PO BOX 434
Friday Harbor, WA 98250
www.thesmallhousecatalog.com
support@thesmallhousecatalog.com
THE FARGESIA
CONSTRUCTION NOTES
DESIGN:
FLOOR AREA: 784 SQ FT
TOTAL AREA: 784 SQ FT
TOTAL ROOF AREA: 1,038 SQ FT
DESIGN STANDARDS:
INTERNATIONAL RESIDENTIAL CODE
WASHINGTON STATE ENERGY CODE
ARCH D 24" X 36" BLACK & WHITE PRINTING
DESIGN FACTORS:
FIRST FLOOR LOAD: 40 PSF LIVE / 10 PSF DEAD
SECOND FLOOR LOAD: 30 PSF LIVE / 10 PSF DEAD
ROOF LOAD: 20 PSF LIVE / 10 PSF DEAD (IRC TABLE R802.5.1(2)
8) MAILING ADDRESS:
THE SMALL HOUSE CATALOG
P.O. BOX 434
FRIDAY HARBOR, WA 98250
SHEETS
THE FARGESIA
EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM
WEBSITE: WWW.THESMALLHOUSECATALOG.COM
GENERAL NOTES
01
13'-11 3/8"
13'-11 3/8"
30'-0"
10'-0"
16'-0"
14'-0"
30'-0"
10'-0"
REAR ELEVATION
FRONT ELEVATION
scale: 1/4"=1'
B
02
scale: 1/4"=1'
A
02
13'-11 3/8"
13'-11 3/8"
10'-5 7/16"
10'-5 7/16"
28'-0"
28'-0"
THE FARGESIA
D
02
scale: 1/4"=1'
ELEVATIONS
scale: 1/4"=1'
02
WINDOW REQUIREMENTS:
1. MINIMUM 5.7 SQ. FT. NET CLEAR OPENABLE AREA, EXCEPT GRADE FLOOR
OPENINGS PERMIT MIN. 5 SQ. FT. OPENABLE AREA.
2. MINIMUM 24" NET CLEAR OPENABLE HEIGHT.
15'-9"
OPTIONAL NG OR LPG FIREPLACE
14'-3"
8'-11 13/16"
6'-9 3/16"
7'-0"
7'-3"
VENT BATHROOM VIA MIN. 55 CFM HRV SYSTEM
BIFOLD DOORS
4. SILL HEIGHT SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR.
5. OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM
WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE.
13'-6"
15'-0"
5'-9 1/16"
MASTER
BEDROOM
STAIRS:
B
04
20'-3 3/4"
19'-7 1/2"
6'-6 1/8"
CL
28'-0"
B
04
1'-8 1/4"
3'-0"
1'-8 1/4"
3'-4"
A
08
KITCHEN
3'-7 1/2"
CL
BEDROOM
150 CFM
C
08
3'-3 1/2"
4'-6 1/4"
FASTENER SCHEDULE:
3'-2"
BATH
BLOCKING:
5'-8 1/4"
8'-0"
8'-8 1/4"
7'-4"
4'-6"
ENTRY
4'-0"
9'-7 1/2"
2'-6"
28'-0"
13'-6"
HALL 3'-4"
4'-0"
WC
7'-0"
5'-0"
7'-8 1/4"
3'-4 1/2"
4'-2 1/4"
9'-8"
PRIVATE PATIO
5'-3"
24'-0"
2'-0"
4'-7 3/4"
4'-3 3/4"
3'-6"
8'-0"
6'-0"
10'-3 3/4"
16'-0"
14'-0"
A
04
9'-9 1/2"
3/4 BATH
3'-0"
BRACED WALLS:
6'-2 3/16"
GREAT ROOM
11'-11 1/4"
11'-3"
WATER EFFICIENCY:
1. WATER EFFICIENCY STANDARDS FOR PLUMBING FIXTURES SHALL BE MAX. 1.6
GAL PER FLUSH & 2.5 GAL PER MINUTE FOR SHOWER HEADS, LAVATORY
FAUCETS AND KITCHEN FAUCETS.
FLOOR PLAN
A
03
scale: 1/4"=1'
OR
ELECTRIC WATER HEATER WITH A MINIMUM EF OF 0.93.
