LS Busduct System

136 LS-ro, Dongan-gu, Anyang-si, Gyeonggi-do, 431-831, Korea


Tel. 031-428-4147 Fax. 031-428-4281

LS C&S Busduct System E-series~BTMS

Aug. 2014

To g e t h e r

2014 LS Cable & System, Ltd. All right reserved

Va l u e

LS C&S Busduct System E-series~BTMS

Gre a te r

Busduct System
E-series, Mini-way, LT-way, BTMS

About LS Cable & System


Since the separation from LG Electronics in 2003, LS Group has specialized in industrial energy, electronic energy, and industrial materials.
Thus, LS Group has achieved specialized global competitiveness in these fields. LS Group is a parent company of 40 subsidiary companies,
including LS Cable & System, LSIS, LS Nikko Copper, LS Mtron, Gaon Cable, E1 and Yesco. LS Cable & System holds the unrivaled position of the
top cable maker in Korea, and it provides total solutions for electronic power and telecommunication industries.

LNG, CNG

LS Cable & System has strived to become a global leader in the industry by implementing constant innovation since the establishment of the company.
While providing high-quality solutions to help our clients, LS Cable & System is accelerating efforts to be the top player of the global cable industry by securing
the top technologies in submarine cables and superconducting cables, as well as focusing on green business. Under the company vision
Your No.1 Creative Partner, LS Cable & System dedicates its best effort to deliver only the top technology and service to its clients.

Superior Essex
Supply of LPG for residential&commercial,
transportation,industrial and petrochemical uses in domestic market.
Import & Export of LPG etc.
LS Cable & System
LSIS
LS Nikko Copper
Gaon Cable

E1
Yesco
Superior Essex

Global Cable
Incorporated

Pountek
LG Electronics
LG Chemical

LS Global

Components, Machinery

LG Display
LG Telecom

Electrolytic Copper Cathode, Gold, Silver, Chemicals Product etc.


GS Caltex
GS Engineering & Construction

GS Retail
GS Homeshopping

Power equipment, Power supply & transmission, Industrial IT,


Automation equipment, Electric Power Tools, RFID etc.

A New Beginning as a Total Solution Provider for Electric Power and Telecommunications

Standing Tall as the Third Largest Cable Maker in the Global Cable Industry

History was made when LS Cable & System, the de facto holding company of LS Group, transformed into LS Holding Company in July 2008 and started as a new

In August 2008, LS Cable & System acquired Super Essex, the largest cable maker in North America, making LS Cable & System the third largest cable maker

total-solution provider specialized in electric power and telecommunications. It was the optimized business decision to increase management efficiency of the

in the global cable industry. By incorporating the staple product line of coils and communication wires of Superior Essex to the existing business structure

constantly expending business segments and to strengthen the responsible management system to foster a new growth engine to drive our business.

of power cables, optical fiber cables, and wires of the company, LS Cable & System has built an ideal cable product line. Securing the extensive experience

By separating investment and business segments, LS Holdings was able to discover a new growth engine to propel the group into a new phase of growth. The new

of production and distribution network of Superior Essex in the markets of North America and Europe has led to LS Cable & Systems emergence as a true

change of business provided an opportunity to the subsidiary companies to focus on their own operations and to strengthen their respective business expertise,

global enterprise.

as well as successfully enhancing the competitiveness in the industry. LS Cable & System, as the holding company, is committed to providing continued support to

Superior Essex In 1999, Superior Cable, which back then was a communication cable producer, made an acquisition of Essex Wire, a magnet wire producer,

the subsidiary companies, while practicing responsible management.LS Cable & System endeavor to focus on our core business while strengthening its business

and the combination formed Superior Essex. The company is the worlds largest maker of magnet wires and the largest maker of communication cables in

expertise and competitiveness as a global company.

North America. The company is headquartered in Atlanta, Georgia, USA, where they manage 24 factories in a total of 9 countries, including the United States,
Canada, Mexico, Germany, the UK, Italy, and China.

LS Cable & System


Busduct System Solution
Buildings
The LS C&S Busbuct system is easy to install, and ensures large capacity of
energy transmission while providing space efficiency which makes the bus
duct system ideal for high-rise buildings, office buildings, data centers and
apartment complexes.

Plants
The full lineup is consisting of NSPB, CAST RESIN and SIB that can cover up
to 27kv, and the lineup thus enables us to provide our clients customized
designs. The system is suitable for electrical rooms and power lines, and it
features a real time monitoring system using the temperature and power
monitoring system.

Data Center
The flexibility and expandability as well as easy maintenance property
of the busduct system provides the best alternative to improve the existing
problems of the conventional power cable system of data centers,
which requires constant extension, reinstallation and capacity
modification of loads.

Apartment Buildings
Although the demands for more electricity for families are growing,
the space for EPS area has reduced. Due to the change,
the need for busducts and multi boxes have increased.

Hospitals
The stability of the power supply in the hospitals is perhaps the most vital element,
because its failure could threaten the safety of patients.
The Busduct system distributes larger capacity of electric power, and provides
stability of the loads which make it an ideal choice to satisfy the requirements of
systematization of hospital complexes and larger hospital equipments.

Airports
In order to secure the stable power supply of the airport, the busduct system
provides the best customized solutions by installing high voltage busducts
at the transmission, transformation and power distribution lines, and by
installing low voltage busducts at the cargo, the control tower and general
commercial buildings.

