Consolidate your auto switches.


Simplify your onsite inventory control.

Contents - Auto Switch Guide Section

Auto Switch Guide

C55
C76
C85
C95
CA2
CE1

Auto-Switch Guide

CG1
CG5..S
CJ2
CJP2
CJ5..S
CL1
CLG1
CLJ2
CLM2
CLQ
CLS

CM2
CNA
CNG
CNS
CP95
CQ2
CQM
CQS
CRA1

CRB1
CRB2
CRBU
CRJ
CRQ2
CS1
CU
CUJ
CXS
CXSJ
CXT
CXW
CY1F
CY1H/HT
CY1L
CY1S
CY3R

E-MY2
MB
MB1
MDHR2
MDHR3
MGC
MGF
MGG
MGJ
MGP
MGT
MGZ(R)

1210

20 to 63
32, 40
8 to 25
32 to 250
40 to 100
12 to 25
32 to 63
20 to 100
20 to 100
6, 10, 16
4, 6, 10, 16
10, 16
40 to 160
20 to 40
16
20 to 40
20 to 100
125 to 200
125 to 250
20 to 40
40 to 100
20 to 40
125, 140, 160
32 to 100
12 to 25
32 to 100
125 to 200
12 to 50
12 to 25
30
50 to 100
50 to 100
10 to 40
10 to 40
0.5, 1
10 to 40
125 to 200
6 to 32
6 to 10
6 to 32
6 to 32
12 to 40
10 to 32
10, 15, 25
10 to 32
6 to 40
6 to 40
6 to 20
25 to 63
16, 25
32 to 125
32 to 100
10 to 30
10, 15
20 to 50
40, 63, 100
20 to 100
6, 10
12 to 100
63, 80, 100
63, 80, 100
20, 25, 32
40 to 80

nd
Ba

ro
d

Size

Tie

Series

D
(R irec
ou t
nd
Gr
oo
Di
(R rec ve)
ec t
tan
gu
lar
Di
Gr
(fo rec
oo
r ro t
ve
)
tar
ya
ctu
Ra
ato
il
r s)

Select an auto switch model according with the series and mounting style.

Auto Switch Mounting Style


Notes
Direct (Round Groove)
Band
Band
Tie rod
Tie rod
Rail
Direct (Round Groove)
Band
Band (use D-G5BAL) Water resistant
Band
Direct (Round Groove)
Band (use D-H7BAL) Water resistant
Tie rod
Band
Band
Band
Direct (Round Groove)
Tie rod for cylinder unit
Direct (Round Groove) for lock unit
Band
Tie rod
Band
Tie rod
Direct (Rectangular Groove)
Rail
Direct (Round Groove)
Direct (Rectangular Groove)
Direct (Round Groove)
Direct (Round Groove)
Rail (for rotary actuators)
Direct (for rotary actuators)
Direct (for rotary actuators)
Direct (for rotary actuators)
Direct (for rotary actuators)
Direct (Round Groove)
Direct (Round Groove)
Tie rod
Direct (Round Groove)
Direct (Round Groove, use D-F8 tye)
Direct (Rectangular Groove)
Direct (Round Groove)
Direct (Round Groove)
Rail
Direct (Round Groove)
Direct (Rectangular Groove)
Rail
Rail
Direct (Round Groove)
Direct (Rectangular Groove)
Direct (Round Groove)
Tie rod
Direct (Rectangular Groove)
Direct (use solid state switch)
Direct (use solid state switch)
Band
Direct (Rectangular Groove)
Band
Direct (Round Groove, use D-F8 tye)
Direct (Rectangular Groove)
Cylinder unit: Direct (Rectangular Groove)
Table unit: Direct (Round Groove)
Direct (Round Groove)
Direct (Rectangular Groove)

Page
No.
9-4
9-8
9-8
9-7
9-7
9-6
9-4
9-8
9-8
9-8
9-4
9-8
9-7
9-8
9-8
9-8
9-4
9-7
9-4
9-8
9-7
9-8
9-7
9-5
9-6
9-4
9-5
9-4
9-4
9-10
9-10
9-10
9-10
9-10
9-4
9-4
9-7
9-4
9-4
9-5
9-4
9-4
9-6
9-4
9-5
9-6
9-6
9-4
9-5
9-4
9-7
9-5
9-4
9-4
9-8
9-5
9-8
9-4
9-5
9-5
9-4
9-4
9-5

MHF2
MHK2
MHL2
MHS

MHT2
MHW2
MHY2
MHZ2
MHZJ2
MHZL2
MIW/MIS
MK
MK2

MLGP
MLU
MNB
MRHQ

MRQ
MSQ
MSU
MSZ
MTS
MU
MXF
MXH
MXJ
MXP
MXQ
MXS
MXU
MXW
MXY
MY1

MY2
MY3A/3B/3M
REAH/HT
REAL
REAR

REAS
REBH/HT
REBR

REC
RHC
RLQ
RQ
RSA
RSG
RSH/RS1H
RSQ

RZQ
SGC

d
Ba
n

ro
d

10 to 25
6
8 to 20
12 to 25
10 to 40
16 to 25
32 to 125
32 to 63
20 to 50
10 to 25
10 to 40
6
6 to 25
16 to 25
10
8 to 32
12, 16, 32 to 63
20, 25
32 to 63
20, 25
20 to 100
25 to 50
32 to 100
10 to 25
10 to 25
32, 40
1 to
10 to 200
1 to 20
10 to 50
8 to 40
25 to 63
8 to 20
6 to 20
4.5, 6, 8
6 to 16
6 to 25
6 to 25
6 to 16
8 to 25
6 to 12
10, 16, 20
25 to 100
16, 25, 40
16 to 63
10 to 32
10 to 40
10, 15, 20
25, 32, 40
10 to 40
15, 25, 32
15
25, 32
20 to 40
20 to 100
32 to 63
20 to 100
50, 63, 80
40, 50
20 to 80
12, 32 to 50
16, 20
32 to 63

