Standard Designation:
Edition/Addenda:
Para./Fig./Table No:
Subject Description:
Date Issued:
02/06/2003
Record Number:
BC02-2819
Interpretation Number:
VIII-1-01-143
Question(s) and Reply(ies): Question: Is there a maximum holding temperature limit when postweld heat treating in
accordance with UCS-56 of Section VIII, Division l?
Reply: No; also see UCS-85.
1 of 1
Copyright 2016 by the American Society of Mechanical Engineers. No reproduction may be made of this
material without written consent of ASME