Stadiums
The needs for a busducts system has been growing for its benefit such as
large capacity of power transmission, providing a stable power supply for
various loads and an eco friendly property as well as economical quality.

Marine & Wind


The compact and light weight design of the busduct satisfies the demands of the clients,
and comes with an outstanding quack resistance property. The busduct provides stability
to the operation of the facilities through a real-time monitoring system using
a temperature and power monitoring system. As the needs for renewable energy grows,
the demand for our busduct has been increasing teadily.

LS Cable & System Busduct Product


Line-up

The LS Cable & System Busducts are available in a wide range of products from low current capacity LT-way (25A~63A) to large current
capacity (630A~7500A), and the products enable the supply of proper capacity of power for factories and the distribution system. Our
products such as the air insulated bus conducts with enhanced safety property and the cast resin busducts with resistance for high
temperature, humidity and dusty environment will satisfy various application needs and provide a customized engineering service.

1
Riser Part

End Closer

Spring Hanger

Plug in Unit

Spring Hanger

Rigid Hanger

Rigid Hanger

3
Plug in Unit

Plug-in Box

4
Plug-in Box

4
6

Indoor

NSPB-LV/MV

Air Insulated Type/Insulated conductors separated by phase/AL,


STS and Steel Housing (optional)/Indoor Type/Outdoor Type

CR-LV/MV

SIB

Switchgear

Transformer

Air Insulated Type/ Compact NSPB Type / One-Bolting Type


Designed for low voltage products below AC 1000V, and between
1000A and 5000A

TR Flanged End Box

Outdoor

MS/Wind-way

Switchgear

TR Flanged
End Box

Transformer

Flat Wire Type/Copper Conductor with PVC Extruded Insulation/AL


Extrusion Housing/Various Plug Types/Joint Brush
(It can be installed with a live wire.)

- NSPB-LV : Designed for low voltage products below AC 1000V,and below 4000A
- NSPB-MV: Designed for high voltage products below AC 27kV, and below 4000A
- Suitable for plants where high stability is required.

Transformer

LT-way

- A Hybrid incorporating NSPB and sandwich type


- Ideal for ships, wind towers and chemical plants where stability is required.

2
7

Air Insulated Type/AL Extrusion Housing/Standard IP54/Joint Kit

- Designed for low voltage products below AC 690V, and between 25A and 63A
- Suitable for Light bulbs, FFU and distribution for small equipments

1
2

Horizontal Part
Plug in Unit

Plug-in Box

Mini-way
- Designed for low voltage products below AC 1000V, and between
160A and 800A.
- Ideal for small distribution system with multi distribution loads
(Vertical areas of buildings, data centers, assemble factories)

Spring Hanger

Spring Hanger

Sandwich Type (PET Film, Epoxy Coating, MICA)/AL


Extrusion Housing/Standard IP54/Joint Kit
- Designed for low voltage products below AC 1000V, and between
630A to 7500A.
- The most widely used conventional model.

End Closer

Plug-in Box

Ez/Ex/Ef-way

- Cast Resin Type/IP 68/Epoxy Molding between Conductors


- CR-LV: Designed for low voltage products below AC 1000V, and between
630A and7500A.
- CR-MV: Designed for high voltage products below AC 27KV,
and below 5000A.
- The most safe bus duct suitable for plants where high stability is required.

Epoxy Vacuum impregnated insulation Products/Suitable for phase


separation system
- Designed for high voltage products below AC 27kV and below 7500A
- Small space , bending area
- Suitable for high voltage products.

Why Busduct?
Easy Distribution of Loads

Adaptability to various installation


environment with convenience

When supplying power using cables, each load has to be connected individually to cables which waste space,
and an additional distribution panel is also required.
On the other hand, busducts are separated from a single line at a plug box which simplifies the electric power system.
A MCCB can be installed at the plug box to effectively shut off fault current.

Cable Wiring System

Busduct Wiring System

P-x

P-x

L-x

L-x

P-x

P-x

L-x

L-x

P-...

P-...

L-...

L-...

P-...

P-...

L-...

L-...

P-3

P-3

L-3

L-3

P-3

P-3

L-3

L-3

P-2

P-2

L-2

L-2

P-2

P-2

L-2

L-2

P-1

P-1

L-1

L-1

P-1

P-1

L-1

L-1

ACB

ACBMCCB

The busduct system is a power distribution system and can


be applied to various complex routes. The busduct system
comes with various fittings such as elbow, off-set and tee,
and can transmit high capacity currents without electrical
and mechanical loss.

ACB
MCCB

ACB

ACB

One to-one correspondence of power


supply and loads
Additional lines are needed in case of a
load change

ACB
ACB

Excellent short circuit


The busduct system has a high tolerance for short circuit.
Its stability and reliability make it perfect for a high capacity
energy transmission system.

ACB

One to-many correspondence of power


supply for specific power supply
Additional lines are not necessary in case
of a load change

ACB : Air Circuit Breaker, MCCB : Molded Case Circuit Breaker

High current density


Easy Installation

0.2

Pulling and cable tray installation for cables can be difficult, and
requires a longer construction period, therefore increases the
cost. On the other hand, the busducts use a simple installation
method to connect specific length of products, which requires a
shorter installation period, and is economically friendly.

0.6

1.0

1.4

1.8

2.2

2.6

Labor Hours
3.0 3.4 3.8

Cables are connected directly to electric loads using racks.


Its maximum allowable current ampacity limit is 1000A, and
requires additional lines for a higher current. Each line of
the busduct system can transmit up to 7500A, and provides
high current density.