AND FOR BOTH CASES
ALL SHOWER HEAD AND KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE
SHALL BE RATED AT 1.75 GPM OR LESS. ALL OTHER LAVATORY FAUCETS SHALL
BE RATED AT 1.0 GPM OR LESS.B TO QUALIFY TO CLAIM THIS CREDIT, THE
BUILDING PERMIT DRAWINGS SHALL SPECIFY THE OPTION BEING SELECTED AND
SHALL SPECIFY THE WATER HEATER EQUIPMENT TYPE AND THE MINIMUM
EQUIPMENT EFFICIENCY AND SHALL SPECIFY THE MAXIMUM FLOW RATES FOR
ALL SHOWER HEADS, KITCHEN SINK FAUCETS, AND OTHER LAVATORY FAUCETS.
THE FARGESIA
FLOOR PLAN
03
12
1
BUILDING NOTES:
ROOF SYSTEM:
STANDING SEAM METAL OR TILE ASSEMBLY
ROOFING UNDERLAYMENT
" CDX SHEATHING
I-JOIST RAFTER SYSTEM (CHECK MANUFACTURER FOR DEPTH & SPACING)
MIN. 1" AIR BAFFLE RECOMMENDED
MIN. R-60 INSULATION
" SHEETROCK OR T&G WOOD PANELING
2'-0"
SIDING: HORIZ. SIDING
" RAINSCREEN
1-" RIGID INSULATION (ROCKWOOL, E.G.)
HOUSEWRAP
1/2" CDX PLYWOOD SHEATHING
2X6 DF OR SPF #2 STUDS @ 24" O.C.
2-2X6 HEADERS
CAULKING AT ALL STUD AND PLATE JOINTS
MINIMUM R-23 CAVITY INSULATION
2X2 INTERIOR FURRING (WIRING & INSULATION CHASE)
CAULK & SEAL @ EXT. DOORS AND WINDOWS
6-MIL VAPOR BARRIER
INTERIOR SURFACE: 5/8" G.W.B.
INTERIOR LATEX PAINT
12'-0"
9'-0"
WALL SYSTEM:
SIDING: HORIZ. SIDING
" RAINSCREEN
1-" RIGID INSULATION (ROCKWOOL, E.G.)
HOUSEWRAP
1/2" CDX PLYWOOD SHEATHING
2X6 DF OR SPF #2 STUDS @ 24" O.C.
2-2X6 HEADERS
CAULKING AT ALL STUD AND PLATE JOINTS
MINIMUM R-23 CAVITY INSULATION
2X2 INTERIOR FURRING (WIRING & INSULATION CHASE)
CAULK & SEAL @ EXT. DOORS AND WINDOWS
6-MIL VAPOR BARRIER
INTERIOR SURFACE: 5/8" G.W.B.
INTERIOR LATEX PAINT
POLISHED CONCRETE
FLOATING WOOD FLOOR, OPT.
A
04
scale: 1/4"=1'
VENTILATION SYSTEM:
EXHAUST FAN @ KITCHEN (150 CFM)
EXHAUST FAN BATHS & LAUNDRY (MIN. 80 CFM OR CONNECTED TO HRV)
MIN. 55 CFM HRV SYSTEM
2'-0"
GATE, OPT.
9'-0"
CROSS SECTION
B
04
THE FARGESIA
scale: 1/4"=1'
04
30'-0"
16'-0"
4'-0"
10" x 5/8-IN STEEL ANCHOR BOLTS @ 4FT O.C. & 12-IN FROM ENDS
OF PLATE W/ 5/8-IN STEEL NUT & WASHER
28'-0"
24'-0"
FIRE-RETARDANT
CONNECTORS &
STEEL, SILICON
SEC R317.
28'-0"
30'-0"
A
05
DRAIN ROCK
THE FARGESIA
scale: 1"=1'
05
HOUSEWRAP
RAINSCREEN
SIDING
scale: none
PAINTED G.W.B.
scale: 1"=1'
THE FARGESIA
scale: none
06
34'-0"
14'-0"
20'-0"
8'-4"
16-IN ENGINEERED ROOF TRUSS @ 24" O.C. W/ MIN. R-60 INSUL.
