Anda di halaman 1dari 13

MOSCHATA ROLLING BUNGALOW

:: plans for a one and one-half story, 160 sq. ft. Tiny House ::

SLEEPING LOFT

DINING, OFFICE & KITCHEN

LIVING & ENTRY


THE small HOUSE CATALOG
PO BOX 434
FRIDAY HARBOR, WA
98250

W W W . T H E S M A L L H O U S E C A T A L O G . C O M

DESIGNED & DRAFTED BY THE small HOUSE CATALOG 2010


RELEASED: 9/2011
REVISED: 7/2013; 8/2014; 1/2015

ANCHORS: H1 HURRICANE TIES, RAFTER RIDGE CONNECTORS,


METAL STRAPPING, HDU2'S AND A23/A35 RIGHT ANGLE CLIPS
ARE RECOMMENDED FOR THIS TINY HOUSE.

STOCK PLAN DISCLAIMER:


1)THE small HOUSE CATALOGhas prepared these
documents to meet generally accepted professional
standards and practices. However, they have been
designed without any knowledge of or reference to
the Licensees specific site or geographical
location.Specific site conditions may vary and
include but are not limited to such things as: such as
frost depth, soil bearing capacity, seismic and wind
zones, etc.In addition, local code requirements,
including such life-safety requirements as stair
width, stair rise and run, egress windows and smoke
detectors, etc. may vary.The strength of materials
(e.g.
lumber)
available
may
vary.Therefore,supplemental to these documents, it
is the Licensees responsibility to consult with his/
her chosen builder, local building department anda
structural engineer to determine that these
documents meet all current federal, state/provincial
and local codes, ordinances/bylaws and regulations,
etc., and are appropriate to specific site conditions.
Compliance with such requirements shall take
precedence over these documents.
2) Any use of this information without adaptation to
changes in codes, standards, site conditions and
other factors is at the Licensees sole risk.THE
small HOUSE CATALOGassumes no responsibility for
changes made to these plans by others and makes no
warranties, either expressed or implied, in the use of
these plans. The Licensee agrees to defend and
indemnifyTHE small HOUSE CATALOGfor all claims,
costs, losses or damages resulting from the use of
these documents.
3) Before starting construction, it is the builders
responsibility to check all dimensions and details,
and verify conformance with governing code
requirements for the geographic area in which the
house is to be built. All structural, mechanical and
electrical requirements shall also be reviewed
before construction begins. Codes govern over
drawings and dimensions govern over scale. Please
notifyTHE small HOUSE CATALOGof dimensional
discrepancies.
4)THE small HOUSE CATALOGhas not been engaged
for construction supervision of any kind and assumes
no responsibility to ensure that construction
conforms to these plans, nor has any responsibility
for construction means, methods, techniques,
sequences, procedures or safety precautions in
connection with the work.
5) This is not a sale of original documents.THE small
HOUSE CATALOGretains ownership of all original
documents and all subsequent copies (regardless of
format).
6) The Licensee is granted the right to make copies as
needed for the construction of one (1) building per
plan purchase and/or free download.THE small
HOUSE CATALOGrequests that you honor this
copyright policy. Additional rights can be easily
purchased at a reasonable price fromTHE small
HOUSE CATALOGoffice.
7) Terms and conditions apply to all plans.

FLOOR JOISTS: JOISTS ARE INSTALLED, LOCATED & SPACED


ACCORDING TO THE DESIGN. ANY JOISTS HAVING A SLIGHT BOW
EDGEWISE SHOULD BE PLACED WITH THE CROWN ON TOP.
JOISTS ARE CANTILEVERED TO SUPPORT A LIGHT FRAMED WALL
& ROOF. INSTALL BLOCKING BETWEEN JOISTS TO TRANSFER
CONCENTRATED LOADS TO TRAILER BELOW & TO PREVENT
JOISTS ROLLING.
PRODUCT QUALITY:
1. CONSIDER SPECIAL ORDERING FORMALDEHYDE-FREE PLYWOOD.
2. USE ZERO-VOC, NON-TOXIC & NON-CARCINOGENIC PAINTS &
STAINS.
3. USE ZERO-VOC, NON-TOXIC & NON-CARCINOGENIC CAULKS,
SEALANTS & ADHESIVES.
4. AVOID POLYSTYRENE RIGID BOARD INSUL., WHICH CONTAINS
BROMINATED FIRE RETARDANTS.
BUGS & PESTS:
NO BROAD SPECTRUM INSECTICIDES OR HERBICIDES TO BE
APPLIED BEFORE, DURING OR AFTER THE FOUNDATION WORK.
APPLY TERMITE SHIELDS, IF REQ'D. PROPERLY SCREEN ALL
VENTS & OPENINGS. BORATES (STANDARD BORAX) CAN BE
APPLIED INSIDE WALL CAVITIES IN CLIMATES WHERE INSECTS
MAY BE PROBLEMATIC.
ROOF FRAMING NOTES:
1. NUMBER OF JACK STUDS FOR ALL GIRDER & HEADER SPANS
PER IRC TABLE R502.5 (1) & (2) - FOOTNOTE 'D'.
2. POSITIVE CONNECTION & TRANSFER OF LOAD FROM ROOF TO
LOAD SUPPORTING ELEMENTS REQ'D.
3. PROVIDE ANCHORAGE OF BEAMS OR GIRDERS TO POSTS PER
IRC SEC'S R407.3, R502.9 & R802.11
4. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER SCHEDULE,
IRC TABLES R602.3 (1) THRU (5).
5. SOLID BLOCKING REQ'D @ ALL BEARING POINTS OF FLOOR,
CEILING & ROOF SYSTEMS AS PER IRC SEC'S R502 & R802.
6. PROVIDE VENTILATION PER IRC SEC R806.
ELECTRICAL:
1. KITCHEN & BATHROOM, BASEMENT OUTLETS TO BE GFCI.
2. EXTERIOR OUTLETS TO BE WEATHER PROOF.
3. AFCI RECOMMENDED IN SLEEPING LOFTS.
PLUMBING:
1. KITCHEN SINKS: DWV MIN. 2" DRAIN & 1 1/2" VENT.
2.BATHROOM SINKS: DWV MIN. 1 1/4 DRAIN & VENT.
3. BATHTUBS: MIN. 2" DRAIN & 1 1/2" VENT.
4. SHOWERS: MIN. 1 1/2" DRAIN & VENT.
5. INCOMING WATER SUPPLY LINE: TYP. 3/4" - 1"
6. PRIMARY WATER SUPPLY LINE: TYP. 3/4"
7. INTERIOR WATER SUPPLY LINES: TYP. 1/2"
8. MAIN DRAIN LINE: TYP. 3"
9. MAIN STACK VENT: TYP. EQUAL OR > THAN MAIN DWV LINE.

WEATHER PROOF OUTLET

OR

RANGE OUTLET

O 240 240 OUTLET

FIRST FLOOR AREA: 160 SQ. FT.


SLEEPING LOFT AREA: 60 SQ. FT.
STORAGE LOFT AREA: 18 SQ. FT.
TOTAL FLOOR & LOFT AREA: 238 SQ. FT.
FIRST FLOOR LOAD: 40 PSF LIVE / 20 PSF DEAD [SEE IRC TABLE R502.3.1 (2)]
LOFT FLOOR LOAD: 20 PSF LIVE / 10 PSF DEAD [SEE IRC TABLE R802.4 (2)]
ROOF LOAD: 20 PSF LIVE / 20 PSF DEAD [SEE IRC TABLE R802.5.1 (2)]

THIS SECTION FOR YOUR NOTES & IDEAS

SINGLE POLE WALL MOUNTED LIGHT SWITCH

$3

3-WAY WALL MOUNTED LIGHT SWITCH


CEILING LIGHT
WALL LIGHT

CEILING LIGHT (WEATHER PROOF)

WALL LIGHT (WEATHER PROOF)

PULL SWITCH CEILING LIGHT

CEILING EXHAUST FAN

DIRECT VENT WALL VENT

SD

SMOKE DETECTOR

CO

CARBON MONOXIDE DETECTOR

WH

ON-DEMAND WATER HEATER

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

5) Terms and conditions apply to all plans.

OWP

O O O O O
I
I

4) House plans are non-refundable.

OGFI GFI ELECTRICAL OUTLET

11111111

FRAMING: PRIOR TO START-UP, INSPECT TRAILER CONDITION AND


COMPARE ALL DIMENSIONS WITH PLAN DIMENSIONS. IT IS
POSSIBLE THAT YOUR SELECTED TRAILER WILL VARY SLIGHTLY
WITH THE DIMENSIONS SHOWN, PARTICULARLY IN RESPECT TO
WHEEL WELL SIZE AND OVERALL LENGTH & WIDTH.