Auto Switch Mounting Style


Notes
Direct (use solid state switch)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (Round Groove)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (use solid state switch)
Direct (Round Groove)
Direct (Round Groove)
Rail
Direct (Round Groove)
Rail
Direct (Rectangular Groove)
Rail
Tie rod
Rotation unit: Direct (In-line type)
Gripper unit: Direct (Perpendicular type)
Rail
Direct (use solid state switch)
Direct (Round Groove)
Direct (for rotary actuators)
Direct (Round Groove)
Direct (Round Groove)
Rail
Direct (Round Groove)
Direct (Round Groove)
Direct (Round Groove)
Direct (Round Groove)
Direct (Round Groove)
Direct (Round Groove)
Direct (Round Groove)
Direct (Round Groove)
Direct (Round Groove)
Direct (Round Groove)
Direct (Rectangular Groove)
Direct (Round Groove)
Direct (Round Groove)
Direct (Rectangular Groove)
Rail
Direct (Round Groove)
Direct (Rectangular Groove)
Rail
Direct (Rectangular Groove)
Direct (Round Groove)
Direct (Rectangular Groove)
Band
Band
Direct (Round Groove)
Direct (Round Groove)
Direct (Rectangular Groove)
Band
Direct (use solid state switch)
Direct (Round Groove)
Rail
Direct (Round Groove)
Direct (use solid state switch)

Page
No.
-5
-4
-4
-4
-5
-4
-5
-4
-5
-4
-4
-5
-4
-4
-5
-4
-4
-6
-4
-6
-5
-6
-
-4
-4
-6
-4
-4
-10
-4
-4
-6
-4
-4
-4
-4
-4
-4
-4
-4
-4
-4
-5
-4
-4
-5
-6
-4
-5
-6
-5
-4
-5
-8
-8
-4
-4
-5
-8
-5
-4
-6
-4
-4

Auto-Switch Guide

MHC2

Size

Tie

Series

D
(R irec
ou t
nd
Gr
oo
Di
ve
(R rec
)
ec t
tan
gu
lar
D
Gr
(fo irec
oo
rr t
ve
ota
)
ry
ac
tua
Ra
tor
il
s)

Contents - Auto Switch Guide Section

The basic cylinder series is shown here. To use auto switches the magnetic version must be specified, unless a magnet for auto switches is standard.
Eg. for CQ2 cylinders CDQ2 must be specified. See individual catalogue sections for details.

FOR MORE DETAILS


SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION

1211

Contents - Auto Switch Guide Section

Direct mounting style


Round groove
Auto switch

D-M9

Auto-Switch Guide

Applicable Auto Switch/Direct mounting


Reed switch type
Applicable
Series
C55
CJP2
CE1 (32~63)
CLQ
CLS
CQ2 (32~100)
CQM
CQS
CRJ
CRQ2
CU
CXSJ
CXT
CY1F
CY3R (6~20)
E-MY2
MDHR2
MDHR3
MGT (60~100)
MGZ/R (20~32)
MHC2 (6)
MHF2
MHK2
MHS (10~25)
MHT2
MHY2
MHZ2

24 VDC
2-wire
MIW/MIS
MK (12, 16, 32~ 63)
MK2 (32~63)
MRHQ
MSQ (1~7)
MSQ (10~200)
MSZ
MTS
MXF
MXH
MXJ
MXP
MXQ
MXS
MXU
MXW
MXY
MY1 (10~20)
MY2
MY3
REAR (10~20)
REBR (15)
RLQ
RQ,
RSQ
RZQ
SGC

D-A93L

Solid state switch type


24 VDC
3-wire (PNP)

24 VDC
3-wire (NPN)

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)

D-M9PL

D-M9NL

D-M9PWL

Description

Lead wire length = 3 m,


consult SMC for other length.

Auto switch with pre-wired


connector (M8-3pin).

D-M9PSAPC

D-M9NSAPC

D-M9PWSAPC

Lead wire length = 0.5 m,


consult SMC for other length.

Since there are other applicable auto switches than listed, refer to Best Pneumatics catalogue for details.
() Only solid state switches can be used.
() Bracket BMY3-016 is also required.

D-F8
Short body type

Applicable Auto Switch/Short Body Type/Direct mounting


Solid state switch type
Applicable
Series
CUJ
MGJ
CRJ
MSQ (1~7)

24 VDC
2-wire

24 VDC
3-wire (PNP)

24 VDC
3-wire (NPN)

D-F8BL

D-F8PL

D-F8NL

() Also applicable to these models for short strokes.

1212

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)

Description

Lead wire length = 3 m,


consult SMC for other length.

Contents - Auto Switch Guide Section

Direct mounting style


Rectangular groove

Mounting
bracket
BMG2-012

Auto switch

D-M9

Applicable Auto Switch + Mounting Bracket (BMG2-012)


Reed switch type

CP95
MB1
CQ2 (125~200)
CY3R (25~63)
MGF
MGP
MGT
MGZ/R (40~80)
MHC2 (10~25)
MHL2
MHS (32~125)

MHW2
MLGP
MHZ2 (10)
MHZL2 (10)
MLGP
MY1 (25~100)
REAR (25~40)
REBR (25, 32)
RSA
RSQ (12, 32~63)
RSH/RS1H

Solid state switch type

24 VDC
2-wire

24 VDC
3-wire (PNP)

24 VDC
3-wire (NPN)

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)

D-A93L
+
BMG2-012

D-M9PL
+
BMG2-012

D-M9NL
+
BMG2-012

D-M9PWL
+
BMG2-012

Description

Lead wire length = 3 m,


consult SMC for other length.

Auto switch with pre-wired


connector (M8-3pin).

D-M9PSAPC
+
BMG2-012

D-M9NSAPC
+
BMG2-012

D-M9PWSAPC
+
BMG2-012

Lead wire length = 0.5 m,


consult SMC for other length.

Since there are other applicable auto switches than listed, refer to Best Pneumatics catalogue for details.
() Only solid state switches can be used.
() Bracket BMP1-032 is also required.
() Solid state switches must be used for all MY1 types and bore sizes. MY1B (40), MY1M (25, 40), MY1C (40) and MY1HT (50, 63) use different switches,
see separate table below.

Auto switch mounting screw


M2.5 x 4 l

Auto switch mounting screw


(M3 x 0.5 x 8 l)

Auto switch
D-Z73
D-Y7P
D-Y59

Auto switch
D-A73
D-F7P
D-F79

Auto switch mounting nut


(Hexagon nut)

Applicable Auto Switch (MY1B, bore sizes 25 to 100 and MY1HT bore sizes 50, 63)
(CXS bore sizes 6 to 32 and CXSW bore sizes 6 to 32)
Reed switch type
Applicable
Series
MY1B (40)
CXS
MY1M (25, 40) CXSW
MY1C (40)
MY1HT

CXW

Solid state switch type

24 VDC
2-wire

24 VDC
3-wire (PNP)

24 VDC
3-wire (NPN)

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)

D-Z73L

D-Y7PL

D-Y59AL

D-Y7PWL

With lead wire length = 3 m


Consult SMC for other length.

