Anda di halaman 1dari 16

IT T

Goulds Pumps
G&L Series NPO

Open Impeller All Stainless Steel End Suction Pumps

www.goulds.com

Engineered for life

Commercial Water

A Full Range of Product Features

NPO Product Line Numbering System

Superior Materials of
Construction: Complete AISI
316L stainless steel liquid handling components and mounting
bracket for corrosion resistance,
quality appearance, and improved
strength and ductility.

Example Product Code


1 SN 2 C 1 A 4 F
Seal Vent/Flush Option
Mechanical Seal and O-ring
4 = Pre-engineered standard
For optional mechanical seal modify catalog order no.
with seal code listed below.

Open Impeller Design: Open


impeller design passes up to 38"
solids including food particles,
lint, metal filings, and other wash
residue.
Casing and Adapter Features: Stainless steel construction
with NPT threaded, centerline connections, easily accessible vent,
prime and drain connections with
stainless steel plugs. Optional seal
face vent/flush available.

John Crane Type 21 Mechanical Seal (58 seal)

Mechanical Seal: Standard


John Crane Type 21 with carbon
versus silicon-carbide faces, Viton
elastomers, and 316 stainless
metal parts. Optional high temperature and chemical duty seals
available.

GOULDS PUMPS
Commercial Water

Casing
O-Ring
EPR
Viton
EPR
Viton

Impeller Option
For optional impeller diameters modify catalog order no.
with impeller code listed. Select optional impeller diameter from
pump performance curve.

Motors: NEMA standard open


drip-proof, totally enclosed
fan cooled or explosion proof
enclosures. Rugged ball bearing
design for continuous duty under
all operating conditions.

The various versions of the NPO are


identified by a product code number
on the pump label. This number is
also the catalog number for the
pump. The meaning of each digit in
the product code number is shown in
the Product Line Numbering System
chart.

Part
Seal






Metal
No.

Code

Rotary Stationary Elastomers Parts






2

EPR
10K18
Carbon
4
Sil-
Viton
10K55
316 SS
5
Carbide
EPR
10K81
Sil 6
Viton
10K62
Carbide

Impeller Code



A

B

C

D

E

F

G

H

1 x 1 6
Diameter
4516
4
3
3
3
3
538
5

Pump Size
1 x 1 6
Diameter

1 x 2 6
Diameter

5516
5116
458
4516
4116
3
3716

5716
5
41516
458
4716
4316
3

Driver
1 = 1 PH, ODP 6 = 575 V, TEFC
2 = 3 PH, ODP 7 = 3 PH, XP
3 = 575 V, ODP 8 = 575 V, XP
4 = 1 PH, TEFC 0 = 1 PH, XP
5 = 3 PH, TEFC
HP Rating
C = HP E = 1 HP G = 2 HP J = 5 HP
D = HP F = 1 HP H = 3 HP
Driver: Hertz/Pole/RPM

For
frame
mounted
version,
substitute the
letters FRM in
these positions.

1 = 60 Hz, 2 pole, 3500 RPM


2 = 60 Hz, 4 pole, 1750 RPM
4 = 50 Hz, 2 pole, 2900 RPM
5 = 50 Hz, 4 pole, 1450 RPM
Material
SN = Stainless steel
Pump Size
1 = 1 x 1 6 2 = 1 x 1 6 3 = 1 x 2 6


Performance Coverage (60 Hz)
METERS

FEET

120

TOTAL DYNAMIC HEAD (H)

30

25

100

80

20
60

15

1" x 114" 6
3500 RPM

40
10

112" x 2" 6
1750 RPM

20

1" x 114" 6
1750 RPM
0

114" x 112" 6
1750 RPM
50

25

112" x 2" 6
3500 RPM

114" x 112" 6
3500 RPM

10

75

15

100

20

125

25

150

30

35

175

40

200

45

225 U.S. GPM 250

50

m/hr

CAPACITY (Q)

Notes:
Not recommended for operation
beyond printed H-Q curve.
For critical application conditions
consult factory.
Not all combinations of motor,
impeller and seal options are
available for every pump model.
Please check with G&L Pumps on
non-cataloged numbers.
All standard 3500 RPM ODP and
TEFC motors supplied by Goulds
Pumps, have minimum of 1.15
service factor. Standard catalog
units may utilize available service
factor. Check available service factor for all motors not supplied by
Goulds Pumps.