SWITCHED ELECTRICAL OUTLET

11111111

3) The Licensee is granted license to build one house


per plan. Additional prints may be independently
copied, as required, to build your house. Any changes
to these plans must be confirmed by a licensed
structural engineer and approved by your local code
enforcement agency.

OS

11

SITE PREPARATION: A SURFACE DRAINAGE PATTERN SHOULD BE


ESTABLISHED WHICH WILL DRAIN THE ENTIRE AREA AND DIRECT
WATER AWAY FROM THE TRAILER DURING & AFTER
CONSTRUCTION.

STANDARD ELECTRICAL OUTLET (DUPLEX)

11

2) THE small HOUSE CATALOG including anyone who


has been involved in the creation, production, or
delivery of these documents shall not be liable for
any direct, indirect, consequential, or incidental
damages.

DESIGN FACTORS

11

FASTENERS: FOR ALL PRESERVATIVE-TREATED & FIRERETARDANT TREATED: CONNECTORS SHALL BE TREATMENT
RATED. FASTENERS SHALL BE HOT- DIPPED ZINC-COATED
GALVANIZED, STAINLESS STEEL, SILICON BRONZE OR COPPER.
FOLLOW IRC TABLE R602.3(1) FASTENER SCHEDULE FOR
STRUCTURAL MEMBERS.

THIS HOUSE DESIGN IS BASED IN PART ON THE 2012 INTERNATIONAL RESIDENTIAL CODE (IRC) & THE 2009 WASHINGTON STATE
ENERGY CODE. ASPECTS OF THIS HOUSE DO NOT MEET STANDARD BUILDING CODES AND ARE TYP. EXEMPT FROM SUCH CODES
AS LONG AS IT IS BUILT ON A TRAILER AND NOT ON THE GROUND. THIS INFORMATION SHOULD BE VERIFIED BY YOUR LOCAL
CODE ENFORCEMENT AND BUILT ACCORDING TO LOCAL ZONING LAWS. THESE CODES WILL SUPERSEDE ANY INFORMATION
CONTAINED WITHIN THESE DOCUMENTS.

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

TRAILER:

ELECTRICAL LEGEND

11

1) These plans have been designed to satisfy


generally accepted building requirements.
However,THE small HOUSE CATALOGcannot
guarantee that they will be appropriate for your
specific conditions or that they will meet all the
requirements of your local coding agency. It is the
responsibility of the Licensee to
see that they
do. Consultation with your builder prior to
submission of a permit application is recommended.

DESIGN STANDARDS

GENERAL NOTES

GENERAL CONSTRUCTION NOTES:

LICENSE AGREEMENT:

8)THE small HOUSE CATALOGcan be contacted at


P.O. BOX 1734, Pt. Roberts, WA 98281-1734. Tel. (360)
207-4513. Email: support@thesmallhousecatalog.com.
Website: www.thesmallhousecatalog.com

00

CONT. RIDGE VENT

PRE-CUT STANDING SEAM METAL ROOF

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

BARGE RAFTER ONE SIZE WIDER


THAN RAFTERS (E.G. 2X6
RAFTERS = 1X8 0R 2X8 BARGE)

3" O/HANG
13'-11" +/-

4-1/2" LAP SIDING W/3" EXPOSURE


(STANDARD 6" LAP SIDING IS NOT AN
APPROPRIATE SCALE FOR A TINY
HOUSE); PAINT W/ DESIRED COLOR(S)!
COLOR SHOWN ON COVER IS "ORANGE
YOU GLAD" BY MYTHIC PAINTS & CAN
BE ORDERED ONLINE (FREE SHIPPING).

TRAILER HEIGHT

20'-0" +/-

FRONT ELEVATION
NO SCALE - ISOMETRIC

LEFT ELEVATION

NO SCALE - ISOMETRIC

DICKINSON PROPANE STOVE VENT STACK W/


FACTORY SUPPLIED BELL

OPT. 1X APRON BELOW SILL

2X WINDOW HEAD CASING W/


1/2" O/HANGS

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

1'-8" +/-

1X FASCIA

5/4" WINDOW RAILS


2X WINDOW SILL

08

METAL FLASHING OR SITEBUILT WATER TABLE & CAP


ARE REQ'D 0/ WHEEL COVERS

8'-0" +/-

1X CORNER TRIM

ELEVATIONS

4X4 PORCH POST

RIGHT ELEVATION

NO SCALE - ISOMETRIC

REAR ELEVATION

NO SCALE - ISOMETRIC

01

NOTES INDICATED WITH AN (*) ARE INCLUDED TO SHOW


PRECISELY WHERE TINY HOUSES DEVIATE FROM THE
MOST WIDELY ACCEPTED CODES. WHILE THESE CODES DO
NOT STRICTLY APPLY TO TINY HOUSES BUILT ON
TRAILERS AT THE TIME OF THIS PLAN'S DESIGN, IT'S GOOD
PRACTICE TO CONSIDER WHY SOME OF THESE CODES
HAVE BEEN ENFORCED & HOW THEY MIGHT EFFECT
SOMEONE LIVING IN A TINY SPACE. WHERE POSSIBLE,
THESE CODES HAVE BEEN INCORPORATED INTO THIS
PLAN.

2'-6"

17'-6"
6'-0"

8'-7/8"

2'-8"

PORCH
1

ENTRY

2'-7"

OFFICE
NOOK

BATH
5'-11"

10'-6 1/2"

4'-11 1/2"

DINING AREA

1'-7 3/4"
2'-6"

7'-4"

8'-0"
8'-3/4"

KITCHEN

LIVING AREA

4'-8"

5'-4" 2'-1/2"

WINDOW REQUIREMENTS*:
1. MINIMUM 5.7 SQ. FT. NET CLEAR OPENABLE AREA,
EXCEPT GRADE FLOOR OPENINGS PERMIT MIN. 5 SQ. FT.
OPENABLE AREA.
2. MINIMUM 24" NET CLEAR OPENABLE HEIGHT.
3. MINIMUM 20" NET CLEAR OPENABLE WIDTH.
4. SILL HEIGHT SHALL NOT BE MORE THAN 44" ABOVE
THE FLOOR.
5. OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE
OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR
SPECIAL KNOWLEDGE.

4'-4 1/2"
PROPANE
FIREPLACE

3'-1/2"

1'-7 3/4"

7'-3/4"

8'-3/4"

3'-5 1/4"

20'-0"
1
07

SPACE FOR REMOVABLE INDUCTION COOK-TOP


OR COUNTER SUNK BOAT/RV PROPANE STOVE

60" FULL FRIDGE

TOASTER OVEN TOWERW/ STORAGE

PLAN
1 FLOOR
1/2" = 1'

20'-0"

STAIRS*:
1. STAIRWAYS & STAIRWAY LANDINGS, HANDRAILS &
ILLUMINATION SHALL COMPLY WITH IRC SEC R311. GUARDS
PER IRC SEC R312.

2'-9 1/2"

4'-0"

SMOKE DETECTORS & CARBON MONOXIDE ALARMS*:

8'-0"

WATER EFFICIENCY*:
1. WATER EFFICIENCY STANDARDS FOR PLUMBING
FIXTURES SHALL BE MAX. 1.6 GAL PER FLUSH & 2.5
GAL. PER MINUTE FOR SHOWER HEADS, L A V A T O R Y
FAUCETS AND KITCHEN FAUCETS.
BRACED WALLS*:
FOLLOW IRC R602.10.3 & LOCAL CODE REQ'S. THIS TINY
HOUSE HAS BEEN DESIGNED TO MEET AN SW4 SHEAR
WALL RATING USING HDU2 HOLD DOWNS & IRC SHEAR
ADD RAILING & ACCESS FOR
WALL NAILING SCHEDULE.
ADDITIONAL SINGLE SLEEPING LOFT

8'-8"

2'-5 1/2"

STORAGE OR
SINGLE BED
SLEEPING LOFT

MINUMUM FIREPLACE REQUIREMENTS*:


1. PROPANE & SOLID FUEL BURNING FIREPLACES
INSTALLATION SHALL COMPLY WITH IRC CHAP. 10
2. PROPANE & SOLID FUEL BURNING FIREPLACES TO BE
INSTALLED ACCORDING TO MANUFACTURER'S
INSTRUCTIONS.