800
1000
1500
2000
2500
3000
4000
Ampere

Busduct

Cable

Easy maintenance
The design of the busduct system makes it easy to detect
abnormalities during installations, and ensures easy maintenance. When humidity or dust causes a malfunction on
the system, the easy-to -maintain design allows replacing
only the damaged part.

Compact
The compact design of the busduct system provides high space efficiency at up to 50% compared to the cables.
While cables require larger space to install multi lines as well as additional space for coiling areas, the busducts use
proper fittings to maximize space efficiency.

Cable

Cable Tray

The space
required reduces

by 50%

R
S
T

Outstanding features of
EMC and EMI
Unlike cables, the busduct system does not require a shield,
instead Busduct, the housing itself performs as a shield
which enhances the features of EMC and EMI.

Why LS Cable &System Busduct


Total Solution

Global Top Tier


LS Cable & System has been a long-time leading Busduct provider in korea. With extensive experience and product line competitiveness, the company provides total solutions for each application to satisfy the needs of its clients. Using its expertise in
the electronic markets of large LCD monitors and semiconductors in Korea, the company has obtained PJT sales records in 50
countries worldwide in Asia, the Middle East, CIS, and America.

Once PJT launches, our engineer will participate to guide the clients from the initial period in order to produce the best
system for our clients, and to respond quickly when the system is changed.
Our engineers from each department provide full support in design, production, installation and testing at in-bound to
satisfy our clients.
We operate the CS Team, a task force for the busduct system, to make sure efficient after-sale service and maintenance
service.

Process
Desi
gn
an

les

ent
lopm
eve
dD

Sa

PJT Kick O

Full Line up

ua
lity
/

System design

cti
on

Customer Service
Product test and
installation support
PJT management

/Q
tion
Installa

LS Cable & System


Busduct
Total Solution

Provide technical support


for the clients
Product development

CS

d
Pro

Production

LS Cable & System is the only global company that provides a full line-up of busducts, from low to high voltage and from low
to high capacity, to satisfy every need of its clients and provide an optimized solution for each PJT.

Technical Excellence
LT-way
MS/Wind-way

Mini-way
Ez / Ex / Ef-way
CR-LV/MV

Unparalleled Reliability

Total Engineering Technology

Provides standardized design, and owns numerous certifications


such as UL Certification, Quack Proof Certification, and Impact
Resistance Certification
The CS team, a task force for the busduct system,
provides efficient after-sale service
Safe use in hazardous zones
Manage the system using a unique temperature
monitor sensor
Semi-permanent service life
Used qualified insulation such as epoxy and PET film
for efficient insulation

Provide the optimal design by experienced engineers


Design following analysis and inspection of CAE
Unique and exclusive design program for the busduct system
Design based on structure stability inspection
The excellent heat radiating property of the aluminum housing, which
ensures large capacity of power transmission
Low Weight & Low cost
Easy installation
Deployable where access is difficult
Automated epoxy insulation facility
Unique joint kit connections
Reduce electromagnetic
BPMS (Busduct Power Monitoring system)
BTMS (Busduct Temperature Monitoring system)

Eco friendly
SIB (MV)
NSPB -LV/MV

Fully recyclable
Halogen free
Does not contain RoHS 6 hazardous substance
No toxicity in fire & Fire-Retardant
Non Explosive

Ez/Ex/Ef-way

The Busduct Temperature Monitoring System


(BTMS : Busduct Temperature Monitoring System)

LS C&S Busbuct System Catalogue

The busduct is a large capacity power distribution system. The insulation of the duct has to stay stable when the Joule lines
occur during a power supply of the conductor. The rated current will be set by the insulation type and the temperature rises.
These properties of the busduct make it possible to monitor and manage abnormalities of the system by checking the
temperature of specific areas of the system.

01 of 08

The temperature monitoring system uses various temperature sensors such as optical fiber cable, IC electric chips and
thermo-graphic cameras. Specific areas like the entire system line, joints, plug-in boxes and cable connection can be
monitored at the central monitor room using various methods on request.

Contents
The Busduct Power Monitoring System
(BPMS : Busduct Power Monitoring System)
The ongoing trends of the busduct system are more than a simple power supplying system. The growing trend is; 1) the stability of
the power system, 2) unmanned system,3)cost cutting, and 4)green and smart grid. While the SCADA system monitors and controls
the power of the main system, the BMS monitors low loads of the sub system. The frequency of the resent electrical accidents is
higher at the sub system than at the main system. Therefore, the preference for the BMS system has been increasing.
Smart box

Communication Unit

Ethernet

Optical
Communication

<Monitor Program>

Ethernet

RS-485

I. Introduction
- Overview
- Application

14
15

II. General Data

16

III. Component
- Feeder
- Flanged End
- Fittings
- Hanger
- Plug-In Unit
- Etc

22
23
26
29
31
33

IV. Technical Data


- Impedance
- Voltage Drop
- Temperature Rise

35
35
37

V. Install Information
- Joint Connection

38

VI. Certification & Specification

39

I. Introduction

Overview
The LS C&S E-Series Busducts are designed to carry voltage range below AC 1000V, and to carry the current range of 630A to 7500A.
Joint kit connections provide more space to connect which reduce the contact resistance to its minimum while connecting products.
LS C&S E-series Busduct comes with a standard IP54rating; however, it can be upgraded to an indoor or outdoor IP65 rating on request.
Depending on each insulation property, the system comes in three types; Ez-way when polyester film is used,
Ef-way when mica film is used and Ex-way is used when epoxy powder is used.

