
maintenance work is
considerably minimized.

Aerzener Maschinenfabrik GmbH

50

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DN 50 unit: constructive design

Accessibility
Aerzener Maschinenfabrik GmbH

51

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Hood ventilation by mechanical fan

Customer benefit:

 Considerable reduction of the


investment charges as an
auxiliary drive has not to be
installed electrically.
 In case of ATEX-applications
the Aerzener solution is costneutral as an ex-proof motor
has not to be used.

Aerzener Maschinenfabrik GmbH

52

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Acoustic hoods / Units: Special space-saving design
Customer benefit:

 Smallest possible bases


reduce the space requirement
and consequently the machine
room size. The variant Side
by Side is designed for
special tricky space
proportions.

Aerzener Maschinenfabrik GmbH

53

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


 Acoustic hoods / Units: Special space-saving design

800

800

800

800

GM 10S / DN 100
Delta Blower

GM 10S / DN 100
Delta Blower

GM 10S / DN 100
Delta Blower

1296

1296

1296

required width: 7088 mm

800

GM 10S / DN 100
Delta Blower Gen. 5

GM 10S / DN 100
Delta Blower Gen. 5

GM 10S / DN 100
Delta Blower Gen. 5

1250

1250

1250

Dimensions
shall be as
small as
possible

required width: 4550 mm


Aerzener Maschinenfabrik GmbH

54

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Acoustic hood inlet air (Process and ventilation): at the cold side of the unit,
exhaust air of the hood at the warm side.

Customer benefit:

 Operational reliability !
Optimal ventilation of the unit
also with critical
environmental conditions.

Aerzener Maschinenfabrik GmbH

55

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Acoustic hood inlet air (process and ventilation): at the cold side of the unit,
exhaust air of the hood at the warm side.

Customer benefit:

 Operational reliability !
Optimal ventilation of the unit
also with critical
environmental conditions.

Aerzener Maschinenfabrik GmbH

56

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 The belt re-tensioning is effected really automatically, i.e. without spring construction

Customer benefit:

 After initial installation the


belt tensioning has not to be
controlled any longer.
Saving with installation- and
maintenance costs.

Aerzener Maschinenfabrik GmbH

57

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Driving motor in efficiency class EFF 1, with re-lubricating nipples

Customer benefit:

 Motors with the highest


possible efficiency reduce the
energy costs considerably.
Re-lubricating devices
increase the lifetime of the
motor bearing.

Aerzener Maschinenfabrik GmbH

58

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Discharge silencer and pressure valve correspond to the pressure device guideline
PED

Customer benefit:

 No uncertainties during unit


planning and realization.
Aerzener units fulfill the
stipulated regulation.

Aerzener Maschinenfabrik GmbH

59

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Discharge silencers certified as spark trap: ATEX-applications

Customer benefit:

Positive displacement blowers


show as potential ignition
spark producer a risk area in
many cases of application. At
site, costly spark traps are not
necessary any longer.

Aerzener Maschinenfabrik GmbH

60

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Advantages
 Acoustic hood applicable for indoor- and outdoor installation (modified)

Customer benefit:

 Outdoor installation is
possible on a favourable line
on costs. Reduction of the
investment charges.

Aerzener Maschinenfabrik GmbH

61

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Value analysis
New: different fasteners

Measures.....

New: Front panels reach


ground floor

Aerzener Maschinenfabrik GmbH

62

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


Value analysis
New base frame and
connecting housing,
pressure service DN 100

Aerzener Maschinenfabrik GmbH

63

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DELTA BLOWER : biogas / landfill gas, pressure service
Only available as compact IV, not Generation 5

Options blower:

Options accessories:

Combined rotor chamber sealing

Intake silencer, base frame and pipings made from

Internal parts protected with ChemCoat-Coating

Stainless steel

Aerzener Maschinenfabrik GmbH

64

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


DELTA BLOWER
biogas / landfill gas, pressure service
DELTA BLOWER Package
consisting of:
blower GM 3S.....GM 240S,modified and w. options
intake silencer
base frame with integrated discharge silencer
hinged motor support
elast. Machinery mountings
connecting housing
non-return flap
saety valve or bypass controller incl. Bypass
flange compensator for intake / discharge side
flange compensator for bypass pipe
V-belt drive
belt guard if blower is equipped w/o acoustic hood

Accessories (Options)