8'-6 1/2"

4'-0"

8'-4"
TEA TABLE
(PLAN INCLUDED)
VERTICAL LADDER 2'-1"
(PLAN INCLUDED)

7'-4"

8'-0"

1'-11"

SLEEPING LOFT

4'-0"

4'-0"

2'-9 1/2"

8'-6 1/2"

FLOOR PLANS

1'-5 1/4"

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

MINIMUM ROOM AREAS & CEILING HEIGHT*:


1. HABITABLE ROOMS PER IRC SEC R304 FOR FLOOR
AREA.
2. HABITABLE ROOMS PER IRC SEC R305 FOR CEILING
HEIGHT. SECOND FLOOR HALLWAYS, BEDROOMS &
BATHROOMS TO MEET R305 - EXCEPTIONS (1) AND (2)
FOR SLOPED CEILINGS.

1. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH IRC


R314.3.
2. PROVIDE UL-2034 APPROVED CARBON MONOXIDE
ALARMS OUTSIDE EACH SEPARATE SLEEPING AREA IN THE
IMMEDIATE VICINITY OF EACH BEDROOM IN ACCORDANCE
WITH IRC R315.2 O

3'-5 1/8"

EGRESS*:
1. ALL ROOMS TO BE USED FOR SLEEPING PURPOSES &
BASEMENTS WITH HABITABLE SPACE REQUIRE
EMERGENCY & RESCUE OPENING COMPLYING WITH IRC
SEC R310.1.
2. AT LEAST ONE DOOR SHALL MEET EGRESS REQ. IRC
R311. THIS DOOR MUST BE SIDE HINGED WITH MIN. 32" (813
MM) CLEAR WIDTH WHEN MEASURED B/T THE FACE OF
THE DOOR & THE STOP W/ DOOR AT 90 DEGREES (1.57
RAD.). MIN. CLEAR HEIGHT OF DOOR MUST NOT BE < THAN
78" (1981 MM) MEASURED FROM TOP OF THRESHOLD TO
BOTTOM OF STOP.

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

FLOOR PLAN NOTES:

8'-8"
20'-0"

PLAN
2 LOFT
1/2" = 1'

02

TRAILER NOTES:
REMOVE DECKING BENEATH PORCH

2 HOLES @ EACH SIDE FOR


STRONG-TIE DDT1Z HOLD
DOWNS (SEE DETAILS PAGE)

6'-0" +/-

2. IF YOU PURCHASE A USED TRAILER YOU WILL NEED TO


REMOVE THE HORIZONTAL METAL COMPONENTS ABOVE THE
TRAILER BED (EXCEPT THE WHEEL COVERS).

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

6'-11" +/-

4. WHETHER YOU BUY NEW OR USED THE TYPE OF TRAILER


YOU SELECT SHOULD HAVE A GROSS VEHICLE WEIGHT RATING
(GVWR) OF 10K LBS. (MIN. 5K LBS. PER AXLE) AND YOU
SHOULD VERIFY ALL SYSTEMS ARE IN WORKING ORDER.
5. PURCHASING A TRAILER WITH A BED THAT SITS 20" OR
LESS FROM THE TOP OF THE BED TO THE GROUND WHEN THE
TRAILER IS LEVEL WILL ENSURE YOUR ROLLING BUNGALOW
WILL HAVE THE PROPER ROAD HEIGHT ONCE COMPLETED.
6. IF YOU HAVE A TRAILER MADE TO ORDER (RECOMMENDED)
IT IS GOOD PRACTICE TO SHOW YOUR PLANS TO THE
MANUFACTURER. THE MANUFACTURER MAY BE ABLE TO
EXTEND THE DECKING SUBSTRUCTURE ALONG THE LONG SIDES
OF YOUR TRAILER TO OFFER ADDITIONAL SUPPORT FOR THE
FLOOR SYSTEM OF YOUR HOUSE.

2 HOLES @ EACH SIDE FOR


STRONG-TIE DDT1Z HOLD
DOWNS (SEE DETAILS PAGE)

7. SOME TRAILER MANUFACTURERS INCLUDE:

20'-0" +/-

REMOVE DECKING TO PROVIDE DRAINAGE;


USE P.T. OR CEDAR 2X4'S;
INSTALL METAL FLASHING O/ LEDGER BOARDS;
CEDAR 4X4 POST

TUFF TRAILER (WWW.TUFFTRAILER.COM)


BIG TEX TRAILERS (WWW.BIGTEXTRAILERS.COM)
KAUFMAN TRAILERS (WWW.KAUFMANTRAILERS.COM)
TRAILERS PLUS (WWW.TRAILERS PLUS.COM)

STRONG-TIE DDT1Z
HOLD DOWN

HOLD DOWNS ARE USED TO BRACE


WALLS FOR EARTHQUAKES & HIGH WIND
IN RESIDENTIAL CONSTRUCTION. IN TINY
HOUSES THEY SERVE TO BRACE WALLS
FROM RACKING, ESPECIALLY IMPORTANT
IN WALLS WITH SUBSTANTIAL OPENINGS
AND LITTLE PLYWOOD. THEY ALSO TIE A
TINY HOUSE TO ITS TRAILER BY LOCKING
ITS STUDS, PLATES & JOISTS TO THE
TRAILER FRAMING..

ESTIMATED TRAILER DIMENSIONS


1/2" = 1'

20'-0"
MAIN FLOOR FRAMING NOTES

1'-6 3/4"

1'-7 1/4"

2'-0"

2'-0"

8'-6 1/2"
1'-6 1/4"

5 3/4"

2'-4 1/2"

2. 3/4" CDX PLYWOOD OR DIAG. BOARDS SUBFLOOR (INSTALL


FLOOR INSULATION FIRST... )

5'-11"
4 3/4"

5'-6 1/2"

1. 2X6 DF#2 FLOOR JOIST SYSTEM W/ JOISTS @ 24" O.C.

2'-0"

2'-0"

2'-0"

2'-3/4"

3. 2X4 P.T. OR CDR PORCH JOISTS.


4. BLOCKING RECOMMENDED B/T JOISTS
5. PORCH JOISTS SHOULD BE PRESSURE TREATED 2X DF #2
OR NATURALLY DECAY RESISTANT (CEDAR, E.G.) MATERIAL.
6. HOUSE TO BE ANCHORED TO TRAILER SUBSTRUCTURE WITH
5/8" ANCHOR BOLTS (OR STRONG-TIE HDU2 CONNECTORS) AT
SHORT NON-CANTILEVERED ENDS OF HOUSE & TO TRAILER
DECKING USING A23 OR A35 FRAMING ANCHORS WITH SSD
SCREWS. IF THE LATTER METHOD IS USED, METAL STRAPPING
SHOULD ALSO BE INSTALLED TO TIE THE HOUSE STRUCTURE
DIRECTLY TO THE TRAILER SUBSTRUCTURE.
6. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER
SCHEDULE, TABLES R602.3 (1) THRU (5).

2'-8"

8'-0"

8'-0"

5'-4"

1'-11 1/4"

1'-6 3/4"

1'-7 1/4"

2'-0"

5'-6 1/2"

2'-0"

1'-6 1/4"

5 3/4"

9. FOR ALL PRESSURE PRESERVATIVE & FIRE-RETARDANT


TREATED WOOD USE TREATMENT RATED CONNECTORS & HOTDIPPED GALVANIZED, STAINLESS STEEL, SILICON BRONZE OR
COPPER FASTENERS PER IRC SEC R317.

4 3/4"

8. LUMBER SHALL BE PROTECTED AGAINST ROT & DECAY


PER IRC SEC R317. (TYP, P.T. OR CEDAR)

5 1/4"

7. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF FLOOR,


CEILING & ROOF SYSTEMS PER IRC SEC'S R502 & R802 & IBC
SEC'S 2308.8.2 & 2308.10.6.

2'-0"

5'-11"

2'-0"

2'-0"

8'-6 1/2"

2'-3/4"

STRONG-TIE ANGLE CLIPS

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

3. IF YOU BUY A NEW TRAILER YOU CAN CUSTOM ORDER IT TO


MEET YOUR NEEDS (SEE NO. 2 ABOVE) AND MAY ACTUALLY
COST LESS THAN A USED ONE BECAUSE CERTAIN FEATURES
(LIKE RAMPS) CAN BE OMITTED. A NEW TRAILER SHOULD
ALSO INCLUDE FUNCTIONING BRAKE LIGHTS, BRAKING
SYSTEMS, ETC., WHICH ARE THINGS THAT NED TO BE TESTED
ON A USED TRAILER PRIOR TO PURCHASING.

9" +/-

TRAILER & MAIN FLOOR FRAMING PLANS

1. A TYPICAL 7' X 20' CAR HAULER OR FLATBED TRAILER IS A


GOOD CHOICE FOR A ROLLING BUNGALOW.