Application
Electrical Rooms

E-series

The E-Series

06 / 07

The busduct can be installed both horizontally and vertically


at the electrical room.
The maximized safety features are seismic-proof and
explosion-proof.
Provides excellent space efficiency and easy installation
compared to cables.

Compact Size
LS C&S E-Series Busduct uses an effective heat radiating housing profile which allows the size of the conductors to be smaller
than the existing Busduct models. The light weight of the Busduct also allows easier installation and requires less space.

Economical and Easy Installation


LS C&S E-Series Busduct uses aluminum housing and joint kit
connections which enable easy installation with less time and low cost.

Easy Distribution of Loads

Commercial / Housing Building etc.


Provides excellent space efficiency.
The busducts can be applied to high-rise buildings,
office buildings, and data centers.
Multi-box can be applied on request.

LSC&S E-Series Busduct can directly distribute the loads at the


plug-in box using a single line, and thus simplifies the power
supply system. The MCCB can be installed in the plug-in box
on request to effectively shut off the faulty current.

Factory / Plant etc.


The busducts can be applied to a vast range of industries such as
semiconductor, display and petrochemical plants.
The temperature and the power supply monitoring system allows
easy maintenance.
The busducts provides high space efficiency, and allows
a significantly reduced installation period.

14

E-series LS C&S-Busway System

E-series LS C&S-Busway System

15

. General Data

06 / 07

End Cap
Plug-in Box
Offset
E-series

Elbow

Connection
Joint Cover

Option I : Joint Kit

Option I I : One Bolting

Flanged End
Feed in Unit

16

High Current Density

Eco - Friendly

Conductors

Housing

The busduct has a compact design compared to the


existing models by using an effective heat-radiating
housing profile and can carry from 630A up to 7500A
with reduced loss of electric power. It is an ideal power
distribution system that provides high efficiency,
stability, economy-friendliness and convenience. The
design of the conductor allows flexibility to extend
and relocate depending on the environment.

The LS C&S Busbucts acquired RoHS certification,


and only uses components without hazardous
substances such as lead, cadmium, mercury,
chrome, PBBs and PBDEs.

The E-Series uses either copper conductors with


conductivity over 99%, or aluminum conductors
with conductivity over 61%.

The E-Series uses an effective heatradiating


aluminum housing profile which produces an
excellent mechanical strength and heat radiation.
The aluminum housing can be used as a protective
conductor(PE) due to its high level conductivity and
cross sectional areas. An optional optical fiber temperature sensor can be installed at the housing.

Low Voltage Drop and High


Short Circuit Strength

Standard

The connection of the conductors is tin-plated in


order to reduce contact resistance and to prevent
corrosion of the connection. (A silver plated option
is available.)

Thanks to the optimum design, power can be


transmitted with the greatest possible efficiency,
and the resultant voltage drop is low due to extremely
low impedance. In addition, the LS C&S Busducts is
designed to have very high short circuit strength.

IEC 61439-1 [(previous standard)IEC 60439-1]


Power Switch gear and Control gear Assemblies
IEC 61439-6 [(previous standard)IEC 60439-2]
Busbar Trunking Systems
NSEN 60439 Busways
NEMA BU 1.1 Busways

Permissible Operating Temperature

Service Condition

The cross sectional areas of the conductor and


housing profile are designed to meet the standard
permissible operating temperature of IEC 61439-1
and 6. Therefore the temperature rise limit of
the housing is within 55K or less of the ambient
temperature.

o
o
Ambient Temperature : -15 C ~ 55 C
Relative Humidity : 95% or below
(When the service condition of the environment
does not meet the requirements listed above, please
contact our design team.)

E-series LS C&S-Busway System

Insulation Properties

Connection
o

An insulator of thermal class rating Class B (130 C ) or


more is applied to the E-Series. Other insulation
options such as Epoxy, PET and MICA (Fire proof
o
up to 1200 C) are also available. FRP (Fiber Reinforced
Plastic) with high dielectric property is used as
insulation at the connection which performs as
insulation between phases and housing.

Kit : DH (dual head) bolts and Visible-label (Redtag)


Check for installation using the contact
To exert a uniform force on the entire connection can Disc
Spring A structure. (Assembly Torque 800 ~ 1000kgf.cm)
One-bolting : One-bolting without a Feeder Kit Part
of the structure is directly connected to the conductor,
Kit with the same DH (dual head) bolts and Visible-label
(Red-tag) to Check for the installation and use of all
contacts Connection can apply a uniform force to
the Disc Spring A structure. (Assembly Torque 800 ~
1000kgf.cm)

E-series LS C&S-Busway System

17

. General Data

06 / 07

General Specifications

Joint Connection

E-series Busduct uses insulation with a thermal class rating over130 oC for each phase. A sandwich type design is applied to
the Busduct to protect the aluminum housing, and it can be used at the voltage range of AC 1000V or less, and the current
range between 630A to 7500A. It is designed to use a joint kit connection and general IP54 rating.

Feature

Fastening Bolt & Washer


Conductor(Copper / Aluminum)

E-series

Extruded Aluminum housing coated with paint

Both joint plates of the joint kit and the conductors are tin plated. (A silver plated option is available.)
It prevents the joint plate from discoloration and corrosion. In order to ensure easy maintenance
and reliability, double-headed bolts and visible labels are used to check the application,
and a disc spring allows even connection of the contact surface.