D-Y7PSAPC

D-Y59ASAPC

D-Y7PWSAPC

With pre-wired connector (M83pin). Lead wire length = 0.5m


Consult SMC for other length.

D-A73HL

D-F7PL

D-F79L

D-F7PWL

With lead wire length = 3 m


Consult SMC for other length.

D-F7PSAPC

D-F79SAPC

D-F7PWSAPC

With pre-wired connector (M83pin). Lead wire length = 0.5m


Consult SMC for other length.

FOR MORE DETAILS


SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION

Description

1213

Auto-Switch Guide

Applicable
Series

Contents - Auto Switch Guide Section

Mounting
bracket
BQ2-012

Rail mounting style

Auto switch

D-M9

Applicable Auto Switch + Mounting Bracket (BQ2-012)

Auto-Switch Guide

Reed switch type


Applicable
Series

CE1 (12 to 25)


CJ2 (10, 16)
CQ2 (12 to 25)
MK (20, 25)
MK2 (20, 25)
MU
MLU
MRQ
RSQ (16, 20)

Solid state switch type

24 VDC
2-wire

24 VDC
3-wire (PNP)

24 VDC
3-wire (NPN)

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)

D-A93L
+
BQ2-012

D-M9PL
+
BQ2-012

D-M9NL
+
BQ2-012

D-M9PWL
+
BQ2-012

Description

Lead wire length = 3 m,


consult SMC for other length.

Auto switch with pre-wired


connector (M8-3pin).
D-M9NSAPC
+
BQ2-012

D-M9PSAPC
+
BQ2-012

D-M9PWSAPC
+
BQ2-012

Lead wire length = 0.5 m,


consult SMC for other length.

Since there are other applicable auto switches than those listed, refer to SMC's Best Pneumatics catalogue for details.
() Only solid state switches can be used.
() 12 - Only solid state switches can be used.
() CE1, CQ2, MK, MK2, RSQ use BQ-1 and BQ2-012 as a set.
MU, MLU use BMU2-025 and BQ2-012 as a set.
MRQ use BQ-2 and BQ2-012 as a set.

Auto switch
D-A73
D-F7P
D-F79
Auto switch mounting screw
M2.5 x 4 l
Auto switch
D-Z73
D-Y7P
D-Y59

Auto switch mounting nut


(Square nut M3)
Auto switch mounting screw
(M3 x 0.5 x 8 l)

Applicable Auto Switch (CY1, REA, bore size 6 to 100)


Reed switch type
24 VDC
2-wire

24 VDC
3-wire (PNP)

24 VDC
3-wire (NPN)

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)

CY1H
CY1HT
REAH
REAHT

D-Z73L

D-Y7PL

D-Y59AL

D-Y7PWL

With lead wire length = 3 m


Consult SMC for other length.

D-Y7PSAPC

D-Y59ASAPC

D-Y7PWSAPC

With pre-wired connector (M83pin). Lead wire length = 0.5m


Consult SMC for other length.

CY1S
CY1L
REAL
REAS

D-A73HL

D-F7PL

D-F79L

D-F7PWL

With lead wire length = 3 m


Consult SMC for other length.

D-F7PSAPC

D-F79SAPC

D-F7PWSAPC

With pre-wired connector (M83pin). Lead wire length = 0.5m


Consult SMC for other length.

Applicable
Series

1214

Solid state switch type


Description

Contents - Auto Switch Guide Section

Tie-rod mounting style


Auto switch
+
Mounting bracket

Auto-Switch Guide

D-M9

Applicable Auto Switch + Mounting bracket


Reed switch type

24 VDC
3-wire (NPN)

D-A93L
+
BMB5-032
D-A93L
+
BA7-040

D-M9PL
+
BMB5-032
D-M9PL
+
BA7-040

D-M9NL
+
BMB5-032
D-M9NL
+
BA7-040

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)
D-M9PWL
+
BMB5-032
D-M9PWL
+
BA7-040

80, 100

D-A93L
+
BA7-063

D-M9PL
+
BA7-063

D-M9NL
+
BA7-063

D-M9PWL
+
BA7-063

125

D-A93L
+
BA7-080

D-M9PL
+
BA7-080

D-M9NL
+
BA7-080

D-M9PWL
+
BA7-080

160, 200

D-A93L
+
BS5-160

D-M9PL
+
BS5-160

D-M9NL
+
BS5-160

D-M9PWL
+
BS5-160

40, 50

D-A93L
+
BA7-040

D-M9PL
+
BA7-040

D-M9NL
+
BA7-040

D-M9PWL
+
BA7-040

63

D-A93L
+
BA7-063

D-M9PL
+
BA7-063

D-M9NL
+
BA7-063

D-M9PWL
+
BA7-063

D-A93L
+
BA7-080
D-A93L
+
BS5-125
D-A93L
+
BS5-160

D-M9PL
+
BA7-080
D-M9PL
+
BS5-125
D-M9PL
+
BS5-160

D-M9NL
+
BA7-080
D-M9NL
+
BS5-125
D-M9NL
+
BS5-160

D-M9PWL
+
BA7-080
D-M9PWL
+
BS5-125
D-M9PWL
+
BS5-160

D-A93L
+
BS5-180

D-M9PL
+
BS5-180

D-M9NL
+
BS5-180

D-M9PWL
+
BS5-180

32, 40
50, 63

C95
MB (32 to 125)
MNB (32 to 100)

CA2
CNA
CL1

80, 100
125, 140

CS1
CLS
CNS (125 to 160)
CL1 (125 to 160)

Solid state switch type


24 VDC
3-wire (PNP)

Bore
size
(mm)

Applicable
Series

160
180

24 VDC
2-wire

D-A93L
D-M9NL
D-M9PL
+
+
+
BS5-200
BS5-200
BS5-200
Lead wire length = 3 m, consult SMC for other length.
Since there are other applicable auto switches than listed, refer to Best Pneumatics catalogue for details.
() Only solid state switches can be used on 50 cylinders.
() See separate table for C95 with 250mm bore size.
() Autoswitches cannot be fitted to CLS 250 cylinder part.
200

D-M9PWL
+
BS5-200

Auto switch
with pre-wired
connector

24 VDC
3-wire (PNP):
D-M9PSAPC
24 VDC
3-wire (NPN):
D-M9NSAPC

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP):
D-M9PWSAPC
1

M83 pin

Lead wire length = 0.5 m,


consult SMC for other length.