20'-0"

110 REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS


FOR FASTENERS & CONNECTORS.

CANTILEVERED FLOOR FRAMING O/ TRAILER


1/2" = 1'

VISUAL NOTE: CONNECT EACH JOIST TO TRAILER DECKING W/MIN.


4 A23 OR A35 STRONG-TIE CLIPS BOTH SIDES @ 24" O.C. & USE
METAL STRAPPING TO TIE RIM JOISTS TO TRAILER FRAMING. SEE
SIDE NOTES FOR ALTERNATE METHOD.

NOTE: IN DIMENSIONING OUT FRAMING PLANS, OVERALL PATTERN SPACING IS SOMETIMES LOST. REST ASSURED THAT THESE DIMENSIONS ARE ESTABLISHED AT SET PATTERNS, EITHER 16" OR 24" O.C., TO PROPERLY MANAGE STANDARD 4X8 SHEET GOODS.

03

WALL FRAMING NOTES:


1'-11 1/4"

HOUSE HEIGHT:

3 1/2" SEAT FOR 2X4 WALL TIE

3 1/2" SEAT FOR 2X4 WALL TIE


1'-1 1/4"

1'-11 1/4"

20'-0"

1'-5"
1'-7 5/8"

3'-7 3/4"

3 1/2" RAFTER SEAT


1'-10 1/2"

1'-10 1/2"

1'-10 1/2"
3'-1/4"

4'-1/4"
1'-10 1/2"

2'-1 1/2"

1'-10 1/2"

4'-1/4"

4'-1/4"

7'-5 3/4"

11'-1 1/2"

4'-1/4"
7'-5 3/4"

SHEAR WALLS:
6'-6"

1. TINY HOUSES SHOULD BE BUILT TO


PROPERLY MANAGE LATERAL
LOADS. IN ORDER TO DO THIS EACH
EXT. HOUSE WALL MUST HAVE ONE
SECTION W/ A MIN. 4X8 SHEET OF
UNBROKEN PLYWOOD, PROPERLY
NAILED TO SCHEDULE SW4 OR
SIMILAR. CORNER BRACING IS
HELPFUL BUT NOT A REPLACEMENT
FOR SHEAR WALL NAILING
SCHEDULES.

1'-6"

6"

2'-4 1/2"

1'-6 1/4"

11 1/2"

1'-1"
8'-6 1/2"

4'-9"

IMPORTANT NOTE: BE SURE TO VERIFY ROUGH OPENINGS FOR


WINDOWS & DOORS WITH THE WINDOW MANUFACTURER PRIOR TO
STARTING YOUR FRAMING. THSE DIMENSION MAY CHANGE OR YOU MAY
USE WINDOWS W/ DIFFERENT R.O. DIMENSIONS. IT IS GOOD PRACTICE
TO LAYOUT YOUR WALLS ACCORDING TO THE PLAN & VERIFY THE
PLAN DIMENSIONS W/ YOUR ON-SITE DIMENSIONS, WHICH MAY BE
SLIGHTLY DIFFERENT. SIMPLY ADJUST YOUR LAYOUT ACCORDINGLY.

FRONT END WALL FRAMING PLAN


1/2" = 1'

3. PLYWOOD SHOULD INSTALLED AS


PRESCRIBED ABOVE W/NON-TOXIC
SHEAR WALL RATED ADHESIVE
WHEREVER IT MEETS HOUSE
FRAMING (STUDS, PLATES, ETC).

RIGHT SIDE WALL FRAMING PLAN


1/2" = 1'

1'-11 1/4"

GAP = LOFT JOIST

8'-0"

C
L
1'-1 1/4"

11 1/2"

16'-11"

1'-10 1/2"

1'-10 1/2"

1'-10 1/2"

3'-1/4"

2'-2 3/4"

1'-6"

2'-6 3/4"

4'-1/4"

4'-1/4"

7'-5 3/4"

6'-3 1/2"

1'-11 1/4"

1'-5"
1'-7 5/8"

1'-10 1/2"

11'-1 1/2"

3'-1/4"

7'-5 3/4"

WALL ORIENTATION

1'-11 1/4"

1'-0"

1'-0"

1'-6 3/4"

2'-0"

1'-4 3/4"

8'-6 1/2"

6"

1'-6"

6"

1'-6"

5'-11"

1'-5 3/4"

1'-6 3/4"

3'-1/2"

2'-0"

1'-6 3/4"

2'-1 1/2"

1'-11 1/2"

1'-9 1/4"

6"

KITCHEN

6 1/4"

5 1/2"

BATH

7 1/4"

OFFICE
NOOK

2-2X6 HEADER W/ 1/2 PLY B/T

5 1/4"

1'-8 1/4"

1'-1 1/4"

2'-2 1/2"

THIS WALL BORDERS PORCH

TBD

6'-10 1/4"

BATH/KITCHEN WALL
BATH/OFFICE NOOK WALL

11 1/2"

3 1/2" SEAT FOR 2X4 WALL TIE

20'-0"

3'-7 3/4"

2'-11 1/2"

2'-3/4"

20'-0"

7'-5"

2'-0"

WALL FRAMING PLANS

2'-3"

1'-6 1/4"

5'-11"

5'-6 1/2"
2'-4 1/2"

1'-5 1/2"

5 3/4"

1'-7 1/4"

5 3/4"

1'-6 1/4"

6 1/2"

2'-0"

4 3/4"

5"

2-2X6 HEADER W/ 1/2 PLY B/T

2. RECOMMEND SHEAR WALL: 1/2"


CDX W/ 8D NAILS SPACED 3" O.C. @
EDGES, 12" O.C. IN THE FIELD. 2-HUD2'S
@ EACH 8' SIDE OF TINY HOUSE
CONNECTED TO TRAILER FRAMING.
HOLES CAN BE DRILLED IN YOUR
TRAILER'S SUBSTRUCTURE ON-SITE
OR BY THE FABRICATOR WHEN
PLACING AN ORDER.

1'-3 1/4"

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

19'-5"

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

IF YOU INTEND TO MOVE YOUR


PORTABLE HOUSE YOU'LL NEED TO
DETERMINE THE TRAILER HEIGHT
LIMITS FOR YOUR PARTICULAR
STATE OR PROVINCE. AREAS VARY
FROM 13'-6" (PRIMARILY IN THE EAST)
TO 14'-0" (MOSTLY IN THE WEST).
THESE PLANs ARE DESIGNED TO
BUILD A 13'-11" +/- TALL HOUSE
(INCLUDING A 20" HIGH TRAILER). IF
YOU NEED TO ADJUST FOR 13'-6"
LIMITS SIMPLY SUBTRACT THE
NECESSARY 6-INCHES (ASSUMING YOU
HAVE A 20" HIGH TRAILER) FROM THE
FRAMING HEIGHT OF ALL WALLS.
THIS IS A VERY SIMPLE SOLUTION &
THE PLANS ARE DESIGNED TO WORK
THIS WAY.

1'-1 1/4"

8'-0"
C
L
11 1/2" 11 1/2"

7'-5"

17'-6"

INTERIOR WALL FRAMING


1/4" = 1'

LEFT SIDE WALL FRAMING PLAN


1/2" = 1'

2'-6"

REAR END WALL FRAMING PLAN


1/2" = 1'

NOTE: IN DIMENSIONING OUT FRAMING PLANS, OVERALL PATTERN SPACING IS SOMETIMES LOST. REST ASSURED THAT THESE DIMENSIONS ARE ESTABLISHED AT SET PATTERNS, EITHER 16" OR 24" O.C., TO PROPERLY MANAGE STANDARD 4X8 SHEET GOODS.

04

FRAMING NOTES
FLOOR JOISTS:
JOISTS ARE INSTALLED, LOCATED & SPACED
ACCORDING TO THE DESIGN, WHICH IS 24" O.C.
ANY JOISTS HAVING A SLIGHT BOW EDGEWISE
SHOULD BE PLACED WITH THE CROWN ON TOP.
MAIN FLOOR JOISTS ARE DESIGNED TO CREATE
A CANTILEVERED FLOOR SYSTEM. ALL JOISTS
TO BE FASTENED TO TRAILER WITH FULLY
SCREWED STRONG-TIE CLIPS. WHERE
APPLICABLE, INSTALL BLOCKING BETWEEN
JOISTS TO TRANSFER CONCENTRATED LOADS
TO BEARING BELOW & PREVENT JOISTS FROM
ROLLING.