Double Headed Bolts


Double-headed bolts are used to ensure a proper torque level when installing the joint kit.
If a torque wrench applies a pressure of 800 to 1000kgfcm to the outer bolt head,
the head of the outer bolt and the tag attached to it will be sheared off automatically.
Thus, it allows visual inspection for the proper application of the bolts at the connection.
The remaining bolt head can be re-used when tightened to 800kgf . cm using a torque wrench.

Insulation
- Ex-way by EPOXY
(Class B 130oC / Class F 155oC)

<Option : Joint Kit>

<Option : One Bolting>

- Ez-way by PET
(Class B 130oC / Class F 155oC)
- Ef-way by MICA (1200oC)

Number of Double headed bolts


Number of
D.H bolts
Ampere
(A)

CU

630, 800, 1000,


1250, 1600, 2000

2500, 3200,
3600, 4000

5000

6300, 7500

AL

630, 800,
1000, 1250

1600,
2000, 2500

3200,
3600, 4000

5000, 6300

Precaution

Be sure to clean the interior of the connections prior to installation. Use caution not to twist the joint kit while inserting it, and after it is inserted.
An excessive pressure during installation may break the kit.
Make sure that the double-headed bolts and the red tags are intact.
If proper torqueses are not applied at the connection, it may cause heat during operation.

18

E-series LS C&S-Busway System

E-series LS C&S-Busway System

19

. General Data

06 / 07

Grounding and Harmonics

IP Code (Degree of Protection)

E-Series Busduct comes with aluminum housing, and the cross-section area of the housing is over 100% of each
phase conductor. Therefore, the aluminum housing alone works as 100% or more of ground bar, and the housing also
improves the heat radiation of the conductors.

International protection degree codes provided by IEC 60529(Degree of Protection Provided by Enclosure-IP Code)
* As the standard differs, it is a similar substitution, not 1:1 substitution.

The degree of protection against water of the LS C&S E-Series is a standard IP54; however, it can be adjusted from IP42
to IP65 depending on the environment and on request.

IP
Solid Particle Protection

[4W+GE]

[4W(200%N)+GE]

No Protection

0 No Protection

Protection against 50mm


diameter solid particles.
(back of a hand)
Protection against 12mm
solid particles. (fingers)

Protection against
falling drops of water.

Protection against
low pressure jets of water
from all directions.

Protection against falling


drops of water with an
enclosure tilted at a 15degree
angle from a vertical line

Protection against
strong jets of water
from all directions.

Protection against
spray sat a 60degree
angle from a vertical line

15cmmin.

Protection against the effects


of immersion between
15.0 centimeters and 1.0 meter.

Protection against
water splashed from
all directions.

1m

Protection against
longer periods of immersion
under pressure.

3
4

[3W+50%E, 100%E]

[4W+50%E, 100%E]

[4W(200%N) + 50%E]

Liquid Ingress Protection

[3W+GE]

E-series

The 200%N type Busduct is used for a nonlinear load that generates harmonic current. Lately, the needs for non-linear loads at the power distribution
system of buildings are increasing due to the increase of office automation and computer facilities. The harmonic current produced by the system can
flow up to 200% of over current at phase N. The LS C&S 200% N type busduct is safe to be used at the distribution system where the harmonic current
can be generated.

NEMA STANDARD : IP54=NEMA 12, 12K, 13 IP55=NEMA 3, 3X, 3S, 3SX IP66=NEMA 4.4X IP67=NEMA 6

Protection against 2.4mm


solid particles.
(tools or thick wires)
Protection against 1mm
solid particles.
(tools or most wires)

Protection against dust.

Complete protection
against dust.

1m

Degree of Protection IP54 / IP55

Degree of Protection IP65 / IP66

IP54 is applied to the feeder, plug-in and tap-off, and can be


used during water leakages and near sprinklers.

With the IP65 rating, the busduct is ideal for corrosive environments.
The special sealing between the housing sections seals off water,
dust and gasses.

Plating/Coating
Plating

Coating

Standard tin plating is applied at taps, plugs and connections


of conductors using an electroplating method to maintain the
electrical characteristics and to prevent corrosion. Silver plating is
available on request.

In order to improve heat radiation and to prevent corrosion, as


well as to fit in with the surroundings, we apply polyester-epoxy
(hybrid) power coating after treating the surface. A wide range of
color is available to meet the needs of our clients.

Indoor and Outdoor Type

Indoor Type

Outdoor Type

IP Code
Degree of Protection
(IP)
IP54 / IP55

Busbucts

Construction Type

Feeder, Plug-in, Riser

Drip-proof / Splash-proof

IP65 / IP66

Feeder

Water Jet-proof

*Outdoor applications require advanced discussion with the design team.


