Anda di halaman 1dari 63

C0002-06_GEN06

2006

Air conditioning solutions

Residential and Light Commercial Systems

SOLUTIONS FOR A FRESHER WORLD

INDEX

INVERTER SPEED SYSTEMS


42PQV_S

42HQV

42PQV_lc

42VQV

40KQV

40DQV

38VYX

38VGM

18 - 19

20 - 21

22 - 23

24 - 25

26 - 27

28 - 29

30 - 31

32 - 33

FIXED SPEED SYSTEM


42PHQ_S

42PHQ_A

42VMC_N

40KMC_N

40SMC_N

40DMC

FB4X

38GLM/YYM

34 - 35

36 - 37

38 - 39

40 - 41

42 - 43

44 - 45

46 - 47

48 - 53

DX CONTROLS
DX CONTROLS

54 - 55

FIXED SPEED SYSTEM


42HQE

56 - 57

ROOM AIR CONDITIONERS


73FC/XC/YC

51AKA/B/C

51AKS

54DHS

58 - 59

60 - 61

62 - 63

64 - 65

Our mission is to make he world a better place to live. A

For our commitment in developing products for a safer,

mission that was born more than one hundred years ago

cleaner and less polluted planet we received the presti-

when Willis Carrier invented the basics of modern air con-

gious

ditioning and developed the first air conditioning system.

Environmental Protection Agency (EPA). Every day around

Since then we have created a confortable, productive and

the world a Carrier system is installed every eight

healthy environment, regardless of climate, and we have

seconds, and we are now the worlds largest manufacturer

ensured that the global food supply is transported and

of air conditioning, ventilation, heating and commercial

preserved for safe consumption.

refrigeration system.

Our dedication to enhance our environment also means


preserving the environment for everybody.
Carrier was the first air conditioning manufacturer to use
chlorine-free refrigerants that do not deplete the ozone
layer.

SOLUTIONS FOR A FRESHER WORLD

Ozone

Protection

Award

from

the

U.S.

Carrier is a member of the United Technologies Corporation


(UTC) which employs 205,700 people, operates in more than
180 countries, and is the 51st largest corporation in the
United States. The UTC group is a global technology corporation with a long history of a pioneering innovation in aerospace, aviaton, helicopter design, climate control, elevator
design and hydrogen fuel cells.
Supported by leadership of UTC, Carrier is a source of ideas,
technologies and innovation to help buid a better world.

CARRIER EXPE RIENCE BACKED BY A LARGE GROUP

The world's largest manu-

The experts in electronic

The world's largest manu-

The innovators in hydro-

facturer of air conditio-

security systems, fire pro-

facturer

gen-powered fuel cells for

ning, ventilation and refri-

tection systems and secu-

escalators

geration systems

rity system monitoring

walkways

of

elevators,

and

moving

space, commercial transport

and

applications.

The leading supplier

The specialists in com-

The world leader inthe

of aerospace systemsand

mercial and military air-

design and manufacture of

components, fueand spe-

craft engines and space

helicopters for commer-

cial fluid pumps, and pro-

propulsion systems

cial, industrial and milita-

pellerand engine control


systems

ry use.

residential

Carrier is a member of the United Technologies Corporation


(UTC) which employs 205,700 people, operates in more than
180 countries, and is the 51st largest corporation in the
United States. The UTC group is a global technology corporation with a long history of a pioneering innovation in aerospace, aviaton, helicopter design, climate control, elevator
design and hydrogen fuel cells.
Supported by leadership of UTC, Carrier is a source of ideas,
technologies and innovation to help buid a better world.

CARRIER EXPE RIENCE BACKED BY A LARGE GROUP

The world's largest manu-

The experts in electronic

The world's largest manu-

The innovators in hydro-

facturer of air conditio-

security systems, fire pro-

facturer

gen-powered fuel cells for

ning, ventilation and refri-

tection systems and secu-

escalators

geration systems

rity system monitoring

walkways

of

elevators,

and

moving

space, commercial transport

and

applications.

The leading supplier

The specialists in com-

The world leader inthe

of aerospace systemsand

mercial and military air-

design and manufacture of

components, fueand spe-

craft engines and space

helicopters for commer-

cial fluid pumps, and pro-

propulsion systems

cial, industrial and milita-

pellerand engine control


systems

ry use.

residential

Michelangelo's frescos, the Alexandrian manuscripts and the


works of art in the British Museum can be admired thanks to
Carrier. Carrier air and climate quality control systems are
chosen to protect the most prestigious buildings in the
world, supported by the know-how and expertise of a company with over 100 years of experience and continuous innovation. The Carrier brand is renowned as a reliable partner
for any application.

YOUR PARTNER FOR GREAT CHALLENGES

Alexandria Library

Suntek City Singapore

Carrier has supplied the climate control system that protects

New British Museum London

The world biggest telescope.


Cerro La Silla - Chile

and monitors the Sistine Chapel 24 hours a day.

Queen Mary II

Epcot Center Florida

Michelangelo's frescos, the Alexandrian manuscripts and the


works of art in the British Museum can be admired thanks to
Carrier. Carrier air and climate quality control systems are
chosen to protect the most prestigious buildings in the
world, supported by the know-how and expertise of a company with over 100 years of experience and continuous innovation. The Carrier brand is renowned as a reliable partner
for any application.

YOUR PARTNER FOR GREAT CHALLENGES

Alexandria Library

Suntek City Singapore

Carrier has supplied the climate control system that protects

New British Museum London

The world biggest telescope.


Cerro La Silla - Chile

and monitors the Sistine Chapel 24 hours a day.

Queen Mary II

Epcot Center Florida

Carrier is the largest organisation world-wide committed to


development and research in air conditioning. A great innovative force that continuously sets new standards in comfort,
efficiency and installation flexibility. Satellite, the innovatiSatellite detail V-shaped coil

ve Carrier ductable system that has completely revolutionised previous market standards, that were of course also set
by Carrier. Designed together by the best professionals, and
destined to become the absolute new industry standard.

RESEARCH + EXPE RIENCE = INNOVATIVE SOLUTION

The technical experts unveil a new standard of working - simple,

clean, flexible, efficient - leaving customers completely satisfied

Carrier is the largest organisation world-wide committed to


development and research in air conditioning. A great innovative force that continuously sets new standards in comfort,
efficiency and installation flexibility. Satellite, the innovatiSatellite detail V-shaped coil

ve Carrier ductable system that has completely revolutionised previous market standards, that were of course also set
by Carrier. Designed together by the best professionals, and
destined to become the absolute new industry standard.

RESEARCH + EXPE RIENCE = INNOVATIVE SOLUTION

The technical experts unveil a new standard of working - simple,

clean, flexible, efficient - leaving customers completely satisfied

The air quality in closed rooms can be 10 times more polluted than the outdoor air. To offer more breathable air,
Carrier has developed Air4Life, an efficient four-stage air
filtration system, based on titanium-dioxide technology to
make the air cleaner and healthier. To recreate the same
pleasant sensation of well-being that exists near a waterfall or in a forest in your own home, Carrier air conditioners include ionisers, to make the air more pleasant and
healthier to breathe.

HEALTHY AIR FOR ENHANCED WELL-BEING

The exclusive four-stage Air4Life filtration system makes the

The same pleasant sensation of well-being that can be

Negative ions assist the elimination of serotonin from the

air healthier and cleaner, significantly reducing pollutants,

found in a forest or in the mountains can now be achieved

blood, providing vigour and energy and increasing concen-

pollen and

in your own home with the Carrier ioniser. It enriches the

tration. With their relaxing effect they are a valuable aid

air with negative ions to provide vitality and energy.

against daily stress.

allergens.

The air quality in closed rooms can be 10 times more polluted than the outdoor air. To offer more breathable air,
Carrier has developed Air4Life, an efficient four-stage air
filtration system, based on titanium-dioxide technology to
make the air cleaner and healthier. To recreate the same
pleasant sensation of well-being that exists near a waterfall or in a forest in your own home, Carrier air conditioners include ionisers, to make the air more pleasant and
healthier to breathe.

HEALTHY AIR FOR ENHANCED WELL-BEING

The exclusive four-stage Air4Life filtration system makes the

The same pleasant sensation of well-being that can be

Negative ions assist the elimination of serotonin from the

air healthier and cleaner, significantly reducing pollutants,

found in a forest or in the mountains can now be achieved

blood, providing vigour and energy and increasing concen-

pollen and

in your own home with the Carrier ioniser. It enriches the

tration. With their relaxing effect they are a valuable aid

air with negative ions to provide vitality and energy.

against daily stress.

allergens.

Carrier quality and reliability are incorporated and


guaranteed in all products and systems. They are submitted
to extensive tests before they are shipped to the customers,
such as a 10-minute system operating test. They are also
certified by the major international organisations to guarantee authenticity of the information supplied, safety of the
products and high process applications standards. All this
means that the customer will receive a safe and reliable
product.

RELIABILITY

INCLUDED

Performance Eurovent guarantee

Safety for the customer

ISO 9001:2000 process certification

Carrier has participated in the Eurovent certification program-

In addition to the CE marking, the absolute safety of

All Carrier processes are certified in accordance

me from the very beginning. Eurovent tests the products and

Carrier products is certified and guaranteed by the presti-

with the quality management system standard ISO

verifies the conformance between test results and product.

gious independent performance data published by the

9001:2000 to assure the customer that products

manufacturer.

and services conform with the policies of the Carrier


organisation
organisations.

IMQ

agency

or

other

equivalent

Carrier quality and reliability are incorporated and


guaranteed in all products and systems. They are submitted
to extensive tests before they are shipped to the customers,
such as a 10-minute system operating test. They are also
certified by the major international organisations to guarantee authenticity of the information supplied, safety of the
products and high process applications standards. All this
means that the customer will receive a safe and reliable
product.

RELIABILITY

INCLUDED

Performance Eurovent guarantee

Safety for the customer

ISO 9001:2000 process certification

Carrier has participated in the Eurovent certification program-

In addition to the CE marking, the absolute safety of

All Carrier processes are certified in accordance

me from the very beginning. Eurovent tests the products and

Carrier products is certified and guaranteed by the presti-

with the quality management system standard ISO

verifies the conformance between test results and product.

gious independent performance data published by the

9001:2000 to assure the customer that products

manufacturer.

and services conform with the policies of the Carrier


organisation
organisations.

IMQ

agency

or

other

equivalent

Today potential and existing residential and light commercial


air conditioning customers are very demanding. They have
many differing expectations and varying profiles. The Carrier
product range will provide them all with the ideal solution for
their individual functional, aesthetic and economical requirements and their personal preference. They will all have the
peaceof-mind of having chosen the world's leading industry
expert. Carrier has a differentiated product range that also
benefits our partners who can now personalise their offer for
their own customer base.

PERSONALIZED

Absolute well-being

AIR CONDITIONING

Superior comfort

Comfort at close hand

Today potential and existing residential and light commercial


air conditioning customers are very demanding. They have
many differing expectations and varying profiles. The Carrier
product range will provide them all with the ideal solution for
their individual functional, aesthetic and economical requirements and their personal preference. They will all have the
peaceof-mind of having chosen the world's leading industry
expert. Carrier has a differentiated product range that also
benefits our partners who can now personalise their offer for
their own customer base.

PERSONALIZED

Absolute well-being

AIR CONDITIONING

Superior comfort

Comfort at close hand

42PQV_S - HI-WALL UNIT


INVERTER SPLIT SYSTEM

Indoor unit

42PQV009S

42PQV012S

Outdoor unit (HP)

38VBH009S

38VBH012S

Nominal cooling capacity

kW

2,60

3,50

Minimum cooling capacity

kW

1,40

1,80

Maximum cooling capacity

kW

3,30

4,00

Nominal power input

810

1163

Minimum power input

420

537

Maximum power input

1467

1818

W/W

3,21

3,01

EER
Energy efficiency class (CO)

Annual energy consumption

kWh

405

582

Nominal heating capacity

kW

3,20

4,00

Minimum heating capacity

kW

1,50

1,90

Maximum heating capacity

kW

4,0

5,1

Nominal power input

928

1246

Minimum power input

395

506

Maximum power input

1550

2100

W/W

3,45

3,21

COP
Energy efficiency class (HP)
Indoor unit
Dehumidification
Air flow (l/m/h)

09

12

l/h

1,1

1,3

l/s

114/135/155

124/141/161

Sound pressure (l/m/h)

dB(A)*

33/36/39

35/37/40

Sound power (l/m/h)

dB(A)

46/49/52

48/50/53

Dimensions (HxLxD)

mm

260x790x196

260x790x196

Weight

kg

8,6

8,6

V-ph-Hz

220/240-1-50/60

220/240-1-50/60

Power Supply
Outdoor unit (HP)

09

12

Compressor Type

rotary

rotary

Maximum pipe length

10

15

Maximum height difference

10

Chargeless pipe length


Air flow
Sound pressure
Sound power

10

15

m3/h

605 - 1690

580 - 1550

dB(A)**

41

41

dB(A)

61

61

Dimensions (HxLxD)

mm

590 x 750 x 280

590 x 750 x 280

Weight

kg

33

37

inch

3/8 - 1/4

1/2 - 1/4

11

V-ph-Hz

220/240-1-50/60

220/240-1-50/60

Flare Connections
Starting current
Power Supply
*
**

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4m.

42PQV_S INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 40PQV_S

42PQV_S Inverter hi-wall

Class A efficiency - the ultimate evolution of


comfort with maximised savings thanks to the
XPower inverter technology.

42PQV_S - HI-WALL UNIT


The elegant slim-line XPower Sensat-ion will create a feeling of optimal
well-being and vitality and blend with any room decoration.

CONTROLS

2 sizes in cooling only and heat pump capacities from: 2,6kW to 3,5kW in cooling; 3,2kW
to 4,0kW in heating.

FEATURES
Extra Power, Ionizer and Eco function

A perfect combination of ions and micro-filtered air. This way the air in your
home is always clean and energised.
The start-up speed of the XPower system provides you with maximum comfort
in half the time compared to traditional systems.
Constant comfort. As the temperature approaches the preset level, XPower
gradually reduces the compressor speed.
All Sensat-ion models are in Satin finish aluminium, high quality and un-matched style.

ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter.

EXCLUSIVE 4 STAGE FILTRATION SYSTEM. 1.anti-bacteria pre filter; 2.electrostatic filter; 3.photo catalyst re-generable filter;4.anti-bacteria fan and drain
pan.
Thanks to the new air management system and to the Inverter technology the
noise is reduced to a whisper.

OUTDOOR UNITS

ANTI CORROSION PROTECTION. Plastic case condensing unit; compact and


light. UV light resistant.

Monosplit: 38VBH_S

18

19

42PQV_S - HI-WALL UNIT


INVERTER SPLIT SYSTEM

Indoor unit

42PQV009S

42PQV012S

Outdoor unit (HP)

38VBH009S

38VBH012S

Nominal cooling capacity

kW

2,60

3,50

Minimum cooling capacity

kW

1,40

1,80

Maximum cooling capacity

kW

3,30

4,00

Nominal power input

810

1163

Minimum power input

420

537

Maximum power input

1467

1818

W/W

3,21

3,01

EER
Energy efficiency class (CO)

Annual energy consumption

kWh

405

582

Nominal heating capacity

kW

3,20

4,00

Minimum heating capacity

kW

1,50

1,90

Maximum heating capacity

kW

4,0

5,1

Nominal power input

928

1246

Minimum power input

395

506

Maximum power input

1550

2100

W/W

3,45

3,21

COP
Energy efficiency class (HP)
Indoor unit
Dehumidification
Air flow (l/m/h)

09

12

l/h

1,1

1,3

l/s

114/135/155

124/141/161

Sound pressure (l/m/h)

dB(A)*

33/36/39

35/37/40

Sound power (l/m/h)

dB(A)

46/49/52

48/50/53

Dimensions (HxLxD)

mm

260x790x196

260x790x196

Weight

kg

8,6

8,6

V-ph-Hz

220/240-1-50/60

220/240-1-50/60

Power Supply
Outdoor unit (HP)

09

12

Compressor Type

rotary

rotary

Maximum pipe length

10

15

Maximum height difference

10

Chargeless pipe length


Air flow
Sound pressure
Sound power

10

15

m3/h

605 - 1690

580 - 1550

dB(A)**

41

41

dB(A)

61

61

Dimensions (HxLxD)

mm

590 x 750 x 280

590 x 750 x 280

Weight

kg

33

37

inch

3/8 - 1/4

1/2 - 1/4

11

V-ph-Hz

220/240-1-50/60

220/240-1-50/60

Flare Connections
Starting current
Power Supply
*
**

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4m.

42PQV_S INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 40PQV_S

42PQV_S Inverter hi-wall

Class A efficiency - the ultimate evolution of


comfort with maximised savings thanks to the
XPower inverter technology.

42PQV_S - HI-WALL UNIT


The elegant slim-line XPower Sensat-ion will create a feeling of optimal
well-being and vitality and blend with any room decoration.

CONTROLS

2 sizes in cooling only and heat pump capacities from: 2,6kW to 3,5kW in cooling; 3,2kW
to 4,0kW in heating.

FEATURES
Extra Power, Ionizer and Eco function

A perfect combination of ions and micro-filtered air. This way the air in your
home is always clean and energised.
The start-up speed of the XPower system provides you with maximum comfort
in half the time compared to traditional systems.
Constant comfort. As the temperature approaches the preset level, XPower
gradually reduces the compressor speed.
All Sensat-ion models are in Satin finish aluminium, high quality and un-matched style.

ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter.

EXCLUSIVE 4 STAGE FILTRATION SYSTEM. 1.anti-bacteria pre filter; 2.electrostatic filter; 3.photo catalyst re-generable filter;4.anti-bacteria fan and drain
pan.
Thanks to the new air management system and to the Inverter technology the
noise is reduced to a whisper.

OUTDOOR UNITS

ANTI CORROSION PROTECTION. Plastic case condensing unit; compact and


light. UV light resistant.

Monosplit: 38VBH_S

18

19

42HQV_R - HI-WALL UNITS


INVERTER SPLIT SYSTEM

Indoor unit

42HQV025R

42HQV035R

42HQV045R

Outdoor unit HP

38VYX025R

38VYX035R

38VYX045R

Nominal cooling capacity

kW

2,50

3,50

4,62

Minimum cooling capacity

kW

0,90

1,10

1,20

Maximum cooling capacity

kW

3,00

4,00

5,10

Nominal power input

780

1090

1630

Minimum power input

260

200

260

Maximum power input

990

1330

1930

3,21

3,21

2,83

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

390

545

815

Nominal heating capacity

kW

3,20

4,20

5,90

Minimum heating capacity

kW

0,90

1,10

1,30

Maximum heating capacity

kW

4,00

5,80

7,40

Nominal power input

870

1150

1760

Minimum power input

210

200

270

Maximum power input

1160

1670

2360

3,68

3,65

3,35

COP
Energy efficiency class (HP)
Indoor unit
Deumidification
Air flow (l/m/h)

25

35

45

l/h

1,5

2,0

2,1

l/s

95/125/147

95/125/147

145/179/212

Sound pressure level (l/m/h)

dB(A)*

29/35/39

28/34/39

34/40/45

Sound power level (l/m/h)

dB(A)

42/48/52

41/47/52

47/53/58

Dimensions (H x L x D)

mm

275 x 790 x 208

275 x 790 x 208

275 x 790 x 208

Weight

kg

10

10

10

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

25

35

45

Maximum pipe length

10

15

15

Vertical height difference

Power Supply
Outdoor unit (HP)

10

10

Rotary

Rotary

Twin Rrotary

10

15

15

dB(A)**

40

43

44

Compressor Type
Chargeless
Sound pressure level (l/m/h)
Sound power level (l/m/h)

dB(A)

60

63

64

Dimensions (H x L x D)

mm

530 x 660 x 240

550 x 780 x 270

550 x 780 x 270

Weight

kg

30

36

39

Flare Connections
Power Supply
*
**

inch

3/8" - 1/4"

3/8" - 1/4"

1/2" - 1/4"

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

Sound Pressure level at 1,5m distance from indoor unit.


Sound Pressure level at 1m distance from outdoor unit.

The Nano Technology


Nano technology increases the filtering capacity, improving the performance of the filters, by reducing the normal filter components size
into nano-size or crystal forms. This process makes Nano filters more effective than standard ones.

42HQV_R INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 42HQV_R

42HQV_R DC Inverter Hi-wall

A efficiency class in cooling and heating thanks


to the advanced XPower DC Inverter technology.

42HQV_R - HIGH-WALL
SilenTECH is the ultimate evolution of comfort with its low noise level and
its maximum energy savings.
3 sizes heat pump; capacities from 2,5kW to 4,62kW in cooling and from 3,2 kW to 5,9
kW in heating.

FEATURES
The new XPower DC Inverter technology allows to reach quickly the optimal
well-being with the maximum energy savings.

Unique combined action of PAM and PWM


control.

CONTROLS

Exclusive air purification system: the new Nano-Photo Copper and the new
Nano-Silver-Gingsen filters are the most powerful solution to eliminate bacteria
and deodorize the air.
Thanks to the XPower DC Inverter technology the sound is light like a feather.
The start-up speed of the XPower system provides the maximum comfort in
half the time compared to a traditional system.
Unique combined action of PAM & PWM controls:
- PAM (Pulse Amplitude Modulation) generates maximum power at start-up
- PWM (Pulse Width Modulation) optimises the efficiency once the ideal tem
perature has been reached.

Extra power & Eco function

OUTDOOR UNITS

The ancient benefits of Gingseng


Ginseng is known to lower cholesterol, to balance the metabolism, to increase energy levels, and to stimulate the immune system.
It is also used to alleviate fatigue and to reduce stress on the body. It increases cells and tissues oxygenation, promoting detoxification and stimulating the regeneration of damaged cells.
Monosplit: 38VYX_R

20

21

42HQV_R - HI-WALL UNITS


INVERTER SPLIT SYSTEM

Indoor unit

42HQV025R

42HQV035R

42HQV045R

Outdoor unit HP

38VYX025R

38VYX035R

38VYX045R

Nominal cooling capacity

kW

2,50

3,50

4,62

Minimum cooling capacity

kW

0,90

1,10

1,20

Maximum cooling capacity

kW

3,00

4,00

5,10

Nominal power input

780

1090

1630

Minimum power input

260

200

260

Maximum power input

990

1330

1930

3,21

3,21

2,83

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

390

545

815

Nominal heating capacity

kW

3,20

4,20

5,90

Minimum heating capacity

kW

0,90

1,10

1,30

Maximum heating capacity

kW

4,00

5,80

7,40

Nominal power input

870

1150

1760

Minimum power input

210

200

270

Maximum power input

1160

1670

2360

3,68

3,65

3,35

COP
Energy efficiency class (HP)
Indoor unit
Deumidification
Air flow (l/m/h)

25

35

45

l/h

1,5

2,0

2,1

l/s

95/125/147

95/125/147

145/179/212

Sound pressure level (l/m/h)

dB(A)*

29/35/39

28/34/39

34/40/45

Sound power level (l/m/h)

dB(A)

42/48/52

41/47/52

47/53/58

Dimensions (H x L x D)

mm

275 x 790 x 208

275 x 790 x 208

275 x 790 x 208

Weight

kg

10

10

10

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

25

35

45

Maximum pipe length

10

15

15

Vertical height difference

Power Supply
Outdoor unit (HP)

10

10

Rotary

Rotary

Twin Rrotary

10

15

15

dB(A)**

40

43

44

Compressor Type
Chargeless
Sound pressure level (l/m/h)
Sound power level (l/m/h)

dB(A)

60

63

64

Dimensions (H x L x D)

mm

530 x 660 x 240

550 x 780 x 270

550 x 780 x 270

Weight

kg

30

36

39

Flare Connections
Power Supply
*
**

inch

3/8" - 1/4"

3/8" - 1/4"

1/2" - 1/4"

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

Sound Pressure level at 1,5m distance from indoor unit.