Applicable Auto Switch + Mounting bracket (C95, bore size 250mm)


Reed switch type
Applicable
Series

C95

Bore
size
(mm)

250

Solid state switch type

24 VDC
2-wire

24 VDC
3-wire (PNP)

24 VDC
3-wire (NPN)

D-A54L
+
BT-20

D-F5PL
+
BT-20
D-F5PSAPC
+
BT-20

D-F59L
+
BT-20
D-F59SAPC
+
BT-20

FOR MORE DETAILS


SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)
D-F5PWL
+
BT-20
D-F5PWSAPC
+
BT-20

Description
With lead wire length = 3 m
Consult SMC for other length.
With pre-wired connector (M83pin). Lead wire length = 0.5m
Consult SMC for other length.

1215

Contents - Auto Switch Guide Section

Band mounting style


Auto switch
Mounting
bracket
BJ3-1

Mounting
band
D-M9

Auto-Switch Guide

Applicable Auto Switch + Mounting Bracket (BJ3-1) + Mounting band


Reed switch type
Applicable
Series

C85 (8 to 16)
CJ2 (6, 10, 16)
CLJ2 (16)

C85 (20, 25)


C76 (32, 40)
CM2
CLM2

24 VDC
3-wire (PNP)

24 VDC
3-wire (NPN)

D-A93L
+
BJ3-1 + BJ2-006

D-M9PL
+
BJ3-1 + BJ2-006
D-M9PL
+
BJ3-1 + BJ2-008

D-M9NL
+
BJ3-1 + BJ2-006
D-M9NL
+
BJ3-1 + BJ2-008

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)
D-M9PWL
+
BJ3-1 + BJ2-006
D-M9PWL
+
BJ3-1 + BJ2-008

10

D-A93L
+
BJ3-1 + BJ2-010

D-M9PL
+
BJ3-1 + BJ2-010

D-M9NL
+
BJ3-1 + BJ2-010

D-M9PWL
+
BJ3-1 + BJ2-010

12

D-M9PL
+
BJ3-1 + BJ2-012

D-M9NL
+
BJ3-1 + BJ2-012

D-M9PWL
+
BJ3-1 + BJ2-012

16

D-A93L
+
BJ3-1 + BJ2-016

D-M9PL
+
BJ3-1 + BJ2-016

D-M9NL
+
BJ3-1 + BJ2-016

D-M9PWL
+
BJ3-1 + BJ2-016

20

D-A93L
+
BJ3-1 + BM2-020

D-M9PL
+
BJ3-1 + BM2-020

D-M9NL
+
BJ3-1 + BM2-020

D-M9PWL
+
BJ3-1 + BM2-020

25

D-A93L
+
BJ3-1 + BM2-025

D-M9PL
+
BJ3-1 + BM2-025

D-M9NL
+
BJ3-1 + BM2-025

D-M9PWL
+
BJ3-1 + BM2-025

D-A93L
+
BJ3-1 + BM2-032
D-A93L
+
BJ3-1 + BM2-040
D-A93L
+
BJ3-1 + BMA2-020

D-M9PL
+
BJ3-1 + BM2-032
D-M9PL
+
BJ3-1 + BM2-040
D-M9PL
+
BJ3-1 + BMA2-020

D-M9NL
+
BJ3-1 + BM2-032
D-M9NL
+
BJ3-1 + BM2-040
D-M9NL
+
BJ3-1 + BMA2-020

D-M9PWL
+
BJ3-1 + BM2-032
D-M9PWL
+
BJ3-1 + BM2-040
D-M9PWL
+
BJ3-1 + BMA2-020

D-A93L
+
BJ3-1 + BMA2-025

D-M9PL
+
BJ3-1 + BMA2-025

D-M9NL
+
BJ3-1 + BMA2-025

D-M9PWL
+
BJ3-1 + BMA2-025

D-A93L
+
BJ3-1 + BMA2-032
D-A93L
+
BJ3-1 + BMA2-040

D-M9PL
+
BJ3-1 + BMA2-032
D-M9PL
+
BJ3-1 + BMA2-040

D-M9NL
+
BJ3-1 + BMA2-032
D-M9NL
+
BJ3-1 + BMA2-040

D-M9PWL
+
BJ3-1 + BMA2-032
D-M9PWL
+
BJ3-1 + BMA2-040

50

D-A93L
+
BJ3-1 + BMA2-050

D-M9PL
+
BJ3-1 + BMA2-050

D-M9NL
+
BJ3-1 + BMA2-050

D-M9PWL
+
BJ3-1 + BMA2-050

63

D-A93L
+
BJ3-1 + BMA2-063

D-M9PL
+
BJ3-1 + BMA2-063

D-M9NL
+
BJ3-1 + BMA2-063

D-M9PWL
+
BJ3-1 + BMA2-063

32
40
20

CG1
CLG1 (20 to 40)
CNG (20 to 40)
MGC (20 to 50)
MGG
REC (20 to 40)
RHC
RSG (40, 50)

Solid state switch type

24 VDC
2-wire

Bore
size
(mm)

25
32

40

Auto switch
with pre-wired
connector

24 VDC
3-wire (PNP):
D-M9PSAPC
24 VDC
3-wire (NPN):
D-M9NSAPC

24 VDC
Diagnostic indication
(2-color indication)
3-wire (PNP):
D-M9PWSAPC
1

M83 pin

Lead wire length = 0.5 m,


consult SMC for other length.

Lead wire length = 3 m, consult SMC for other length.


Since there are other applicable auto switches than listed, refer to Best Pneumatics catalogue for details.
() 8 to 12, solid state switches only can be used.
() See separate table for CG1 and RHC with 80 and 100mm bore size.

Stainless Steel Cylinder:


Water resistant 2-colour indication
type. Solid state switch, 2-wire,
24VDC

1216

Series CG5-S

Series CJ5-S
Auto switch
model

D-H7BAL

Mounting bracket no.

Mounting bracket no.

