SAFE Analysis & Design Report

Model Name: F2.fdb

1 November 2016

F2.fdb
6. Design summary

SAFE 2014 v14.2.0 - License #*1MUUGRSX2HCBNRR


01 November 2016

6. Design summary
This section provides design information for beams, strips, and punching checks.

6.1. Preferences
Table 19: Design Preferences 01 - Resistance Factors
Table 19: Design Preferences 01 Resistance Factors
PhiTen
PhiComp
PhiShear
0.900000

0.650000

0.750000

Table 20: Design Preferences 02 - Rebar Cover - Slabs


CoverTop
m
0.015000

CoverBot
m
0.015000

Table 20: Design Preferences 02 - Rebar Cover - Slabs


BarSize
InnerLayer
PTCGSTop PTCGSBotExt PTCGSBotInt
m
m
m
18
B
0.025000
0.040000
0.025000

SlabType
Two Way

Table 21: Design Preferences 03 - Rebar Cover - Beams


CoverTop
m
0.040000

Table 21: Design Preferences 03 - Rebar Cover - Beams


CoverBot BarSizeF
BarSizeS
PTCGSTop
m
m
0.040000
28
12
0.050000

PTCGSBot
m
0.050000

6.2. Overwrites
Table 23: Slab Design Overwrites 01 - Strip Based
Strip
CSA1
CSB1

Table 23: Slab Design Overwrites 01 - Strip Based


Layer
DesignType
RLLF IgnorePT
A
B

Column
Column

1.000000
1.000000

No
No

RebarMat
CSA-G30.18Gr400
CSA-G30.18Gr400

Table 24: Slab Design Overwrites 02 - Finite Element Based, Part 1 of 2


Table 24: Slab Design Overwrites 02 - Finite Element
Based, Part 1 of 2
Area
RebarMat
LOAD1

CSA-G30.18Gr400

Page 2 of 8

F2.fdb
6. Design summary

SAFE 2014 v14.2.0 - License #*1MUUGRSX2HCBNRR


01 November 2016

FOOTING

CSA-G30.18Gr400

Table 24: Slab Design Overwrites 02 - Finite Element Based, Part 2 of 2


Table 24: Slab Design Overwrites 02 - Finite Element Based,
Part 2 of 2
Area
RLLF
Design
IgnorePT
LOAD1
FOOTING

1.000000
1.000000

Yes
Yes

No
No

Table 25: Punching Shear Design Overwrites 01 - General


Point
9

Table 25: Punching Shear Design Overwrites 01 - General


Check
LocType
EffDepth
ReinfType
Program
Determined

Auto

Auto

None

6.3. Slab design


Table 26: Concrete Slab Design Summary 01 - Flexural And Shear Data, Part 1 of 3
Table 26: Concrete Slab Design Summary 01 - Flexural And Shear Data, Part 1 of 3
Strip
SpanID
Location
FTopCombo
FTopMoment
FTopArea
Tonf-m
m2
CSA1
Span 1
Start
0.00000
0.000000
CSA1
Span 1
Middle
0.00000
0.000000
CSA1
Span 1
End
DCONU1
-0.21970
0.000000
CSB1
Span 1
Start
0.00000
0.000000
CSB1
Span 1
Middle
0.00000
0.000000
CSB1
Span 1
End
DCONU1
-0.06156
0.000000

Table 26: Concrete Slab Design Summary 01 - Flexural And Shear Data, Part 2 of 3
Table 26: Concrete Slab Design Summary 01 - Flexural And Shear Data, Part 2 of 3
Strip
SpanID
Location
FBotCombo
FBotMoment
FBotArea
Tonf-m
m2
CSA1
Span 1
Start
0.00000
0.000000
CSA1
Span 1
Middle
DCONU1
0.65425
0.000037
CSA1
Span 1
End
DCONU1
0.22003
0.000000
CSB1
Span 1
Start
0.00000
0.000000
CSB1
Span 1
Middle
DCONU1
1.43841
0.000086
CSB1
Span 1
End
DCONU1
0.07767
0.000000

Table 26: Concrete Slab Design Summary 01 - Flexural And Shear Data, Part 3 of 3
Strip

Table 26: Concrete Slab Design Summary 01 - Flexural And Shear Data, Part 3 of 3
SpanID
Location
VCombo
VForce
VArea
Status
Tonf
m2/m