GOULDS PUMPS
Commercial Water

NPO Close Coupled Pump Major Components: Materials of Construction


100

349
(1SN ONLY)

304

408

513 101

383

370

108

240
412B

184

371

123
184A

Item No., Description Materials





100 Casing

AISI 304 SS

101 Impeller

AISI 316L SS



108
Motor adapter

AISI 316L SS

Motor adapter seal vent/flush


108A

123 Deflector

108A

BUNA-N

184 Seal housing

AISI 316L SS


Seal housing seal vent/flush
184A

240 Motor support Steel


304 Impeller locknut AISI 304 SS


349 Seal ring, guidevane Viton

Seal Face Vent/Flush Option. Image shown with NPE impeller.


Socket head screws, casing AISI 410 SS


Bolts, motor Plated steel
371


370

383 Mechanical seal **see chart





Drain and vent plug, casing
AISI 316L SS
408



O-ring, drain and vent plug
412B

513 O-ring, casing

Viton

Motor NEMA standard, 56J flange





Bearing frame, greased for life

Iron

GOULDS PUMPS
Commercial Water

, and 1 HP
Footed motor for 5 HP, ODP and TEFC,
all explosion proof. See page 11.


Performance Curves 60 Hz, 3500 RPM

METERS

FEET

NPSH R FEET



Ordering Standard Imp.
Code HP Rating Dia.

6'

90 G 5 8" DIA.
3

25

NOTE: Not recommended for operation beyond


printed H-Q curve.

Model NPO / 1SN Size 1 x 114-6


RPM 3500 Curve CN0423R01

25 EFF %

H 5"

8'
10'

30

80

TOTAL DYNAMIC HEAD (H)

12'

20

70

15

25

B 4"

50 C 334"
D 312"

40
10

30

A 4516"

60

18'

E 3 4"
30 F 3"

20

32

10

3"

4516

538

10

20

30

3
P
2 H 4 HP
P

32

1 1

1H

40

50

60

10

HP

NOTE: Although not


recommended, the pump
may pass a 38" sphere.

HP

HP

70

80

90 U.S. GPM

20

15

m3 hr

CAPACITY (Q)

METERS

NOTE: Not recommended for operation beyond


printed H-Q curve.

Model NPO / 2SN Size 114 x 112-6


RPM 3500 Curve CN0470R00

FEET





Ordering Standard Imp.
Code HP Rating Dia.

35
A 5516" DIA.
30

TOTAL DYNAMIC HEAD (H)

25

100

B 5116"

30 EFF %

3' NPSH R FEET

80 C 458"

20

6'

40

42

9'

D 4516"
60

3716

4116

4516

458

5116

5516

12'

E 4116"

44

42

15'

F 334"

15

40

40 G 3 16"
7

10

20

1 1

1H
P

4 H
P

20

40

60

10

80
15

100

20

HP

120

25

3H

2H
P

NOTE: Although not


recommended, the pump
may pass a 38" sphere.

160

140
30

35

U.S. GPM
m3 hr 40

CAPACITY (Q)

GOULDS PUMPS
Commercial Water

Performance Curves 60 Hz, 3500 RPM

METERS

NOTE: Not recommended for operation beyond


printed H-Q curve.

Model NPO / 3SN Size 112 x 2-6


RPM 3500 Curve CN0473R00

FEET



Ordering Standard Imp.
Code HP Rating Dia.

120

35

TOTAL DYNAMIC HEAD (H)

30

25

100

C 41516" DIA.

5' NPSH R FEET


40 EFF %
45
10'

D 458"
80 E 4716"

15'
50

20'

25'

52

F 4 16"
3

45

20

30'

60 G 334"

35'

40

3"

4316

4716

458

41516

5H

10

NOTE: Although not


recommended, the pump
may pass a 38" sphere.

15

20

2
0

100

50

10

15

20

HP

150

25

30

HP

200

35

40

U.S. GPM

45

50 m hr 55

CAPACITY (Q)


Performance Curves 60 Hz, 1750 RPM

METERS

Model NPO / 1SN Size 1 x 114-6


RPM 1750 Curve CN0468R00

FEET

G 538" DIA.