9'-0"
32'-0"
28'-0"
32'-0"
34'-0"
A
07
scale: 1/4"=1'
I-RAFTER
I-RAFTER
I-RAFTER CONNECTION AT
TOP PLATE
I-RAFTER CONNECTION AT
BEARING PLATE
B
07
THE FARGESIA
C
07
scale: none
scale: none
07
3'-4"
6'-8"
2'-7 7/8"
4'-1/8"
1'-6"
1'-6"
3'-0"
3'-0"
1'-3/4"
9'-0"
5'-0"
1'-4 1/16"
3'-4"
2'-7 1/2"
2'-8 7/16"
9'-0"
1'-6"
1'-6"
3'-0"
3'-0"
3'-0"
3'-6"
3'-11 1/2"
15'-0"
3'-0"
3'-0"
13'-11 5/8"
KITCHEN VIEW
A
08
scale: 1/2"=1'
KITCHEN VIEW
B
08
scale: 1/2"=1'
OUTDOOR SHOWER
C
08
THE FARGESIA
scale: NONE
INTERIOR VIEWS
08
MASTER
BEDROOM
GREAT ROOM
GATE, SITE-BUILT
4
CL
3/4
BATH
KITCHEN
CL
BEDROOM
PRIVATE PATIO
WC
4
BATH
ENTRY
HALL
B
09
WINDOW SCHEDULE
SIZE
STYLE
NO.
1'-8" X 4'-0"
DOUBLE CASEMENT
1'-8" X 6'-0"
TRIPLE CASEMENT
1'-8" X 1'-8"
SINGLE CASEMENT
2'-0" X 6'-0"
2'-0" X 9'-0"
3'-4" X 6'-0"
DOUBLE CASEMENT
DOOR SCHEDULE
SIZE
STYLE
NO.
3'-0" X 7'-0"
ENTRY
6'-0" X 7'-0"
EXT. FRENCH
9'-0" X 7'-0"
EXT.
TRIPLE
BIFOLDING
TRIPLE
BIFOLDING
2'-6" X 6'-8"
INTERIOR POCKET
2'-6" X 6'-8"
HINGED CLOSET
2
F
scale: 1/4"=1'
FENESTRATION
A
09
THE FARGESIA
scale: 1/4"=1'
09
ELECTRICAL NOTES:
D
GFI
OUTLETS:
SWITCH
THREE-WAY SWITCH
D-240
240
GFIC/WP
$3
WATER HEATER:
1. A 4-6 GPM ELECTRIC ON-DEMAND W.H. IS TYP. SUFFICIENT
EVEN IN NORTHERN CLIMATES TO ADEQUATELY SUPPLY THE
BATHTUB.
W.R.
W.R.
CHANDELIER
MASTER
BEDROOM
SMOKE DETETCTOR
SD
CO
TELEPHONE OUTLET
GREAT ROOM
LAUNDRY ROOMS:
DATA/CAT-6
TELEPHONE/CAT-6
CL
BATHROOMS:
3/4
BATH
TV
GARBAGE DISPOSAL
GD
KITCHEN
CABLE TV OUTLET
ESP
J
DOOR BELL
CL
KITCHEN:
WC
BEDROOM
WH
PRIVATE PATIO
WATER HEATER
ENTRY
BATH
HALL
PORCHES:
1. MIN. ONE WP-GFI PER PORCH.
2. WP LIGHTS
SMOKE DETECTORS:
1. EACH FLOOR (INCLUDING BASEMENT) TO HAVE A SMOKE
DETECTOR.
2. ALL SLEEPING AREAS TO HAVE INDIVIDUAL SMOKE
DETECTORS.
3. PHOTOELECTRIC (NON-IONIZING) SMOKE DETECTORS ARE
RECOMMENDED.
4. CO2 DETECTORS REQ'D WHERE SOLID FUEL HEATING IS TO
BE USED.
5. SMOKE AND CO2 DETECTORS TO BE WIRED ON SEPARATE
CIRCUITS.
THE FARGESIA
A
E
10
1
GREAT ROOM
9. MAIN STACK VENT: TYP. EQUAL OR > THAN MAIN DWV LINE.
KITCHEN
CL
BEDROOM
PRIVATE PATIO
WC
ENTRY
4. TOILET: 3/8"
5. BATHTUB/SHOWER: 1/2"
3/4
BATH
BATH
HALL
THE FARGESIA
A
P
11