20

E-series LS C&S-Busway System

E-series LS C&S-Busway System

21

. Component

06 / 07

Feeder

Flanged End

Sectional View

Flanged end is connected to either a transformer or panel. Dimension details are listed below.
AA

Flanged End(GE)

WW

WW

Flange(AL 4t)

Flange(AL 4t)

Flange(AL 4t)

Flange(AL 4t)

Flange(AL 4t)

Flange(AL 4t)

H
H

Flange(AL 4t)

tt

HH

3434

Flanged End(50%, 100%E)

Flange(AL 4t)

E-series

AA

[Fig. E1-1]

[Fig. E1-2]
[Fig. E2-1]

A
A
W
W

34
34

34
34

[Fig. E1-3]

Ampere(A)

AL

CU

630
800
1,000
1,250
1,600
2,000
2,500
3,200
3,600
4,000
5,000
6,300
630
800
1,000
1,250
1,600
2,000
2,500
3,200
3,600
4,000
5,000
6,300
7,500

Dimension(mm)
t

6.35

6.35

W
41
62
86
108
164
210
(2)126
(2)164
(2)184
(2)210
(3)184
(3)210
41
41
57
73
108
145
195
(2)108
(2)126
(2)145
(2)195
(3)164
(3)195

Weight(kg/m)
A
107
128
152
174
230
276
352
428
468
520
686
764
107
107
123
139
174
211
261
316
352
390
490
626
719

* H : 107.5(3W+GE, 3W+50%E) / 115(4W+GE, 4W+50%E) / 125(4W+100%E)


22

E-series LS C&S-Busway System

[Fig. E2-2]

3W
7.58
8.83
10.92
13.40
19.57
23.08
28.94
34.86
38.31
41.81
57.74
64.03
11.91
11.91
14.65
17.65
26.74
31.69
42.69
50.16
57.55
64.82
85.26
108.91
126.89

4W
8.43
10.09
12.14
15.42
20.61
26.23
33.18
42.44
45.40
50.10
68.43
73.61
14.44
14.44
18.25
22.04
31.00
37.39
54.59
63.60
73.16
82.72
109.14
139.27
162.81

4W+50%E
8.79
10.63
12.89
16.36
22.08
28.14
35.38
45.29
48.59
53.75
73.22
81.51
15.65
15.65
20.58
24.60
36.47
44.76
60.25
69.87
80.41
91.17
121.08
154.65
179.83

4W+100%E
9.15
11.17
13.64
17.30
23.55
30.09
37.58
48.14
51.78
57.40
78.01
89.41
16.86
16.86
22.91
27.16
41.94
52.13
65.91
76.14
87.66
99.62
133.02
168.02
196.85

Fig.

Ampere(A)

E1-1

AL
E1-2

E1-3

E1-1

CU

E1-2

E1-3

630
800
1,000
1,250
1,600
2,000
2,500
3,200
3,600
4,000
5,000
6,300
630
800
1,000
1,250
1,600
2,000
2,500
3,200
3,600
4,000
5,000
6,300
7,500

[Fig. E2-3]

[Fig. E2-4]

[Fig. E2-5]

Dimension(mm)
t

6.35

6.35

W
41
62
86
108
164
210
(2)126
(2)164
(2)184
(2)210
(3)184
(3)210
41
41
57
73
108
145
195
(2)108
(2)126
(2)145
(2)195
(3)164
(3)195

A
~
~
40
50
60
70
40
60
60
70
60
70
~
~
~
40
50
50
70
50
40
50
70
60
70

Fig.
E2-2

100

E2-3
E2-5
E2-4

130

E2-5

E2-2
100

E2-3
E2-4
E2-5
E2-3
E2-4

130
E2-5

*T: Conductor thickness


E-series LS C&S-Busway System

23

. Component

06 / 07

Flanged End
Drilling Pattern for Flanged End

Flanged End Box / Feed in Box


E-series

D
A

B
A

[Fig. E4-1]

D
B
D

C1

25 25

C1

C2

[Fig. E3-1]

Ampere(A)

AL

CU

24

630
800
1,000
1,250
1,600
2,000
2,500
3,200
3,600
4,000
5,000
6,300
630
800
1,000
1,250
1,600
2,000
2,500
3,200
3,600
4,000
5,000
6,300
7,500

E-series LS C&S-Busway System

B
122
143
167
189
245
291
367
443
483
535
701
779
122
122
138
154
189
226
276
331
367
405
505
641
734

25 25

C2

C1

[Fig. E3-2]

3W Dimension(mm)
A
240
240
240
240
240
240
300
300
300
300
300
300
240
240
240
240
240
240
240
300
300
300
300
300
300

C1, C2
110
110
110
110
110
110
140
140
140
140
140
140
110
110
110
110
110
110
110
140
140
140
140
140
140

A
340
340
340
340
340
340
430
430
430
430
430
430
340
340
340
340
340
340
340
430
430
430
430
430
430

B
122
143
167
189
245
291
367
443
483
535
701
779
122
122
138
154
189
226
276
331
367
405
505
641
734

C2

[Fig. E3-3]

4W Dimension(mm)
D
152
173
197
219
275
321
199
237
257
283
244
270
152
152
168
184
219
256
306
181
199
218
268
224
255

25 25

C1, C2
160
160
160
160
160
160
205
205
205
205
205
205
160
160
160
160
160
160
160
205
205
205
205
205
205

[Fig. E4-2]

4W+50%E, 100% E Dimension(mm)


D
152
173
197
219
275
321
199
237
257
283
244
270
152
152
168
184
219
256
306
181
199
218
268
224
255

A
410
410
410
410
410
410
500
500
500
500
500
500
410
410
410
410
410
410
410
500
500
500
500
500
500

B
122
143
167
189
245
291
367
443
483
535
701
779
122
122
138
154
189
226
276
331
367
405
505
641
734

C1
230
230
230
230
230
230
275
275
275
275
275
275
230
230
230
230
230
230
230
275
275
275
275
275
275

C2
160
160
160
160
160
160
205
205
205
205
205
205
160
160
160
160
160
160
160
205
205
205
205
205
205

D
152
173
197
219
275
321
199
237
257
283
244
270
152
152
168
184
219
256
306
181
199
218
268
224
255

Fig.