NOTE: Not recommended for operation beyond


printed H-Q curve.

23 EFF %

H 5"

TOTAL DYNAMIC HEAD (H)

28

20

2' NPSH R FEET

A 4 16"
5

5
15

2
3'

B 4"

5'

C 334"

1
2

D 3 2"
1

10

HP

E 314"

F 3"

2
5

30
0

10

15

3"

4516

538

NOTE: Although not


recommended, the pump
may pass a 38" sphere.

30





Ordering Standard Imp.
Code HP Rating Dia.

20

25

30

35

40

U.S. GPM

10 m3 hr

CAPACITY (Q)

GOULDS PUMPS
Commercial Water

Performance Curves 60 Hz, 1750 RPM

METERS

FEET

30

Model NPO / 2SN Size 114 x 112-6


RPM 1750 Curve CN0471R00

25

TOTAL DYNAMIC HEAD (H)

30 EFF %

B 5116"

2' NPSH R FEET (PIES)


38
40

5
20 C 4 8"

3'

D 4516"
15

42

4'

E 4116"

4
3

Ordering Standard
Code HP Rating Imp.


Dia.

A 5516" DIA.

NOTE: Not recommended for operation beyond


printed H-Q curve.

3716"

4116

4516

458

5116

5516

40

F 334"

5'

7
10 G 3 16"

2 H
P

2
5

NOTE: Although not


recommended, the pump
may pass a 38" sphere.

1
0

10

30

20

50

40

70

60

10

80

15

U.S. GPM
m hr 2

CAPACITY (Q)

METERS

FEET

30

A 5716" DIA.

B 514"

8
25

TOTAL DYNAMIC HEAD (H)

3' NPSH R FEET

43 EFF %
48

C 41516"

NOTE: Not recommended for operation beyond


printed H-Q curve.

Model NPO / 3SN Size 112 x 2-6


RPM 1750 Curve CN0474R00

D 458"
20 E 4716"

F 4 16"

48 6'

50

43

9'

15 G 334"

4
3

10

3
4
1
2

HP





Ordering Standard Imp.
Code HP Rating Dia.

3"

4316

4716

458

41516

5716

NOTE: Although not


recommended, the pump
may pass a 38" sphere.

HP

5
1
0

20
5

40

80

60
10

15

100

20

120
25

U.S. GPM

30 m3 hr

CAPACITY (Q)

GOULDS PUMPS
Commercial Water

Performance Curves 50 Hz, 2900 RPM

METERS

NOTE: Not recommended for operation beyond


printed H-Q curve.

Model NPO / 1SN Size 1 x 114-6


RPM 2900 Curve CN0469R00

FEET

Optional Impeller


Ordering Code Dia.

20
G 538" DIA.

60

20 EFF %

4' NPSH R FEET (PIES)


25

H 5"

30

15

50

7'

A 4 16"

TOTAL DYNAMIC HEAD (H)

30

12'
25

40 B 4"
C 334"

10

30 D 312"

E 314"

HP

20 F 3"
1 1

32

10

10

20

H
P

2 H

30

40

4516"

538

NOTE: Although not


recommended, the pump
may pass a 38" sphere.

1H

3
4

32

HP

50

60

70

10

U.S. GPM

15

m3 hr

CAPACITY (Q)

METERS

NOTE: Not recommended for operation beyond


printed H-Q curve.

Model NPO / 2SN Size 114 x 112-6


RPM 2900 Curve CN0472R00

FEET

Optional Impeller


Ordering Code Dia.

80

A 5516" DIA.

70
20

30 EFF %
2' NPSH R FEET

B 5116"

TOTAL DYNAMIC HEAD (H)

60

40

C 458"
15

4' 42

50

6'

D 4516"

44

8'

40 E 4116"

10

40 10'

G 3716"
2H

20

5
3

10

2 H
P

20

40

60

10

80
15

4 H
P

1 1

1H

120

100
20

5516"

5116

458

4516

4116

3716

42

F 334"
30

25

HP

NOTE: Although not


recommended, the pump
may pass a 38" sphere.