10

16

Auto switch
model

20

25

32

40

50

63

80

100

BJ2010S

BJ2016S

D-G5BAL NBA088S

NBA106S

BGS1
-032S

BAF
-04S

BAF
-05S

BAF
-06S

BAF
-08S

BAF
-10S

Contents - Auto Switch Guide Section

Auto switch

Auto switch mounting


screw
M4 x 0.7 x 22 l

Applicable Auto Switch + Mounting Bracket (CG1, RHC, bore size 80, 100)
Reed switch type
Applicable
Series

Solid state switch type

Bore
size
(mm)

24 VDC
2-wire

24 VDC
3-wire (PNP)

24 VDC
3-wire (NPN)

80

D-B54L
+
BA-08

D-G5PL
+
BA-08
D-G5PSAPC
+
BA-08

D-G59L
+
BA-08
D-G59SAPC
+
BA-08

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)
D-G5PWL
+
BA-08
D-G5PWSAPC
+
BA-08

D-B54L
+
BA-10

D-G5PL
+
BA-10

D-G59L
+
BA-10

D-G5PWL
+
BA-10

D-G5PSAPC
+
BA-10

D-G59SAPC
+
BA-10

D-G5PWSAPC
+
BA-10

CG1
RHC
100

FOR MORE DETAILS


SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION

Description
With lead wire length = 3 m
Consult SMC for other length.
With pre-wired connector (M83pin). Lead wire length = 0.5m
Consult SMC for other length.
With lead wire length = 3 m
Consult SMC for other length.
With pre-wired connector (M83pin). Lead wire length = 0.5m
Consult SMC for other length.

1217

Auto-Switch Guide

Mounting bracket
BA-08, BA-10

Contents - Auto Switch Guide Section

Direct mounting style


For rotary actuators
(CRB2, CRBU2, CRB1, MSU)

D-93AL
Size (1, 3, 10, 15)

Auto-Switch Guide

D-S99/D-S9P
(size 1, 3, 10, 15)

D-R73/D-S79/D-S7P
(Size 7, 20, 30, 40, 50, 63, 80, 100)

Applicable Auto Switch/ Rotary actuators (CRB2, CRBU2, CRB1, MSU)


Applicable
Series

Size

1
3
10
15

CRB2
CRBU2
CRB1
MSU

7
20
30
40
50
63
80
100

Reed switch type


24 VDC
2-wire

Solid state switch type


24 VDC
3-wire (NPN)

D-93AL

D-S9P1L
+
D-S9P2L

D-S9P1SAPC
+
D-S9P2SAPC

D-R731L
+
D-R732L

Description

24 VDC
3-wire (PNP)

D-S7P1L
+
D-S7P2L

Lead wire length = 3 m, consult SMC for other


length.

D-S991SAPC
+
D-S992SAPC

D-S7P1SAPC
+
D-S7P2SAPC

D-S991L
+
D-S992L

D-S791L
+
D-S792L

Auto switch with pre-wired


connector (M8-3pin).
Lead wire length = 0.5 m,
consult SMC for other length.

D-S791SAPC
+
D-S792SAPC

Lead wire length = 3 m, consult SMC for other


length.
Auto switch with pre-wired
connector (M8-3pin).
Lead wire length = 0.5 m,
consult SMC for other length.

Note, left handed and right handed switches are needed so order one off each part number.
Since there are other applicable auto switches than listed, refer to Best Pneumatics catalogue for details.

Applicable Auto Switch/ Rotary actuators (CRA1)


Solid state switch type

Reed switch type


Applicable
Series

Size

24 VDC
Diagnostic indication
(2-colour indication)
3-wire (PNP)

24 VDC
2-wire

24 VDC
3-wire
(PNP)

24 VDC
3-wire
(NPN)

D-A73L

D-F7PL

D-F79L

D-F7PWL

D-F7PSAPC

D-F79SAPC

D-F7PWSAPC

D-A53L

D-F5PL

D-F59L

D-F5PWL

30

CRA1
50
63
80
100

D-F5PSAPC

D-F59SAPC

D-F5PWSAPC

Description

Lead wire length = 3 m, consult SMC for other


length.
Auto switch with pre-wired
connector (M8-3pin).
Lead wire length = 0.5 m,
consult SMC for other length.

Lead wire length = 3 m, consult SMC for other


length.
Auto switch with pre-wired
connector (M8-3pin).
Lead wire length = 0.5 m,
consult SMC for other length.

Since there are other applicable auto switches than listed, refer to Best Pneumatics catalogue for details.

1218

Contents - Auto Switch Guide Section

Auto Switch Specifications


Auto Switch Common Specifications
Type
Leakage current

Reed switch

Operating time

1.2 ms

1 ms or less

300 m/s2

1000 m/s2

Solid state switch

None

Impact resistance
Insulation resistance

50 M or more at 500 Mega VDC (between lead wire and case)


1000 VAC for 1 minute (between lead wire and case)

Ambient temperature

1000 VAC for 1 minute (between lead wire and case)

10 to 60C

Enclosure

IEC529 standard IP67, JIS C 0920 waterproof construction

Standard

Conforming to CE Standards

Contact Protection Boxes: CD-P11, CD-P12

How to Order

<Applicable switch model>

D- M9 P W V L
Lead wire length
Wiring and output

M
L
Z

3 wire, NPN
3 wire, PNP
2 wire

P
B

Colour indication
-

Standard (1-colour)

2-wire: 0.8 mA or less

0.5 m
1m
3m
5m

D-A9/A9V
The auto switches above do not have a built-in contact protection circuit.
Therefore, please use a contact protection box with the switch for any of
the following cases:
Where the operation load is an inductive load.
Where the wiring length to load is greater than 5 m.
Where the load voltage is 100 VAC.
The contact life may be shortened. (Due to permanent energising conditions.)

Specifications
Wiring entry

W 2-colour

In-line
Perpendicular

CD-P11
100 VAC
200 VAC

Part no.
Load voltage
Maximum load current
Lead wire length

25 mA

Switch connection side


Load connection side

12.5 mA

CD-P12
24 VDC
50 mA

0.5 m
0.5 m

Note 1) Applicable auto switch with 5 m lead wire Z


Solid state switch: Manufactured upon receipt of order as standard.
Note 2) For 1 m(M), available with D-M9W(V) only.

Internal Circuit
CD-P11
Surge absorber

Choke
coil

OUT Brown

OUT Blue

Choke coil

CD-P12
Zener diode

Applicable Wire Stripper

OUT ()
Blue

When the cable sheath is stripped, confirm the stripping


direction. The insulator may be split or damaged
depending on the direction. (D-M9(V) only)

Dimensions

Connection

Recommended Tool
Model name
Wire stripper

OUT (+)
Brown

Model no.
D-M9N-SWY

Stripper for a round cable (2.0) can be used for a 2-wire type cable.