LOFT FLOOR JOIST ARE TIED TO CORRESPONDING STUDS


W/ STRONG-DRIVE SDS STRUCTURAL-CONNECTOR
SCREWS SIZED 1/4" X 3" (340 LBS. SHEAR CAPACITY) TO
FASTEN LOFT FLOOR JOISTS TO CORRESPONDING STUDS.
2'-10"

2X4 DF#2/SPF#2 LOFT FLOOR JOISTS @ 24" O.C.


8'-0"

2'-9 1/2"

1'-5 1/4"

6 3/4"

5'-2"

8'-6 1/2"

2'-0"

2'-0"

2'-2 1/4"

8'-8"

20'-0"

LOFT FLOOR FRAMING PLAN


1/2" = 1'

2X VENTED & SCREENED BLOCKING


2x4 LOOKOUTS, EVENLY SPACED;
W/ 3/4" T&G DECKING ATTACHED BELOW

2x6 DF#2/SPF#2 RIDGE BEAM

8'-3"

2X6 DF#2/SPF#2 RAFTERS @ 24" O.C.


W/ H1 HURRICANE TIES & MIN. R-19
INSUL.; LEAVE 1" VENTILATION GAP
(BAFFLE) B/T INSUL. & ROOF DECKING

1X LEDGER BOARD
LET-IN TO STUDS

1'-11 1/4"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

2'-0"

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

8'-8"

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

8'-6 1/2"

LOFT & ROOF FRAMING PLANS

2'-9 1/2"

5 3/4"

ROOF FRAMING NOTES:


1. NUMBER OF JACK STUDS FOR ALL GIRDER &
HEADER SPANS PER IRC TABLE R502.5 (1) & (2)
- FOOTNOTE 'D'.
2. POSITIVE CONNECTION & TRANSFER OF LOAD
FROM ROOF TO LOAD SUPPORTING ELEMENTS
REQ'D.
3. PROVIDE ANCHORAGE OF BEAMS OR GIRDERS
TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11
4. THIS STRUCTURE TO COMPLY WITH MIN.
FASTENER SCHEDULE, IRC TABLES R602.3 (1)
THRU (5).
5. SOLID BLOCKING REQ'D @ ALL BEARING
POINTS OF FLOOR, CEILING & ROOF SYSTEMS
AS PER IRC SEC'S R502 & R802.
6. ATTIC VENTILATION PER IRC SEC R806.
7. ROOF TOTAL WIDTH NEEDS TO BE 102" OR <
@ FASCIA TO BE ROAD LEGAL IN MOST STATES
& PROVINCES.
8. 12" OVERHANG @ GABLE ENDS & 3"
OVERHANGS @ SIDES (INCLUDING FASCIA).
9. ROOF PITCH = 12:12
10. STRONG-TIE H1 HURRICANE CLIPS @ EACH
FULL BEARING RAFTER
11. STRONG-TIE RR CONNECTORS @ EACH FULL
BEARING RAFTER OR COLLAR TIES SPACED
NOT LESS THAN 48" O.C.
12. MIN. 1/2" ROOF SHEATHING.
13. PROVIDE AN INSULATION BAFFLE (I.E. A
CONTINUOUS VENT) BUILT FROM RIGID FOAM
BOARDS TO PREVENT CONDENSATION BUILD-UP
INSIDE ROOF ASSEMBLY. NOTE: VENTILATION IS
THE MOST OVERLOOKED COMPONENT OF TINY
HOUSES. PLEASE VENTILATE YOUR ROOF
SYSTEM & INSTALL ADEQUATE MECHANICAL
VENTILATION IF YOU INTEND TO USE YOUR TINY
HOUSE FOR EXTENDED PERIODS OF TIME &/OR
YOU EXPECT TO USE YOUR TINY HOUSR IN
HEAVILY CONDITIONED AREAS IN THE NORTH OR
SOUTH.

20'-0"

2'-3/4"

20'-0"

ROOF FRAMING PLAN


1/2" = 1'

05
NOTE: IN DIMENSIONING OUT FRAMING PLANS, OVERALL PATTERN SPACING IS SOMETIMES LOST. REST ASSURED THAT THESE DIMENSIONS ARE ESTABLISHED AT SET PATTERNS, EITHER 16" OR 24" O.C., TO PROPERLY MANAGE STANDARD 4X8 SHEET GOODS.

06

FULL FRAMING OVERVIEW

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

2X6 RIDGE BEAM

BUILDING NOTES:

3'-6 3/4"
2X VENTED & SCREENED BLOCKING
BARGE RAFTERS @ ENDS

7'-4"
6"

1/2" CDX PLYWOOD SHEATHING W/ 30# FELT


2X6 VENTED RAFTERS
2X VENTED BLOCKING
DBL. TOP PLATE
WHEEL WELL COVERS
BOXED & INSUL.;
CABINETRY BUILT OVER
TOP OF BOXES

7 3/4"

MAIN FLOOR SYSTEM:


3/4" T&G WOOD FLOORING
3/4" CDX PLYWOOD OR DIAG. BOARD SUBFLOOR
2X6 DF OR SPF #2 FLOOR JOISTS @ 24" O.C.
JOISTS FASTENED TO TRAILER DECKING W/ STRONG-TIE ANGLE TIES & SDS SCREWS.
FLOOR SYSTEM TIED TO TRAILER SUBSTRUCTURE W/ METAL STRAPPING.
2-3 LAYERS OF 1-1/2" THERMAX POLYISOCYANURATE BOARD INSUL. (MIN. R-19)

1'-8" +/-

2X4 LOFT JOISTS W/ 3/4" T&G


DECKING TOP & BOTTOM

SCREENED VENT
3-IN SDS SCREWS X 3

+6'-7 1/2"
TO SUBFLOOR

2X6 JOISTS @ 24" O.C. W/ R-19 INSUL.

TRAILER:
7X20 DROP DECK STYLE TRAILER.
10K CAPACITY.
20" HEIGHT FROM GROUND TO TOP OF DECKING.
MIN. 2-AXLE W/ 5000K RATING PER AXLE.

1X FASCIA

ADD SHEATHING OR
FLASHING BELOW
CANTILEVERED
FLOOR JOISTS

SECTION THRU HOUSE

1x4 LEDGER LET-IN TO STUDS

2X4 STUDS W/ 3/4" T&G INT.,


1/2" CDX PLYWOOD EXT.

1/2" = 1'

HEATING SYSTEM:
DICKINSON PROPANE FIREPLACE
CONVECTION STYLE ELECTRIC WALL BACK-UP HEATER

7'-5 3/4"

VENTILATION SYSTEM:
EXHAUST FAN @ KITCHEN (150 CFM)
EXHAUST FAN BATHS & LAUNDRY (110 CFM)
VENTED ROOF ASSEMBLY

1X4 OR 1X6 T&G


PANELS, PINE TYP.

ADD RAFTER RIDGE CONNECTORS @


FLUSH MOUNTED RAFTER, EACH SIDE

ADD 2X4 COLLAR TIES IF RR


CONNECTORS ARE NOT USED

3/4" HARDWOOD O/ BROWN


BUILDING PAPER, TYP.
3/4" PLY

08

2X6 (0R 2X8) JOISTS W/ 3/4"


CDX PLYWOOD SUBFLOOR &
1/2" CDX SHEATHING UNDER @
EXPOSED CANTILEVER

H1 HURRICANE TIE @
FULL BEARING RAFTERS
2X6 DF#2/SPF#2 RAFTERS @ 24" O.C.
W/ H1 HURRICANE TIES & MIN. R-19
INSUL.; LEAVE 1" VENTILATION GAP
(BAFFLE) B/T INSUL. & ROOF DECKING

ADD STRUCTURAL 2X
VENTED & SCREENED
BLOCKING B/T RAFTERS

TRAILER BED

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

6'-9 1/2"

STANDING SEAM METAL ROOFING

5 1/2"

6 1/2"

SECTION THRU HOUSE

LOFT FLOOR SYSTEM:


3/4" T&G WOOD DECKING
2X4 DF OR SPF #2 LOFT JOISTS @ 24" O.C.
(JOISTS FASTENED TO CORRESPONDING STUDS W/ 3-SDS SCREWS @ EACH SIDE)

TRAILER HEIGHT
FROM GROUND TO
TOP OF DECKING

1X EAVE FASCIA

08

13'-11" +/-

2X4 STUDS @ 24" O.C. W/ R-19 INSUL.

2X4 STUDS @ 24" O.C. W/ R-19 INSUL.