U.S. GPM

30 m3 hr

CAPACITY (Q)

GOULDS PUMPS
Commercial Water


Performance Curves 50 Hz, 2900 RPM

METERS

80

4' NPSH R FEET


40 EFF %

70

20

TOTAL DYNAMIC HEAD (H)

45

C 4 16"
15

60

10'
50

D 458"
E 4716"

50

14'

50

52

F 4316"

17'

45

20'

3
40 G 3 4"

10

24'

5H

30

20

5
1

10

0
0

50
5

Optional Impeller


Ordering Code Dia.

A 5716" DIA.
B 514"

15

NOTE: Not recommended for operation beyond


printed H-Q curve.

Model NPO / 3SN Size 112 x 2-6


RPM 2900 Curve CN0475R00

FEET

10

HP

100
15

20

11
2 H
P

3H

25

30

35

200
40

45

5716"

41516

458

4716

4316

NOTE: Although not


recommended, the pump
may pass a 38" sphere.

HP

150

U.S. GPM

50 m3 hr 55

CAPACITY (Q)

GOULDS PUMPS
Commercial Water

NPO Close Coupled Dimensions, Weights and Specifications

Clockwise Rotation Viewed from Drive End


Y
DISCHARGE

C MAX.

1 PHASE ONLY

22132

FILL AND VENT


SUCTION

4
30
TYP

6516
MAX.
31116
MAX.

DRAIN

32 DIA. HOLE 4-MOUNTING HOLES

13

2 16

2 16

15

15

16

678

6 MAX.

ODP and TEFC , and 1 HP


Y
DISCHARGE

C MAX.
1 PHASE ONLY

FILL AND VENT


X

SUCTION

2516
MAX.
3
4 4 16
MAX.
11

30
TYP

DRAIN

32 DIA. HOLE
4-MOUNTING HOLES
13

21516

21516

818

5
8

1 32
31

ODP and TEFC 1, 2 and 3 HP



Dimensions Determined by Pump
Pump

Suction
Discharge



HP

1SN

3 516

438

4916

7516

2SN

218

5 18

7 78

3SN

1 7

4 8

2 8

5 8

7 78

Available Motor Weights and Dimensions


Motor Weights
HP



1
1
2
3
5

ODP
16
19
22
28
33
40
42

1 Phase
TEFC
21
24
26
35
39
43

EXP
47
41
49
56
60

Dimensions in inches, weights in pounds.

GOULDS PUMPS
Commercial Water

ODP
19
21
23
27
32
41
42

3 Phase
TEFC
18
21
21
27
33
37
45

EXP
27
30
30
37
44

C Max.
Length
101516
11
11
12
1258
12
14

Notes:
1. Pump will be shipped with top
vertical discharge position as
standard. For other orientations,
remove casing bolts, rotate discharge to desired position, replace
and tighten 6mm b olts to 5 6
lbs.-ft.
2. Motor dimensions may vary with
motor manufacturers.
3. Dimensions in inches, weights
in pounds.
4. For explosion proof motor
dimensions consult factory for
information.
5. Not to be used for construction
purposes unless certified.

10

NPO Close Coupled with Footed Motor 5 and 7 HP units and all Explosion proof
All Explosion Proof Motors and 5 HP ODP and TEFC and 7 HP ODP
Y
DISCHARGE

C MAX.

1 PHASE ONLY

1916

FILL AND VENT


SUCTION

X
7
MAX.
11
3 4 3 16
MAX.

30
TYP

DRAIN

2716

2716
6

32 DIA. HOLE
4-MOUNTING HOLES
11

3
578 MAX.

Specifications

Capacities to:
120 GPM (283L/min) at 1750 RPM
200 GPM (550L/min) at 3500 RPM
Heads to:
30 feet (11 m) at 1750 RPM
100 feet (50 m) at 3500 RPM
Working pressures to:
125 PSIG (9 bars)
Maximum temperatures to:
212F (100C) with standard seal
or 250F (121C) with optional
high temperature seal.
Direction of rotation:
Clockwise when viewed from
motor end.