Ampere(A)

E3-1

AL
E3-2

E3-3

E3-1

CU

E3-2

E3-3

630
800
1,000
1,250
1,600
2,000
2,500
3,200
3,600
4,000
5,000
6,300
630
800
1,000
1,250
1,600
2,000
2,500
3,200
3,600
4,000
5,000
6,300
7,500

3W Dimension(mm)
A
347
368
392
414
470
516
592
668
708
760
926
1004
347
347
363
379
414
451
501
556
592
630
730
866
959

B
297
318
342
364
420
466
542
618
658
710
876
954
297
297
313
329
364
401
451
506
542
580
680
816
909

C
410
410
410
410
410
410
470
470
470
470
470
470
410
410
410
410
410
410
410
470
470
470
470
470
470

D
180X2
180X2
180X2
180X2
180X2
180X2
210X2
210X2
210X2
210X2
210X2
210X2
180X2
180X2
180X2
180X2
180X2
180X2
180X2
210X2
210X2
210X2
210X2
210X2
210X2

4W Dimension(mm)
L
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270

A
347
368
392
414
470
516
592
668
708
760
926
1004
347
347
363
379
414
451
501
556
592
630
730
866
959

B
297
318
342
364
420
466
542
618
658
710
876
954
297
297
313
329
364
401
451
506
542
580
680
816
909

C
510
510
510
510
510
510
600
600
600
600
600
600
510
510
510
510
510
510
510
600
600
600
600
600
600

D
230X2
230X2
230X2
230X2
230X2
230X2
275X2
275X2
275X2
275X2
275X2
275X2
230X2
230X2
230X2
230X2
230X2
230X2
230X2
275X2
275X2
275X2
275X2
275X2
275X2

4W+50%E, 100% E Dimension(mm)


L
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270

A
347
368
392
414
470
516
592
668
708
760
926
1004
347
347
363
379
414
451
501
556
592
630
730
866
959

B
297
318
342
364
420
466
542
618
658
710
876
954
297
297
313
329
364
401
451
506
542
580
680
816
909

C
580
580
580
580
580
580
670
670
670
670
670
670
580
580
580
580
580
580
580
670
670
670
670
670
670

D1
300
300
300
300
300
300
345
345
345
345
345
345
300
300
300
300
300
300
300
345
345
345
345
345
345

D2
230
230
230
230
230
230
275
275
275
275
275
275
230
230
230
230
230
230
230
275
275
275
275
275
275

L
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270
270

E-series LS C&S-Busway System

25

. Component

06 / 07

Fittings

Elbow

Offset

[Horizontal]

[Horizontal]

Combination
Dimension(mm)

Ampere(A)

AL

CU

630~1,250

500

500

500

1,600~3,200

600

600

600

3,600~4,000

700

700

700

5,000~6,300

800

800

800

630~2,000

500

500

500

3,000~4,000

600

600

600

5,000~6,300

700

700

700

7,500

800

800

800

E-series

E-Series Busduct has a wide range of fittings to satisfy any layout of buildings. Elbow angles other than 90 o are also available.
Fitting designs are shown in the following figures, and they consist of the source-side and the load-side. Offset or
combination elbows can be used where standard elbows are not feasible.
(Dimensions for each fitting are shown in the following figures. Contact our design team for a minimum dimension.)

Tee
[Vertical]

[Vertical]

[Horizontal]

[Vertical]
600
600

600
600

600
600
600
600

600
600

Vertical Elbow
Ampere(A)

AL

CU

26

630~1,250

500

500

1,600~3,200

600

600

3,600~4,000

700

700

5,000~6,300

800

800

630~2,000

500

500

2,500~4,000

600

600

5,000~6,300

700

700

7,500

800

800

E-series LS C&S-Busway System

Vertical Tee

Vertical Offset
Dimension(mm)

Ampere(A)

AL

CU

600
600

Dimension(mm)

Dimension(mm)

Ampere(A)

630~1,250

500

500

500

1,600~3,200

600

600

600

700

700

700

800

800

800

500

500

500

3,000~4,000

600

600

600

5,000~6,300

700

700

700

7,500

800

800

800

630~1,250

500

150

500

1,600~3,200

600

150

600

3,600~4,000

700

150

700

3,600~4,000

5,000~6,300

800

150

800

5,000~6,300

630~2,000

500

150

500

630~2,000

3,000~4,000

600

150

600

5,000~6,300

700

150

700

7,500

800

150

800

AL

CU

E-series LS C&S-Busway System

27

. Component

06 / 07

Fittings

Hanger

Expansion

Vertical Mounting Hangers

The fitting is designed to allow a 60mm extension of a straight line.

630~7,500

1,500

360

E-series

Dimension(mm)

Ampere(A)

Spring hangers are used to support the busducts between floors. The number of springs depends on the weight of the installed busduct and plug-in
boxes. A medium hanger should be installed if the height between the floors exceeds 4.5 meters, and the height of the installed spring hangers can be
easily adjusted. Rigid hangers (no spring type) are used on the lowest floor, and they can be used instead of spring hangers depending on the set up
design.

Reducer
A reducer is used to connect a large capacity busduct to a small capacity busduct.
It can be used for an economical setup to distribute loads.