FOR MORE DETAILS


SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION

To connect a switch unit to a contact protection box, connect the lead wire
from the side of the contact protection box marked SWITCH to the lead
wire coming out of the switch unit. Keep the switch as close as possible to
the contact protection box, with a lead wire length of no more than 1 metre.

1219

Auto-Switch Guide

Withstand voltage

3-wire: 100 A or less

Contents - Auto Switch Guide Section

Solid State Switch: Direct Mounting Style

D-M9N(V)/D-M9P(V)/D-M9B(V)
Auto Switch Specifications
Grommet

PLC: Programmable Logic Controller


Auto switch part no.

D-M9N

D-M9NV

D-M9P

D-M9PV

D-M9B

D-M9BV

Electrical entry direction

In-line

Perpendicular

In-line

Perpendicular

In-line

Perpendicular

3-wire

Wiring type

2-wire

NPN

Output type

PNP

IC circuit, Relay, PLC

24 VDC relay, PLC

Power supply voltage

5, 12, 24 VDC (4.5 to 28 V)

Current consumption

10 mA or less

Applicable load

Load voltage

28 VDC or less
40 mA or less

Load current

24 VDC (10 to 28 VDC)


2.5 to 40 mA

0.8 V or less

4 V or less

100 A or less at 24 VDC

0.8 mA or less

Internal voltage drop


Leakage current
Indicator light

Red LED illuminates when ON.

Standard

Conforming to CE Standards

Lead wires
Oilproof heavy-duty vinyl cable: 2.7 x 3.2 ellipse
D-M9B(V)
0.15 mm2 x 2 cores
D-M9N(V), D-M9P(V)
0.15 mm2 x 3 cores
Note 1) Refer to catalogue for details of solid state switch with pre-wired connector.
Note 2) Refer to catalogue for solid state switch common specifications and for lead wire lengths.

Weight

Unit: g

D-M9N(V)

Auto switch part no.

Operating Precautions

Fix the switch with the existing screw


installed on the switch body. The switch
may be damaged if a screw other than the
one supplied, is used.

Auto Switch Internal Circuit


D-M9N(V)

0.5

Lead wire length


(m)

41

41

38

68

68

63

Unit: mm

D-M9

6 Most sensitive position


22

Mounting screw M2.5 x 4 l


Slotted set screw
Indicator light

2.8

DC ()
Blue

2.6

2.7

OUT
Black

22

D-M9P(V)
Switch
main circuit

DC (+)
Brown

D-M9V
OUT
Black

2.7

9.5

D-M9B(V)

1220

4.6

Indicator light
8
3.2

Mounting screw M2.5 x 4 l


Slotted set screw
2

2.8

OUT ()
Blue

2.6

DC ()
Blue

OUT (+)
Brown

D-M9B(V)

Dimensions

DC (+)
Brown

Switch
main circuit

D-M9P(V)

3.2

Caution

Switch
main circuit

Auto-Switch Guide

2-wire load current is reduced


(2.5 to 40 mA).
Lead free
UL certified (style 2844) lead
cable is used.
Flexibility is 1.5 times greater than
the conventional model (SMC
comparison).
Using flexible cable as standard
spec.

D-M9/D-M9V (With indicator light)

6 Most sensitive position


20

Contents - Auto Switch Guide Section

2-Colour Indication Solid State Switch:


Direct Mounting Style

D-M9NW(V)/D-M9PW(V)/D-M9BW(V)
Auto Switch Specifications
Grommet

PLC: Programmable Logic Controller


Auto switch part no. D-M9NW D-M9NWV D-M9PW D-M9PWV D-M9BW D-M9BWV
In-line
Perpendicular
In-line
Perpendicular
In-line
Perpendicular
Electrical entry direction
2-wire

3-wire

Wiring type
NPN

Output type

PNP

IC circuit, Relay IC, PLC

24 VDC relay, PLC

Power supply voltage

5, 12, 24 VDC (4.5 to 28 VDC)

Current consumption

10 mA or less

Applicable load

Load voltage

28 VDC or less
40 mA or less

Load current

24 VDC (10 to 28 VDC)

2.5 to 40 mA

0.8 V or less at 10 mA (2 V or less at 40 mA)

Internal voltage drop

4 V or less

0.8 mA or less
100 A or less at 24 VDC
Operating position .......... Red LED illuminates.
Optimum operating position .......... Green LED illuminates.

Leakage current
Internal voltage
drop

Conforming to CE Standards

Standard

Lead wires
Oilproof heavy-duty vinyl cable: 2.7 x 3.2 ellipse
D-M9BW(V)
0.15 mm2 x 2 cores
D-M9NW(V), D-M9PW(V)
0.15 mm2 x 3 cores
Note 1) Refer to catalogue for details of solid state switch with pre-wired connector.
Note 2) Refer to catalogue for solid state switch common specifications and for lead wire lengths.

Auto Switch Internal Circuit


D-M9NW(V)

Weight

Switch
main circuit

DC (+)
Brown
OUT
Black

DC ()
Blue

D-M9PW(V)

Unit: g

D-M9NW(V)

Auto switch part no.


Lead wire length
(m)

D-M9BW(V)

14

14

13

41

41

38

68

68

63

Dimensions

Unit: mm
3.2

D-M9W
DC (+)
Brown

Switch
main circuit

D-M9PW(V)

0.5

6 Most sensitive position


22

OUT
Black

Mounting screw M2.5 x 4 l


Slotted set screw

DC ()
Blue

Indicator light

2.6

2.7

4
Switch
main circuit

OUT (+)
Brown

2.8

D-M9BW(V)
22

D-M9WV

9.5

Indicator light / Display method

2.6

2.7
OUT ()
Blue

ON
OFF

Green

Red
Optimum operating
position

FOR MORE DETAILS


SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION

3.2

2
2.8

Display
Red

Slotted set screw

4.6

Mounting screw M2.5 x 4 l Indicator light

Operating
range

Most sensitive position


20

1221

Auto-Switch Guide

2-wire load current is reduced (2.5 to 40


mA).
RoHS compliant
UL certified (style 2844) lead cable is
used.
Flexibility is 1.5 times greater than the
conventional model (SMC comparison).
Using flexible cable as standard spec.
The optimum operating position can be
determined by the colour of the light. (Red
Green Red)

D-M9W/D-M9WV (With indicator light)