Acoustic hood, incl. ventilation fan


indoor execution
or outdoor execution
or for higher noise dampening
special execution
Aerzener Maschinenfabrik GmbH

Driving motor
Motors acc. to IEC - std.
explosion proof

65

Instrumentation: (Ex i or ex-proof)


pressure gauge intake / discharge
pressure switch intake / discharge
temperature switch
Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo

Subjects
1. DELTA BLOWER
- Operating ranges of Positive Displacement Blowers and Srew Compressors
- Range of application of Aerzen Positive Displacement Blowers
- 3-lobe blowers with pre-inlet channel, working principle
- History of Aerzen blower units
- Package Delta Blower: advantages, scope of supply, modifications
2. Delta Blower Generation 5
- Noise study
- Construction of units, constructive modifications
- Advantages and customer benefit
- Possibilities to deliver
- Possible modifications
3. ATEX-solutions
Aerzener Maschinenfabrik GmbH

66

Bombas Bornemann S.R.L.

Fb 617-0/4-08/02

Seminario sobre Seleccin de Equipos y Mantenimiento


Preventivo
Geblse Verdichter Gaszhler
Machine groups, categories and zones acc. to 94/9/EG
Procedures with conformity evaluation for non-electrical machines

Group I

Group II

mining below ground,

risks caused by explosive atmosphere from gas/air- or dust/air mixtures, dust or steams

risks caused by mine gas and dust

Category M

Category 1
G
(gas)
(zone 0)

For machines applied in


underground mines as
well as in plants above
ground offering a high
degree of safety. The
operation must also be
ensured in case of rare
failures.

For machines in
underground mines as
well as in plants above
ground offering a high
degree of safety. In case
of explosive atmosphere
a shutdown is possible.

Category 2

D
(dust)
(zone 20)

G
(gas)
(zone 1)

For machines ensuring safety to a high


degree. Applied for the constant, longterm or frequent operation in hazardous
areas

(more than 1000 h/year, frequently).


Also in case of rare failures the
machines do not show any effective
source of ignition.

Annex II / Nr.: 2.0.1 resp. 2.0.2

Annex II / no.: 2.1

EU-type inspection
by indicated position acc. to annex III

EU-type inspection
by indicated position acc. to annex III

For the certification of these orders an


external position is necessary. For costs
and delivery time please contact our
technical department.

Category 3

D
(dust)
(zone 21)

G
(gas)
(zone 2)

D
(dust)
(zone 22)

For machines ensuring safety to a high


degree. Destined for cases where it has to
be reckoned with an explosive
atmosphere (10-1000 h/year rarely). Also
in case of rare failures the machines do not
show any effective source of ignition.

For machines ensuring a normal degree of


safety. Destined in case it has to be
reckoned - only rarely and if only for a
short time - with an explosive
atmosphere (0-10 h/year, very rarely).
Machines does not show any effective
ignition source at normal operation.

Annex II / no.: 2.2


Internal production control acc. to annex
VIII + storage of technical documents at
the manufacturer and deposit at an
indicated position for 10 years (min.) after
manufacturing of the last product or
individual inspection acc. to annex IX

Annex II / no.: 2.3

Internal production control acc. to annex


VIII

Certification can be carried out by AM.


For standard machines construction kits are available.
Special machines are certified separately via an individual analysis.

Necessary scope of documentation for non-electrical and electrical machines and operation means depending on zone and category
Machine group II
Category
Zone
1
2
3

0
1
2

EU-type inspection
electrical
non-electrical
x
x

Internal production control


electrical
non-electrical

x
x

x
x

*)

x
x
x

Conformity certification
electrical
non-electrical
x
x
x

*) complete documentation, incl. risk analysis are to be stored at an indicated position.

Aerzener Maschinenfabrik GmbH

67

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo


New ATEX-solutions from Aerzen
Certified base support:

Air inlet

Air deflection
Air outlet

The Aerzener base support - also discharge silencer - exclusively


functions by means of deflections! Absorption material will not
be used (combustible and not suitable for the food industry)!
Aerzener Maschinenfabrik GmbH

68

Bombas Bornemann S.R.L.

Seminario sobre Seleccin de Equipos y Mantenimiento Preventivo

Aerzen one step ahead!


Aerzener Maschinenfabrik GmbH

69

Bombas Bornemann S.R.L.

Anda mungkin juga menyukai