Sound Pressure level at 1m distance from outdoor unit.

The Nano Technology


Nano technology increases the filtering capacity, improving the performance of the filters, by reducing the normal filter components size
into nano-size or crystal forms. This process makes Nano filters more effective than standard ones.

42HQV_R INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 42HQV_R

42HQV_R DC Inverter Hi-wall

A efficiency class in cooling and heating thanks


to the advanced XPower DC Inverter technology.

42HQV_R - HIGH-WALL
SilenTECH is the ultimate evolution of comfort with its low noise level and
its maximum energy savings.
3 sizes heat pump; capacities from 2,5kW to 4,62kW in cooling and from 3,2 kW to 5,9
kW in heating.

FEATURES
The new XPower DC Inverter technology allows to reach quickly the optimal
well-being with the maximum energy savings.

Unique combined action of PAM and PWM


control.

CONTROLS

Exclusive air purification system: the new Nano-Photo Copper and the new
Nano-Silver-Gingsen filters are the most powerful solution to eliminate bacteria
and deodorize the air.
Thanks to the XPower DC Inverter technology the sound is light like a feather.
The start-up speed of the XPower system provides the maximum comfort in
half the time compared to a traditional system.
Unique combined action of PAM & PWM controls:
- PAM (Pulse Amplitude Modulation) generates maximum power at start-up
- PWM (Pulse Width Modulation) optimises the efficiency once the ideal tem
perature has been reached.

Extra power & Eco function

OUTDOOR UNITS

The ancient benefits of Gingseng


Ginseng is known to lower cholesterol, to balance the metabolism, to increase energy levels, and to stimulate the immune system.
It is also used to alleviate fatigue and to reduce stress on the body. It increases cells and tissues oxygenation, promoting detoxification and stimulating the regeneration of damaged cells.
Monosplit: 38VYX_R

20

21

42PQV_S LC - HI-WALL UNIT


INVERTER SPLIT SYSTEM

Indoor unit

42PQV050S

42PQV080S

42PQV110S

Outdoor unit HP

38VYX050N

38VYX080N

38VYX110N
9,20

Nominal cooling capacity

kW

4,80

6,50

Minimum cooling capacity

kW

1,00

2,10

2,20

Maximum cooling capacity

kW

5,25

7,00

11,00

1780

2490

3333

W/W

2,70

2,61

2,76

kW

890

1245

1667

Nominal power input


EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%

W/W (1)

4,30

4,20

4,80

Nominal heating capacity

kW

5,25

7,60

10,10

Minimum heating capacity

kW

0,90

1,70

2,20

Maximum heating capacity

kW

6,50

7,94

12,5

Nominal power input

1540

2750

2962

W/W

3,41

2,76

3,41

5,20

4,00

5,10

050

080

110

COP
Energy efficiency class (HP)
COP 50%

W/W (1)

Indoor unit
Deumidification

l/h

1,8

2,0

2,1

Nominal air flow (low/med/high)

l/s

160/200/230

95/125/147

145/179/212

Sound pressure (low/med/high) (CO)

dB(A)*

36/40/43

28/34/39

34/40/45

Sound power (low/med/high) (CO)

dB(A)

49/53/56

41/47/52

47/53/58

Sound pressure (low/med/high) (HP)

dB(A)*

34/38/41

275 x 790 x 208

275 x 790 x 208

Sound power (low/med/high) (HP)

dB(A)

47/51/54

10

10

Dimensions (H x L x D)

mm

285x1080x200

285x1080x200

446x546x356

Weight

kg

14

14

23

V-Ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

Power supply
Outdoor unit (HP)

050

080

110

Compressor Type

Twin Rotary

Twin Rotary

Twin Rotary

Maximum pipe lenght

30

50

50

Maximum height difference

30

30 (15)

30 (15)

Chargeless pipe lenght

20

20

20

m3/h

290/665

290/110

nd/2085

dB(A)**

43

45

51

Air Flow (Min/Max)


Sound pressure (CO)
Sound power (CO)

dB(A)

63

65

71

dB(A)**

45

47

51

dB(A)

65

67

71

Dimensions (H x L x D)

mm

595x780x270

795x900x320

1340x900x320

Weight

kg

35

55

75

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

Sound pressure (HP)


Sound power (HP)

Flare connections
Starting current
Power supply

12

15

22

V-Ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity

42PQV_S LC INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 40PQV_S LC

42PQV_S LC - HI-WALL UNIT

DC Blended Inverter Technology: more comfort


and effective cost savings.

42PQV_S LC - HI-WALL UNIT


Xpower Sensation light commercial high-wall indoor unit offers optimised
comfort with an excellent seasonal energy efficiency ratio. In addition
Air4Life and the ionizer provide superior indoor air quality.

CONTROLS

3 sizes in cooling only and heat pump capacities from: 1,7 kW to 11 kW in cooling; 1,5
kW to 11,5 kW in heating.

FEATURES
Extra Power, Ionizer and Eco function

Customised air distribution - six different air flow positions and exclusive Twin
Swing air distribution function.
Stable indoor comfort and extremely low room temperature fluctuation.
Continuous low-speed operation and compressor sound blankets ensure
exceptionally low noise levels for superior acoustic comfort.
Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.

ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter.

Powerful dehumidification ensures humidity level control during all seasons.


A perfect combination of ionised and micro-filtered air for a clean and healthy
indoor environment.

OUTDOOR UNITS

monosplit 38VYX_N

22

23

42PQV_S LC - HI-WALL UNIT


INVERTER SPLIT SYSTEM

Indoor unit

42PQV050S

42PQV080S

42PQV110S

Outdoor unit HP

38VYX050N

38VYX080N

38VYX110N
9,20

Nominal cooling capacity

kW

4,80

6,50

Minimum cooling capacity

kW

1,00

2,10

2,20

Maximum cooling capacity

kW

5,25

7,00

11,00

1780

2490

3333

W/W

2,70

2,61

2,76

kW

890

1245

1667

Nominal power input


EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%

W/W (1)

4,30

4,20

4,80

Nominal heating capacity

kW

5,25

7,60

10,10

Minimum heating capacity

kW

0,90

1,70

2,20

Maximum heating capacity

kW

6,50

7,94

12,5

Nominal power input

1540

2750

2962

W/W

3,41

2,76

3,41

5,20

4,00

5,10

050

080

110

COP
Energy efficiency class (HP)
COP 50%

W/W (1)

Indoor unit
Deumidification

l/h

1,8

2,0

2,1

Nominal air flow (low/med/high)

l/s

160/200/230

95/125/147

145/179/212

Sound pressure (low/med/high) (CO)

dB(A)*

36/40/43

28/34/39

34/40/45

Sound power (low/med/high) (CO)

dB(A)

49/53/56

41/47/52

47/53/58

Sound pressure (low/med/high) (HP)

dB(A)*

34/38/41

275 x 790 x 208

275 x 790 x 208

Sound power (low/med/high) (HP)

dB(A)

47/51/54

10

10

Dimensions (H x L x D)

mm

285x1080x200

285x1080x200

446x546x356

Weight

kg

14

14

23

V-Ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

Power supply
Outdoor unit (HP)

050

080

110

Compressor Type

Twin Rotary

Twin Rotary

Twin Rotary

Maximum pipe lenght

30

50

50

Maximum height difference

30

30 (15)

30 (15)

Chargeless pipe lenght

20

20

20

m3/h

290/665

290/110

nd/2085

dB(A)**

43

45

51

Air Flow (Min/Max)


Sound pressure (CO)
Sound power (CO)

dB(A)

63

65

71

dB(A)**

45

47

51

dB(A)

65

67

71

Dimensions (H x L x D)

mm

595x780x270

795x900x320

1340x900x320

Weight

kg

35

55

75

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

Sound pressure (HP)


Sound power (HP)

Flare connections
Starting current
Power supply

12

15

22

V-Ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity

42PQV_S LC INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 40PQV_S LC

42PQV_S LC - HI-WALL UNIT

DC Blended Inverter Technology: more comfort


and effective cost savings.

42PQV_S LC - HI-WALL UNIT


Xpower Sensation light commercial high-wall indoor unit offers optimised
comfort with an excellent seasonal energy efficiency ratio. In addition
Air4Life and the ionizer provide superior indoor air quality.

CONTROLS

3 sizes in cooling only and heat pump capacities from: 1,7 kW to 11 kW in cooling; 1,5
kW to 11,5 kW in heating.

FEATURES
Extra Power, Ionizer and Eco function

Customised air distribution - six different air flow positions and exclusive Twin
Swing air distribution function.
Stable indoor comfort and extremely low room temperature fluctuation.
Continuous low-speed operation and compressor sound blankets ensure
exceptionally low noise levels for superior acoustic comfort.
Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.

ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter.

Powerful dehumidification ensures humidity level control during all seasons.


A perfect combination of ionised and micro-filtered air for a clean and healthy
indoor environment.

OUTDOOR UNITS

monosplit 38VYX_N

22

23

42VQV - CONSOLE UNIT


INVERTER SPLIT SYSTEM

Indoor unit

42VQV0050

42VQV080

42VQV110

42VQV130

Outdoor unit (HP)

38VYX050N

38VYX080N

42VYX080N

42VYX080N
11,72

Nominal cooling capacity

kW

4,85

6,5

9,10

Minimum cooling capacity

kW

1,5

2,1

2,20

3,00

Maximum cooling capacity

kW

5,25

7,2

11,00

13,00

1780

2430

3480

4160

W/W

2,72

2,67

2,61

2,70

890

1215

1740

2080

Nominal power input


EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%

kWh
W/W (1)

3,9

4,2

4,80

4,30

Nominal heating capacity

kW

5,19

7,32

9,60

12,36

Minimum heating capacity

kW

1,5

2,2

2,20

3,00

Maximum heating capacity

kW

7,94

12,50

15,00

1770

2600

2990

4530

W/W

2,93

2,82

3,21

2,70

4,4

4,5

4,50

4,40

50

80

110

130

Nominal power input


COP
Energy efficiency class (HP)
COP 50%

W/W (1)

Indoor unit
Dehumidification

l/h

1,7

2,7

nd

nd

Air flow (l/m/h)

l/s

150/170/205

165/195/220

265/300/330

380/405/445

Sound pressure (CO)

dB(A)*

38/41/45

41/44/49

47/50/52

47/49/51

Sound power (CO)

dB(A)

49/52/56

52/55/60

58/61/63

58/60/62

Sound pressure (HP)

dB(A)*

38/41/45

41/44/49

44/50/52

47/49/51

Sound power (HP)

dB(A)

49/52/56

52/55/60

58/61/63

58/60/62

Dimensions (HxLxD)

mm

598x1000x200

598x1000x200

625x1200x232

625x1200x232

Weight

kg

18

20

27

38

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

220/240-1-50

Power Supply
Outdoor unit (HP)

50

80

110

130

Compressor Type

Twin rotary

Twin rotary

Twin rotary

Twin rotary

Maximum pipe length

30

50

50

50

Maximum height difference

30

30

30

30

Chargeless pipe length

20

20

20

20

m3/h

290/665

290/1110

nd/1890

nd/2085

dB(A)**

43

45

51

51

dB(A)

63

65

71

71

dB(A)**

45

47

51

51

dB(A)

65

67

71

71

Dimensions (HxLxD)

mm

595x780x270

795x900x320

795x900x320

795x900x320

Weight

kg

Air flow (Min/Max)


Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)

35

55

75

85

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

12

15

22

23

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

Flare Connections
Starting current
Power Supply

220/240-1-50
SIZE 30 PRELIMINARY DATA

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity

42VQV INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 42VQV

42VQV - CONSOLE UNIT

Fits under a window sill. Reduced footprint and


compact overall dimensions for a wide choice
of installation solutions.

42VQV - CONSOLE UNIT


The XPower 42VQV console units provide optimised comfort levels with an
excellent seasonal energy efficiency ratio. They are slim and stylish and
designed for installation on a wall or under the ceiling.

CONTROLS

2 sizes in cooling only and heat pump capacities from: 1,5kW to 7,2kW in cooling; 1,5kW
to 7,94kW in heating.

FEATURES
Award from the Italian Association of Industrial Design (ADI).
Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 5m. Filter can be washed and regenerated in sunlight.
Motorised louvre allows air distribution direction according to individual preferences.
MyComfort remote control function memorises the preferred user settings.
State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet.

Freedom of choice between infrared remote


control and wired controls.

ACCESSORIES
Condensate discharge pump.
Piping cover kit.

Fits under a window sill. Reduced footprint and compact overall dimensions for
a wide choice of installation solutions.
All key components are easily accessible through the grille without removing
the front panel.

OUTDOOR UNITS

Monosplit: 38VYX_N

24

25

42VQV - CONSOLE UNIT


INVERTER SPLIT SYSTEM

Indoor unit

42VQV0050

42VQV080

42VQV110

42VQV130

Outdoor unit (HP)

38VYX050N

38VYX080N

42VYX080N

42VYX080N
11,72

Nominal cooling capacity

kW

4,85

6,5

9,10

Minimum cooling capacity

kW

1,5

2,1

2,20

3,00

Maximum cooling capacity

kW

5,25

7,2

11,00

13,00

1780

2430

3480

4160

W/W

2,72

2,67

2,61

2,70

890

1215

1740

2080

Nominal power input


EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%

kWh
W/W (1)

3,9

4,2

4,80

4,30

Nominal heating capacity

kW

5,19

7,32

9,60

12,36

Minimum heating capacity

kW

1,5

2,2

2,20

3,00

Maximum heating capacity

kW

7,94

12,50

15,00

1770

2600

2990

4530

W/W

2,93

2,82

3,21

2,70

4,4

4,5

4,50

4,40

50

80

110

130

Nominal power input


COP
Energy efficiency class (HP)
COP 50%

W/W (1)

Indoor unit
Dehumidification

l/h

1,7

2,7

nd

nd

Air flow (l/m/h)

l/s

150/170/205

165/195/220

265/300/330

380/405/445

Sound pressure (CO)

dB(A)*

38/41/45

41/44/49

47/50/52

47/49/51

Sound power (CO)

dB(A)

49/52/56

52/55/60

58/61/63

58/60/62

Sound pressure (HP)

dB(A)*

38/41/45

41/44/49

44/50/52

47/49/51

Sound power (HP)

dB(A)

49/52/56

52/55/60

58/61/63

58/60/62

Dimensions (HxLxD)

mm

598x1000x200

598x1000x200

625x1200x232

625x1200x232

Weight

kg

18

20

27

38

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

220/240-1-50

Power Supply
Outdoor unit (HP)

50

80

110

130

Compressor Type

Twin rotary

Twin rotary

Twin rotary

Twin rotary

Maximum pipe length

30

50

50

50

Maximum height difference

30

30

30

30

Chargeless pipe length

20

20

20

20

m3/h

290/665

290/1110

nd/1890

nd/2085

dB(A)**

43

45

51

51

dB(A)

63

65

71

71

dB(A)**

45

47

51

51

dB(A)

65

67

71

71

Dimensions (HxLxD)

mm

595x780x270

795x900x320

795x900x320

795x900x320

Weight

kg

Air flow (Min/Max)


Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)

35

55

75

85

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

12

15

22

23

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

Flare Connections
Starting current
Power Supply

220/240-1-50
SIZE 30 PRELIMINARY DATA

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity

42VQV INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 42VQV

42VQV - CONSOLE UNIT

Fits under a window sill. Reduced footprint and


compact overall dimensions for a wide choice
of installation solutions.

42VQV - CONSOLE UNIT


The XPower 42VQV console units provide optimised comfort levels with an
excellent seasonal energy efficiency ratio. They are slim and stylish and
designed for installation on a wall or under the ceiling.

CONTROLS

2 sizes in cooling only and heat pump capacities from: 1,5kW to 7,2kW in cooling; 1,5kW
to 7,94kW in heating.

FEATURES
Award from the Italian Association of Industrial Design (ADI).
Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 5m. Filter can be washed and regenerated in sunlight.
Motorised louvre allows air distribution direction according to individual preferences.
MyComfort remote control function memorises the preferred user settings.
State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet.

Freedom of choice between infrared remote


control and wired controls.

ACCESSORIES
Condensate discharge pump.
Piping cover kit.

Fits under a window sill. Reduced footprint and compact overall dimensions for
a wide choice of installation solutions.
All key components are easily accessible through the grille without removing
the front panel.

OUTDOOR UNITS

Monosplit: 38VYX_N

24

25

40KQV - CASSETTE UNIT


INVERTER SPLIT SYSTEM

Indoor unit

40KQV050

40KQV080

40KQV110

40KQV130

Outdoor unit (HP)

38VYX050N

38VYX080N

38VYX110N

38VYX130N
12,40

Nominal cooling capacity

kW

4,85

6,60

10,30

Minimum cooling capacity

kW

1,50

2,20

2,20

3,00

Maximum cooling capacity

kW

5,25

7,90

11,50

13,50

1830

2350

3610

4350

W/W

2,65

2,81

2,85

2,85

na

kWh

915

1175

1805

W/W (1)

4,00

4,50

4,00

3,50

Nominal heating capacity

kW

5,07

7,55

10,10

13,00

Minimum heating capacity

kW

1,50

2,2

2,2

Maximum heating capacity

kW

6,00

12

15

1550

2350

3150

4050

W/W

3,27

3,21

3,21

3,21

na

W/W (1)

4,10

4,50

4,50

4,40

50

80

110

130

l/h

1,7

1,8

3,7

4,5

Nominal power input


EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%

Nominal power input


COP
Energy efficiency class (HP)
COP 50%
Indoor unit
Dehumidification
Air flow (l/m/h)

l/s

190/210/250

200/250/300

320/385/455

420/465/525

Sound pressure (CO)

dB(A)*

38/42/45

32/36/39

37/42/45

42/46/48

Sound power (CO)

dB(A)

51/55/58

45/49/52

50/55/58

55/59/61

Sound pressure (HP)

dB(A)*

38/42/45

31/34/37

37/42/45

42/46/48

Sound power (HP)

dB(A)

51/55/58

44/47/50

50/55/58

55/59/61

Dimensions (HxLxD)

mm

298x575x575

298x825x825

298x825x825

298x825x825

Weight

mm

19

38

38

38

Grille Dimensions(HxLxD)

mm

30x720x720

30x960x960

30x960x960

30x960x960

Grille weight

kg

3,1

6,5

6,5

6,5

Outdoor unit (HP)

50

80

110

130

Compressor Type

Twin rotary

Twin rotary

Twin rotary

Twin rotary

Maximum pipe length

30

50

50

50

Maximum height difference

30

30

30

30

Chargeless pipe length

20

20

20

20

m3/h

290/665

290/1110

nd/1890

nd/2085

dB(A)**

43

45

51

51

dB(A)

63

65

71

71

dB(A)**

45

47

51

51

dB(A)

65

67

71

71

Dimensions (HxLxD)

mm

595x780x270

795x900x320

795x900x320

795x900x320

Weight

kg

35

55

75

85

Air flow (Min/Max)


Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)

Flare Connections
Starting current
Power Supply

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

12

15

22

23

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

220/240-1-50

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity

40KQV INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 40KQV

40KQV

Powerful filtration system with photo-catalytic


titanium filters and high-efficiency electrostatic
filters.

40KQV - CASSETTE UNIT


The XPower 40KQV cassettes provide optimised comfort levels with an
excellent seasonal energy efficiency ratio. They received a design awarded
from the Italian Association of Industrial Design and are the ideal choice for
commercial applications.

CONTROLS

4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,5kW in cooling;
1,5kW to 15,0 kW in heating

FEATURES
Simply opening the grille gives access to all critical components.

Freedom of choice between infrared remote control and wired controls.

Fresh air intake and additional outlet grille allow air conditioning of an adjoining
room.
Fresh air inlet for constant air renewal.
Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 5m and high-efficiency electrostatic filters.
Two, three and four-way motorised louvres allow air flow direction according to
individual preferences.

ACCESSORIES
Air supply outlet obstruction kit

Stable indoor comfort with extremely low indoor temperature fluctuation.

OUTDOOR UNITS

Monosplit: 38VYX_N

26

27

40KQV - CASSETTE UNIT


INVERTER SPLIT SYSTEM

Indoor unit

40KQV050

40KQV080

40KQV110

40KQV130

Outdoor unit (HP)

38VYX050N

38VYX080N

38VYX110N

38VYX130N
12,40

Nominal cooling capacity

kW

4,85

6,60

10,30

Minimum cooling capacity

kW

1,50

2,20

2,20

3,00

Maximum cooling capacity

kW

5,25

7,90

11,50

13,50

1830

2350

3610

4350

W/W

2,65

2,81

2,85

2,85

na

kWh

915

1175

1805

W/W (1)

4,00

4,50

4,00

3,50

Nominal heating capacity

kW

5,07

7,55

10,10

13,00

Minimum heating capacity

kW

1,50

2,2

2,2

Maximum heating capacity

kW

6,00

12

15

1550

2350

3150

4050

W/W

3,27

3,21

3,21

3,21

na

W/W (1)

4,10

4,50

4,50

4,40

50

80

110

130

l/h

1,7

1,8

3,7

4,5

Nominal power input


EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%

Nominal power input


COP
Energy efficiency class (HP)
COP 50%
Indoor unit
Dehumidification
Air flow (l/m/h)

l/s

190/210/250

200/250/300

320/385/455

420/465/525

Sound pressure (CO)

dB(A)*

38/42/45

32/36/39

37/42/45

42/46/48

Sound power (CO)

dB(A)

51/55/58

45/49/52

50/55/58

55/59/61

Sound pressure (HP)

dB(A)*

38/42/45

31/34/37

37/42/45

42/46/48

Sound power (HP)

dB(A)

51/55/58

44/47/50

50/55/58

55/59/61

Dimensions (HxLxD)

mm

298x575x575

298x825x825

298x825x825

298x825x825

Weight

mm

19

38

38

38

Grille Dimensions(HxLxD)

mm

30x720x720

30x960x960

30x960x960

30x960x960

Grille weight

kg

3,1

6,5

6,5

6,5

Outdoor unit (HP)

50

80

110

130

Compressor Type

Twin rotary

Twin rotary

Twin rotary

Twin rotary

Maximum pipe length

30

50

50

50

Maximum height difference

30

30

30

30

Chargeless pipe length

20

20

20

20

m3/h

290/665

290/1110

nd/1890

nd/2085

dB(A)**

43

45

51

51

dB(A)

63

65

71

71

dB(A)**

45

47

51

51

dB(A)

65

67

71

71

Dimensions (HxLxD)

mm

595x780x270

795x900x320

795x900x320

795x900x320

Weight

kg

35

55

75

85

Air flow (Min/Max)


Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)

Flare Connections
Starting current
Power Supply

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

12

15

22

23

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

220/240-1-50

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity

40KQV INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 40KQV

40KQV

Powerful filtration system with photo-catalytic


titanium filters and high-efficiency electrostatic
filters.