Contents - Auto Switch Guide Section

Water Resistant 2-Colour Indication


Solid State Switch: Direct Mounting Style

D-M9NA(V)/D-M9PA(V)/D-M9BA(V)
Auto Switch Specifications
Grommet

PLC: Programmable Logic Controller

Water (coolant) resistant type


2-wire load current is reduced (2.5 to 40
mA).
The optimum operating position can be
determined by the colour of the light.
(Red Green Red)
Using flexible cable as standard
specification

D-M9A(V) (With indicator light)


Auto switch model

D-M9NA D-M9NAV D-M9PA

D-M9PAV

D-M9BA

D-M9BAV

Perpendicular

Perpendicular

In-line

Perpendicular

In-line

Electrical entry direction

3-wire

Wiring type

PNP

Power supply voltage

5, 12, 24 VDC (4.5 to 28 V)

Current consumption

10 mA or less

28 VDC or less
40 mA or less

24 VDC (10 to 28 VDC)

2.5 to 40 mA

0.8 V or less at 10 mA (2 V or less at 40 mA)

4 V or less

100 A or less at 24 VDC


0.8 mA or less
Operating position .......... Red LED illuminates.
Optimum operating position .......... Green LED illuminates.

Leakage current
Indicator light

CE marking

Standard

Lead wires Oilproof flexible heavy-duty vinyl cable: 2.7 x 3.2 ellipse
D-M9BA(V)
0.15 mm2 x 2 cores
D-M9NA(V), D-M9PA(V)
0.15 mm2 x 3 cores
Note 1) Refer to catalogue for solid state switch common specifications.
Note 2) Refer to catalogue for lead wire lengths.

Fix the auto switch with the set screw


attached to the auto switch body. The auto
switch may be damaged if an unspecified
screw is used.

Weight

Unit: g

D-M9NA(V)

Auto switch model


Lead wire length
(m)

OUT
Black

14

14

13

41

41

38

68

68

63

Dimensions

Unit: mm

D-M9A

D-M9PA(V)

D-M9BA(V)

3.2

DC ()
Blue

D-M9PA(V)

0.5

DC (+)
Brown

0.2

Auto Switch Internal Circuit


D-M9NA(V)

Most sensitive position

M2.5 x 4 l

OUT
Black

Slotted set screw

Indicator light

DC ()
Blue

SMC

2.8

D-M9BA(V)
OUT (+)
Brown

2.7

Switch
main circuit

DC (+)
Brown

24

D-M9AV

OUT ()
Blue

OFF

Green

Red
SMC

2.8

Optimum operating
position

1222

Indicator light

2
4

Display
Red

M2.5 x 4 l
Slotted set screw

22

3.2

4.6

Operating
range

ON

Most sensitive position

Indicator light / Display method

9.3

2.6

Switch
main circuit

Auto-Switch Guide

24 VDC relay, PLC

Internal voltage drop

Precautions

IC circuit, Relay, PLC

Applicable load

Load current

Switch
main circuit

2-wire

NPN

Output type

Load voltage

Caution

In-line

2.7

Contents - Auto Switch Guide Section

Solid State Switch

With Pre-wired Connector


With Pre-wired Connector
Eliminates the harnessing work by cable with connector specifications
Adopts global standardized connector (IEC947-5-2)
IP67 construction

D- M9 P W V S A PC

Connector Specifications
Connector model

Connector model
3 wire, NPN
3 wire, PNP
2 wire

P
B

M83 pin
M84 pin
M124 pin

A
B
D

Wiring and output

Colour indication

0.5 m
1.0 m

Standard (1-colour)
W 2-colour
-

M124 pin

In-line
Perpendicular

Conformed standard

JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402

Impact resistance

300 m/s2

Enclosure

Wiring entry
V

M84 pin

Pin arrangement

Cable length
S
M

M83 pin

IP-67 (IEC529 standard)

Insulation resistance

100 M or more at 500 M VDC

Withstand voltage

1500 VAC 1 minute (between contacts), Leak current 1 mA or less

Connector Pin Arrangement


Colour distinction of lead wire

Sensor type

Meaning of contact number

1 pin

2 pin

3 pin

4 pin

1 pin

2 pin

3 pin

4 pin

DC 2-wire type

Brown

Blue

OUT (+)

OUT ()

DC 3-wire type

Brown

Blue

Black

DC (+)

DC ()

OUT

Weight
Unit: g

M8 connector type:

D-M9NAPC

Auto switch part no.


Lead wire length
(m)

D-M9PAPC

D-M9BAPC

D-M9NBPC
D-M9PBPC

D-M9BBPC

0.5

11

11

11

11

18

18

18

18

M12 connector type:

D-M9NDPC

Auto switch part no.


Lead wire length
(m)

D-M9BDPC

D-M9PDPC
0.5

19

18

26

25

Sensor section
31.4

FOR MORE DETAILS


SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION

M124 pin

14

M83 pin
4 pin

10

Dimensions

Sensor section
44

1223

Auto-Switch Guide

How to Order

Contents - Auto Switch Guide Section

Also Available Switches


Since

there are other applicable auto switches than listed, refer to Best Pneumatics catalogue for details.

Without indicator

2 color indication
Optimum operating position seen at a glance.

With diagnostic output


Displacement of the detecting position is
detected at the PLC side.

For light free enviroments.

ON

ON

Red

Green

Red

OFF

Optimun operating
position

Operating range

Auto-Switch Guide

With timer
(with OFF delay timer)

OUT OFF
(Normal output)

Operating range:
wide-area detection type

ON

OFF
ON

ON

Diagnosis OUT OFF


(Diagnostic output)

Operating range:
35 to 50 mm

OFF

OFF

Operating range

Optimum operating
position

Resistant to strong
magnetic fields

ON

Water, oil resistant


For water, coolant splash enviroments.

Can detect an intermediate position of a


high-speed cylinder.

For use in enviroments where AC current is


16,000A or more.

Heat resistant
For use in enviroments of 150C, 130C,
120C.

Before Operation

Auto Switches Connection and Example

Basic Wiring
Solid state 3-wire, NPN

Solid state 3-wire, PNP

Load

Main
circuit
of switch

Black

Blue

(Power supply for switch and load are separate)

Load

Main
circuit
of switch

Black

Load

Blue

Brown
Load

Main
circuit
of switch

Reed switch 2-wire


Brown

Brown

Brown

Brown
Main
circuit
of switch

Solid state 2-wire

Blue

Brown

Brown

Load

Blue

Blue

Blue

Main
circuit
of switch

Black

Load

Indicator
protection
circuit,
etc.