Layer

Page 3 of 8

F2.fdb
6. Design summary
CSA1
CSA1
CSA1
CSB1
CSB1
CSB1

Span 1
Span 1
Span 1
Span 1
Span 1
Span 1

SAFE 2014 v14.2.0 - License #*1MUUGRSX2HCBNRR


01 November 2016
Start
Middle
End
Start
Middle
End

DCONU1
DCONU1
DCONU1
DCONU1

0.0000
1.2595
1.2595
0.0000
2.7803
0.2614

0.000000
0.000000
0.000000
0.000000
0.000000
0.000000

OK
OK
OK
OK
OK
OK

A
A
A
B
B
B

Page 4 of 8

F2.fdb
6. Design summary

SAFE 2014 v14.2.0 - License #*1MUUGRSX2HCBNRR


01 November 2016

ACI 318-14 Concrete Strip Design


Material Properties
Geometric Properties
Combination = Overall Envelope
Strip Label = CSA1
Length = 1.5 m
Distance to Top Rebar Center = 0.024 m
Distance to Bot Rebar Center = 0.024 m

Concrete Comp. Strength = 3059.15 Tonf/m2


Concrete Modulus = 2719309.02 Tonf/m2
Longitudinal Rebar Yield = 40788.65 Tonf/m2

ACI 318-14 Concrete Strip Design


Page 5 of 8

F2.fdb
6. Design summary

SAFE 2014 v14.2.0 - License #*1MUUGRSX2HCBNRR


01 November 2016
Material Properties

Geometric Properties
Combination = Overall Envelope
Strip Label = CSB1
Length = 1.5 m
Distance to Top Rebar Center = 0.042 m
Distance to Bot Rebar Center = 0.042 m

Concrete Comp. Strength = 3059.15 Tonf/m2


Concrete Modulus = 2719309.02 Tonf/m2
Longitudinal Rebar Yield = 40788.65 Tonf/m2

Page 6 of 8

F2.fdb
6. Design summary

SAFE 2014 v14.2.0 - License #*1MUUGRSX2HCBNRR


01 November 2016

6.4. Beam design


6.5. Punching check/design
Table 27: Concrete Slab Design 02 - Punching Shear Data, Part 1 of 3
Point
9

Table 27: Concrete Slab Design 02 - Punching Shear Data, Part 1 of 3


GlobalX
GlobalY
Location
Perimeter
Depth
Status
m
m
m
m
0.00000
0.00000
Corner
2.567500
0.467000
OK

Ratio
0.023199

Table 27: Concrete Slab Design 02 - Punching Shear Data, Part 2 of 3


Point
9

Table 27: Concrete Slab Design 02 - Punching Shear Data, Part 2 of 3


Combo
Vu
Gamma_v2
Gamma_v3
ShrStrMax
Tonf
Tonf/m2
DCONU1
-2.7429
0.400000
0.400000
3.23

Mu2
Tonf-m
1.56748

ShrStrCap
Tonf/m2
139.13

Table 27: Concrete Slab Design 02 - Punching Shear Data, Part 3 of 3


Point
9

Table 27: Concrete Slab Design 02 - Punching Shear Data, Part 3 of 3


Mu3 ReinfType
UnbalMu2
UnbalMu3
NumRails
Tonf-m
Tonf-m
Tonf-m
0.00652
None
0.62699
0.00261

ACI 318-14 Punching Shear Check


& Design
Geometric Properties
Combination = 0
Point Label = 9
Column Shape = Rectangular
Column Location = Corner
Global X-Coordinate = 0 m
Global Y-Coordinate = 0 m

StudPerRail

Section Inertia I22 = 0.21673 m4


Section Inertia I33 = 0.21673 m4
Section Inertia I23 = 0 m4
Gamma_v2 = 0.4
Gamma_v3 = 0.4
Moment Mu2 = 1.56748 Tonf-m
Moment Mu3= 0.00652 Tonf-m
Shear Force = -2.7429 Tonf
Unbalanced Moment Mu2 = 0.62699 Tonf-m

Load Punching Check


Avg. Eff. Slab Thickness = 0.467 m
Eff. Punching Perimeter = 2.5675 m
Cover = 0.033 m
Conc. Comp. Strength = 3059.15 Tonf/m2
Reinforcement Ratio = 0.0000

Page 7 of 8

F2.fdb
6. Design summary

SAFE 2014 v14.2.0 - License #*1MUUGRSX2HCBNRR


01 November 2016
Column Punching Perimeter

Page 8 of 8