2X4 JOISTS @ 24" W/ 3-SDS SCREWS EACH SIDE

WALL SYSTEM:
SIDING: CEDAR CLAPBOARD
1/2" RAIN SCREEN
30# HOUSEWRAP
1/2" CDX PLYWOOD SHEATHING
2X4 DF OR SPF #2 STUDS @ 16" O.C.
HORIZ. 2X HEADERS
CAULKING AT ALL STUD JOINTS
2 LAYERS OF 1-1/2" THERMAX POLYISOCYANURATE BOARD INSUL. (MIN. R-19)
CAULKING @ PLATES
CAULKING & SEALANT @ EXT. DOORS AND WINDOWS
INTERIOR SURFACE: 3/8"-3/4" T&G WOOD PANELING
NON-TOXIC INTERIOR LATEX PAINT

2X6 RAFTERS @ 24" O.C. W/ R-19 INSUL.

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

2X4 COLLAR TIES @ 24" O.C.

ROOF SYSTEM:
ROOFING: METAL STANDING SEAM
30# FELT W/ 6" MIN HEAD & SIDE LAPS
1/2" CDX SHEATHING
2X6 DF OR SPF #2 RAFTERS @ 24" O.C.
1" AIR GAPR B/T SHEATHING & INSUL.
2-3 LAYERS OF 1-1/2" THERMAX POLYISOCYANURATE BOARD INSUL. (MIN. R-19)
3/4" T&G WOOD CEILING OR 5/8" G.W.B.
NON-TOXIC NATURAL FINISH OR LATEX PAINT.

1/2" SHEATH BELOW CANTILEVER

WALL SECTION
1"= 1'

ROOF SECTION SHOWING CONNECTIONS


3/4" = 1'

07

AIR FLOW

1" AIR GAP CONT. TO & VENTED @ RIDGE; THIS


DESIGN PREVENTS MOISTURE BUIL-UP AND
EXCESSIVE HEAT INSIDE YOUR TINY HOUSE

1X4 LEDGER BOARD LET-IN TO STUD WALL

2X4 STUD NOTCHED TO RECEIVE LEDGER

AIR GAP B/T BLOCKING & INSUL.

VENTED BLOCKING W/ MESH BUG SCREEN

NOTE: IF YOU PLAN TO LIVE IN A TINY HOUSE IN


A REGION THAT REQUIRES HEATING IN WINTER
OR A/C IN SUMMER YOU MUST VENT YOUR
ROOF ASSEMBLY. IF YOU DON'T, MOISTURE ,
CONDENSATION AND MOLD WILL BUILD UP IN
YOUR ROOF ASSEMBLY, & ON WINDOWS AND
DOORS. ADEQUATELY BUILDING FOR MOISTURE
CONTROL IS THE MOST OVERLOOKED ASPECT
OF TINY HOUSES. PLEASE DO NOT BIULD A
TINY HOUSE THAT DOESN'T HAVE A VENTED
ROOF ASSEMBLY! IF POSSIBLE, INSTALL A
SMALL PANASONIC AIR-EXCHANGER.

1/2" STRUCTURAL SHEATHING W/ SW4 SHEAR


WALL NAILING SCHEDULE & ADHESIVE

2X4 LOFT JOISTS CONNECTED TO STUDS


W/ 3-SDS SCREWS O/ 1X4 CONT. LEDGER

AIR FLOW

2
2X4 STUDS @ 24" O.C. W/
MIN. R-19 INSUL.

VENTED EAVE DETAIL


NO SCALE - ISOMETRIC

30# BUILDING PAPER

3/8" - 3/4" PLYWOOD OR WOOD RAIN SCREEN

5 BEVEL FOR EXT. CASINGS


EXT. SHEATHING
2X HEAD CASING

1"

15 BEVEL

2x6 (OR 2x8) CANTILEVERED


FLOOR JOISTS @ 24" O.C.

1 1/4"

5/4" RAILS

2"

4-1/2" CLAPBOARD W/ 3" REVEAL


SILL DETAIL

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

BOARD INSUL.INSTALLED 1" BELOW ROOF SHEATHING

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

1/2" SHEATHING O/ INSUL


BAFFLE (NOT SHOWN, INSTALL
@ TIME OF FRAMING)

2X SILL W/ CHAMFERED EDGES


5/4" APRON, OPT.

TYP. WALL TREATEMENT


NO SCALE - ISOMETRIC

INT. & EXT. WINDOW CASINGS DETAIL


1" = 1'

NOTE: POCKET-HOLE JOINERY IS A GREAT WAY TO ASSEMBLE WINDOW CASINGS AT GROUND


LEVEL. PLEASE SEE OUR BLOG ENTRY ABOUT SITE-BUILT WINDOW CASINGS TO LEARN MORE.

STRONG-TIE DDT1Z HOLD DOWN


NO SCALE

CONSTRUCTION DETAILS

08

INTERIOR VIEWS

3/4 T&G WALL PANELS

SEE WINDOW CASINGS DETAIL, PAGE 10,


FOR WINDOW TREATMENT

INSTALL ALUM. OR METAL 3"


KIT. EXHAUST VENT HERE

*NOTE: FOR DETAILED INFO. ABOUT


APPLIANCES & FIXTURES, REFERENCE
THE MATERIALS LIST ON PAGE 13.

ADD PLATFORM FOR PROPANE


CANISTER &/OR UTILITY STORAGE BOX
FOLDING DINING TABLE BUILT FROM PLANED
2X STOCK W/ DOWEL JOINERY, OR SIMILAR

SPLIT SECTION ISOMETRIC*


No Scale

4" WIDE WINE, TEA & COFFE CUP CABINET;


ADD HOOKS & BARS, AS DESIRED

SITE-BUILT 1X6 T&G BATHROOM DOOR

5 1/2"

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

3/4" WOOD FLOORING

1'-0"
120 CFM DIRECT WALL
VENT FAN UNDER
CORNER CABINET

1'-6"

BUILD TO
DESIRED HEIGHT

6'-9 1/2"

6'-9 1/2"

INSTALL OPEN PANTRY &


DRAWERS, AS DESIRED

6'-9 1/2"

5'-9 1/2"

3'-0"

2'-0"

2'-3"

1'-8 5/8"

3 5/8"

3'-0"

1'-11 5/8"

2'-0"

1'-5/8"

11 1/4"

2'-0"

7'-11 1/4"

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

USE FACTORY VENT KIT IF USING


PROPANE FIREPLACE

KITCHEN VIEWS*
1/2" = 1'

TYP. FIXTURES
1-1/4" TOP RAILS

1/2" NOTCH
1-3/4" BOTTOM RAILS

ADJ. CABINETS TO DESIRED


HEIGHTS & TO WORK
AROUND SELECTED TOILET
& SINK

6'-9 1/2"

2X LEGS, PLANED
SHELVING, OPT.

8'-6" +/-

6'-9 1/2"

2" DOWELS
OR SCREWS
TUB COMBO
OR SHOWER

2'-0"

BATHROOM VIEWS*
1/2" = 1'

11 1/4"

1'-5 1/2"

2" DOWELS

10 1/2"
2'-7"

FINISHING DETAILS

2x12 TOP, CHAMFERED & SANDED

MIRROR OR STORAGE CABINET, AS DESIRED

SCREWS

2'-7"

LOFT LADDER (IN CONTEXT)


1/2" = 1'

TINY HOUSE "SCRAP WOOD" TEA TABLE


1/2" = 1'

09

ELECTRICAL LEGEND

11
11

OGFI GFI ELECTRICAL OUTLET


WEATHER PROOF OUTLET

OR

RANGE OUTLET

11

OWP

11111111

3" DRAIN OUT, 2" VENT STACK


PORCH OUTLET HANDY FOR HOLIDAY LIGHTS

11111111

O 240 240 OUTLET

BATH EXHAUST RECOMMENDED IN COLD CLIMATES

SUGGESTED 120V CONVECTION STYLE


WALL HEATER (HARDWIRE OR PLUG)

WATER HEATER

11

PROPANE FIREPLACE
(SEE MATERIALS LIST)

WH
GFI

SMOKE DETECTORS & CARBON MONOXIDE ALARMS:


1. PROVIDE SMOKE DETECTORS AS PER WITH IRC R314.3.
2. FOR SOLID FUEL HEATERS, PROVIDE UL-2034
APPROVED CARBON MONOXIDE ALARMS INSIDE SLEEPING
LOFT IN ACCORDANCE WITH IRC R315.2 O

OGFI

11

11

11

11

11

1-1/2" WASHING MACHINE DRAIN UNDER COUNTER TO SINK DRAIN

OWP
OWP 30-AMP RV INLET

11

WIRING:
1. 30 AMP SINGLE POLE INLET TO 30 AMP PANEL: 10-2
2. 20 AMP CIRCUIT 1 (BATH): 12-2
3. 20 AMP CIRCUIT 2 (KITCHEN GFI'S): 12-2
4. 15 CIRCUIT 3 (DINING AREA, OFFICE): 14-2
5. 15 CIRCUIT 4 (LIVING ROOM): 14-2
6. 20 CIRCUIT 5 (EXT. GFO OUTLETS): 12-2
7. ALT. OPT. ALL CIRCUITS = 20 AMP W/ 12-2

WASHER

11

ELECTRICAL NOTES
GENERAL:
1. ALL KITCHEN, BATHROOM & EXT. OUTLETS TO BE GFI.
2. EXTERIOR OUTLETS TO BE WEATHER PROOF.
3. AFCI REQ'D IN SLEEPING AREAS.

