Anda di halaman 1dari 4
VRNFS DATA SHEETS_Rev 01 Saudi Electricity Company CS tran SEC DISTRIBUTION MATERIALS SPECIFICATION __32-SDMS-01, Rev. 02 DATE: 31-10-20076 9.0 DATA SCHEDULE NON-EXTENCIBLE RING MAIN UNIT, SF6, 17.5 kV (VRN-FS) (Sheet ! of 3) SEC Inquiry No. tem No. REF. SEC. DESCRIPTION SEC VENDOR SPECIFIED PROPOSED VALUE VALUES DESIGN AND CONSTRUCTION REQUIREMENTS: GENERAL RMU Type - Indoor / Outdoor IndooriOutdoor RMU Configuration 3-Way /4-Way 3.Way 3. Tee-of Breaker Fuse-switch with shunt coil Not applicable 5. Term. fastener for Ring switch Mi6 Term. fastener for Tee-Of M12. GENERAL DK 1211 I. Service Voltage 2. Maximum Operating Voltage aR A75KV 3. Rated Frequency 60Hz 4, Rated Current of Load Break (As per clause 4.3) 400A(upto 630A) 5. Rated Current of Fuse ‘Switches (As per clause 4.3) Not applicable 6. Short circuit withstand current Ring switches (1 sec.) 21 kA, = 7. Rated Making Current of Ring switches (peak) S0kA BKM 8. Rated Making Current of Earthing Switches (peak) S0kA = 9. Rated Making Current of Fuse Switch (peak) Ach Not applicable 10. Impulse Withstand Voltage 95 kV 35KV_ II. Power Frequency Withstand Voltage (1 min.) "As given in (01-SDMS-01) a 12, Internal Are fault withstand for 1 second 20kA VRNFS DATA SHEETS _Rev 01 Saudi Electricity Company G oly gS Aya geal As tat 32-SDMS-1, Rev. 02 DATE: 31-10-2007G SEC DISTRIBUTION MATERIALS SPECIFICATION 9.0 DATA SCHEDULE NON-EXTENCIBLE RING MAIN UNIT, SF6, 17.5 kV (VRN- FS) (Sheet 2 of 3) ‘SEC Inquiry No. Item No. [453 [CIRCUIT T. Service Voltage 13.8KV 13.BKV 2. Maximum Operating Voliage 17.5 kV 17.5KV 3. Rated Frequency 60 Hz. eoHz 4. Rated Current of CB 200 A 250A 5, Rated Short circuit level (1 s) 21 kA 7 2ikA 6. Rated Making Current S50 kA 50kA 7. Re-striking Voltage Ratio 14 15 8. Duty Cycle 0-4-CO- CO [6-3min-CO-3min-CO ‘9, Making time aioe ‘Not applicable 10.Opening time ms ‘55ms 1. Are Duration ms ams 12. Total Breaking Time ms ‘e7ms 13. Operating Mechanism ‘Spring Charged | Spring Charged 452 | DIMENSIONS OF FUSE - 1. Overall Length of Fuse 442 mm Not applicable 2. Overall Diameter mm Not applicable 49 TERMINATION / CABLE BOX Cable box size - Rofer GA attached Vertical distance (bushing to | 750mm NCLOSURE FOR OUTDOOR UNITS 1. Overall Dimensions of ‘Width x Depths Height | Complied with SOMS Completely Assembled RMU (mx xm) Refer GA attached 2. Degree of Protection ‘AS per 01-SDMS-01 IP 54 3. Finish Method GAL Paint 4. Finish Color RAL 7033 RAL 7033 DK21 ~ © Page 18 of 25 VRNFS DATA SHEETS Rev 01 Company G ele gSl Aya geal AS pitt 32-SDMS-01, Rev. 02 DATE: 31-10-2007G SEC DISTRIBUTION MATERIALS SPECIFICATION 9.0 DATA SCHEDULE, NON-EXTENCIBLE RING MAIN UNIT, SF6, 17.5 kV (Sheet 3 of 3) SEC Inquiry No, tem No. ADDITIONAL TECHNICAL INFORMATION OR FEATURES SPECIFIED BY SEC: ADDITIONAL SUPPLEMENTARY DATA OR FEATURES PROPOSED BY BIDDER/VENDOR/SUPPLIER: OTHER PARTICULARS TO BE FILLED UP BY BIDDER/VENDORY SUPPLIER: LIST OF DEVIATIONS & CLAUSES TO WHICH EXCEPTIONS ARE TAKEN BY THE BIDDER/VENDOR/SUPPLIER: (USE SEPARATE SHEET IF NECESSARY) MANUFACTURER OF VENDOR / SUPPLIER MATERIALS/EQUIPMEN Name of Company Lucas seuihel ote Tocation and Office = Address fl-Kbober - 4 ‘Name and Signature of Authorize 1. Representative Official Seal / Stamp DK1211 \ “Page 19 of 25 DOOR FULLY OFEN Dera. A, ae i GA OF VRN FS FOR SEC APPROVAL | ==> EVEL ALM THMo026484 _|Iss, sivis Ivrea] “s51] PEpOzOONAT

Anda mungkin juga menyukai