40KQV - CASSETTE UNIT


The XPower 40KQV cassettes provide optimised comfort levels with an
excellent seasonal energy efficiency ratio. They received a design awarded
from the Italian Association of Industrial Design and are the ideal choice for
commercial applications.

CONTROLS

4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,5kW in cooling;
1,5kW to 15,0 kW in heating

FEATURES
Simply opening the grille gives access to all critical components.

Freedom of choice between infrared remote control and wired controls.

Fresh air intake and additional outlet grille allow air conditioning of an adjoining
room.
Fresh air inlet for constant air renewal.
Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 5m and high-efficiency electrostatic filters.
Two, three and four-way motorised louvres allow air flow direction according to
individual preferences.

ACCESSORIES
Air supply outlet obstruction kit

Stable indoor comfort with extremely low indoor temperature fluctuation.

OUTDOOR UNITS

Monosplit: 38VYX_N

26

27

40DQV - SATELLITE UNITS


INVERTER SPLIT SYSTEM

Indoor units

40DQV050

40DQV080

40DQV110

40DQV130

Outdoor units

38VYX050N

38VYX080N

38VYX110N

38VYX130N
12,40

Nominal cooling capacity

kW

5,00

6,70

10,00

Minimum cooling capacity

kW

1,50

2,10

2,20

3,00

Maximum cooling capacity

kW

5,25

7,20

11,50

13,00

1910

2500

3430

4500

W/W

2,62

2,68

2,92

2,76

ns

kWh

955

1250

1715

W/W (1)

4,30

4,30

4,80

4,30

Nominal heating capacity

kW

5,00

2,00

11,10

13,50

Minimum heating capacity

kW

1,50

2,00

2,20

3,00

Maximum heating capacity

kW

6,00

8,80

12,50

15,00

Nominal power input

1430

2600

3210

3850

COP / Energy, efficiency class

W/W

3,50

2,96

3,46

3,45

Energy efficiency class

W/W

na

W/W (1)

4,80

4,80

5,10

4,80

050

080

110

130

Nominal power input


EER
Energy efficiency class
Annual Energy Consuption (CO)
EER 50%

COP 50%

Indoor unit
Dehumidification

l/h

1,6

3,1

3,8

Air flow (low/med/high)

l/s

210/263/294

205/211/269

291/380/463

390/476/564

Nominal static pressure

Pa

50

50

80

80

Sound Pressure (low/med/high) (CO)

dB(A)

39/40/42

38/40/42

44/46/49

46/49/52

Sound Power (low/med/high) (CO)

dB(A)

52/53/55

51/53/55

57/59/62

59/62/65

Sound Pressure (low/med/high) (HP)

dB(A)

39/40/42

38/40/42

44/46/49

46/49/52

Sound Power (low/med/high) (HP)

dB(A)

52/53/55

51/53/55

57/59/62

59/62/65

Dimensions

mm

925x750x285

925x750x285

1325x750x285

1325x750x285

Weight

kg

32

35

48

48

050

080

110

130

Outdoor unit
Compressor Type

Twin rotary

Twin rotary

Twin rotary

Twin rotary

Maximum pipe lenght

30

50

50

50

Maximum height difference

30

30

30

30

Chargeless pipe lenght


Air flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
Dimensions (HxLxD)
Weight
Flare Connections
Starting current
Power Supply

20

20

20

20

m3/h

290/665

290/1110

nd/1890

nd/2085

dB(A)**

43

45

51

51

dB(A)

63

65

71

71

dB(A)**

45

47

51

51

dB(A)

65

67

71

71

mm

595x780x270

795x900x320

795x900x320

795x900x320

kg

35

55

75

85

inch

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

12

15

22

23

V-ph-Hz

220-240-1-50

220/240-1-50

220/240-1-50

220/240-1-50

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity

285

40DQV INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 40DQV

40DQV

Ultra-slim profile - only 285 mm for all sizes,


thanks to the Carrier-patented V-shaped coil.

40DQV - SATELLITE UNITS


The new ducted above-ceiling XPower units from Carrier represent a
breakthrough in design terms. They provide best level of comfort with an
excellent seasonal energy efficiency ratio. The slimmest profile ever and
flexible installation options make this unit the best choice for homes and
light commercial premises.

CONTROLS

4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,0kW in cooling;
1,5kW to 15,0 kW in heating.

FEATURES

Freedom of choice between infrared remote control and wired controls.

Designed for front or side air discharge.


Unique design with lateral air discharge allows the unit to be installed in a corridor.
Modular filter and panel sizes allow flexible unit mounting with rear or bottom
air return.
Equipped with pre-punched 150-mm diameter fresh air intakes on both sides,
and with pre-punched Octopus discharge panel.

ACCESSORIES
MyComfort infrared control kit.

Control box equipped with 1.5-m cable for flexible positioning and accessibility.

OUTDOOR UNITS

Monosplit: 38VYX_N

28

29

40DQV - SATELLITE UNITS


INVERTER SPLIT SYSTEM

Indoor units

40DQV050

40DQV080

40DQV110

40DQV130

Outdoor units

38VYX050N

38VYX080N

38VYX110N

38VYX130N
12,40

Nominal cooling capacity

kW

5,00

6,70

10,00

Minimum cooling capacity

kW

1,50

2,10

2,20

3,00

Maximum cooling capacity

kW

5,25

7,20

11,50

13,00

1910

2500

3430

4500

W/W

2,62

2,68

2,92

2,76

ns

kWh

955

1250

1715

W/W (1)

4,30

4,30

4,80

4,30

Nominal heating capacity

kW

5,00

2,00

11,10

13,50

Minimum heating capacity

kW

1,50

2,00

2,20

3,00

Maximum heating capacity

kW

6,00

8,80

12,50

15,00

Nominal power input

1430

2600

3210

3850

COP / Energy, efficiency class

W/W

3,50

2,96

3,46

3,45

Energy efficiency class

W/W

na

W/W (1)

4,80

4,80

5,10

4,80

050

080

110

130

Nominal power input


EER
Energy efficiency class
Annual Energy Consuption (CO)
EER 50%

COP 50%

Indoor unit
Dehumidification

l/h

1,6

3,1

3,8

Air flow (low/med/high)

l/s

210/263/294

205/211/269

291/380/463

390/476/564

Nominal static pressure

Pa

50

50

80

80

Sound Pressure (low/med/high) (CO)

dB(A)

39/40/42

38/40/42

44/46/49

46/49/52

Sound Power (low/med/high) (CO)

dB(A)

52/53/55

51/53/55

57/59/62

59/62/65

Sound Pressure (low/med/high) (HP)

dB(A)

39/40/42

38/40/42

44/46/49

46/49/52

Sound Power (low/med/high) (HP)

dB(A)

52/53/55

51/53/55

57/59/62

59/62/65

Dimensions

mm

925x750x285

925x750x285

1325x750x285

1325x750x285

Weight

kg

32

35

48

48

050

080

110

130

Outdoor unit
Compressor Type

Twin rotary

Twin rotary

Twin rotary

Twin rotary

Maximum pipe lenght

30

50

50

50

Maximum height difference

30

30

30

30

Chargeless pipe lenght


Air flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
Dimensions (HxLxD)
Weight
Flare Connections
Starting current
Power Supply

20

20

20

20

m3/h

290/665

290/1110

nd/1890

nd/2085

dB(A)**

43

45

51

51

dB(A)

63

65

71

71

dB(A)**

45

47

51

51

dB(A)

65

67

71

71

mm

595x780x270

795x900x320

795x900x320

795x900x320

kg

35

55

75

85

inch

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

12

15

22

23

V-ph-Hz

220-240-1-50

220/240-1-50

220/240-1-50

220/240-1-50

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity

285

40DQV INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 40DQV

40DQV

Ultra-slim profile - only 285 mm for all sizes,


thanks to the Carrier-patented V-shaped coil.

40DQV - SATELLITE UNITS


The new ducted above-ceiling XPower units from Carrier represent a
breakthrough in design terms. They provide best level of comfort with an
excellent seasonal energy efficiency ratio. The slimmest profile ever and
flexible installation options make this unit the best choice for homes and
light commercial premises.

CONTROLS

4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,0kW in cooling;
1,5kW to 15,0 kW in heating.

FEATURES

Freedom of choice between infrared remote control and wired controls.

Designed for front or side air discharge.


Unique design with lateral air discharge allows the unit to be installed in a corridor.
Modular filter and panel sizes allow flexible unit mounting with rear or bottom
air return.
Equipped with pre-punched 150-mm diameter fresh air intakes on both sides,
and with pre-punched Octopus discharge panel.

ACCESSORIES
MyComfort infrared control kit.

Control box equipped with 1.5-m cable for flexible positioning and accessibility.

OUTDOOR UNITS

Monosplit: 38VYX_N

28

29

38VYX_N - CONDENSING UNITS


Outdoor unit (HP)

38VYX50N

38VYX080N

38VYX110N

38VYX130N

Compressor Type

Twin rotary

Twin rotary

Twin rotary

Twin rotary

Maximum pipe length

30

50

50

50

Maximum height difference

30

30

30

30

Chargeless pipe length

20

20

20

20

m3/h

290/665

290/1110

nd/1890

nd/2085

dB(A)**

43

45

51

51

dB(A)

63

65

71

71

dB(A)**

45

47

51

51

dB(A)

65

67

71

71

mm

595x780x270

795x900x320

795x900x320

795x900x320

Air flow (Min/Max)


Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
Dimensions (HxLxD)
Weight
Flare Connections
Starting current
Power Supply

kg

35

55

75

85

inch

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

12

15

22

23

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

220/240-1-50

38VYX_N INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 38VYX_N

INVERTER SPLIT SYSTEM

** Sound pressure level in emispheric field at 4 m


Performances evaluated with 5m interconnecting tubes and according to EN14511

Twin rotary compressor to reduce vibration and


noise and to provide superior efficiency performance.

OPERATING LIMITS
Cooling mode

Heating mode

38VYX_N
maximum
conditions

outdoor temperature 43C.


indoor temperature 32C dry bulb / 23C wet bulb.

minimum
conditions

outdoor temperature -5C (080, 110, 130); -15C (050).


indoor temperature 21C dry bulb / 15C wet bulb.

maximum
conditions

outdoor temperature 24C dry bulb / 18C wet bulb.


indoor temperature 27C dry bulb.

minimum
conditions

outdoor temperature -15C dry bulb.

38VYX_N - CONDENSING UNITS

CONTROLS

4 sizes in cooling only and heat pump.

FEATURES

Freedom of choice between infrared remote control and wired controls.

Systems can operate at -5C in cooling mode and -15C in heating mode.
Outdoor and outdoor fan speeds are electronically fine tuned to deliver the needed air
flow reach the best performance.

INDOOR UNITS

No current peaks: Start-up current absorption is always lower than operating current
value.
Advanced self-diagnosis tool for an automatic complete system check-up and for maintenance routine monitoring.
Designed for challenging installations. Up to 50 m in distance and 30 m in elevation;
chargeless up to 20 m.

42PQV_S lc

The pulse modulation valve (PVM) regulates the refrigerant flow in the circuit.
42VQV

40KQV

40DQV

30

31

38VYX_N - CONDENSING UNITS


Outdoor unit (HP)

38VYX50N

38VYX080N

38VYX110N

38VYX130N

Compressor Type

Twin rotary

Twin rotary

Twin rotary

Twin rotary

Maximum pipe length

30

50

50

50

Maximum height difference

30

30

30

30

Chargeless pipe length

20

20

20

20

m3/h

290/665

290/1110

nd/1890

nd/2085

dB(A)**

43

45

51

51

dB(A)

63

65

71

71

dB(A)**

45

47

51

51

dB(A)

65

67

71

71

mm

595x780x270

795x900x320

795x900x320

795x900x320

Air flow (Min/Max)


Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
Dimensions (HxLxD)
Weight
Flare Connections
Starting current
Power Supply

kg

35

55

75

85

inch

1/4 - 1/2

3/8 - 5/8

3/8 - 5/8

3/8 - 5/8

12

15

22

23

V-ph-Hz

220/240-1-50

220/240-1-50

220/240-1-50

220/240-1-50

38VYX_N INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 38VYX_N

INVERTER SPLIT SYSTEM

** Sound pressure level in emispheric field at 4 m


Performances evaluated with 5m interconnecting tubes and according to EN14511

Twin rotary compressor to reduce vibration and


noise and to provide superior efficiency performance.

OPERATING LIMITS
Cooling mode

Heating mode

38VYX_N
maximum
conditions

outdoor temperature 43C.


indoor temperature 32C dry bulb / 23C wet bulb.

minimum
conditions

outdoor temperature -5C (080, 110, 130); -15C (050).


indoor temperature 21C dry bulb / 15C wet bulb.

maximum
conditions

outdoor temperature 24C dry bulb / 18C wet bulb.


indoor temperature 27C dry bulb.

minimum
conditions

outdoor temperature -15C dry bulb.

38VYX_N - CONDENSING UNITS

CONTROLS

4 sizes in cooling only and heat pump.

FEATURES

Freedom of choice between infrared remote control and wired controls.

Systems can operate at -5C in cooling mode and -15C in heating mode.
Outdoor and outdoor fan speeds are electronically fine tuned to deliver the needed air
flow reach the best performance.

INDOOR UNITS

No current peaks: Start-up current absorption is always lower than operating current
value.
Advanced self-diagnosis tool for an automatic complete system check-up and for maintenance routine monitoring.
Designed for challenging installations. Up to 50 m in distance and 30 m in elevation;
chargeless up to 20 m.

42PQV_S lc

The pulse modulation valve (PVM) regulates the refrigerant flow in the circuit.
42VQV

40KQV

40DQV

30

31

38VGM_N/VYM_N - MULTI-SPLIT CONDENSING UNIT


INVERTER SPLIT SYSTEM

38VYM-14N

38VYM-18N

38VYM-28N

N. of compressors

Model HP

Compressor type

Twin Rotary

Twin Rotary

Twin Rotary

Twin Rotary

38VYM-32N

Refrigerant charge

900

1150

2400

2400

Maximum pipe lenght per unit

20

20

25

25

Mimimum pipe lenght per unit

m (4)

2(5)

2(5)

Maximum height difference

10

10

15

15

Total pipe lenght

30

30

50

70

Total chargless pipe lenght

30

30

50

70

dB (A)

43

43

48

48

Min. no. of connected indoor units


Sound pressure (CO)
Sound power (CO)

dB (A)

63

63

68

68

dB (A) (2)

44

44

48

48

dB (A)

64

64

68

68

Air flow (min./nominal/max)

l/s

344/539/656

344/539/656

383/656/689

383/656/689

Dimensions (H x L x D)

mm

590x800x300

590x800x300

800x800x300

800x800x300

Weight

kg

46

50

65

65

n x (in) (3)

2x(1/4) - 2x(3/8)

2x(1/4) - 2x(3/8)

3x(1/4) - 3x(3/8)

4x(1/4) - 4x(3/8)

A (5)

11,5

11,5

14,2

14,2

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

Sound pressure (HP)


Sound power (HP)

Flare Connections
Maximum running current
Power supply

38VGM_N/VYM_N INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 38VGM_N/VYM_N

38VGM_N/VYM_N Inverter Multi Condensing Unit

DC Blended Inverter Technology the sophisticated electronics system maximises performance and inverter savings.

PRELIMINARY DATA

38VGM_N/VYM_N
38VGM-14N

38VGM-18N

38VGM-18N

N. of compressors

Model CO

Compressor type

Twin Rotary

Twin Rotary

Twin Rotary

Twin Rotary

900

1150

2400

2400
25

Refrigerant charge

38VGM-32N

Maximum pipe lenght per unit

20

20

25

Mimimum pipe lenght per unit

m (4)

2 (5)

2 (5)

Maximum height difference

10

10

15

15

Total pipe lenght

30

30

50

70

Total chargless pipe lenght

30

30

50

70

dB(A) (2)

43

43

48

48

dB (A)

63

63

68

68

Air flow (min./nominal/max)

l/s

344/539/656

344/539/656

383/656/689

383/656/689

Dimensions (H x L x D)

mm

590x800x300

590x800x300

800x800x300

800x800x300

Weight

kg

46

50

65

65

n x

2x(1/4) - 2x(3/8)

2x(1/4) - 2x(3/8)

3x(1/4) - 3x(3/8)

4x(1/4) - 4x(3/8)

Min. no. of connected indoor units


Sound pressure (CO)
Sound power (CO)

Flare Connections
Maximum running current
Power supply

2) Sound pressure level in emispheric field at 4 m


3) Connecting pipes for PQM015 and SQM015 must be 1/4" - 1/2"
Flare adapter to be mounted on outdoor unit will be supplied together with indoor unit
4) 5 meters with one unit connected.
5) Variable speed compressor can reduce this value during operation.

11,5

11,5

14,2

14,2

230-1-50

230-1-50

230-1-50

230-1-50
PRELIMINARY DATA

CONTROLS

38VGM_N/VYM_N is the Carrier inverter multi-split outdoor unit. Carrier's


inverter multisplit range multiplies the XPower advantages, so several
rooms can be air conditioned at low cost.
4 sizes in cooling only and heat pump.

FEATURES
Suitable for long-distance pipes: a single condensing unit can be connected up
to four hi-walls mounted in different areas of the house.
Self-diagnosis system: counting on 40 different check codes, the diagnostic
process is extremely precise and effective.
Electronic modulation valves regulate the refrigerant flow and optimise the cooling temperature in the refrigeration circuit.

Modular control system

ACCESSORIES/OPTIONS
Wall brackets

INDOOR UNITS

The provided refrigerant charge fits any combination; systems don't require any
additional charge, making installations easier and faster.
Corrosion-resistant base and cabinet, made UV-resistant polymer materials.
42PQM_S

40SQM

32

33

38VGM_N/VYM_N - MULTI-SPLIT CONDENSING UNIT


INVERTER SPLIT SYSTEM

38VYM-14N

38VYM-18N

38VYM-28N

N. of compressors

Model HP

Compressor type

Twin Rotary

Twin Rotary

Twin Rotary

Twin Rotary

38VYM-32N

Refrigerant charge

900

1150

2400

2400

Maximum pipe lenght per unit

20

20

25

25

Mimimum pipe lenght per unit

m (4)

2(5)

2(5)

Maximum height difference

10

10

15

15

Total pipe lenght

30

30

50

70

Total chargless pipe lenght

30

30

50

70

dB (A)

43

43

48

48

Min. no. of connected indoor units


Sound pressure (CO)
Sound power (CO)

dB (A)

63

63

68

68

dB (A) (2)

44

44

48

48

dB (A)

64

64

68

68

Air flow (min./nominal/max)

l/s

344/539/656

344/539/656

383/656/689

383/656/689

Dimensions (H x L x D)

mm

590x800x300

590x800x300

800x800x300

800x800x300

Weight

kg

46

50

65

65

n x (in) (3)

2x(1/4) - 2x(3/8)

2x(1/4) - 2x(3/8)

3x(1/4) - 3x(3/8)

4x(1/4) - 4x(3/8)

A (5)

11,5

11,5

14,2

14,2

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

Sound pressure (HP)


Sound power (HP)

Flare Connections
Maximum running current
Power supply

38VGM_N/VYM_N INVERTER SPLIT SYSTEM

INVERTER SPLIT SYSTEM 38VGM_N/VYM_N

38VGM_N/VYM_N Inverter Multi Condensing Unit

DC Blended Inverter Technology the sophisticated electronics system maximises performance and inverter savings.

PRELIMINARY DATA

38VGM_N/VYM_N
38VGM-14N

38VGM-18N

38VGM-18N

N. of compressors

Model CO

Compressor type

Twin Rotary

Twin Rotary

Twin Rotary

Twin Rotary

900

1150

2400

2400
25

Refrigerant charge

38VGM-32N

Maximum pipe lenght per unit

20

20

25

Mimimum pipe lenght per unit

m (4)

2 (5)

2 (5)

Maximum height difference

10

10

15

15

Total pipe lenght

30

30

50

70

Total chargless pipe lenght

30

30

50

70

dB(A) (2)

43

43

48

48

dB (A)

63

63

68

68

Air flow (min./nominal/max)

l/s

344/539/656

344/539/656

383/656/689

383/656/689

Dimensions (H x L x D)

mm

590x800x300

590x800x300

800x800x300

800x800x300

Weight

kg

46

50

65

65

n x

2x(1/4) - 2x(3/8)

2x(1/4) - 2x(3/8)

3x(1/4) - 3x(3/8)

4x(1/4) - 4x(3/8)

Min. no. of connected indoor units


Sound pressure (CO)
Sound power (CO)

Flare Connections
Maximum running current
Power supply

2) Sound pressure level in emispheric field at 4 m


3) Connecting pipes for PQM015 and SQM015 must be 1/4" - 1/2"
Flare adapter to be mounted on outdoor unit will be supplied together with indoor unit
4) 5 meters with one unit connected.
5) Variable speed compressor can reduce this value during operation.

11,5

11,5

14,2

14,2

230-1-50

230-1-50

230-1-50

230-1-50
PRELIMINARY DATA

CONTROLS

38VGM_N/VYM_N is the Carrier inverter multi-split outdoor unit. Carrier's


inverter multisplit range multiplies the XPower advantages, so several
rooms can be air conditioned at low cost.
4 sizes in cooling only and heat pump.

FEATURES
Suitable for long-distance pipes: a single condensing unit can be connected up
to four hi-walls mounted in different areas of the house.
Self-diagnosis system: counting on 40 different check codes, the diagnostic
process is extremely precise and effective.
Electronic modulation valves regulate the refrigerant flow and optimise the cooling temperature in the refrigeration circuit.