UNDER COUNTER WATER HEATER

11

WH

SINGLE POLE 30 AMP BREAKER PANEL

MAIN FLOOR ELECTRICAL, PLUMBING & LPG PLAN


1/2" = 1'

PLUMBING:
1. KITCHEN SINKS: DWV MIN. 2" DRAIN & 1 1/2" VENT.
2.BATHROOM SINKS: DWV MIN. 1 1/4 DRAIN & VENT.
3. BATHTUBS: MIN. 2" DRAIN & 1 1/2" VENT.
4. SHOWERS: MIN. 1 1/2" DRAIN & VENT.
5. INCOMING WATER SUPPLY LINE: TYP. 3/4" - 1"
6. PRIMARY WATER SUPPLY LINE: TYP. 3/4"
7. INTERIOR WATER SUPPLY LINES: TYP. 1/2"
8. MAIN DRAIN LINE: TYP. 3"
9. MAIN STACK VENT: TYP. EQUAL OR > THAN MAIN DWV
LINE.
10. IF YOU LIVE IN CANADA, OR HAVE ACCES TO SMALLER
DWV PIPING, CONSIDER USING 1-1.4" DIA. IN LIEU OF 1-1/2" FOR
EASIER INSTALLATION IN WALLS.

STUB OUT FOR 1/2" SCHEDULE 40 STEEL PIPE OR GASFLEX TUBING FOR PROPANE FIREPLACE, IN-WALL &
CONT. TO APPLIANCE. OPT. TEE-OFF FOR PROPANE
STOVE @ KITCHEN.

11

$3

TO
MA
IN F
LOO
RS
WIT
CO

CH

O
I

CARBON MONOXIDE DETECTOR

OGFI

CO

SMOKE DETECTOR

$$
SD

SD

OWP

DIRECT VENT WALL VENT

OGFI

TO LOFT

11

CEILING EXHAUST FAN

11

PULL SWITCH CEILING LIGHT

WALL LIGHT (WEATHER PROOF)

1/1/2" DRAIN, 1-1.2" HORIZ. VENT TO STACK

11

$3

CEILING LIGHT (WEATHER PROOF)

1-1/2" DRAIN, 1-1/2" HORIZ. VENT TO STACK

WALL LIGHT

O O O O O
I
I

$$

CEILING LIGHT

O
I

3-WAY WALL MOUNTED LIGHT SWITCH

11

$3

SINGLE POLE WALL MOUNTED LIGHT SWITCH

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

SWITCHED ELECTRICAL OUTLET

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

OS

11

VENT FIREPLACE WITH MANUFACTURER'S EXHAUST BELL/BOOT

ELECTRICAL, PLUMBING & LPG LINE PLAN

STANDARD ELECTRICAL OUTLET (DUPLEX)

11

LOFT ELECTRICAL PLAN


1/2" = 1'

10

1 MATERIALS
ESTIMATE ONLY

WINDOW
SYMBOL

UNIT SIZE

R.O.

TYPE

FINISH

GLASS

REMARKS

ITDH 2248

1'-10" X 4'-0"

1' 10-1/2" X 4' 0-1/4"

DOUBLE HUNG

WOOD/FG

CLEAR

2W1H LITES

ITDH 2236

1'-10" X 3'-0"

1' 10-1/2" X 3' 0-1/4"

DOUBLE HUNG

WOOD/FG

CLEAR

2W1H LITES

CUAWN 1620

1'-6" X 1'-8"

1' 5" X 1' 7 5/8"

AWNING

WOOD/METAL

CLEAR

2W1H LITES

QUANTITY MANF./STYLE MODEL NO.

MARVIN
INTEGRITY
MARVIN
INTEGRITY
MARVIN
INTEGRITY

DOOR SCHEDULE
WINDOW
SYMBOL

QUANTITY MANF./STYLE MODEL NO.

DOOR SIZE

R.O.

TYPE

FINISH

GLASS

REMARKS

SIMPSON

N/A

2' 0" X 6' 4"

25-1/2" X 78"

ENTRY

SOLID WOOD

CLEAR

6-PANEL OR CRAFTSMAN STYLE, GLASS OPT.

SITE-BUILT

N/A

1' 6" X 6' 6"

TBD

INTERIOR

SOLID WOOD

NONE

3/4" T&G PANEL (CAN BE WIDER, IF DESIRED)

2 SCHEDULES
WINDOWS & DOORS

CLOSING NOTES:

OUR BASIC TOOLBOX:

1. ALL SHEATHING IS STRUCTURAL & SHOULD BE NAILED, SCREWED & GLUED TO


FRAMING MATERIAL. FOR NON-TOXIC ADHESIVES, PLEASE VISIT OUR RESOURCES PAGE AT
OUR WEBSITE.

BORING TOOLS:
1. PORTABLE DRILL-DRIVER
2. CORDED DRILL
3. SQUARE & PHILLIPS HEADS
4. SMALL DIAM. BRAD-POINT DRILL BIT SET
5. POCKET HOLE JIG
6. DOWELING JIG

2. WE RECOMMEND INSULATING YOUR ROLLING BUNGALOW TO A MIN. OF R-19 ALL


AROUND (FLOORS, WALLS & CEILING) USING RIGID FOIL-FACED FOAM BOARDS. AND BE
SURE TO MAKE A VENTED INSULATION BAFFLE PART OF YOUR ROOF ASSEMBLY.
3. IF YOU INTEND TO HAVE A BATHROOM & KITCHEN IT IS IMPERATIVE TO
INSTALL PROPER MECHANICAL VENTILATION. TINY SPACES WILL ACCUMULATE
MOISTURE FAST, ESPECIALLY DURING COLD WEATHER. MOISTURE CAN BE MANAGED BY
EXHAUST FAN(S) AT CRUCIAL POINTS (BATHROOM & KITCHEN) & FULLY VENTING
THE ROOF ASSEMBLY.
4. IF YOU CHOOSE A LARGER SIZED REFRIGERATOR (AS WE DID) YOU SHOULD
INSTALL IT PRIOR TO HANGING YOUR FRONT DOOR (OR BE SURE YOUR APPLIANCE
DOORS CAN BE TEMPORARILY REMOVED). USE SCREWS TO SET YOUR DOOR JAMBS
IN CASE YOU EVER NEED TO REPLACE THE APPLIANCE. MOST REFRIGERATORS HAVE
REMOVABLE DOORS, WHICH WILL ASSIST YOU SHOULD YOU NEED TO REMOVE IT AT SOME
POINT.
5. A 30-AMP CONNECTION IS MORE THAN ADEQUATE TO RUN A FRIDGE, WATER
HEATER, ELECTRIC COOKTOP, COMPUTER, LIGHTS, AND MORE, AS SHOWN IN THIS PLAN. IF
YOU'RE UNFAMILIAR WITH ELECTRICAL WIRING, CONTACT AN ELECTRICIAN TO DO A
"ROUGH-IN" JOB AND PROOF READ YOUR PLAN.
6. THE 2012 IRC (INTERNATIONAL RESIDENTIAL CODE) IS A GREAT RESOURCE FOR
GENERAL CONSTRUCTION INFORMATION. IF YOU BUY ONE, YOU SHOULD BE ABLE TO
EASILY SELL IT BACK ONLINE. AND MOST LIBRARIES HAVE THE IRC AVAILABLE. PLEASE
USE ONE TO ASSIST YOU WHILE BUILDING TO AVOID CONSTRUCTION MISTAKES.
7. PLUMBING WATER LINES CAN BE 1/2" PEX LINES. A SIMPLE CRIMPING TOOL CAN BE
BOUGHT FOR LESS THAN $100. TYP. HOUSE PLUMBING HARDWARE WORKS GREAT. A
GOOD LIBRARY BOOK AND SOME BASIC TOOLS IS ALL YOU NEED TO DO YOUR OWN
ROUGH-IN PLUMBING. IT'S EASIER THAN YOU MIGHT THINK. BLACK ABS PIPE IS MORE RIGID
AND WORKABLE THAN WHITE PVC.
8. CANVAS WHEEL COVERS ARE A GOOD INVESTMENT BECAUSE SUN WILL DEGRADE
YOUR TIRES.
9. PLEASE INSTALL A SMOKE DETECTOR IN YOUR TINY HOUSE. A CO2 DETECTOR IS REQ'D
IF YOU INSTALL A FIREPLACE. AND ALWAYS KEEP A FIRE EXTINGUISHER ON HAND IN YOUR
HOUSE.
10. EXPOSED EXTERIOR WATER PIPES CAN BE INSULATED (OR HEAT TAPED). IF YOUR
AREA GETS COLD, ADDING ROCK SALT TO YOUR WASTE WATER LINES SHOULD PREVENT
FREEZING.