Indicator
protection
circuit,
etc.

~
Blue

Load

Example of Connection with PLC (Programmable Logic Controller)


Sink input specifications
3-wire, NPN
Black

Switch

Input

Brown

Source input specifications


3-wire, PNP
Black

Switch

Blue

Brown

COM

PLC internal circuit

2-wire

Input

Switch

Blue

Input

Brown

COM

PLC internal circuit

Switch

Blue

1224

Brown
Blue

COM

2-wire

Input

COM

PLC internal circuit

PLC internal circuit

Connect according to the applicable PLC


input specifications, as the connection
method will vary depending on the PLC
input specifications.

Trimmer Auto Switch

Series

D-Y7K/D-RK

Trimmer Auto Switch


Series

Series D-Y7K/D-RK

Features
Autoswitch with two separate outputs.
Used to detect different sizes of workpiece.
Switching positions can be adjusted by trimming screw.
Separate external amplifier with LED indicators.
Sensor part is IP67 for wet environments.

Auto-Switch Guide

Plug connection to amplifier.


Amplifier can be DIN rail mounted.
NPN and PNP output versions.

Selection
The D-Y7K can be specified in place of a D-M9*L in the
autoswitch guide. The mountings needed for each cylinder
type are unchanged. Don't forget to order an amplifier
for each switch.

OUT1 and OUT2 are


adjustable separately
OUT2 Trimmer

OUT1 Trimmer

Example
To confirm depth
of machined hole

To judge height
of work piece

Operating range of sensor (LED of sensor is on.)

OUT1 Detecting range

Output ON = Green LED is on.


Adjustable by trimmer

OUT2 Detecting range


Output ON = Orange LED is on.
Adjustable by
trimmer
Small work piece

Medium work piece

Large work piece

FOR MORE DETAILS


SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION

1225

Series

D-Y7K/D-RK

Trimmer Auto Switch

Specifications
Sensor unit
Model
Mounting

D-F7K

D-Y7K

Rail mounting

Direct mounting

Direct mounting type

D-RNK, D-RPK

Applicable amplifier unit


Status indication

Sensor unit

Operating position: red light is ON. Suitable operating position: green light is ON.
Grommet

Electrical entry

Rail mounting type

Oil proof vinyl heavy insulation cable 3.5 0.14 mm2 4 cores 3 m
With one e-con connector Note)

Lead wire
Impact resistance
Insulation resistance
Withstand voltage

980 m/s2
50 M (500 VDC) between lead wire and case
1000 VAC for 1 min. between lead wire and case
10 to 60 C

Enclosure

IP67

Weight

58 g (with connector)

Note) The e-con connector is not attached to the lead wire. They will be supplied loose in the same shipment.

Amplifier unit (with sensor unit)


D-RPK
D-F7K, D-Y7K

40 mA or less

Load voltage

NPN open collector Two outputs

PNP open collector Two outputs

28 VDC or less

Load current

80 mA or less

Internal voltage drop

1.5 V or less

Leakage current
Response time

Status indication

D-7K

100 A or less
1 ms or less
READY: Red light emitting diode when the piston position detected.
(When the sensor is connected).
OUT 1: Green light emitting diode when ON
OUT 2: Orange light emitting diode when ON

Electrical
entry

e-con connector Note)

Power supply/
output cable

Grommet

Impact resistance
Insulation resistance
Withstand voltage
Ambient temperature

Oil proof vinyl heavy insulation cable 3.5 0.14 mm2 4 cores 3 m
98 m/s2
50 M (500 VDC) between lead wire and case

White

Black

Note) Part number of spare connector assembly is: ZS-28-CA-3

DC (+)
(Brown)

4
3
2

OUT 1
(Black)

12 to 24
V DC

OUT 2
(White)
DC ()
(Blue)

D-RPK
Sensor
Brown
White

Black

70 g

1226

Sensor
Brown

10 to 60 C

Weight

SOUT 2 (White)

D-RNK

Blue

IP40

SOUT 1 (Black)

Amplifier unit

1000 V AC for 1 min. (between lead wire and case)

Enclosure

Vsw (Brown)

GND (Blue)

Detective
sensor

Blue

Connection
to sensor

Lead wire

Switch
main circuit

Load

12 to 24 VDC

Current consumption

Load

Power supply voltage


Output specification

Sensor unit

For relay and PLC

Application

Internal Circuit

DC (+)
(Brown)

4
3
2
1

OUT 1
(Black)
OUT 2
(White)
DC ()
(Blue)

12 to 24
V DC

Load

Applicable sensor unit

Load

D-RNK

Main circuit

Model

Main circuit

Auto-Switch Guide

Ambient temperature

Amplifier unit

Trimmer Auto Switch

D-Y7K/D-RK

Series

Specifications

D-F7K
10.6
3.2

2.5

Most sensitive position

M2.5 x 4L

SMC

4
7

12.5

3.5

Most sensitive position

SMC

8.5

15

D-Y7K

33

23

3000

Auto-Switch Guide

3.5

D-Y7K

6.2

6.2

11

3.2

D-F7K

0.4

Sensor unit

3000

4.6

Amplifier unit

21.1

D-RNK

30

D-RK

2-3.5
5

46

Connector for sensor


e-con
7.7

12.5

3000

56

OUT1

OUT2

READY

TRIMMER
SWITCH
SMC
3.5

12

8.6

2.6

DIN rail
DIN rail must be purchased individually.

Connector no.
1
2
3
4

Wire core colour


Black (SOUT1)
Blue (GND)
White (SOUT2)
Brown (Vsw)

FOR MORE DETAILS


SEE OUR SPECIFIC CATALOGUES,
PRODUCTS CDs OR ONLINE INFORMATION

Confirm that the numbers on the connector match the


colours of the wires and that the wires are inserted to the
bottom. Press part A by hand for temporary fixing.
Press in the central part of Part A vertically with a tool
such as pliers.
A sensor connector cannot be taken apart for reuse once it
is crimped. If the wire arrangement is incorrect or if the
wire insertion fails, use a new sensor connector.
Note: Spare connector part number: ZS-28-CA-3
4
2 3

Cut the sensor cable as illustrated to


Sheath 20mm or more
the right.
Referring to the table below, insert
each lead wire of the cable at the
position marked with a number
Insulator
corresponding to the colour of the
lead wire.

Connection of sensor connector

Part A

1227

Anda mungkin juga menyukai