Modular control system

ACCESSORIES/OPTIONS
Wall brackets

INDOOR UNITS

The provided refrigerant charge fits any combination; systems don't require any
additional charge, making installations easier and faster.
Corrosion-resistant base and cabinet, made UV-resistant polymer materials.
42PQM_S

40SQM

32

33

42PHQ_S - HI-WALL UNIT


FIXED SPEED SPLIT SYSTEM

Indoor unit

42PHQ009S

42PHQ012S

42PHQ014S

42PHQ018S

42PHQ024S

Outdoor unit

38BC-009G

38BC-012G

38BC-014G

38GL-018G

38GL-024G

Cooling capacity (CO)

kW

2,82

3,43

3,90

5,22

6,03

Power input (CO)

920

1200

1540

2130

2500
2,41

Energy efficiency class

3,07

2,86

2,53

2,45

EER

W/W

460

Annual energy consumption (CO)

kWh

600

770

1065

1250
38YY-024G

Outdoor unit

38BH-009G

38BH-0124

38BH-0144

38YY-018G

Cooling capacity (CO)

kW

2,75

3,37

3,89

5,02

6,14

Power input (CO)

840

1120

1480

2010

2510

W/W

3,27

3,01

2,63

2,50

2,45

560

740

1005

1255

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

420

Heating capacity

kW

3,07

3,65

4,40

5,59

7,53

Power input (HP)

880

1190

1490

1960

2680

W/W

3,49

3,07

2,95

2,85

2,81

009

012

014

018

024

COP
Energy efficiency class (HP)

42PHQ_S FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 42PHQ_S

42PHQ_S - HI-Wall unit

Ioniser Function
Indoor unit
Dehumidification

l/h

0,90

1,20

1,46

1,54

2,08

Air flow (l/m/h)

l/s

116/132/154

125/143/165

150/168/187

204/223/242

250/275/300

Sound pressure (l/m/h)

dB(A)*

30/31/35

32/36/39

39/41/43

39/41/43

43/46/49

Sound power (l/m/h)

dB(A)

43/44/48

45/49/52

52/54/56

52/54/57

56/59/62

Dimensions (HxLxD)

mm

260x790x196

260x790x196

260x790x196

295x1080x200

295x1080x200

Weight
Power Supply

kg

8,6

8,6

8,6

14

14

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

009

012

014

018

024

Outdoor unit
Compressor Type

Rotary

Rotary

Rotary

Rotary

Rotary

Maximum pipe length

10

15

15

30

40

Maximum height difference

15

15

Chargeless

10

10

10

dB(A)**

38/38

38/38

40/40

45/46

45/48

dB(A)

58/58

58/58

60/60

65/66

65/68

Dimensions (HxLxD)

mm

550x780x270

550x780x270

590x750x280

590x800x300

803x800x300

Weight (CO/HP)

kg

30/33

33/36

35/37

45

51/60

Flare Connections

3/8 - 1/4

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

Sound pressure (CO/HP)


Sound power (CO/HP)

Power Supply

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511

42PHQ_S - HI-WALL UNITS


Creat-ion recreates the atmosphere of natural environments in your home,
providing a sense of well-being and vitality for all the family.

CONTROLS

10 sizes in cooling only and heat pump capacities from: 2,82 kW to 6,03 kW in cooling;
2,75 kW to 6,14 kW in heating.

FEATURES
Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter,
regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment.
The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being.
Customised air distribution - six different air flow positions and exclusive Twin
Swing air distribution function.

My comfort
Remote Control

ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter

Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.
Programmable timer for easy on and off selection with great energy savings.
Creat-ion is felt, but not heard. The indoor unit is extremely quiet to ensure total
relaxation.
Exclusive, ergonomic and personalised remote control - the unique MyComfort
function memorises preferred user settings and ensures easy recall.

OUTDOOR UNITS

Monosplit: 38BC/BH and 38GL/YY


Multisplit: 38GL_M/YY_M

34

35

42PHQ_S - HI-WALL UNIT


FIXED SPEED SPLIT SYSTEM

Indoor unit

42PHQ009S

42PHQ012S

42PHQ014S

42PHQ018S

42PHQ024S

Outdoor unit

38BC-009G

38BC-012G

38BC-014G

38GL-018G

38GL-024G

Cooling capacity (CO)

kW

2,82

3,43

3,90

5,22

6,03

Power input (CO)

920

1200

1540

2130

2500
2,41

Energy efficiency class

3,07

2,86

2,53

2,45

EER

W/W

460

Annual energy consumption (CO)

kWh

600

770

1065

1250
38YY-024G

Outdoor unit

38BH-009G

38BH-0124

38BH-0144

38YY-018G

Cooling capacity (CO)

kW

2,75

3,37

3,89

5,02

6,14

Power input (CO)

840

1120

1480

2010

2510

W/W

3,27

3,01

2,63

2,50

2,45

560

740

1005

1255

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

420

Heating capacity

kW

3,07

3,65

4,40

5,59

7,53

Power input (HP)

880

1190

1490

1960

2680

W/W

3,49

3,07

2,95

2,85

2,81

009

012

014

018

024

COP
Energy efficiency class (HP)

42PHQ_S FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 42PHQ_S

42PHQ_S - HI-Wall unit

Ioniser Function
Indoor unit
Dehumidification

l/h

0,90

1,20

1,46

1,54

2,08

Air flow (l/m/h)

l/s

116/132/154

125/143/165

150/168/187

204/223/242

250/275/300

Sound pressure (l/m/h)

dB(A)*

30/31/35

32/36/39

39/41/43

39/41/43

43/46/49

Sound power (l/m/h)

dB(A)

43/44/48

45/49/52

52/54/56

52/54/57

56/59/62

Dimensions (HxLxD)

mm

260x790x196

260x790x196

260x790x196

295x1080x200

295x1080x200

Weight
Power Supply

kg

8,6

8,6

8,6

14

14

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

009

012

014

018

024

Outdoor unit
Compressor Type

Rotary

Rotary

Rotary

Rotary

Rotary

Maximum pipe length

10

15

15

30

40

Maximum height difference

15

15

Chargeless

10

10

10

dB(A)**

38/38

38/38

40/40

45/46

45/48

dB(A)

58/58

58/58

60/60

65/66

65/68

Dimensions (HxLxD)

mm

550x780x270

550x780x270

590x750x280

590x800x300

803x800x300

Weight (CO/HP)

kg

30/33

33/36

35/37

45

51/60

Flare Connections

3/8 - 1/4

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

Sound pressure (CO/HP)


Sound power (CO/HP)

Power Supply

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511

42PHQ_S - HI-WALL UNITS


Creat-ion recreates the atmosphere of natural environments in your home,
providing a sense of well-being and vitality for all the family.

CONTROLS

10 sizes in cooling only and heat pump capacities from: 2,82 kW to 6,03 kW in cooling;
2,75 kW to 6,14 kW in heating.

FEATURES
Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter,
regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment.
The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being.
Customised air distribution - six different air flow positions and exclusive Twin
Swing air distribution function.

My comfort
Remote Control

ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter

Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.
Programmable timer for easy on and off selection with great energy savings.
Creat-ion is felt, but not heard. The indoor unit is extremely quiet to ensure total
relaxation.
Exclusive, ergonomic and personalised remote control - the unique MyComfort
function memorises preferred user settings and ensures easy recall.

OUTDOOR UNITS

Monosplit: 38BC/BH and 38GL/YY


Multisplit: 38GL_M/YY_M

34

35

42PHQ_A - HI-WALL UNIT


FIXED SPEED SPLIT SYSTEM
42PHQ_A - HI-Wall unit
Indoor unit

42PHQ009A

42PHQ012A

38YP-009

38YP-012

Cooling capacity (CO)

kW

2,75

3,50

Power input (CO)

856

1090

W/W

3,21

3,21

EER
Energy efficiency class (CO)

A
545

Annual energy consumption

kWh

428

Heating capacity

kW

3,07

3,80

Power input (HP)

850

1052

W/W

3,61

3,61

009

012

COP
Energy efficiency class (HP)
Indoor unit
Dehumidification

l/h

0,9

1,2

Air flow (l/m/h)

l/s

93/118/153

118/132/203

Sound pressure (l/m/h)

dB(A)*

27/30/39

41/43/45

Sound power (l/m/h)

dB(A)

40/43/52

52/54/56

Dimensions (HxLxD)

mm

260x790x196

260x790x196

Weight

kg

8,6

8,6

V-ph-Hz

230-1-50

230-1-50

Power Supply
Outdoor unit (HP)

009

012

Compressor Type

Rotary

Rotary

Maximum pipe length

10

15

Maximum height difference

Chargeless

10

10

dB(A)**

40

41

dB(A)

60

61

Dimensions (HxLxD)

mm

550x780x270

550x780x270

Weight

kg

32

40

Flare Connections

3/8 - 1/4

1/2 - 1/4

V-ph-Hz

230-1-50

230-1-50

Sound pressure
Sound power

Power Supply

Class A efficiency in cooling and heating


The ultimate evolution of comfort with maximised savings.

42PHQ_A FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 42PHQ_A

Outdoor unit (HP)

42PHQ_A - HI-WALL UNITS


Creat-ion recreates the atmosphere of natural environments in your home,
providing a sense of well-being and vitality for all the family.

CONTROLS

2 sizes in cooling only and heat pump capacities from: 2,75 kW to 3,50 kW in cooling;
3,07 kW to 3,80 kW in heating.
Ionizer function

FEATURES
Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.
Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter,
regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment.

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511

The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being.

ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter

Programmable timer for easy on and off selection with great energy savings;
includes a sleep function to automatically manage the right temperature during
the night.
Exclusive, ergonomic and personalised remote control - the unique MyComfort
function memorises preferred user settings and ensures easy recall.

OUTDOOR UNITS

Monosplit: 38YP

36

37

42PHQ_A - HI-WALL UNIT


FIXED SPEED SPLIT SYSTEM
42PHQ_A - HI-Wall unit
Indoor unit

42PHQ009A

42PHQ012A

38YP-009

38YP-012

Cooling capacity (CO)

kW

2,75

3,50

Power input (CO)

856

1090

W/W

3,21

3,21

EER
Energy efficiency class (CO)

A
545

Annual energy consumption

kWh

428

Heating capacity

kW

3,07

3,80

Power input (HP)

850

1052

W/W

3,61

3,61

009

012

COP
Energy efficiency class (HP)
Indoor unit
Dehumidification

l/h

0,9

1,2

Air flow (l/m/h)

l/s

93/118/153

118/132/203

Sound pressure (l/m/h)

dB(A)*

27/30/39

41/43/45

Sound power (l/m/h)

dB(A)

40/43/52

52/54/56

Dimensions (HxLxD)

mm

260x790x196

260x790x196

Weight

kg

8,6

8,6

V-ph-Hz

230-1-50

230-1-50

Power Supply
Outdoor unit (HP)

009

012

Compressor Type

Rotary

Rotary

Maximum pipe length

10

15

Maximum height difference

Chargeless

10

10

dB(A)**

40

41

dB(A)

60

61

Dimensions (HxLxD)

mm

550x780x270

550x780x270

Weight

kg

32

40

Flare Connections

3/8 - 1/4

1/2 - 1/4

V-ph-Hz

230-1-50

230-1-50

Sound pressure
Sound power

Power Supply

Class A efficiency in cooling and heating


The ultimate evolution of comfort with maximised savings.

42PHQ_A FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 42PHQ_A

Outdoor unit (HP)

42PHQ_A - HI-WALL UNITS


Creat-ion recreates the atmosphere of natural environments in your home,
providing a sense of well-being and vitality for all the family.

CONTROLS

2 sizes in cooling only and heat pump capacities from: 2,75 kW to 3,50 kW in cooling;
3,07 kW to 3,80 kW in heating.
Ionizer function

FEATURES
Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.
Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter,
regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment.

* Sound pressure level in a free field according to JIS9612 Standard


** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511

The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being.

ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter

Programmable timer for easy on and off selection with great energy savings;
includes a sleep function to automatically manage the right temperature during
the night.
Exclusive, ergonomic and personalised remote control - the unique MyComfort
function memorises preferred user settings and ensures easy recall.

OUTDOOR UNITS

Monosplit: 38YP

36

37

42VMC_N - CONSOLE UNITS


FIXED SPEED SPLIT SYSTEM

Indoor unit

42VMC009N

42VMC012N

42VMC014N

42VMC018N

42VMC024N

42VMC028N

42VMC036N

42VMC048N

Outdoor unit (CO)

38BC-009G

38BC-012G

38BC-014G

38GL-018G

38GL-024G

38GL-028G9

38GL-036G9

38GL-048G9

Cooling capacity (CO)

kW

2,69

3,27

4,47

5,34

6,01

7,6

8,3

10,1

Power input (CO)

920

1200

1640

2190

2510

2860

3280

3500

W/W

2,92

2,73

2,73

2,44

2,39

2,66

2,53

2,89

460

600

820

1095

1255

1430

1640

1750
38YY-048G9

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

Outdoor unit (HP)

38BH-009G

38BH-012G

38BH-014G

38YY-018G

38YY-024G

38YY-028G9

38YY-036G9

Cooling capacity (CO)

kW

2,62

3,22

4,35

5,26

6,4

7,3

8,1

10,1

Power input (CO)

830

1130

1630

2090

2720

3070

3430

3510

W/W

3,16

2,85

2,67

2,52

2,35

2,38

2,36

2,88

565

815

1045

1360

1535

1715

1755

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

415

Heating capacity

kW

2,94

3,52

4,75

5,67

6,8

8,9

10,9

Power input (HP)

960

1260

1570

2030

2570

2880

3230

3800

W/W

3,06

2,79

3,03

2,79

2,65

2,78

2,76

2,87

09

12

14

18

24

28

36

48

2,5

2,5

COP
Energy efficiency class (HP)
Indoor unit
Electric heater

kW

Dehumidification

l/h

1,2

1,5

1,7

2,2

2,8

3,1

3,6

Air flow (l/m/h)

l/s

78/88/100

85/96/114

130/150/170

136/162/199

164/202/249

240/275/302

240/275/302

313/337/364

Sound pressure (l/m/h)

dB(A)*

33/36/39

36/38/42

38/39/41

38/41/46

41/44/50

44/48/50

44/48/50

48/50/53

Sound power (l/m/h)

dB(A)

44/47/50

47/49/53

49/50/52

49/52/57

52/55/61

55/59/61

55/59/61

59/61/64

Dimensions (HxLxD)

mm

540x850x200

540x850x200

Weight
Power Supply

kg

15

16

18

18

20

35

35

36

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

09

12

14

18

24

28

36

48

8 sizes in cooling only and heat pump capacities from: 2,69kW to 10,10kW in cooling;
2,94kW to 10,9kW in heating.

rotary

rotary

rotary

rotary

rotary

scroll

scroll

scroll

15

15

15

30

40

40

50

50

Compressor Type

Air flow (CO/HP)


Sound pressure (CO/HP)
Sound power (CO/HP)
Dimensions (HxLxD) (CO)

598x1000x200 598x1000x200 598x1000x200 610x1200x225 610x1200x225 610x1200x225

15

15

25

30

30

10

10

10

m3/h

1540

1540

1540

1900/2400

1900/2600

2400

2400/3100

4900/4200

38 / 38

38 / 38

40 / 40

45 / 46

45 / 49

48 / 48

49 / 52

53 / 54

Award from the Italian Association of Industrial Design (ADI).

dB(A)

58 / 58

58 / 58

60 / 60

65 / 66

65 / 69

68 / 68

69 / 72

73 / 74

mm

590x750x280

590x750x280

590x750x280

590x800x300

590x800x300

803x800x300

803x800x300

1264x800x300

Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 m. Filter can be washed and regenerated in sunlight.

kg

30

33

35

45

51

65

65

92

Dimensions (HxLxD) (HP)

mm

590x750x280

590x750x280

590x750x280

590x800x300

803x800x300

803x800x300

803x800x300

1264x800x300

Flare Connections
Starting current
Power Supply
*
**

FEATURES

dB(A)**

Weight (CO)
Weight (HP)

42VMC_N - CONSOLE UNITS


Carrier console units are slim and stylish, making many conventional air
conditioning units look old-fashioned in comparison. A versatile solution,
designed for installation on a wall or under the ceiling.

Outdoor unit
Maximum pipe length (CO/HP)
Maximum height difference
(CO/HP)
Chargeless pipe length (CO/HP)

Stylish design for modern interiors.

kg

33

36

37

47

60

67

68

94

inch

3/8 - 1/4

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

5/8 - 1/4

3/4 - 3/8

3/4 - 3/8

17

24

28

50

56

37

39

54

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

400-3-50

400-3-50

400-3-50

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4 m.

Motorised louvre allows air distribution direction according to individual preferences.


MyComfort remote control function memorises the preferred user settings.
State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet.

42VMC_N FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 42VMC_N

42 VMC-N Console & Underceiling

CONTROLS

Freedom of choice between infrared remote


control and wired controls.

ACCESSORIES
Condensate discharge pump
Hot water coil kit
Piping cover kit
Electric heater

Fits under a window sill. Reduced footprint and compact overall dimensions for
a wide choice of installation solutions.
All key components are easily accessible through the grille without removing
the front panel.

OUTDOOR UNITS

Monosplit: 38BC/BH and 38GL/YY


Multisplit: 38GL_M/YL_M

38

39

42VMC_N - CONSOLE UNITS


FIXED SPEED SPLIT SYSTEM

Indoor unit

42VMC009N

42VMC012N

42VMC014N

42VMC018N

42VMC024N

42VMC028N

42VMC036N

42VMC048N

Outdoor unit (CO)

38BC-009G

38BC-012G

38BC-014G

38GL-018G

38GL-024G

38GL-028G9

38GL-036G9

38GL-048G9

Cooling capacity (CO)

kW

2,69

3,27

4,47

5,34

6,01

7,6

8,3

10,1

Power input (CO)

920

1200

1640

2190

2510

2860

3280

3500

W/W

2,92

2,73

2,73

2,44

2,39

2,66

2,53

2,89

460

600

820

1095

1255

1430

1640

1750
38YY-048G9

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

Outdoor unit (HP)

38BH-009G

38BH-012G

38BH-014G

38YY-018G

38YY-024G

38YY-028G9

38YY-036G9

Cooling capacity (CO)

kW

2,62

3,22

4,35

5,26

6,4

7,3

8,1

10,1

Power input (CO)

830

1130

1630

2090

2720

3070

3430

3510

W/W

3,16

2,85

2,67

2,52

2,35

2,38

2,36

2,88

565

815

1045

1360

1535

1715

1755

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

415

Heating capacity

kW

2,94

3,52

4,75

5,67

6,8

8,9

10,9

Power input (HP)

960

1260

1570

2030

2570

2880

3230

3800

W/W

3,06

2,79

3,03

2,79

2,65

2,78

2,76

2,87

09

12

14

18

24

28

36

48

2,5

2,5

COP
Energy efficiency class (HP)
Indoor unit
Electric heater

kW

Dehumidification

l/h

1,2

1,5

1,7

2,2

2,8

3,1

3,6

Air flow (l/m/h)

l/s

78/88/100

85/96/114

130/150/170

136/162/199

164/202/249

240/275/302

240/275/302

313/337/364

Sound pressure (l/m/h)

dB(A)*

33/36/39

36/38/42

38/39/41

38/41/46

41/44/50

44/48/50

44/48/50

48/50/53

Sound power (l/m/h)

dB(A)

44/47/50

47/49/53

49/50/52

49/52/57

52/55/61

55/59/61

55/59/61

59/61/64

Dimensions (HxLxD)

mm

540x850x200

540x850x200

Weight
Power Supply

kg

15

16

18

18

20

35

35

36

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

09

12

14

18

24

28

36

48

8 sizes in cooling only and heat pump capacities from: 2,69kW to 10,10kW in cooling;
2,94kW to 10,9kW in heating.

rotary

rotary

rotary

rotary

rotary

scroll

scroll

scroll

15

15

15

30

40

40

50

50

Compressor Type

Air flow (CO/HP)


Sound pressure (CO/HP)
Sound power (CO/HP)
Dimensions (HxLxD) (CO)

598x1000x200 598x1000x200 598x1000x200 610x1200x225 610x1200x225 610x1200x225

15

15

25

30

30

10

10

10

m3/h

1540

1540

1540

1900/2400

1900/2600

2400

2400/3100

4900/4200

38 / 38

38 / 38

40 / 40

45 / 46

45 / 49

48 / 48

49 / 52

53 / 54

Award from the Italian Association of Industrial Design (ADI).

dB(A)

58 / 58

58 / 58

60 / 60

65 / 66

65 / 69

68 / 68

69 / 72

73 / 74

mm

590x750x280

590x750x280

590x750x280

590x800x300

590x800x300

803x800x300

803x800x300

1264x800x300

Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 m. Filter can be washed and regenerated in sunlight.

kg

30

33

35

45

51

65

65

92

Dimensions (HxLxD) (HP)

mm

590x750x280

590x750x280

590x750x280

590x800x300

803x800x300

803x800x300

803x800x300

1264x800x300

Flare Connections
Starting current
Power Supply
*
**

FEATURES

dB(A)**

Weight (CO)
Weight (HP)

42VMC_N - CONSOLE UNITS


Carrier console units are slim and stylish, making many conventional air
conditioning units look old-fashioned in comparison. A versatile solution,
designed for installation on a wall or under the ceiling.

Outdoor unit
Maximum pipe length (CO/HP)
Maximum height difference
(CO/HP)
Chargeless pipe length (CO/HP)

Stylish design for modern interiors.

kg

33

36

37

47

60

67

68

94

inch

3/8 - 1/4

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

5/8 - 1/4

3/4 - 3/8

3/4 - 3/8

17

24

28

50

56

37

39

54

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

400-3-50

400-3-50

400-3-50

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4 m.

Motorised louvre allows air distribution direction according to individual preferences.


MyComfort remote control function memorises the preferred user settings.
State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet.

42VMC_N FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 42VMC_N

42 VMC-N Console & Underceiling

CONTROLS

Freedom of choice between infrared remote


control and wired controls.

ACCESSORIES
Condensate discharge pump
Hot water coil kit
Piping cover kit
Electric heater

Fits under a window sill. Reduced footprint and compact overall dimensions for
a wide choice of installation solutions.
All key components are easily accessible through the grille without removing
the front panel.

