PumpingConfiguration
Ideallysuitedtohighvolume,highload,difficultpumpingsystems.
Ultralongstrokeconfigurationallowshighestcapacityrodpumpingsystems(0Insto372Ins)
Longstrokesminimizerod,tubing,andpumpwearduetolesscyclesforthesamevolume.
Largestliftingcapacity(80,000lbs.)enablespumpinghighvolumesfromdeepwells.
Powerunitcanbedrivenbyelectricmotororgas/dieselengine.(25to200HP)
ManufacturedinISO9001certifiedfacilitiesinCanada.
Severaldifferentmodelstomatchwellproductiondesign
ProductionOptimization
Highlyintelligentsystem.
Canmatchpumpingconditionstowellproductivity.
Adjustmentstostrokelengthandstrokespeedareadjustablewhiletheunitisrunning,without
shuttingdown.
Upanddownstrokespeedcanbeindependent.
Accelerationforupanddowncanbeindependenttomaximizepumpfillage,andminimizerod
stress.
Adjustableloadlimits
Abilitytoremotelymonitoroperationstoreactquicklytooperatingconditions.Alarmsareuser
adjustableandarebuiltintotheintelligence.
Abilitytoanalyzewellpumpingconditionsviainternallygeneratedpumpcard.
Efficientoperation,resultinginlowerorequalpowerconsumptioncomparedtootherlift
systems,andsignificantlylowerpowercostscomparedtoESPs.
FieldOperations
Alladjustmentstooperationsaredoneonthepowerskid.Noroutineoperationsarerequired
atthepumpingunitandproductiondoesnotneedtobehalted
Abletospaceouttherodstringwithasimpleadjustmentwithouttouchingthepumpingunit.
Noneedtotouchthebridleorcarrierbar.
Safety
Noroutineoperationsarerequiredatthepumpingunit.Operatorsdonotneedtoaccess
movingparts.
Brakingsystemisinherentinthesystem.Nomechanicalinterventionisrequiredtofullylock
theunitsafely.
Counterbalanceisnitrogen,whichiseasilyadjustedratherthanlargesteelorconcreteweights.
Donotneedanypickersorcranestochangecounterweightsorstrokelength.
Noguywiresrequired.
Fewpinchpoints.
4timessafetyfactoronliftingcables.
TransportationandInstallation
Smallerandlighterdesignallowsforsignificantlylessshippingweight
Pumpingunitandpowerskidfitonasingletruck
Onetruckwithpicker,and2peoplecaninstallaunitin4hours.
Smallfootprintallowsminimumsitepreparation,andallowstighterwellheadpiping
configuration,ifrequired.
Maintenance
Extendstimebetweenworkoverssincelongerstrokeenableshighervolumewithfewer
rod/pumpcycles
Simpletomovebackfromwellheadforservicing.Unitselfalignswhenmovedbackintoservice.
Doesnotrequireanycranesortrucks.
Hydraulicsystemshaveproventoberobustinmultipleindustries,aroundtheworld,including
agriculture,mining,manufacturing,automotive,andaviation.
Welldefinedmaintenanceprogramrequiresfewerpreventativemaintenanceactions.All
maintenancecanbeconductedwithminimumdowntimelessthanfourhours
CommercialOver1,000installationsaroundtheworld
Competitivecapitalcost
Lowerinstallationcost
Bestinclasstotalcostofownership
Extendedwellruntime
Canprovidefullpumpingsystemincludingpump,rods,anchors,pumpbase,sandscreensetc.