Motor specifications:
NEMA 56J frame, 1750 RPM,
and HP. 3500 RPM
through 5 HP. Open drip-proof, totally enclosed fan-cooled explosion
proof enclosures. Stainless steel
shaft with ball bearings.
Single phase: Voltage 115/230
ODP and TEFC. (3 HP model 230
V only) Built-in overload with autoreset provided.
Three phase: Voltage 208-230/460
ODP, TEFC and EX PROOF.
NOTE: For three phase motors,
overload protection must be
provided in starter unit. Starter
and heaters must be ordered
separately.

GOULDS PUMPS
Commercial Water

11

NPO Frame Mounted Dimensions, Weights and Specifications

3
SPACER COUPLING

CP MAX.

FILL AND
VENT
SUCTION

578 MAX.
DISCHARGE

C MAX.
1 PHASE ONLY

318
MAX.

COUPLING GUARD
2

778
MAX.

31116
4 MAX.

30
TYP

DRAIN

7
8
KEYWAY 332 x 316
CHAVATERO 332 x 316

HD

HE

HG

HE
HA

HP

HF
HB

HL

11
32 DIA. HOLE
4-MOUNTING
HOLES


Specifications
Capacities to:
120 GPM (283L/min) at 1750 RPM
200 GPM (550L/min) at 3500 RPM

Motor specifications:
T-frame single and three phase.
Open drip-proof, TEFC or explosion
proof enclosures are available
for 60 Hz, 3500 and 1750 RPM
operation.

Heads to:
30 feet (11 m) at 1750 RPM
100 feet (50 m) at 3500 RPM

For three phase motors, overload


protection must be provided in
starter unit. Starter and heaters
must be ordered separately.

Working pressures to:


125 PSIG (9 bars)
Maximum temperatures to:
212F (100C) with standard seal
or 250F (121C) with optional
high temperature seal.
Direction of rotation:
Clockwise when viewed from
motor end.


NPO-F

CP MAX.

DISCHARGE

4 1 4

FILL AND VENT


SUCTION

2
7 /8

4 1 2
DRAIN
2

5 1 4

GOULDS PUMPS
Commercial Water

KEYWAY 332 x 316

31116
4 MAX.

4 HOLES 38 DIA.
L

3 1 4
41316

916

1 2

12

Dimensions and Weights Determined by Pump

Dim. "HL" Determined


by Pump and Motor



Frame
Pump Suct. NPT Disch. NPT CP
L
W
X
Y
Wt.
56 140 180



1SN
1 14
1
121516
6 716
35/16
438
2
22 12
4 916
6716

2SN

1 12

114

4 12

3SN

4 58


13 12
7
3 34
1 2

2 1/8

23

518


Available Motor and Bedplate Dimensions and Weights
Horsepower
Motor Frame HA



56
143T
145T

182T
184T

10

HB

26

HD

HE

HF

HG HP

6 78 3 18 22 38 238

Wt.
Max.

30

3500 RPM

Shims

Frame
Size

1"

ODP

26

7 14

3 34

Notes:
1. Pump will be shipped with top
vertical discharge position as
standard. For other orientations,
remove casing bolts, rotate
discharge to desired position,
replace and tighten 6mm bolts
to 5 6 lbs.-ft.

24

234

43

Single Phase

56

2 1 2

Three Phase

TEFC

143T

2 1 2

145T

182T

184T

ODP

Wt.
Max.

TEFC
2 1

13

45

112

13 38

45

1 12 3
5

112 2
3

14 14
16 58

18 18

2 1
112

C Max.

52
63
112

2. Motor dimensions may vary


with motor manufacturers.
3. Dimensions in inches, weights
in pounds.
4. For explosion proof motor
dimensions consult factory for
information.
5. Not to be used for construction
purposes unless certified.

GOULDS PUMPS
Commercial Water

13

Typical Applications
Specifically designed for a broad range of general applications traditionally requiring various materials such as all iron,
bronze fitted or all bronze construction.
Dish washers
Bottle and glass washers
Commercial laundry systems
Parts washers
Machine tool coolant
Water circulation
Booster service
Liquid transfer
Spray system
Chillers
Washing/cleaning systems
Air scrubbers
Filtration systems
OEM applications
General water services

GOULDS PUMPS
Commercial Water

14

Notes

GOULDS PUMPS
Commercial Water

15

IT T

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

2007 ITT Corporation

Engineered for life

Commercial Water

Anda mungkin juga menyukai