OUTDOOR UNITS

Monosplit: 38BC/BH and 38GL/YY


Multisplit: 38GL_M/YL_M

38

39

40KMC_N - CASSETTE UNITS


FIXED SPEED SPLIT SYSTEM
40KMC-N Cassette
Indoor unit

40KMC012-7N

40KMC018-7N

40KMC024-7N

40KMC028-7N

40KMC036-7N

40KMC048-7N

40KMC060-7N

38BC-012G

38GL-018G

38GL-024G

38GL-028G9

38GL-036G9

38GL-048G9

38GL-060G9

Cooling capacity (CO)

kW

3,58

5,59

6,1

8,28

10,9

13,6

Power input (CO)

1240

2180

2460

2880

3320

3540

4900

W/W

2,89

2,56

2,48

2,88

2,71

3,08

2,78

na

620

1090

1230

1440

1660

1770

12

18

24

28

36

48

60

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

Outdoor unit (HP)


Cooling capacity (CO)

kW

3,52

4,92

6,23

7,86

8,74

10,92

12,4

Power input (CO)

1160

2000

2790

3100

3470

3540

5220

W/W

3,03

2,46

2,23

2,54

2,52

3,08

2,38

na

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

580

1000

1395

1550

1735

1770

Heating capacity

kW

3,78

5,38

7,02

8,03

8,94

10,87

13,24

1280

2160

2780

2640

2960

3490

4620

W/W

2,95

2,49

2,53

3,04

3,02

3,11

2,87

na

Power input (HP)


COP
Energy efficiency class (HP)
Indoor unit

12

18

24

28

36

48

60

1,5

1,5+1,0

1,5+1,0

2,0+1,0

2,0+1,0

2,0+1,0

2,0+1,0

Electric heater

kW

Dehumidification

l/h

0,8

1,9

2,5

3,0

3,5

4,6

5,2

Air flow (l/m/h)

l/s

152/167/183

156/175/194

189/213/250

200/250/300

270/305/350

320/390/460

400/470/515

Sound pressure (l/m/h)

dB(A)*

27/31/34

30/33/36

35/38/42

29/32/36

33/36/39

37/42/45

43/46/49

Sound power (l/m/h)

dB(A)

40/44/47

43/46/49

48/51/55

42/45/49

46/49/52

50/55/58

56/59/62

Dimensions (HxLxD)

mm

298/575/575

298/575/575

298/575/575

298/825/825

298/825/825

298/825/825

298/825/825

Weight

kg

17,5

19

19

36,0

38,0

38,0

41

Grille Dimensions(HxLxD)

mm

30/720/720

30/720/720

30/720/720

30/960/960

30/960/960

30/960/960

30/960/960

Grille weight

kg

2,5

2,5

2,5

5,0

5,0

5,0

Power Supply

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

Outdoor unit
Compressor Type

12

18

24

28

36

48

60

rotary

rotary

rotary

rotary

scroll

scroll

scroll

Maximum pipe length (CO/HP)

15

30

40

40

50

50

50

Maximum height difference (CO/HP)

15

15

25

30

30

30

Chargeless pipe length (CO/HP)

10

m3/h

1540

1900/2400

1900/2600

2400

2400/3100

4900/4200

4900/4200

dB(A)**

38 / 38

45 / 46

45 / 49

48 / 48

49 / 52

53 / 54

52 / 53

dB(A)

58 / 58

65 / 66

65 / 69

68 / 68

69 / 72

73 / 74

72 / 73

Dimensions (HxLxD) (CO)

mm

590x750x280

590x800x300

590x800x300

803x800x300

803x800x300

1264x800x300

1264x800x300

Weight (CO)

kg

33

45

51

65

65

92

94

Dimensions (HxLxD) (HP)

mm

590x750x280

590x800x300

803x800x300

803x800x300

803x800x300

1264x800x300

1264x800x300

Air flow (CO/HP)


Sound pressure (CO/HP)
Sound power (CO/HP)

Weight (HP)
Flare Connections
Starting current
Power Supply
*
**

kg

36

47

60

67

68

94

96

inch

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

5/8 - 1/4

3/4 - 3/8

3/4 - 3/8

3/4 - 3/8

28

50

56

37

39

54

64

V-ph-Hz

230-1-50

230-1-50

230-1-50

400-3-50

400-3-50

400-3-50

400-3-50

The patented wing-shaped centrifugal fan, new


heat exchanger and improved air management
system ensure near-perfect acoustic performance.

40KMC_N FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 40KMC_N

Outdoor unit (CO)

40KMC_N - CASSETTE UNITS


If you need a system with the right combination of performance, style and
flexibility, the Carrier cassette is the natural choice.

CONTROLS

7 sizes in cooling only and heat pump capacities from: 3,58kW to 13,6kW in cooling;
3,78kW to 13,24kW in heating.

FEATURES
Standard dimensions compatible with all suspended ceiling systems in common
use in shops and offices.
Award from the Italian Association of Industrial Design (ADI).
Simply opening the grille gives access to all critical components.
Fresh air intake and additional outlet grille allow air conditioning of an adjoining
room.
Two, three and four-way motorised louvres allow air flow direction according to
individual preferences.

Freedom of choice between infrared remote


control and wired controls.

ACCESSORIES
Air4Life kit: photo-catalytic titanium and electrostatic filters
Air supply outlet obstruction kit
Electric heater

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4 m.

OUTDOOR UNITS

Monosplit: 38BC/BH and 38GL/YY


Multisplit: 38GL_M/YL_M

40

41

40KMC_N - CASSETTE UNITS


FIXED SPEED SPLIT SYSTEM
40KMC-N Cassette
Indoor unit

40KMC012-7N

40KMC018-7N

40KMC024-7N

40KMC028-7N

40KMC036-7N

40KMC048-7N

40KMC060-7N

38BC-012G

38GL-018G

38GL-024G

38GL-028G9

38GL-036G9

38GL-048G9

38GL-060G9

Cooling capacity (CO)

kW

3,58

5,59

6,1

8,28

10,9

13,6

Power input (CO)

1240

2180

2460

2880

3320

3540

4900

W/W

2,89

2,56

2,48

2,88

2,71

3,08

2,78

na

620

1090

1230

1440

1660

1770

12

18

24

28

36

48

60

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

Outdoor unit (HP)


Cooling capacity (CO)

kW

3,52

4,92

6,23

7,86

8,74

10,92

12,4

Power input (CO)

1160

2000

2790

3100

3470

3540

5220

W/W

3,03

2,46

2,23

2,54

2,52

3,08

2,38

na

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

580

1000

1395

1550

1735

1770

Heating capacity

kW

3,78

5,38

7,02

8,03

8,94

10,87

13,24

1280

2160

2780

2640

2960

3490

4620

W/W

2,95

2,49

2,53

3,04

3,02

3,11

2,87

na

Power input (HP)


COP
Energy efficiency class (HP)
Indoor unit

12

18

24

28

36

48

60

1,5

1,5+1,0

1,5+1,0

2,0+1,0

2,0+1,0

2,0+1,0

2,0+1,0

Electric heater

kW

Dehumidification

l/h

0,8

1,9

2,5

3,0

3,5

4,6

5,2

Air flow (l/m/h)

l/s

152/167/183

156/175/194

189/213/250

200/250/300

270/305/350

320/390/460

400/470/515

Sound pressure (l/m/h)

dB(A)*

27/31/34

30/33/36

35/38/42

29/32/36

33/36/39

37/42/45

43/46/49

Sound power (l/m/h)

dB(A)

40/44/47

43/46/49

48/51/55

42/45/49

46/49/52

50/55/58

56/59/62

Dimensions (HxLxD)

mm

298/575/575

298/575/575

298/575/575

298/825/825

298/825/825

298/825/825

298/825/825

Weight

kg

17,5

19

19

36,0

38,0

38,0

41

Grille Dimensions(HxLxD)

mm

30/720/720

30/720/720

30/720/720

30/960/960

30/960/960

30/960/960

30/960/960

Grille weight

kg

2,5

2,5

2,5

5,0

5,0

5,0

Power Supply

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

Outdoor unit
Compressor Type

12

18

24

28

36

48

60

rotary

rotary

rotary

rotary

scroll

scroll

scroll

Maximum pipe length (CO/HP)

15

30

40

40

50

50

50

Maximum height difference (CO/HP)

15

15

25

30

30

30

Chargeless pipe length (CO/HP)

10

m3/h

1540

1900/2400

1900/2600

2400

2400/3100

4900/4200

4900/4200

dB(A)**

38 / 38

45 / 46

45 / 49

48 / 48

49 / 52

53 / 54

52 / 53

dB(A)

58 / 58

65 / 66

65 / 69

68 / 68

69 / 72

73 / 74

72 / 73

Dimensions (HxLxD) (CO)

mm

590x750x280

590x800x300

590x800x300

803x800x300

803x800x300

1264x800x300

1264x800x300

Weight (CO)

kg

33

45

51

65

65

92

94

Dimensions (HxLxD) (HP)

mm

590x750x280

590x800x300

803x800x300

803x800x300

803x800x300

1264x800x300

1264x800x300

Air flow (CO/HP)


Sound pressure (CO/HP)
Sound power (CO/HP)

Weight (HP)
Flare Connections
Starting current
Power Supply
*
**

kg

36

47

60

67

68

94

96

inch

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

5/8 - 1/4

3/4 - 3/8

3/4 - 3/8

3/4 - 3/8

28

50

56

37

39

54

64

V-ph-Hz

230-1-50

230-1-50

230-1-50

400-3-50

400-3-50

400-3-50

400-3-50

The patented wing-shaped centrifugal fan, new


heat exchanger and improved air management
system ensure near-perfect acoustic performance.

40KMC_N FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 40KMC_N

Outdoor unit (CO)

40KMC_N - CASSETTE UNITS


If you need a system with the right combination of performance, style and
flexibility, the Carrier cassette is the natural choice.

CONTROLS

7 sizes in cooling only and heat pump capacities from: 3,58kW to 13,6kW in cooling;
3,78kW to 13,24kW in heating.

FEATURES
Standard dimensions compatible with all suspended ceiling systems in common
use in shops and offices.
Award from the Italian Association of Industrial Design (ADI).
Simply opening the grille gives access to all critical components.
Fresh air intake and additional outlet grille allow air conditioning of an adjoining
room.
Two, three and four-way motorised louvres allow air flow direction according to
individual preferences.

Freedom of choice between infrared remote


control and wired controls.

ACCESSORIES
Air4Life kit: photo-catalytic titanium and electrostatic filters
Air supply outlet obstruction kit
Electric heater

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4 m.

OUTDOOR UNITS

Monosplit: 38BC/BH and 38GL/YY


Multisplit: 38GL_M/YL_M

40

41

40SMC_N - SATELLITE UNITS

Indoor unit

40SMC009N

40SMC012N

40SMC018N

Outdoor unit (CO)

38BC-009G

38BC-012G

38GL-018G

Cooling capacity (CO)

kW

2,71

3,41

5,09

Power input (CO)

1030

1250

2300

W/W

2,63

2,73

2,21

kWh

515

625

1150

09

12

18

kW

2,64

3,35

5,11

950

1170

2180

W/W

2,78

2,86

2,34

475

585

1090

EER
Energy efficiency class (CO)
Annual energy consumption
Outdoor unit (HP)
Cooling capacity (CO)
Power input (CO)
EER
Energy efficiency class (CO)
Annual energy consumption

kWh

Heating capacity

kW

3,2

3,76

5,44

Power input (HP)

980

1250

2170

W/W

3,27

3,01

2,51

COP
Energy efficiency class (HP)
Indoor unit

09

12

18

Dehumidification

l/h

0,5

0,8

1,9

Air flow (l/m/h)

l/s

92/103/133

103/118/139

126/149/182

Static Pressure

Pa

33

40

45

Sound pressure (l/m/h)

dB(A)*

42/43/44

42/44/45

43/45/47

Sound power (l/m/h)

dB(A)

55/56/57

56/57/58

56/58/60

Dimensions (HxLxD)

mm

220x725x555

220x725x555

220x725x555

Weight
Power Supply

kg

23

23

23

V-ph-Hz

230-1-50

230-1-50

230-1-50

Outdoor unit
Compressor Type

09

12

18

rotary

rotary

rotary

Maximum pipe length (CO/HP)

15

15

30

Maximum height difference (CO/HP)

15

Chargeless pipe length (CO/HP)

10

10

Air flow (CO/HP)

m3/h

1540

1540

1900/2400

dB(A)**

38 / 38

38 / 38

45 / 46

dB(A)

58 / 58

58 / 58

65 / 66

Dimensions (HxLxD) (CO)

mm

590x750x280

590x750x280

590x800x300

Weight (CO)

kg

30

33

45

Dimensions (HxLxD) (HP)

mm

590x750x280

590x750x280

590x800x300

Sound pressure (CO/HP)


Sound power (CO/HP)

Weight (HP)
Flare Connections
Starting current
Power Supply
*
**

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4 m.

kg

33

36

47

inch

3/8 - 1/4

1/2 - 1/4

1/2 - 1/4

24

28

50

V-ph-Hz

230-1-50

230-1-50

230-1-50

Installation flexibility with a wide range of


accessories.

40SMC_N - SATELLITE UNITS


With its compact size and flexibility the Carrier 40SMC ducted system is the
ideal choice for both new and refurbished buildings.

40SMC_N FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 40SMC_N

FIXED SPEED SPLIT SYSTEM

CONTROLS

8 sizes in cooling only and heat pump capacities from: 2,71kW to 13,6kW in cooling;
3,2kW to 14,00kW in heating.

FEATURES
The preferred solution for consultants and installers - quick and easy to install,
compatible with existing electrical and plumbing systems.
Ducted system - the ideal choice for both new and refurbished houses.
Filters, coils, motors and valves are easily accessible by removing only a few
screws.
Powerful three-speed direct-drive fan delivers air at up to 80 Pa external static
pressure.
Unique slim-line profile - the low unit height permits installation even in low ceilings.
Compact and 30% lighter than other ducted units on the market.

Freedom of choice between infrared remote


control and wired controls.

ACCESSORIES
Electric heater.
Hot water coil and anti-freeze thermostat.
Mixing box for fresh air.
Suction plenum.
Discharge plenum.
Octopus - two, three or four outlets.
High-efficiency gravimetric filter.
3-way, 4-connection valve for hot water coil.
MyComfort infrared control kit.

OUTDOOR UNITS

Monosplit: 38BC/BH and 38GL/YY


Multisplit: 38GL_M/YL_M

42

43

40SMC_N - SATELLITE UNITS

Indoor unit

40SMC009N

40SMC012N

40SMC018N

Outdoor unit (CO)

38BC-009G

38BC-012G

38GL-018G

Cooling capacity (CO)

kW

2,71

3,41

5,09

Power input (CO)

1030

1250

2300

W/W

2,63

2,73

2,21

kWh

515

625

1150

09

12

18

kW

2,64

3,35

5,11

950

1170

2180

W/W

2,78

2,86

2,34

475

585

1090

EER
Energy efficiency class (CO)
Annual energy consumption
Outdoor unit (HP)
Cooling capacity (CO)
Power input (CO)
EER
Energy efficiency class (CO)
Annual energy consumption

kWh

Heating capacity

kW

3,2

3,76

5,44

Power input (HP)

980

1250

2170

W/W

3,27

3,01

2,51

COP
Energy efficiency class (HP)
Indoor unit

09

12

18

Dehumidification

l/h

0,5

0,8

1,9

Air flow (l/m/h)

l/s

92/103/133

103/118/139

126/149/182

Static Pressure

Pa

33

40

45

Sound pressure (l/m/h)

dB(A)*

42/43/44

42/44/45

43/45/47

Sound power (l/m/h)

dB(A)

55/56/57

56/57/58

56/58/60

Dimensions (HxLxD)

mm

220x725x555

220x725x555

220x725x555

Weight
Power Supply

kg

23

23

23

V-ph-Hz

230-1-50

230-1-50

230-1-50

Outdoor unit
Compressor Type

09

12

18

rotary

rotary

rotary

Maximum pipe length (CO/HP)

15

15

30

Maximum height difference (CO/HP)

15

Chargeless pipe length (CO/HP)

10

10

Air flow (CO/HP)

m3/h

1540

1540

1900/2400

dB(A)**

38 / 38

38 / 38

45 / 46

dB(A)

58 / 58

58 / 58

65 / 66

Dimensions (HxLxD) (CO)

mm

590x750x280

590x750x280

590x800x300

Weight (CO)

kg

30

33

45

Dimensions (HxLxD) (HP)

mm

590x750x280

590x750x280

590x800x300

Sound pressure (CO/HP)


Sound power (CO/HP)

Weight (HP)
Flare Connections
Starting current
Power Supply
*
**

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4 m.

kg

33

36

47

inch

3/8 - 1/4

1/2 - 1/4

1/2 - 1/4

24

28

50

V-ph-Hz

230-1-50

230-1-50

230-1-50

Installation flexibility with a wide range of


accessories.

40SMC_N - SATELLITE UNITS


With its compact size and flexibility the Carrier 40SMC ducted system is the
ideal choice for both new and refurbished buildings.

40SMC_N FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 40SMC_N

FIXED SPEED SPLIT SYSTEM

CONTROLS

8 sizes in cooling only and heat pump capacities from: 2,71kW to 13,6kW in cooling;
3,2kW to 14,00kW in heating.

FEATURES
The preferred solution for consultants and installers - quick and easy to install,
compatible with existing electrical and plumbing systems.
Ducted system - the ideal choice for both new and refurbished houses.
Filters, coils, motors and valves are easily accessible by removing only a few
screws.
Powerful three-speed direct-drive fan delivers air at up to 80 Pa external static
pressure.
Unique slim-line profile - the low unit height permits installation even in low ceilings.
Compact and 30% lighter than other ducted units on the market.

Freedom of choice between infrared remote


control and wired controls.

ACCESSORIES
Electric heater.
Hot water coil and anti-freeze thermostat.
Mixing box for fresh air.
Suction plenum.
Discharge plenum.
Octopus - two, three or four outlets.
High-efficiency gravimetric filter.
3-way, 4-connection valve for hot water coil.
MyComfort infrared control kit.

OUTDOOR UNITS

Monosplit: 38BC/BH and 38GL/YY


Multisplit: 38GL_M/YL_M

42

43

40DMC - SATELLITE UNITS


FIXED SPEED SPLIT SYSTEM

Indoor unit

40DMC018

40DMC024

40DMC028

40DMC036

40DMC036

40DMC052

40DMC060

Outdoor unit (CO)

38GL-018G

38GL-024G

38GL-028G9

38GL-036G9

38GL-048G9

38GL-052G9

38GL-060G9

Cooling capacity (CO)

kW

5,40

6,48

8,12

8,48

9,78

11,60

13,49

Power input (CO)

2151

2763

3022

3201

3085

4319

4797

W/W

2,51

2,34

2,69

2,65

3,17

2,69

2,81

na

1075

1381

1511

1600

1542

2160

38YY-018G

38YY-024G

38YY-028G9

38YY-036G9

38YY048G9

38YY0-052G9

38YY-060G9

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

Outdoor unit (HP)


Cooling capacity (CO)

kW

5,42

6,63

8,12

8,63

10,19

12,03

13,77

Power input (CO)

2038

2670

3040

3339

3453

4282

5041

W/W

2,66

2,48

2,67

2,59

2,95

2,81

2,73

na

na

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

1019

1335

1520

1669

1726

Heating capacity

kW

5,64

7,02

8,22

9,44

11,02

13,28

14,50

Power input (HP)

1828

2444

2278

2551

3358

4166

4110

W/W

3,09

2,87

3,61

3,70

3,28

3,19

3,53

na

na

COP
Energy efficiency class (HP)
Indoor unit

18

24

28

36

48

52

60

l/h

1,6

2,0

2,3

2,0

3,1

3,8

4,0

Nominal air flow (l/m/h)

l/s

210/263/294

205/211/269

244/318/383

291/380/463

291/380/463

390/476/564

569/616/667

Nominal static pressure

Pa

50

50

50

80

80

80

80

Sound pressure level (l/m/h)

dB(A)*

39/40/42

38/40/42

40/43/46

44/46/49

44/46/49

46/49/54

47/51/54

Sound power level (l/m/h)

dB(A)

52/53/55

51/53/55

53/56/59

57/59/64

57/59/64

59/62/67

60/64/67

mm

925x750x285

925x750x285

925x750x285

1325x750x285

1325x750x285

1325x750x285

1325x750x285

Dehumidification

Dimensions (H x L x D)
Weight
Power Supply

kg

32

35

35

48

48

48

53

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

Outdoor unit (CO/HP)


Compressor Type

18

24

28

36

48

52

60

rotary

rotary

scroll

scroll

scroll

scroll

scroll

Maximum pipe length

30

40

40

50

50

50

50

Maximum height difference

15

15

25

30

30

30

30

Chargeless length

Air flow

l/s

667

528

667

667

1361

1361

1361

dB(A)**

45/46

45/49

48/48

49/52

53/54

53/54

52/53

Sound power level (CO/HP)

dB(A)

65/66

65/69

68/68

69/72

73/74

73/74

72/73

Dimensions (H x L x D) (CO)

mm

590x800x300

590x800x300

803x800x300

803x800x300

1264x800x300

1264x800x300

1264x800x300

Sound pressure level (CO/HP)

Weight (CO)

kg

45

51

65

65

92

94

94

Dimensions (H x L x D) (HP)

mm

590x800x300

803x800x300

803x800x300

803x800x300

1264x800x300

1264x800x300

1264x800x300

Weight (HP)

kg

47

60

67

68

94

96

96

inch

1/2 - 1/4

1/2 - 1/4

5/8 - 1/4

3/4 - 3/8

3/4 - 3/8

3/4 - 3/8

3/4 - 3/8

50

56

37

39

54

64

64

V-ph-Hz

230-1-50

230-1-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

Flare Connections
Starting current
Power Supply
*
**

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4 m.

285

Ultra-slim profile - only 285 mm for all sizes,


thanks to the Carrier-patented V-shaped coil.

40DMC - SATELLITE UNITS

40DMC FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 40DMC

40DMC Satellite

CONTROLS

The new ducted above-ceiling units from Carrier represent a breakthrough


in design terms. The slimmest profile ever and flexible installation options
make these units the best choice for homes and small commercial premises.
7 sizes in cooling only and heat pump capacities from: 5,49kW to 13,4kW in cooling;
5,31kW to 14,55kW in heating.

FEATURES
Designed for front or side air discharge.
Unique design with lateral air discharge allows the unit to be installed in a corridor.
Modular filter and panel sizes allow flexible unit mounting with rear or bottom
air return.
Equipped with pre-punched 150-mm diameter fresh air intakes on both sides,
and with pre-punched Octopus discharge panel.

Freedom of choice between infrared remote control and wired controls.

ACCESSORIES
Hot water coil.
Electric heater.
MyComfort infrared control kit.

Control box equipped with 1.5-m cable for flexible positioning and accessibility.
Both electric heater and hot water coil are retrofit outside the unit for easy
mounting on installed units.