HAMMERING TOOLS:
1. WOODEN DALLUGE STYLE FRAMING HAMMER
2. 12 OZ. ESTWING STYLE FINISHING HAMMER
3. BRAD NAILER W/ LIGHTWEIGHT COMPRESSOR
4. FLOORING HAMMER (RENTED)
5. CHISELS
CUTTING TOOLS:
1. 10" TABLE SAW
2. CIRCULAR SAW W/ 96" TRACK
3. D-HANDLE JIGSAW
4. SLIDING COMPOUND MITER SAW
5. HAND SAW(S)
MEASURING & MARKING TOOLS:
1. FRAMING SQUARE
2. SPEED SQUARE
3. FOLDING CABINET RULER
4. COMBINATION SQUARE
5. 12" STEEL RULER
6. CHALK LINE
7. SPEED LEVEL
8. 48"-96" LEVEL
PLANING TOOLS:
1. HAND PLANER
2. BENCH PLANER

WE USE A VARIETY OF PLUMBING, GAS & ELECTRICAL AND HAND CABINET


TOOLS. IF YOU HIRE THESE SERVICES OUT THEN YOU CAN FOREGO
PURCHASING ADDITIONAL TOOL.S (RECOMMENDED IN MOST CASES).

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

WINDOW SCHEDULE

THE FREE SHARE TINY HOUSE ROLLING BUNGALOW

FLOOR SYSTEM:
1. 2X6X8 DF#2 (17)
2. 2X6X10 DF#2 (2)
3. 2X6X12 DF#2 (2)
4. 3X4X8 POLYISO RIGID FOAM BOARD INSULATION (5)
5. 3/4" CDX PLYWOOD (5)
6. 160 SQ. FT. BROWN BUILDING PAPER
7. 160 SQ. FT OF 3/4" FINISH FLOORING
PORCH:
1. P.T. OR CDR 2X4X8 (2)
2. 2X4X8 CDR DECKING (9)
3. 4X4X8 CDR POST (1)
WALLS:
1. 2X4X8 DF#2 (75)
2. 2X4X10 DF#2 (4)
3. 2x4x12 DF#2 (2)
4. 2X6X8 DF#2 (4)
5. 1/2" CDX PLYWOOD (17)
6. 3X4X8 POLYISO RIGID FOAM BOARD INSULATION (16)
7. 500-600 SQ. FT. OF 3/8" - 3/4" T&G INT. PANELING OR 1/2" G.W.B.
8. 500 SQ. FT. BUILDING PAPER OR HOUSEWRAP
9. 500 SQ. FT. OF SIDING
LOFT FLOOR:
1. 2X4X8 DF#2 (8)
2. 1X4X10 DF#2 (2)
3. 5/8" 0R 3/4" T&G DECKING (100 SQ. FT)
ROOF:
1. 2X6X8 DF#2 (30)
2. 2X4X8 DF#2 (5)
3. 2X4X12 DF#2 (2)
4. 1X8X8 DF#2 OR CDR (4)
5. 1X6X10 DF#2 OR CDR (4)
6. 3X4X8 POLYISO RIGID FOAM BOARD INSULATION (10)
7. 1/2" CDX PLYWOOD (10)
8. 265 SQ.. FT. OF ROOFING PAPER & ROOFING MATERIAL (YOUR CHOICE).
MISCELLANEOUS FRAMING MATERIALS:
1. 16D, 10D AND 8D NAILS &
2. 1/4" X 3" SDS SCREWS
3. A23 RIGHT ANGLE CLIPS: 60
4. METAL STRAPPING
5. 4 HDU2 STRONG-TIE HOLD DOWNS
6. NON-TOXIC ADHESIVE (ECOBOND, CHEMLINK, ET AL.)
WINDOWS & DOORS:
(SEE SCHEDULES)
ELECTRICAL & PLUMBING:
(SEE PAGE 10)
KITCHEN FIXTURES & APPLIANCES:
1. REFRIGERATOR MODEL LG #LRBP1031W
2. THE BREVILLE SMART OVEN MODEL #BOV800XL
3. HAIER SPACE-SAVING PORTABLE COMPACT ELECTRONIC 1 CUBIC FOOT TOP LOAD WASHER MODEL #
HLP21N.
4. FULL SIZE IKEA SINK BOHOLMEN SINK
5. STANDARD TWO-BURNER BOAT OR RV STYLE PROPANE COOK TOP
6. OPTIONAL INDUCTION COOK TOP (MECHANICAL FAN & VENTING RECOMMENDED FOR FULL-TIME USE)
7. STIEBEL-ELTRON WATER HEATER MODEL #SHC4
8. LEE VALLEY CABINET HARDWARE (1-1/4" CHROME PLATE CATCHES & STAINLESS STEEL HINGES)
BATHROOM FIXTURES:
1. LYONS (OR SIMILAR) 24" X 32" RV/BOAT BATHTUB WITH RIGHT SIDE DRAIN RECOMMENDED WITH CEDAR
SHOWER SURROUND
(SITE-BUILT USING CEDAR SIDING & MIRACLE COVER NON-TOXIC MARINE SEALER) OR FIBERGLASS
SHOWER PANELS.
2. CORONA PROFILE SMART 305 WITH INTEGRATED SINK
3. BRICOR B100 ULTRA-MAX SHOWER HEAD*
LIVING & DINING ROOM:
1. IKEA SOLSTA COUCH
2. LEE VALLEY 4-POSITION FOLDING BRACKETS (2) FOR FOLDING DINING TABLE
3. IKEA JOKK MOKK DINING TABLE CHAIRS (2)
4. NEWPORT PROPANE BOAT FIREPLACE BY DICKINSON MODEL #P9000
5. CONVECTION STYLE WALL HEAER (120V) - HARDWIRED OR PLUG - LOCATE AS DESIRED
MISCELLANEOUS FINISHING MATERIALS:
1. CABINETRY MATERIALS TO BE ESTIMATED BY BUILDER.
2. BUILT-IN FURNITURE MATERIALS TO BE ESTIMATED BY BUILDER.
3. ANY OTHER CHANGES MADE BY OWNER OR BUILDER.
4. NON-TOXIC CAULKING FOR SEALING
5. SPRAY-FOAM FOR WINDOW SEALING

IMPORTANT: VERIFY ALL WINDOW & DOOR INFORMATION W/ MANUFACTURER PRIOR TO CONSTRUCTION.

MATERIALS, SCHEDULES & CLOSING NOTES, ETC.

DISCLAIMER: THIS IS AN ESTIMATE OF THE MATERIALS YOU'LL NEED TO COMPLETE YOUR TINY HOUSE. IT
WILL HELP GAUGE COSTS AND ASSIST WITH THE PRIMARY ORDER & DELIVERY. BE SURE TO CALCULATE
10% FOR WASTE, ETC. (BUT DON'T WASTE IT! BUILD SCRAP-WOOD FURNITURE FOR YOUR HOUSE). KEEP IN
MIND ADDITIONAL MATERIALS WILL LIKELY BE REQ'D. SINCE YOUR INDIVIDUAL PREFERENCES WILL FINISH
YOUR HOUSE. IT IS A PRIVILEGE & A JOY TO BUILD. YOUR COOL FOR TAKING ON THE CHALLENGE OF
CREATING YOUR OWN HOUSE! REMEMBER TO WORK SAFELY...

11. BE SURE NOT TO EXCEED YOUR TRAILERS WEIGHT CAPACITY. WEIGH YOUR
TRAILER BEFORE YOU START & USE A BATHROOM SCALE TO HELP YOU ESTIMATE
WEIGHT AS YOU BUILD (OUR OWN TINY HOUSE WEIGHS ABOUT 8,000 LBS).

11