Error number:
Error text:
H11ERR02
Singulator 1: device has not passed transit Singulator 1 > CS3 (Pre
CS1); H13IN01 was not interrupted by dropping device
Machine action:
None
Start possible if:
H11IN02 and H12/H13IN01 are free
Operator activity:
Check if Plunger is inserted correct
Check device for bent lead, damaged body or flash break and
remove device if necessary
Maintenance activity: In case of flash break check Vacuum cleaner for correct function
Sensor H13IN01 or fiber optics not adjusted correct or damaged
For Additional Info Press
S1
SIG
VCC
GND
E3X-A21
D
O
F
O
L F
N
O
O
O N
N
N
Fiber Optics
H11IN02
Singulator
H12/13IN01