OUTDOOR UNITS

Monosplit: 38BC/BH and 38GL/YY


Multisplit: 38GL_M/YL_M

44

45

40DMC - SATELLITE UNITS


FIXED SPEED SPLIT SYSTEM

Indoor unit

40DMC018

40DMC024

40DMC028

40DMC036

40DMC036

40DMC052

40DMC060

Outdoor unit (CO)

38GL-018G

38GL-024G

38GL-028G9

38GL-036G9

38GL-048G9

38GL-052G9

38GL-060G9

Cooling capacity (CO)

kW

5,40

6,48

8,12

8,48

9,78

11,60

13,49

Power input (CO)

2151

2763

3022

3201

3085

4319

4797

W/W

2,51

2,34

2,69

2,65

3,17

2,69

2,81

na

1075

1381

1511

1600

1542

2160

38YY-018G

38YY-024G

38YY-028G9

38YY-036G9

38YY048G9

38YY0-052G9

38YY-060G9

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

Outdoor unit (HP)


Cooling capacity (CO)

kW

5,42

6,63

8,12

8,63

10,19

12,03

13,77

Power input (CO)

2038

2670

3040

3339

3453

4282

5041

W/W

2,66

2,48

2,67

2,59

2,95

2,81

2,73

na

na

EER
Energy efficiency class (CO)
Annual energy consumption

kWh

1019

1335

1520

1669

1726

Heating capacity

kW

5,64

7,02

8,22

9,44

11,02

13,28

14,50

Power input (HP)

1828

2444

2278

2551

3358

4166

4110

W/W

3,09

2,87

3,61

3,70

3,28

3,19

3,53

na

na

COP
Energy efficiency class (HP)
Indoor unit

18

24

28

36

48

52

60

l/h

1,6

2,0

2,3

2,0

3,1

3,8

4,0

Nominal air flow (l/m/h)

l/s

210/263/294

205/211/269

244/318/383

291/380/463

291/380/463

390/476/564

569/616/667

Nominal static pressure

Pa

50

50

50

80

80

80

80

Sound pressure level (l/m/h)

dB(A)*

39/40/42

38/40/42

40/43/46

44/46/49

44/46/49

46/49/54

47/51/54

Sound power level (l/m/h)

dB(A)

52/53/55

51/53/55

53/56/59

57/59/64

57/59/64

59/62/67

60/64/67

mm

925x750x285

925x750x285

925x750x285

1325x750x285

1325x750x285

1325x750x285

1325x750x285

Dehumidification

Dimensions (H x L x D)
Weight
Power Supply

kg

32

35

35

48

48

48

53

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

Outdoor unit (CO/HP)


Compressor Type

18

24

28

36

48

52

60

rotary

rotary

scroll

scroll

scroll

scroll

scroll

Maximum pipe length

30

40

40

50

50

50

50

Maximum height difference

15

15

25

30

30

30

30

Chargeless length

Air flow

l/s

667

528

667

667

1361

1361

1361

dB(A)**

45/46

45/49

48/48

49/52

53/54

53/54

52/53

Sound power level (CO/HP)

dB(A)

65/66

65/69

68/68

69/72

73/74

73/74

72/73

Dimensions (H x L x D) (CO)

mm

590x800x300

590x800x300

803x800x300

803x800x300

1264x800x300

1264x800x300

1264x800x300

Sound pressure level (CO/HP)

Weight (CO)

kg

45

51

65

65

92

94

94

Dimensions (H x L x D) (HP)

mm

590x800x300

803x800x300

803x800x300

803x800x300

1264x800x300

1264x800x300

1264x800x300

Weight (HP)

kg

47

60

67

68

94

96

96

inch

1/2 - 1/4

1/2 - 1/4

5/8 - 1/4

3/4 - 3/8

3/4 - 3/8

3/4 - 3/8

3/4 - 3/8

50

56

37

39

54

64

64

V-ph-Hz

230-1-50

230-1-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

Flare Connections
Starting current
Power Supply
*
**

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4 m.

285

Ultra-slim profile - only 285 mm for all sizes,


thanks to the Carrier-patented V-shaped coil.

40DMC - SATELLITE UNITS

40DMC FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 40DMC

40DMC Satellite

CONTROLS

The new ducted above-ceiling units from Carrier represent a breakthrough


in design terms. The slimmest profile ever and flexible installation options
make these units the best choice for homes and small commercial premises.
7 sizes in cooling only and heat pump capacities from: 5,49kW to 13,4kW in cooling;
5,31kW to 14,55kW in heating.

FEATURES
Designed for front or side air discharge.
Unique design with lateral air discharge allows the unit to be installed in a corridor.
Modular filter and panel sizes allow flexible unit mounting with rear or bottom
air return.
Equipped with pre-punched 150-mm diameter fresh air intakes on both sides,
and with pre-punched Octopus discharge panel.

Freedom of choice between infrared remote control and wired controls.

ACCESSORIES
Hot water coil.
Electric heater.
MyComfort infrared control kit.

Control box equipped with 1.5-m cable for flexible positioning and accessibility.
Both electric heater and hot water coil are retrofit outside the unit for easy
mounting on installed units.

OUTDOOR UNITS

Monosplit: 38BC/BH and 38GL/YY


Multisplit: 38GL_M/YL_M

44

45

FB4X - VERTICAL DUCTED


FIXED SPEED SPLIT SYSTEM

Indoor Units

FX4CSX024

FX4CSX036

FX4CSX048

FX4CSX060

Outdoor units

38EYX024-7

38EYX036-9

38EYX048-9

38EYX060-9

Cooling capacity

kW

6,8

10,0

13,7

16,7

Nominal power input (CO)

kW

2,12

3,14

4,36

5,87

Annual Energy Consumption

kW/h

1060

1570

na

na

EER

W/W

3,22

3,18

3,13

2,85

Energy efficiency class (CO)

kW

na

na

Heating capacity

kW

6,64

10,39

14,48

17,07

Nominal power input (HP)

kW

1,83

2,98

3,82

5,04

W/W

3,63

3,49

3,79

3,39

kW

na

na

COP
Energy efficiency class HP
INDOOR UNITS (FURNACE TYPE)

24

36

48

60

l/h

3,4

4,6

7,0

8,2

Nominal air flow

l/s

475

600

750

825

Maximum static pressure

Pa

125

125

125

125

dB(A)

72

77

77

80

dB(A)***

56

61

61

64

Dimensions (HxWxD)

mm

1212x448x560

1357x537x560

1261x537x560

1357x537x560

Weight

kg

55

67

72

80

Dehumidification

Sound power
Sound pressure

HEAT PUMP CONDENSING UNITS

24

36

48

60

Compressor type

scroll

scroll

scroll

scroll

Refrigerant type

R-410A

R-410A

R-410A

R-410A

50

50

50

50

Maximum pipe lenght


Maximum elevation
Chargeless piping lenght
Additional refrigerant charge
Sound power

m
m*

45

45

45

45

4,5

4,5

4,5

4,5

g/m

56

56

56

56

dB(A)

72

72

72

74

Sound pressure

dB(A)**

52

52

52

54

Nominal air flow

l/s

708

1274

1416

1180

Dimensions (HxWxD)

mm

761x572x572

761x762x762

1015x762x762

862x762x762

Weight

kg

65,8

83,9

99,3

111,6

Sweat connections (liquid/gas)

in

3/8 - 5/8

3/8 - 3/4

3/8 - 7/8

3/8 - 7/8

Maximum running current

16,2

8,7

12,0

14,0

Installation fuse rating

25

15

20

20

Nominal power supply

V-ph-Hz

230-1-50

400-3-50

400-3-50

400-3-50

(*) : If the CDU is positioned below the IDU, the maximum elevation is 15meters
(**) : sound pressure level measured in hemispheric field at 4m distance from the unit
(***) : sound pressure level measured in anechoic room at 1,28m from discharge outlet on vertical wall

TECH3000

Exceptional installation flexibility - the indoor


unit can be installed in three air flow positions:
upwards, downwards or horizontal.

FB4X - VERTICAL DUCTED


Encased indoor fan coils, complete with direct-expansion indoor coil, suitable for use in cooling only and heat pump systems.

FB4X FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM FB4X

FB4X

CONTROLS

4 size in cooling only and heat pump.

FEATURES
Room thermostat

All materials used are designed and protected to resist the toughest climates.
Refrigerant circuit service valves with easily accessible pressure test ports for
start-up and maintenance.
Heat pump cycle with four-position valve (38EYX); electronic control system for
optimised defrosting.
High and low-pressure safety switches fitted as standard.

ACCESSORIES
Downflow Convertion Kit
Downflow / Horizontal Kit
Filter Kit

To assure long life and reliability outdoor unit compressors are hermetically
sealed against contamination and pollutants.

OUTDOOR UNIT

38EYX

46

47

FB4X - VERTICAL DUCTED


FIXED SPEED SPLIT SYSTEM

Indoor Units

FX4CSX024

FX4CSX036

FX4CSX048

FX4CSX060

Outdoor units

38EYX024-7

38EYX036-9

38EYX048-9

38EYX060-9

Cooling capacity

kW

6,8

10,0

13,7

16,7

Nominal power input (CO)

kW

2,12

3,14

4,36

5,87

Annual Energy Consumption

kW/h

1060

1570

na

na

EER

W/W

3,22

3,18

3,13

2,85

Energy efficiency class (CO)

kW

na

na

Heating capacity

kW

6,64

10,39

14,48

17,07

Nominal power input (HP)

kW

1,83

2,98

3,82

5,04

W/W

3,63

3,49

3,79

3,39

kW

na

na

COP
Energy efficiency class HP
INDOOR UNITS (FURNACE TYPE)

24

36

48

60

l/h

3,4

4,6

7,0

8,2

Nominal air flow

l/s

475

600

750

825

Maximum static pressure

Pa

125

125

125

125

dB(A)

72

77

77

80

dB(A)***

56

61

61

64

Dimensions (HxWxD)

mm

1212x448x560

1357x537x560

1261x537x560

1357x537x560

Weight

kg

55

67

72

80

Dehumidification

Sound power
Sound pressure

HEAT PUMP CONDENSING UNITS

24

36

48

60

Compressor type

scroll

scroll

scroll

scroll

Refrigerant type

R-410A

R-410A

R-410A

R-410A

50

50

50

50

Maximum pipe lenght


Maximum elevation
Chargeless piping lenght
Additional refrigerant charge
Sound power

m
m*

45

45

45

45

4,5

4,5

4,5

4,5

g/m

56

56

56

56

dB(A)

72

72

72

74

Sound pressure

dB(A)**

52

52

52

54

Nominal air flow

l/s

708

1274

1416

1180

Dimensions (HxWxD)

mm

761x572x572

761x762x762

1015x762x762

862x762x762

Weight

kg

65,8

83,9

99,3

111,6

Sweat connections (liquid/gas)

in

3/8 - 5/8

3/8 - 3/4

3/8 - 7/8

3/8 - 7/8

Maximum running current

16,2

8,7

12,0

14,0

Installation fuse rating

25

15

20

20

Nominal power supply

V-ph-Hz

230-1-50

400-3-50

400-3-50

400-3-50

(*) : If the CDU is positioned below the IDU, the maximum elevation is 15meters
(**) : sound pressure level measured in hemispheric field at 4m distance from the unit
(***) : sound pressure level measured in anechoic room at 1,28m from discharge outlet on vertical wall

TECH3000

Exceptional installation flexibility - the indoor


unit can be installed in three air flow positions:
upwards, downwards or horizontal.

FB4X - VERTICAL DUCTED


Encased indoor fan coils, complete with direct-expansion indoor coil, suitable for use in cooling only and heat pump systems.

FB4X FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM FB4X

FB4X

CONTROLS

4 size in cooling only and heat pump.

FEATURES
Room thermostat

All materials used are designed and protected to resist the toughest climates.
Refrigerant circuit service valves with easily accessible pressure test ports for
start-up and maintenance.
Heat pump cycle with four-position valve (38EYX); electronic control system for
optimised defrosting.
High and low-pressure safety switches fitted as standard.

ACCESSORIES
Downflow Convertion Kit
Downflow / Horizontal Kit
Filter Kit

To assure long life and reliability outdoor unit compressors are hermetically
sealed against contamination and pollutants.

OUTDOOR UNIT

38EYX

46

47

38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS


FIXED SPEED SPLIT SYSTEM

Flare connections [A]

inch

38GL2M12G
Rotary
Shared

15
5
15
331
43
63
590x660x250
39
2
3/8 - 1/4
1/2 - 1/4

Flare connections [B]

inch

3/8 - 1/4

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

3/8 - 1/4

3/8 - 1/4

A
V-ph-Hz

30
230-1-50

30 + 30
230-1-50

30 + 30
230-1-50

50 + 50
230-1-50

60 + 60
230-1-50

30 + 30
230-1-50

30 + 50
230-1-50

38YY2M18G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15/15
167
45
65
590x800x300
55
2
3/8 - 1/4
3/8 - 1/4
25 + 25
230-1-50

38YY2M21G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15/15
210
48
68
803x800x300
61
2
1/2 - 1/4
1/2 - 1/4
25 + 30
230-1-50

Starting current
Power Supply

Outdoor unit (HP)


Compressor Type
Compressor [A]
Compressor [B]
Maximum pipe length
Maximum height difference
Chargeless length
Additional charge
Air flow
Sound pressure level*
Sound power level
Dimensions (H x L x D)
Weight
Max. number of indoor units
Flare connections [A]
Flare connections [B]
Starting current
Power Supply
*

[A]
[B]
m
m
m
g/m
l/s
dB(A)
dB(A)
mm
kg

m
m
m
g/m
l/s
dB(A)
dB(A)
mm
kg
inch
inch
A
V-ph-Hz

38GL2M18G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15
533
45
65
590x800x300
55
2
3/8 - 1/4

38GL2M24G 38GL2M36G 38GL2M48G 38GL3M21G


Rotary
Rotary
Rotary
Rotary
dedicated
dedicated
dedicated
shared
dedicated
dedicated
dedicated
dedicated
15 + 15
30 + 30
40 + 40
15 + 15
5
10
15
5
8+8
8+8
8+8
8 + 15
15
15
15
15/686
553 + 553
553 + 553
528
48
49
50
46
68
69
70
66
590x800x300 1264x800x300 1264x800x300 590x800x300
64
99
102
58
2
2
2
3
3/8 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4

38GL3M30G
Rotary
shared
dedicated
15+30
5
8 + 15
15/553
50
70
803x800x300
75
3
3/8 - 1/4
1/2 - 1/4

38GL4M24G
Rotary
shared
shared
30 + 30
5
15 + 15
15/15
769
50
70
803x800x300
69
4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
30 + 30
230-1-50

38YY2M24G 38YY2M36G 38YY2M48G


Rotary
Rotary
Rotary
dedicated
dedicated
dedicated
dedicated
dedicated
dedicated
15 + 15
30 + 30
40 + 40
5
15
15
8+8
8+8
8+8
15/15
20/20
20/20
210
150
179
48
49
50
68
69
70
803x800x300 1264x800x300 1264x800x300
64
99
102
2
2
2
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
30 + 30
50 + 50
60 + 60
230-1-50
230-1-50
230-1-50

Sound pressure level in emispheric field at 4 m.


Performances evaluated with 5m interconnecting tubes.

DEDICATED COMPRESSORS

Ultra-reliable compressor. Ideal for both residential and small business applications.

38GL_M/YY_M - AIR-COOLED CONDENSING UNITS

CONTROLS

8 models cooling only from 2kW to 13kW and 5 models in heat pump from 5kW to 14kW

FEATURES
SHARED COMPRESSORS

38GL_M/YY_M FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M

38GL_M/YY_M Multi-split Condensing Unit


Outdoor unit (CO
Compressor Type
Compressor
Compressor
Maximum pipe length
Maximum height difference
Chargeless length
Additional charge
Air flow
Sound pressure level*
Sound power level
Dimensions (H x L x D)
Weight
Max. number of indoor units

Design and components optimised for operation with R410A refrigerant.


Rotary or scroll compressor, synonymous with high reliability and energy efficiency.

Modular control system

ACCESSORIES/OPTIONS
Wall bracket
Low ambient kit

Exceptionally low noise fan.


New generation coil for optimised heat transfer.

INDOOR UNITS

Reduced unit size and weight make this one of the most compact units in its
class on the market.
For power

For economy

To satisfy the needs of shops and offices, where maximium


power is required simultaneously in more than one space,
Carrier offers models with two dedicated compressors each
serving one indoor unit, so that the power of each compressor
is exploited to the full.

Ideal to air-condition spaces where maximum conditioning


power is not usually required simultaneously, such as the daytime and night-time areas of a house, Carrier has developed
the multisplit with split compressor.

Low-ambient device guarantees optimum and safe operation, even at extremely low outside temperatures (down to -15C for 38GLS/YLS).

42PHQ_S

42VMC

40KMC

40SMC
40DMC

48

49

38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS


FIXED SPEED SPLIT SYSTEM

Flare connections [A]

inch

38GL2M12G
Rotary
Shared

15
5
15
331
43
63
590x660x250
39
2
3/8 - 1/4
1/2 - 1/4

Flare connections [B]

inch

3/8 - 1/4

1/2 - 1/4

1/2 - 1/4

1/2 - 1/4

3/8 - 1/4

3/8 - 1/4

A
V-ph-Hz

30
230-1-50

30 + 30
230-1-50

30 + 30
230-1-50

50 + 50
230-1-50

60 + 60
230-1-50

30 + 30
230-1-50

30 + 50
230-1-50

38YY2M18G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15/15
167
45
65
590x800x300
55
2
3/8 - 1/4
3/8 - 1/4
25 + 25
230-1-50

38YY2M21G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15/15
210
48
68
803x800x300
61
2
1/2 - 1/4
1/2 - 1/4
25 + 30
230-1-50

Starting current
Power Supply

Outdoor unit (HP)


Compressor Type
Compressor [A]
Compressor [B]
Maximum pipe length
Maximum height difference
Chargeless length
Additional charge
Air flow
Sound pressure level*
Sound power level
Dimensions (H x L x D)
Weight
Max. number of indoor units
Flare connections [A]
Flare connections [B]
Starting current
Power Supply
*

[A]
[B]
m
m
m
g/m
l/s
dB(A)
dB(A)
mm
kg

m
m
m
g/m
l/s
dB(A)
dB(A)
mm
kg
inch
inch
A
V-ph-Hz

38GL2M18G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15
533
45
65
590x800x300
55
2
3/8 - 1/4

38GL2M24G 38GL2M36G 38GL2M48G 38GL3M21G


Rotary
Rotary
Rotary
Rotary
dedicated
dedicated
dedicated
shared
dedicated
dedicated
dedicated
dedicated
15 + 15
30 + 30
40 + 40
15 + 15
5
10
15
5
8+8
8+8
8+8
8 + 15
15
15
15
15/686
553 + 553
553 + 553
528
48
49
50
46
68
69
70
66
590x800x300 1264x800x300 1264x800x300 590x800x300
64
99
102
58
2
2
2
3
3/8 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4

38GL3M30G
Rotary
shared
dedicated
15+30
5
8 + 15
15/553
50
70
803x800x300
75
3
3/8 - 1/4
1/2 - 1/4

38GL4M24G
Rotary
shared
shared
30 + 30
5
15 + 15
15/15
769
50
70
803x800x300
69
4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
30 + 30
230-1-50

38YY2M24G 38YY2M36G 38YY2M48G


Rotary
Rotary
Rotary
dedicated
dedicated
dedicated
dedicated
dedicated
dedicated
15 + 15
30 + 30
40 + 40
5
15
15
8+8
8+8
8+8
15/15
20/20
20/20
210
150
179
48
49
50
68
69
70
803x800x300 1264x800x300 1264x800x300
64
99
102
2
2
2
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
30 + 30
50 + 50
60 + 60
230-1-50
230-1-50
230-1-50

Sound pressure level in emispheric field at 4 m.


Performances evaluated with 5m interconnecting tubes.

DEDICATED COMPRESSORS

Ultra-reliable compressor. Ideal for both residential and small business applications.

38GL_M/YY_M - AIR-COOLED CONDENSING UNITS

CONTROLS

8 models cooling only from 2kW to 13kW and 5 models in heat pump from 5kW to 14kW

FEATURES
SHARED COMPRESSORS

38GL_M/YY_M FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M

38GL_M/YY_M Multi-split Condensing Unit


Outdoor unit (CO
Compressor Type
Compressor
Compressor
Maximum pipe length
Maximum height difference
Chargeless length
Additional charge
Air flow
Sound pressure level*
Sound power level
Dimensions (H x L x D)
Weight
Max. number of indoor units

Design and components optimised for operation with R410A refrigerant.


Rotary or scroll compressor, synonymous with high reliability and energy efficiency.

Modular control system

ACCESSORIES/OPTIONS
Wall bracket
Low ambient kit

Exceptionally low noise fan.


New generation coil for optimised heat transfer.

INDOOR UNITS

Reduced unit size and weight make this one of the most compact units in its
class on the market.
For power

For economy

To satisfy the needs of shops and offices, where maximium


power is required simultaneously in more than one space,
Carrier offers models with two dedicated compressors each
serving one indoor unit, so that the power of each compressor
is exploited to the full.

Ideal to air-condition spaces where maximum conditioning


power is not usually required simultaneously, such as the daytime and night-time areas of a house, Carrier has developed
the multisplit with split compressor.

Low-ambient device guarantees optimum and safe operation, even at extremely low outside temperatures (down to -15C for 38GLS/YLS).

42PHQ_S

42VMC

40KMC

40SMC
40DMC

48

49

38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS


FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M

PERFORMANCES 38GL_M (DUAL SPLIT)

PERFORMANCES 38GL_M (TRI SPLIT)

Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption

38GL2M12G
09+09

38GL2M12G
09+012

38GL2M18G
09+09

38GL2M24G
12+12

38GL2M36G
18+18

38GL2M48G
24+24

kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh

42PHQ-S
3,80
1550
2,45
E
775
3,81
1570
2,43
E
785
5,31
2170
2,45
E
1085
7,02
2780
2,53
E
1390
10,46
4050
2,58
E
2025
12,60
5220
2,41
na
2610

42VMC-N
3,76
1550
2,43
E
775
3,78
1550
2,44
E
775
4,90
2080
2,36
F
1040
6,89
2730
2,52
E
1365
10,28
3970
2,59
E
1985
12,80
5320
2,41
na
2660

40KMC-N
7,17
2860
2,51
E
1430
10,74
3990
2,69
D
1995
13,20
5300
2,49
na
2650

40SMC-N
3,10
1720
1,80
G
860
3,91
1730
2,26
F
865
5,40
2730
1,98
G
1365
7,00
3040
2,30
F
1520
9,45
4160
2,27
F
2080
12,50
5410
2,31
na
2705

40DMC
10,02
3890
2,58
E
1945
13,00
5500
2,36
na
2750

38GL3M21G
09+09+09

38GL3M21G
09+09+12

38GL3M30G
09+09+18

38GL3M30G
09+12+18

INDOOR UNITS
Operations

38GL2M12G
38GL2M18G
38GL2M24G
38GL2M36G
38GL2M48G

Circuit
B
--------09
12
18
24

Total
3,14
3,25
3,80
3,81
5,31
7,02
10,46
12,60

Cooling Capacity (W)


Circuit A
3,14
3,25
1,90
1,90
1,88
1,93
2,66
3,51
5,23
6,30

Circuit B
--------2,66
3,51
5,23
6,30

kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh

42PHQ-S
5,86
2360
2,48
E
1180
5,97
2380
2,51
E
1190
8,49
3670
2,31
F
1835
8,55
3690
2,32
F
1845

42VMC-N
5,82
2360
2,47
E
1180
5,86
2380
2,46
E
1190
8,73
3720
2,35
F
1860
8,79
3740
2,35
F
1870

40KMC-N
8,75
3710
2,36
F
1855
8,81
3730
2,36
F
1865

40SMC-N
5,92
2620
2,26
F
1310
5,96
2640
2,26
F
1320
8,40
3720
2,26
F
1860
8,46
3750
2,26
F
1875

40DMC
-

38GL3M30G

09
09
12
09+09
12+09
09+09
09+09+09
09+12+09
09
12
18
09+09
09+18
12+18
09+09+18
09+12+18

Circuit
A
09
--12
09
12
09+09
09+09
09+12
09
12
--09+09
09
12
09+09
09+12

Circuit
B
--09
--09
09
--09
09
----18
--18
18
18
18

Total
2,89
2,32
2,97
5,17
5,25
3,58
5,86
5,90
2,89
2,97
5,47
3,72
7,88
7,96
8,49
8,55

Cooling Capacity (W
Circuit A
2,89
--2,97
2,87
2,95
1,79+1,79
1,78+1,78
1,78+1,82
2,89
2,97
--1,86
1,86
2,87
2,95
1,74
1,74
1,74
1,80

Circuit B
--2,32
--2,30
2,30
--2,30
2,30
----5,47
--5,01
5,01
5,01
5,01

FIXED SPEED SPLIT SYSTEM

INDOOR UNITS COMBINATION


Circuit
A
09
012
09+09
09+012
09
12
18
24

kW
W
W/W

INDOOR UNITS COMBINATION

38GL3M21G

INDOOR UNITS
Operations
09
12
09+09
09+12
09+09
12+12
18+18
24+24

Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption

Data referred to combination with 42PHQ_P

DUAL SPLIT (Cooling)

38GL2M12G

50

38GL2M18G
38GL2M24G

TRI SPLIT

38GL2M36G
38GL2M48G

38GL3M21G

38GL3M30G

51

38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS


FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M

PERFORMANCES 38GL_M (DUAL SPLIT)

PERFORMANCES 38GL_M (TRI SPLIT)

Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption

38GL2M12G
09+09

38GL2M12G
09+012

38GL2M18G
09+09

38GL2M24G
12+12

38GL2M36G
18+18

38GL2M48G
24+24

kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh

42PHQ-S
3,80
1550
2,45
E
775
3,81
1570
2,43
E
785
5,31
2170
2,45
E
1085
7,02
2780
2,53
E
1390
10,46
4050
2,58
E
2025
12,60
5220
2,41
na
2610

42VMC-N
3,76
1550
2,43
E
775
3,78
1550
2,44
E
775
4,90
2080
2,36
F
1040
6,89
2730
2,52
E
1365
10,28
3970
2,59
E
1985
12,80
5320
2,41
na
2660

40KMC-N
7,17
2860
2,51
E
1430
10,74
3990
2,69
D
1995
13,20
5300
2,49
na
2650

40SMC-N
3,10
1720
1,80
G
860
3,91
1730
2,26
F
865
5,40
2730
1,98
G
1365
7,00
3040
2,30
F
1520
9,45
4160
2,27
F
2080
12,50
5410
2,31
na
2705

40DMC
10,02
3890
2,58
E
1945
13,00
5500
2,36
na
2750

38GL3M21G
09+09+09

38GL3M21G
09+09+12

38GL3M30G
09+09+18

38GL3M30G
09+12+18

INDOOR UNITS
Operations

38GL2M12G
38GL2M18G
38GL2M24G
38GL2M36G
38GL2M48G

Circuit
B
--------09
12
18
24

Total
3,14
3,25
3,80
3,81
5,31
7,02
10,46
12,60

Cooling Capacity (W)


Circuit A
3,14
3,25
1,90
1,90
1,88
1,93
2,66
3,51
5,23
6,30

Circuit B
--------2,66
3,51
5,23
6,30

kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh

42PHQ-S
5,86
2360
2,48
E
1180
5,97
2380
2,51
E
1190
8,49
3670
2,31
F
1835
8,55
3690
2,32
F
1845

42VMC-N
5,82
2360
2,47
E
1180
5,86
2380
2,46
E
1190
8,73
3720
2,35
F
1860
8,79
3740
2,35
F
1870

40KMC-N
8,75
3710
2,36
F
1855
8,81
3730
2,36
F
1865

40SMC-N
5,92
2620
2,26
F
1310
5,96
2640
2,26
F
1320
8,40
3720
2,26
F
1860
8,46
3750
2,26
F
1875

40DMC
-

38GL3M30G

09
09
12
09+09
12+09
09+09
09+09+09
09+12+09
09
12
18
09+09
09+18
12+18
09+09+18
09+12+18

Circuit
A
09
--12
09
12
09+09
09+09
09+12
09
12
--09+09
09
12
09+09
09+12

Circuit
B
--09
--09
09
--09
09
----18
--18
18
18
18

Total
2,89
2,32
2,97
5,17
5,25
3,58
5,86
5,90
2,89
2,97
5,47
3,72
7,88
7,96
8,49
8,55

Cooling Capacity (W
Circuit A
2,89
--2,97
2,87
2,95
1,79+1,79
1,78+1,78
1,78+1,82
2,89
2,97
--1,86
1,86
2,87
2,95
1,74
1,74
1,74
1,80

Circuit B
--2,32
--2,30
2,30
--2,30
2,30
----5,47
--5,01
5,01
5,01
5,01

FIXED SPEED SPLIT SYSTEM

INDOOR UNITS COMBINATION


Circuit
A
09
012
09+09
09+012
09
12
18
24

kW
W
W/W

INDOOR UNITS COMBINATION

38GL3M21G

INDOOR UNITS
Operations
09
12
09+09
09+12
09+09
12+12
18+18
24+24

Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption

Data referred to combination with 42PHQ_P

DUAL SPLIT (Cooling)

38GL2M12G

50

38GL2M18G
38GL2M24G

TRI SPLIT

38GL2M36G
38GL2M48G

38GL3M21G

38GL3M30G

51

38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS


FIXED SPEED SPLIT SYSTEM

38GL4M24G
'09+09+09+09

38GL4M24G
09+09+09+12

38GL4M24G
09+12+09+12

Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption

PERFORMANCES 38YY_M (DUAL SPLIT HEATING)

kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh

42PHQ_S
6,96
2760
2,52
E
1380
7,00
2790
2,51
E
1395
7,04
2840
2,48
E
1420

42VMC-N
7,02
2750
2,55
E
1375
7,05
2780
2,54
E
1390
7,10
2810
2,53
E
1405

40KMC-N
6,98
2740
2,55
E
1370
7,02
2810
2,50
E
1405

40SMC-N
7,13
3070
2,32
F
1535
7,17
3100
2,31
F
1550
7,21
3150
2,29
F
1575

40DMC
-

38GL4M24G

09
12
09+09
09+09
09+12
09+12
12+12
09+09+09
09+09+12
09+09+12
09+12+12
09+09+09+09
09+09+09+12
09+12+09+12

38YY2M21G
09+12

38YY2M24G
12+12

INDOOR UNITS COMBINATION


INDOOR UNITS
Operations

38YY2M18G
09+09

Circuit
A
09
12
09+09
09
09+012
09
12
09+09
09+12
09+09
09+12
09+09
09+09
09+12

Circuit
B
------09
--12
12
09
09
12
12
09+09
09+12
09+12

Total
2,83
2,87
3,60
5,42
3,64
5,47
5,50
6,22
6,26
6,26
6,30
6,96
7,00
7,04

1,80
1,80

1,74
1,74
1,74
1,74
1,74
1,74
1,74

Cooling Capacity (W
Circuit A
2,83
2,87
1,80
2,71
1,84
2,71
2,75
1,74
1,78
1,74
1,78
1,74
1,74
1,78

Circuit B
------2,71
--2,76
2,75
2,74
2,74
2,78
2,78
1,74
1,74
1,74

38YY2M36G
38YYS2M36G
18+18

1,74
1,78
1,78

38YY2M48G
38YYS2M48G
24+24

Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)

QUADRI SPLIT

38GL4M24G

52

kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W

42PHQ_S
5,55
2080
2,67
D
1040
5,83
1860
3,13
D
6,45
2310
2,79
D
1155
6,95
2300
3,02
D
6,80
2660
2,56
E
1330
7,05
2460
2,87
D
9,87
3770
2,62
D
1885
10,60
3490
3,04
D
12,10
4900
2,47
na
2450
14,20
5220
2,72
na

42VMC-N
5,29
1930
2,74
D
965
5,58
1970
2,83
D
6,16
2180
2,83
C
1090
6,67
2420
2,76
E
6,50
2510
2,59
E
1255
6,80
2550
2,67
E
10,00
3890
2,57
E
1945
10,90
3650
2,99
D
13,00
5080
2,56
na
2540
13,80
5360
2,57
na

40KMC-N
6,62
2640
2,51
E
1320
6,96
2490
2,80
E
9,78
3850
2,54
E
1925
11,5
3650
3,15
D
12,7
4980
2,55
na
2490
13,6
5400
2,52
na

40SMC-N
5,05
2140
2,36
F
1070
5,48
2080
2,63
E
5,84
2440
2,39
F
1220
6,47
2540
2,55
F
6,12
2860
2,14
G
1430
6,50
2660
2,44
F
9,23
3960
2,33
F
1980
10,40
3930
2,65
E
12,08
4560
2,65
na
2280
14,20
5000
2,84
na

40DMC
9,95
3750
2,65
D
1875
10,80
3350
3,22
C
13,20
4920
2,68
na
2460
14,20
4800
2,96
na

38GL_M/YY_M FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M

PERFORMANCES 38GL_M (QUADRI SPLIT)

DUAL SPLIT

38YY2M18G

38YY2M21G
38YY2M24G

38YY2M36G
38YY2M48G

53

38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS


FIXED SPEED SPLIT SYSTEM

38GL4M24G
'09+09+09+09

38GL4M24G
09+09+09+12

38GL4M24G
09+12+09+12

Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption

PERFORMANCES 38YY_M (DUAL SPLIT HEATING)

kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh

42PHQ_S
6,96
2760
2,52
E
1380
7,00
2790
2,51
E
1395
7,04
2840
2,48
E
1420

42VMC-N
7,02
2750
2,55
E
1375
7,05
2780
2,54
E
1390
7,10
2810
2,53
E
1405

40KMC-N
6,98
2740
2,55
E
1370
7,02
2810
2,50
E
1405

40SMC-N
7,13
3070
2,32
F
1535
7,17
3100
2,31
F
1550
7,21
3150
2,29
F
1575

40DMC
-

38GL4M24G

09
12
09+09
09+09
09+12
09+12
12+12
09+09+09
09+09+12
09+09+12
09+12+12
09+09+09+09
09+09+09+12
09+12+09+12

38YY2M21G
09+12

38YY2M24G
12+12

INDOOR UNITS COMBINATION


INDOOR UNITS
Operations

38YY2M18G
09+09

Circuit
A
09
12
09+09
09
09+012
09
12
09+09
09+12
09+09
09+12
09+09
09+09
09+12

Circuit
B
------09
--12
12
09
09
12
12
09+09
09+12
09+12

Total
2,83
2,87
3,60
5,42
3,64
5,47
5,50
6,22
6,26
6,26
6,30
6,96
7,00
7,04

1,80
1,80

1,74
1,74
1,74
1,74
1,74
1,74
1,74

Cooling Capacity (W
Circuit A
2,83
2,87
1,80
2,71
1,84
2,71
2,75
1,74
1,78
1,74
1,78
1,74
1,74
1,78

Circuit B
------2,71
--2,76
2,75
2,74
2,74
2,78
2,78
1,74
1,74
1,74

38YY2M36G
38YYS2M36G
18+18

1,74
1,78
1,78

38YY2M48G
38YYS2M48G
24+24

Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)

QUADRI SPLIT

38GL4M24G

52

kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W

42PHQ_S
5,55
2080
2,67
D
1040
5,83
1860
3,13
D
6,45
2310
2,79
D
1155
6,95
2300
3,02
D
6,80
2660
2,56
E
1330
7,05
2460
2,87
D
9,87
3770
2,62
D
1885
10,60
3490
3,04
D
12,10
4900
2,47
na
2450
14,20
5220
2,72
na

42VMC-N
5,29
1930
2,74
D
965
5,58
1970
2,83
D
6,16
2180
2,83
C
1090
6,67
2420
2,76
E
6,50
2510
2,59
E
1255
6,80
2550
2,67
E
10,00
3890
2,57
E
1945
10,90
3650
2,99
D
13,00
5080
2,56
na
2540
13,80
5360
2,57
na

40KMC-N
6,62
2640
2,51
E
1320
6,96
2490
2,80
E
9,78
3850
2,54
E
1925
11,5
3650
3,15
D
12,7
4980
2,55
na
2490
13,6
5400
2,52
na

40SMC-N
5,05
2140
2,36
F
1070
5,48
2080
2,63
E
5,84
2440
2,39
F
1220
6,47
2540
2,55
F
6,12
2860
2,14
G
1430
6,50
2660
2,44
F
9,23
3960
2,33
F
1980
10,40
3930
2,65
E
12,08
4560
2,65
na
2280
14,20
5000
2,84
na

40DMC
9,95
3750
2,65
D
1875
10,80
3350
3,22
C
13,20
4920
2,68
na
2460
14,20
4800
2,96
na

38GL_M/YY_M FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M

PERFORMANCES 38GL_M (QUADRI SPLIT)

DUAL SPLIT

38YY2M18G

38YY2M21G
38YY2M24G

38YY2M36G
38YY2M48G

53

CONTROLS RANGE

KIT FOR SATELLITE UNITS

LOCAL WIRED CONTROL

BUILDING MANAGEMENT

ROOM CONTROLLER 33MC-RC

ZONE MANAGER 33MC-ZM

Wall receiver for ducted satellite units Fixed speed


and XPower inverter.

MAIN FUNCTIONS:

1 x

WIRED CONTROL FOR SINGLE APPLICATIONS:

8 x

This small and elegant wall mounted control serves up to 6 unitswith


the same operating setting.

32

SYSTEMS MONITORING:
This building supervisor can control and set schedules up to 32 different indoors units in 8 indipendent zones.

CONTROLS RANGE DIRECT EXPANSION SPLIT SYSTEMS

DIRECT EXPANSION SPLIT SYSTEMS CONTROLS RANGE

DIRECT EXPANSION SPLIT SYSTEMS

ALUMINIUM COLOR

The basic and most used buttons are ergonomically placed for intuitive
and user friendly operations.

MY COMFORT:
Allows selection and memorization of the favourite end-user setting via
the remote control.

LIQUID CRYSTAL DISPLAY:

WEEKLY PROGRAMMING

All settings and operation paremeters clearly displayed.

User can select four individual start/stop ranges per day of the week
for each zone.

EASY MODE AND FAN SELECTION BUTTON:

ZONE SETTINGS AND LOCAL OPERATION:

Quick choice between cooling, heating, dehumidification, fan only or


auto.

Any individual unit within each zone can be operated by the end-user
according to his desires by overiding zone setting.

GROUPING FUNCTIONALITY:

AUTONOMOUS OPERATION:

This control is suitable to operate up to 6 units located in the same


zone. ( 1 accessoty usable for up to 5 slave units is required for proper
installation of 33MC9002).

If power failure occurs, clock operations are maintained for up to 20


hours, while programmed parameters are kept in the memory.

EXTRA POWER:
With this setting the fan will run at maximum speed and the setpoint
will be reached quickly.

IONIZER:
The ionizer can be operated separately, to deliver millions of negative
ions in the ambient and give an immediate sensation of well-being.

Available for XPower sensation (42PQV_S) in style


with the unit design.

ECONOMY:
The unit will work at low speed for maximum energy saving and silent
operation.

LOUVRE CONTROL:

HiWall
Fixed speed
Inverter

54

42PQV (LC)

Air flow direction can be remotely adjusted to optimized the air flow
distribution and suit individual preferences.

Console

Cassette

Satellite

42VMC

40KMC

40SMC
40DMC

PROGRAMMING FUNCTIONS:

42VQV

40KQV

40SQV
40DQV

Clock and 24 hours timer, sleep mode or continous programming settings are easily available.

Function may vary depending on the unit

55

CONTROLS RANGE

KIT FOR SATELLITE UNITS

LOCAL WIRED CONTROL

BUILDING MANAGEMENT

ROOM CONTROLLER 33MC-RC

ZONE MANAGER 33MC-ZM

Wall receiver for ducted satellite units Fixed speed


and XPower inverter.

MAIN FUNCTIONS:

1 x

WIRED CONTROL FOR SINGLE APPLICATIONS:

8 x

This small and elegant wall mounted control serves up to 6 unitswith


the same operating setting.

32

SYSTEMS MONITORING:
This building supervisor can control and set schedules up to 32 different indoors units in 8 indipendent zones.

CONTROLS RANGE DIRECT EXPANSION SPLIT SYSTEMS

DIRECT EXPANSION SPLIT SYSTEMS CONTROLS RANGE

DIRECT EXPANSION SPLIT SYSTEMS

ALUMINIUM COLOR

The basic and most used buttons are ergonomically placed for intuitive
and user friendly operations.

MY COMFORT:
Allows selection and memorization of the favourite end-user setting via
the remote control.

LIQUID CRYSTAL DISPLAY:

WEEKLY PROGRAMMING

All settings and operation paremeters clearly displayed.

User can select four individual start/stop ranges per day of the week
for each zone.

EASY MODE AND FAN SELECTION BUTTON:

ZONE SETTINGS AND LOCAL OPERATION:

Quick choice between cooling, heating, dehumidification, fan only or


auto.

Any individual unit within each zone can be operated by the end-user
according to his desires by overiding zone setting.

GROUPING FUNCTIONALITY:

AUTONOMOUS OPERATION:

This control is suitable to operate up to 6 units located in the same


zone. ( 1 accessoty usable for up to 5 slave units is required for proper
installation of 33MC9002).

If power failure occurs, clock operations are maintained for up to 20


hours, while programmed parameters are kept in the memory.

EXTRA POWER:
With this setting the fan will run at maximum speed and the setpoint
will be reached quickly.

IONIZER:
The ionizer can be operated separately, to deliver millions of negative
ions in the ambient and give an immediate sensation of well-being.

Available for XPower sensation (42PQV_S) in style


with the unit design.

ECONOMY:
The unit will work at low speed for maximum energy saving and silent
operation.

LOUVRE CONTROL:

HiWall
Fixed speed
Inverter

54

42PQV (LC)

Air flow direction can be remotely adjusted to optimized the air flow
distribution and suit individual preferences.

Console

Cassette

Satellite

42VMC

40KMC

40SMC
40DMC

PROGRAMMING FUNCTIONS:

42VQV

40KQV

40SQV
40DQV

Clock and 24 hours timer, sleep mode or continous programming settings are easily available.

Function may vary depending on the unit

55

42HQE_G - HIGH-WALL UNITS


FIXED SPEED SPLIT SYSTEM
42HQE_G
42HQE009G
38YE009G

42HQE012G
38YE012G

Cooling capacity (CO)

kW

2,5

3,5

Power Input (CO)

889

1245

W/W

2,81

2,81

E.E.R.
Energy efficiency class (CO)

445

623

Annual Energy Consumption

kWh

Heating Capacity

kW

2,9

4,0

Power Input (HP)

903

1246

W/W

3,21

3,21

009

012

C.O.P.
Energy Efficiency Class (HP)
Indoor unit
Dehumidification

l/h

1,0

1,2

Nominal air flow (l/m/h)

l/s

97/110/125

105/130/178

Sound pressure (l/m/h)

dB(A)*

33/36/39

32/35/42

Sound power (l/m/h)

dB(A)

47/49/52

45/48/55

Dimensions (HxLxD)

mm

250x750x188

280x815x195

Weight
Power Supply

kg

8,5

10,5

V-ph-Hz

230-1-50

230-1-50

Outdoor unit (HP)

009

012

Compressor Type

Rotary

Rotary

Maximum pipe length

10

10

Maximum height difference

Chargeless

dB(A)**

40

41

Sound pressure
Sound power

dB(A)

60

61

Dimensions (HxLxD)

mm

535x700x235

540x780x250

Weight

kg

Flare Connections
Power Supply
*
**

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4 m.
Performances evaluated with 5m interconnecting tubes and according to EN14511.

V-ph-Hz

28

35

1/4" - 3/8"

1/4" - 1/2"

230-1-50

230-1-50

IN

Four products in one: dehumidifier, heater, air


conditioner and fan. A product to use in every
season.

42HQE_G FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 42HQE_G

Indoor unit
Outdoor unit (HP)

42HQE_G - HIGH-WALL UNITS


Allegro Plus is the friendly air-conditioner that refreshes in summer and
provides warm in winter. The ideal companion throughout the years.

CONTROLS

2 sizes heat pump from: 2,5 kW to 3,5 kW in cooling; 2,9 kW to 4,0 kW in heating.

FEATURES
Modern and trendy design thanks to its simple lines.
Allegro Plus uses R410A, the no ozone depleting refrigerant for better performances.

Programmable timer

Easy to use remote control for a quick programming of well-being. The wide
display gives a clear and precise view of the active setting.
The active carbon filter eliminates bacteria and bad odours.
Customised air flow thanks to the adjustable louvers.

OUTDOOR UNITS

The outdoor unit coils fins have been treated with blue-fin anti-corrosion coating.
Outdoor unit the connections are protected by a protective shield; a feature not
common in similar products..
VDE safety mark, worldwide recognised for reliability.
All data are Eurovent certified.
38YE_G

56

57

42HQE_G - HIGH-WALL UNITS


FIXED SPEED SPLIT SYSTEM
42HQE_G
42HQE009G
38YE009G

42HQE012G
38YE012G

Cooling capacity (CO)

kW

2,5

3,5

Power Input (CO)

889

1245

W/W

2,81

2,81

E.E.R.
Energy efficiency class (CO)

445

623

Annual Energy Consumption

kWh

Heating Capacity

kW

2,9

4,0

Power Input (HP)

903

1246

W/W

3,21

3,21

009

012

C.O.P.
Energy Efficiency Class (HP)
Indoor unit
Dehumidification

l/h

1,0

1,2

Nominal air flow (l/m/h)

l/s

97/110/125

105/130/178

Sound pressure (l/m/h)

dB(A)*

33/36/39

32/35/42

Sound power (l/m/h)

dB(A)

47/49/52

45/48/55

Dimensions (HxLxD)

mm

250x750x188

280x815x195

Weight
Power Supply

kg

8,5

10,5

V-ph-Hz

230-1-50

230-1-50

Outdoor unit (HP)

009

012

Compressor Type

Rotary

Rotary

Maximum pipe length

10

10

Maximum height difference

Chargeless

dB(A)**

40

41

Sound pressure
Sound power

dB(A)

60

61

Dimensions (HxLxD)

mm

535x700x235

540x780x250

Weight

kg

Flare Connections
Power Supply
*
**

Sound pressure level in a free field according to JIS9612 Standard.


Sound pressure level in emispheric field at 4 m.
Performances evaluated with 5m interconnecting tubes and according to EN14511.

V-ph-Hz

28

35

1/4" - 3/8"

1/4" - 1/2"

230-1-50

230-1-50

IN

Four products in one: dehumidifier, heater, air


conditioner and fan. A product to use in every
season.

42HQE_G FIXED SPEED SPLIT SYSTEM

FIXED SPEED SPLIT SYSTEM 42HQE_G

Indoor unit
Outdoor unit (HP)

42HQE_G - HIGH-WALL UNITS


Allegro Plus is the friendly air-conditioner that refreshes in summer and
provides warm in winter. The ideal companion throughout the years.

CONTROLS

2 sizes heat pump from: 2,5 kW to 3,5 kW in cooling; 2,9 kW to 4,0 kW in heating.

FEATURES
Modern and trendy design thanks to its simple lines.
Allegro Plus uses R410A, the no ozone depleting refrigerant for better performances.

Programmable timer

Easy to use remote control for a quick programming of well-being. The wide
display gives a clear and precise view of the active setting.
The active carbon filter eliminates bacteria and bad odours.
Customised air flow thanks to the adjustable louvers.

OUTDOOR UNITS

The outdoor unit coils fins have been treated with blue-fin anti-corrosion coating.
Outdoor unit the connections are protected by a protective shield; a feature not
common in similar products..
VDE safety mark, worldwide recognised for reliability.
All data are Eurovent certified.
38YE_G

56

57

73FC/XC/YC - WINDOW UNIT


ROOM AIR CONDITIONERS
73Series
XCY127DR

XCP187DR

kW

2,6

3,5

5,2

6,7

Power Input

945

1200

2110

2720

W/W

2,75

2,92

2,46

2,46

473

600

1055

1360

ROOM AIR CONDITIONERS 73FC/XC/YC

EER
Energy efficiency class
Annual energy consumption
Dehumidification

l/h

0,7

1,6

2,4

3,3

Air flow*

l/s

103

188

217

283

Dimensions (H x L x D)

mm

330x600x470

425x640x610

425x640x610

445x712x600

Weight
Power Supply
*

kWh

YCN247DR

kg

28

52

55

72

V-ph-Hz

220-1-50

220-1-50

220-1-50

220-1-50

SILENTIA

High speed.

Extremely quiet and very energy-efficient.

73FC/XC/YC ROOM AIR CONDITIONERS

FCC097RB

Cooling Capacity

Model

73FC/XC/YC - WINDOW UNIT


The new Carrier range features up-to-date design and superior energysaving performance.

CONTROLS

FEATURES
Powerful, compact unit - 30% smaller than other comparable units.
Uniform air distribution pattern and quiet operation make these units an obvious
choice for optimum comfort day after day.
Superior efficiency for ultimate comfort.
Just four models covering most requirements up to 7 kW.
All units are equipped with infrared remote control.

COMPACT

Powerful, compact unit.


30% smaller than other comparable units.

73FC

58

73XC/YC

59

73FC/XC/YC - WINDOW UNIT


ROOM AIR CONDITIONERS
73Series
XCY127DR

XCP187DR

kW

2,6

3,5

5,2

6,7

Power Input

945

1200

2110

2720

W/W

2,75

2,92

2,46

2,46

473

600

1055

1360

ROOM AIR CONDITIONERS 73FC/XC/YC

EER
Energy efficiency class
Annual energy consumption
Dehumidification

l/h

0,7

1,6

2,4

3,3

Air flow*

l/s

103

188

217

283

Dimensions (H x L x D)

mm

330x600x470

425x640x610

425x640x610

445x712x600

Weight
Power Supply
*

kWh

YCN247DR

kg

28

52

55

72

V-ph-Hz

220-1-50

220-1-50

220-1-50

220-1-50

SILENTIA

High speed.

Extremely quiet and very energy-efficient.

73FC/XC/YC ROOM AIR CONDITIONERS

FCC097RB

Cooling Capacity

Model

73FC/XC/YC - WINDOW UNIT


The new Carrier range features up-to-date design and superior energysaving performance.

CONTROLS

FEATURES
Powerful, compact unit - 30% smaller than other comparable units.
Uniform air distribution pattern and quiet operation make these units an obvious
choice for optimum comfort day after day.
Superior efficiency for ultimate comfort.
Just four models covering most requirements up to 7 kW.
All units are equipped with infrared remote control.

COMPACT

Powerful, compact unit.


30% smaller than other comparable units.

73FC

58

73XC/YC

59

51AKE / AKB / AKC - PORTABLES


51AKE / AKB / AKC
51AKE 065

51AKB 065

51AKB 085

51AKB 010

Cooling Capacity

kW

1,71

1,71

2,1

2,6

3,35

Power Input

630

630

820

850

1190

W/W

2,71

2,71

2,56

3,06

2,82

315

315

410

425

595

Indoor unit

EER
Energy class
Annual energy consumption
Dehumidification

l/h

0,75

0,75

1,1

1,4

1,9

Air flow (l/h)

l/s

75/90

75/90

75/90

133/104

133/104

Sound pressure level IU (l/h)

dB(A)

46/48

46/48

46/48

46/43

46/43

Sound pressure level OU

dB(A)

50

50

Dimensions IU (H x L x D)

mm

850x440x350

850x440x350

850x440x350

850x440x350

850x440x350

Weight IU

kg

28

28

28,5

30

35

Dimensions OU (H x L x D)

mm

430x413x230

430x413x230

Weight OU

kg

11,5

11,5

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

Air discharge tube, max. length

mm

1100

1100

1100

Interconnecting Pipe Length

mm

1800

3600*

3,2

3,2

4,4

4,4

5,8

Power Supply

Electric heater current


*

kWh

51AKC 013

IN

Three products in one: air conditioner, dehumidifier with easy-to-empty water tank and fan. A
product for all seasons.

with quick couplings.


Performance data according to EN14511.

51AKE / AKB / AKC ROOM AIR CONDITIONERS

ROOM AIR CONDITIONERS 51AKE / AKB / AKC

ROOM AIR CONDITIONERS

51AKE / AKB / AKC - PORTABLES


The portable Holiday units offer exceptional versatility combined with style
to ensure optimum individual comfort in both residential rooms and single
offices up to 40m.

CONTROLS

51AKE

FEATURES
Practical and intuitive - the mechanical interface is easy to use.
Small but powerful - small and light in weight, but very efficient at the same
time.
Up to 1.6 l/h dehumidification capacity. Condensate collected in an easy-toempty tank.

51AKB
51AKB/C

ACCESSORIES
Set of three porthole covers
IAQ (indoor air quality) filter kit

The energy consumption is much lower than that of a microwave oven or iron.
Removing the condensate is no problem thanks to the removable tank; no
pipes or sinks required.
Split units are available with quick couplings for installation flexibility.
Fully ecological - units use R-407C or R-410A refrigerant and have 100% recyclable packaging.

CASTORS INCLUDED

Monobloc and split versions - one of the smallest and lightest portable air conditioners on the market.

51 AKE 065

60

51AKB 065
51AKB 085

52AKB 010
53AKB 013

Easily movable from room to room with minimum effort.

61

51AKE / AKB / AKC - PORTABLES


51AKE / AKB / AKC
51AKE 065

51AKB 065

51AKB 085

51AKB 010

Cooling Capacity

kW

1,71

1,71

2,1

2,6

3,35

Power Input

630

630

820

850

1190

W/W

2,71

2,71

2,56

3,06

2,82

315

315

410

425

595

Indoor unit

EER
Energy class
Annual energy consumption
Dehumidification

l/h

0,75

0,75

1,1

1,4

1,9

Air flow (l/h)

l/s

75/90

75/90

75/90

133/104

133/104

Sound pressure level IU (l/h)

dB(A)

46/48

46/48

46/48

46/43

46/43

Sound pressure level OU

dB(A)

50

50

Dimensions IU (H x L x D)

mm

850x440x350

850x440x350

850x440x350

850x440x350

850x440x350

Weight IU

kg

28

28

28,5

30

35

Dimensions OU (H x L x D)

mm

430x413x230

430x413x230

Weight OU

kg

11,5

11,5

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

Air discharge tube, max. length

mm

1100

1100

1100

Interconnecting Pipe Length

mm

1800

3600*

3,2

3,2

4,4

4,4

5,8

Power Supply

Electric heater current


*

kWh

51AKC 013

IN

Three products in one: air conditioner, dehumidifier with easy-to-empty water tank and fan. A
product for all seasons.

with quick couplings.


Performance data according to EN14511.

51AKE / AKB / AKC ROOM AIR CONDITIONERS

ROOM AIR CONDITIONERS 51AKE / AKB / AKC

ROOM AIR CONDITIONERS

51AKE / AKB / AKC - PORTABLES


The portable Holiday units offer exceptional versatility combined with style
to ensure optimum individual comfort in both residential rooms and single
offices up to 40m.

CONTROLS

51AKE

FEATURES
Practical and intuitive - the mechanical interface is easy to use.
Small but powerful - small and light in weight, but very efficient at the same
time.
Up to 1.6 l/h dehumidification capacity. Condensate collected in an easy-toempty tank.

51AKB
51AKB/C

ACCESSORIES
Set of three porthole covers
IAQ (indoor air quality) filter kit

The energy consumption is much lower than that of a microwave oven or iron.
Removing the condensate is no problem thanks to the removable tank; no
pipes or sinks required.
Split units are available with quick couplings for installation flexibility.
Fully ecological - units use R-407C or R-410A refrigerant and have 100% recyclable packaging.

CASTORS INCLUDED

Monobloc and split versions - one of the smallest and lightest portable air conditioners on the market.

51 AKE 065

60

51AKB 065
51AKB 085

52AKB 010
53AKB 013

Easily movable from room to room with minimum effort.

61

51AKS - PORTABLES
ROOM AIR CONDITIONERS
51AKS Portables
51AKS185

kW

2,1

2,1

2,6

2,6

3,35

3,35

3,35

3,77

Power Input

820

820

850

850

1190

1190

1190

1500

W/W

2,56

2,56

3,06

3,06

2,82

2,82

2,82

2,51

410

410

425

425

595

595

595

750

EER

ROOM AIR CONDITIONERS 51AKS

Energy class
Annual energy consumption

51AKS113

51AKS015C-P

Dehumidification

l/h

1,1

1,1

1,4

1,4

1,9

1,9

1,9

2,7

Air flow (l/h)

l/s

75/90

75/90

133/104

133/104

133/104

133/104

133/104

133/104

Sound pressure level IU (l/h)

dB(A)

46/48

46/48

46/43

46/43

46/43

46/43

46/43

46/44

Sound pressure level OU

dB(A)

50

50

50

50

50

50

Dimensions IU (H x L x D)

mm

850x440x390 850x440x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390

Weight IU

kg

28,5

28,5

Dimensions OU (H x L x D)

mm

Weight OU

30,0

30,0

36

36

36

36

430x413x230 430x413x230 430x413x230 430x413x230 430x413x230 430x413x230

kg

11,5

11,5

11,5

11,5

11,5

11,5

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

Air discharge tube, max. length

mm

1100

1100

Interconnecting Pipe Length

mm

1800

3600*

1800

3600*

1800

3600*

Electric heater capacity

Power Supply

kWh

51AKS010-P 51AKS010C-P 51AKS013-P 51AKS013C-P

kW

1,6

1,6

Current drawn (cooling mode)

4,4

4,4

4,4

4,4

5,8

5,8

5,8

6,8

Current drawn (heating mode)

7,0

7,0

Up to four products in one: air conditioner,


dehumidifier with removable water tank, fan
and heater (see detail). A product for all four
seasons.

with quick couplings.


Performance data according to EN14511.

51AKS ROOM AIR CONDITIONERS

51AKS085

Cooling Capacity

Indoor unit

51AKS - PORTABLES
The 51AKS is the elegant ready-to-use solution for use in different rooms
at home or in the office.

CONTROLS

FEATURES
51AKS

Electronic interface - advanced, immediate and intuitive technology allows easy


and precise programming of personal comfort conditions.
Choice of various capacity and colour combinations to suit all user requirements.
Minimal noise levels for ultra-quiet operation, essential for total relaxation.

ACCESSORIES
Set of three porthole covers
IAQ (indoor air quality) filter kit

Sleep function - the lights are dimmed, fresh air is supplied at a soft whisper:
ideal conditions for relaxed sleep and sweet dreams.
Precise and powerful humidity control - with eight dehumidification levels and a
removable tank, the split version removes up to 65 litres of water per day from
the air.
Extra compact and light - easy-to-move and not intrusive, blends in with any
room surroundings.

BENCHMARK

Removing the condensate is no problem thanks to the removable tank; no


pipes or sinks required.

51AKS 085
51AKS 185

62

51AKS 085-P

51AKS 085 AL

51AKS 010 P
51AKS 010 C-P
51AKS 013 P
51AKS 013 C-P
51AKS 015 C-P

51AKS 113

The smallest outdoor unit on the market

63

51AKS - PORTABLES
ROOM AIR CONDITIONERS
51AKS Portables
51AKS185

kW

2,1

2,1

2,6

2,6

3,35

3,35

3,35

3,77

Power Input

820

820

850

850

1190

1190

1190

1500

W/W

2,56

2,56

3,06

3,06

2,82

2,82

2,82

2,51

410

410

425

425

595

595

595

750

EER

ROOM AIR CONDITIONERS 51AKS

Energy class
Annual energy consumption

51AKS113

51AKS015C-P

Dehumidification

l/h

1,1

1,1

1,4

1,4

1,9

1,9

1,9

2,7

Air flow (l/h)

l/s

75/90

75/90

133/104

133/104

133/104

133/104

133/104

133/104

Sound pressure level IU (l/h)

dB(A)

46/48

46/48

46/43

46/43

46/43

46/43

46/43

46/44

Sound pressure level OU

dB(A)

50

50

50

50

50

50

Dimensions IU (H x L x D)

mm

850x440x390 850x440x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390

Weight IU

kg

28,5

28,5

Dimensions OU (H x L x D)

mm

Weight OU

30,0

30,0

36

36

36

36

430x413x230 430x413x230 430x413x230 430x413x230 430x413x230 430x413x230

kg

11,5

11,5

11,5

11,5

11,5

11,5

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

Air discharge tube, max. length

mm

1100

1100

Interconnecting Pipe Length

mm

1800

3600*

1800

3600*

1800

3600*

Electric heater capacity

Power Supply

kWh

51AKS010-P 51AKS010C-P 51AKS013-P 51AKS013C-P

kW

1,6

1,6

Current drawn (cooling mode)

4,4

4,4

4,4

4,4

5,8

5,8

5,8

6,8

Current drawn (heating mode)

7,0

7,0

Up to four products in one: air conditioner,


dehumidifier with removable water tank, fan
and heater (see detail). A product for all four
seasons.

with quick couplings.


Performance data according to EN14511.

51AKS ROOM AIR CONDITIONERS

51AKS085

Cooling Capacity

Indoor unit

51AKS - PORTABLES
The 51AKS is the elegant ready-to-use solution for use in different rooms
at home or in the office.

CONTROLS

FEATURES
51AKS

Electronic interface - advanced, immediate and intuitive technology allows easy


and precise programming of personal comfort conditions.
Choice of various capacity and colour combinations to suit all user requirements.
Minimal noise levels for ultra-quiet operation, essential for total relaxation.

ACCESSORIES
Set of three porthole covers
IAQ (indoor air quality) filter kit

Sleep function - the lights are dimmed, fresh air is supplied at a soft whisper:
ideal conditions for relaxed sleep and sweet dreams.
Precise and powerful humidity control - with eight dehumidification levels and a
removable tank, the split version removes up to 65 litres of water per day from
the air.
Extra compact and light - easy-to-move and not intrusive, blends in with any
room surroundings.

BENCHMARK

Removing the condensate is no problem thanks to the removable tank; no


pipes or sinks required.

51AKS 085
51AKS 185

62

51AKS 085-P

51AKS 085 AL

51AKS 010 P
51AKS 010 C-P
51AKS 013 P
51AKS 013 C-P
51AKS 015 C-P

51AKS 113

The smallest outdoor unit on the market

63

54DHS - DEHUMIDIFIERS
ROOM AIR CONDITIONERS
54DHS Dehumidifiers
Carrier model n

54DHS014

54DHS018

54DHS018HE

lt

11

14

18

18

24

Power consumption a 27C, 60% RH

205

232

410

410

410

m3/h

100

110

160

160

180

lt

Fan speeds

ROOM AIR CONDITIONERS 54DHS

Air flow
Tank capacity

54DHS024

Deodorizing filters

Yes

Antibacterial filters

Yes

Yes

Yes

Electric heater

Yes

Continuos drain hose connection

Yes

Yes

Yes

Yes

Yes

Container full light and auto shut off

Yes

Yes

Yes

Yes

Yes

Defrost

Yes

Yes

Yes

Yes

Yes

Electronic humidistat

Yes

Yes

Yes

Yes

Yes

Digital control

Yes

Yes

Castors

Yes

Yes

Yes

Yes

Yes

Transporting handle

Yes

Yes

Yes

Yes

Yes

5-35

5-35

5-35

5-35

5-35

R134A

R134A

R134A

R134A

R134A

Size (W x H x D)

mm

325x540x355

325x540x355

345x722x352

345x722x352

345x722x352

Weight

kg

15

15,5

19,5

19,5

22

Working limits
Refrigerant

The new Comfort dehumidifyng function


selects automatically the right level of humidity in relative to temperature variations.
(Idealday 24)

54DHS ROOM AIR CONDITIONERS

54DHS011

Capacity

*tested by EU directive CEE 73/23/CE

54DHS - DEHUMIDIFIERS
Idealday is the name, as these units offer the ideal solution for excess
humidity removal from your environment, preserving walls, furniture and
your health.

FEATURES

WHY IS IT SO IMPORTANT TO CONTROL THE HUMIDITY LEVEL?


Too much humidity damages your health and the furniture in the house. It harms people,
aggravating conditions like asthma, arthritis and rheumatism. High humidity levels cause
mould on the walls and damps patches, and spool surfaces. Humidity should be controlled
all year long, especially in rainy autumns and in humid summers.

CONTROLS

54DHS11
54DHS14

Special antibacterial filter to prevent growth of bacteria and form of mould for
purer and healthier environments. (Idealday 24 and 18HE)
Electronic control with multifunctional liquid crystal display with clock and timer
function for a precise regulation of the humidity level. (Idealday 24 and 18HE)
2 in 1 air purifier and dehumidifier. The two functions can be used also indipendently. (Idealday 14)

54DHS18

Large-capacity tank positioned on the front of the product for easy removal.
The dehumidifier stops automatically when the tank is full.
Version available with heater (800W) to speed up humidity absorption, giving
you a pleasant sensation of warmth. (Idealday 18HE).

54DHS18HE
54DHS24

Silent and light with integrated wheels.


2 speed turbo ventilator to quickly activate the set value.

ACCESSORIES

Connect up to the continuous flow condensation waste pipe if required.


All models use refrigerant without CFC/H-CFC to avoid ozone depleting.

54DHS18

54DHS18HE
54DHS24
ZO

N E D EP

R RIE R

TIO N

R-134a
CA

64

LE

ZERO O

54DHS11
54DHS14

54DHS 9000: set of three replacement carbon


filters

65

54DHS - DEHUMIDIFIERS
ROOM AIR CONDITIONERS
54DHS Dehumidifiers
Carrier model n

54DHS014

54DHS018

54DHS018HE

lt

11

14

18

18

24

Power consumption a 27C, 60% RH

205

232

410

410

410

m3/h

100

110

160

160

180

lt

Fan speeds

ROOM AIR CONDITIONERS 54DHS

Air flow
Tank capacity

54DHS024

Deodorizing filters

Yes

Antibacterial filters

Yes

Yes

Yes

Electric heater

Yes

Continuos drain hose connection

Yes

Yes

Yes

Yes

Yes

Container full light and auto shut off

Yes

Yes

Yes

Yes

Yes

Defrost

Yes

Yes

Yes

Yes

Yes

Electronic humidistat

Yes

Yes

Yes

Yes

Yes

Digital control

Yes

Yes

Castors

Yes

Yes

Yes

Yes

Yes

Transporting handle

Yes

Yes

Yes

Yes

Yes

5-35

5-35

5-35

5-35

5-35

R134A

R134A

R134A

R134A

R134A

Size (W x H x D)

mm

325x540x355

325x540x355

345x722x352

345x722x352

345x722x352

Weight

kg

15

15,5

19,5

19,5

22

Working limits
Refrigerant

The new Comfort dehumidifyng function


selects automatically the right level of humidity in relative to temperature variations.
(Idealday 24)

54DHS ROOM AIR CONDITIONERS

54DHS011

Capacity

*tested by EU directive CEE 73/23/CE

54DHS - DEHUMIDIFIERS
Idealday is the name, as these units offer the ideal solution for excess
humidity removal from your environment, preserving walls, furniture and
your health.

FEATURES

WHY IS IT SO IMPORTANT TO CONTROL THE HUMIDITY LEVEL?


Too much humidity damages your health and the furniture in the house. It harms people,
aggravating conditions like asthma, arthritis and rheumatism. High humidity levels cause
mould on the walls and damps patches, and spool surfaces. Humidity should be controlled
all year long, especially in rainy autumns and in humid summers.

CONTROLS

54DHS11
54DHS14

Special antibacterial filter to prevent growth of bacteria and form of mould for
purer and healthier environments. (Idealday 24 and 18HE)
Electronic control with multifunctional liquid crystal display with clock and timer
function for a precise regulation of the humidity level. (Idealday 24 and 18HE)
2 in 1 air purifier and dehumidifier. The two functions can be used also indipendently. (Idealday 14)

54DHS18

Large-capacity tank positioned on the front of the product for easy removal.
The dehumidifier stops automatically when the tank is full.
Version available with heater (800W) to speed up humidity absorption, giving
you a pleasant sensation of warmth. (Idealday 18HE).

54DHS18HE
54DHS24

Silent and light with integrated wheels.


2 speed turbo ventilator to quickly activate the set value.

ACCESSORIES

Connect up to the continuous flow condensation waste pipe if required.


All models use refrigerant without CFC/H-CFC to avoid ozone depleting.

54DHS18

54DHS18HE
54DHS24
ZO

N E D EP

R RIE R

TIO N

R-134a
CA

64

LE

ZERO O

54DHS11
54DHS14

54DHS 9000: set of three replacement carbon


filters

65

Anda mungkin juga menyukai