Primary

Ampere(A)
Secondary

1,000

Dimension(mm)
X

[Rigid Hanger]

[Spring Hanger]

Rigid Hanger

630~800

1,250

800~1,000

1,600

1,000~1,250

2,000

1,250~1,600

2,500

1,600~2,000

3,200

2,000~2,500

4,000

2,500~3,200

5,000

3,200~4,000

6,300

4,000~5,000

7,500

5,000~6,300

1,000

*Any change made to load distribution or to capacities follows inner line regulations. An overcurrent circuit
breaker can be installed on request.

[1 Row]

[2 Row]

[Side View]

[2 Row]

[Side View]

Spring Hanger

Phase Transposition Feeder


A phase transposition feeder is used when the setup transforms
the phase.

[1 Row]

* Hangers with more than 2 rows depending on the installation environment are also available on request.
Please contact the design team for further information.
28

E-series LS C&S-Busway System

E-series LS C&S-Busway System

29

. Component

06 / 07

Plug-in Unit

Horizontal Hangers

Straight Lengths: Plug-in/Tap-off Intervals

General Hangers

This busdust comes with an overcurrent blocking device (MCCB, fuse) in order to protect the wires while distributing loads.
The required minimum intervals of a plug-in(800A or less)and a tap-off(1000A, 1250A) are shown below. A length longer than
the required minimum intervals can be predestinated on request.

The standard installation method for these hangers is to install them horizontally at 1.5 meters intervals. They generally require 12mm diameter stud bolts.

[Flatwise]

[Edgewise]
Hanger Rod

Hanger Rod

Hanger Clamp
Hanger Clamp

Spring Nut

Spring Nut

Plug-in Feeder
MCCB Frame
(AF)
50, 65, 100
250
400
630, 800
1000, 1250

Wall brackets can be installed on a wall where general hangers are not feasible.

[Edgewise]

50, 65, 100


250
400
630, 800
1000, 1250

D
H

Hole Pitch (P)

MCCB Frame
(AF)

[Flatwise]

Plug-in Hole Intervals(P)


(mm)
650
650
900
1000
1300

Plug-in Box

Wall Bracket

E-series

Hanger

Dimensions(mm)
W
3W
200
200
250
350
400

4W
250
250
300
400
450

220
220
220
220
220

450
450
750
800
1200

Fig.

E5-2
E5-3
[Fig. E5-1]

[Fig. E5-2]

30

E-series LS C&S-Busway System

[Fig. E5-3]

E-series LS C&S-Busway System

31

. Component

06 / 07

Etc.

Plug-in Box Attachments

Wall Flange

Attachments such as CT, TD and PT can be installed in a plug-in box to control and to supervise the current,
voltage and wattage remotely.

A wall flange is used to seal the gaps produced during installation of busducts at the walls, ceilings and floor. The standard
dimensions of a wall opening should be 30mm larger than the external dimensions of the E-Series Busduct.

Door Types of the Plug-in Unit

E-series

Plug-in Unit

Wall Flange

Wall Flange

Various design of doors for the plug-in box is available to satisfy the demands of our clients.
The available types are shown below.

Glass Wool(out of scope)


Fire Foam(out of scope)

External handle

Push Button

External lever interlock

Floor Openings
The standard dimensions of a floor opening should be 30mm larger than the external dimensions of the E-Series Busduct.

Bolt Fastening

32

E-series LS C&S-Busway System

Key Lock

Outlet

E-series LS C&S-Busway System

33

Component

. Technical Data

Etc.

Technical Data

The Required Minimum Distances from a Wall for Heat Dissipation

Impedance and Voltage Drop

The required minimum distances between a busduct and a wall, or a ceiling are shown below.

The formula to measure the voltage drop of a busduct is shown below. The impedance and voltage drop values for aluminum
and copper conductors are shown in the table below.
The values listed are measured between upper and middle lines at 60Hz. For a 50Hz installation, multiply the reactance (X) by 0.83.

wall , ceiling

250mm

ceiling

100mm

BEAM

wall

100mm

200mm
wall

wall

Vd = I x 3(R cos + X sin)


Vd = voltage drop[V] I = rated road amperes[A] R = resistance[] X = reactance[] / cos = power factor / sim = reactive factor

wall

100mm
100mm

100mm

E-series

wall , ceiling

06 / 07

joint

Actual voltage Drop = x Vd x

Actual load current


Actual length of the line (m)
x
Rated load current
100m

(Load Constant) = 1, concentrated load


(a place such as an electrical room)

= 0.5, Distributed load


(a place such as a vertical section)

F P

F : Flanged End (panel connections)


P : Plug-in Unit

The required minimum distances between busducts


The required minimum distances between busducts are shown below.
Ampere(A)
joint

joint

P2

P1

P3

200

AL

joint

joint

100

100

200

3W and 3W

Standard Dimension (mm)


3W and 4W

4W and 4W

P1

110

135

130

P2

150

175

180

P3

190

215

230

200

*Outdoor installation requires a further discussion with our design team about proper distance.

34

E-series LS C&S-Busway System

CU

630
800
1,000
1,250
1,600
2,000
2,500
3,200
3,600
4,000
5,000
6,300
630
800
1,000
1,250
1,600
2,000
2,500
3,200
3,600
4,000
5,000
6,300
7,500

10-3 /100m, 60Hz

Voltage Drop(V/100m)

0.7

0.8

0.9

13.98
7.97
6.83
5.55
3.82
3.08
2.40
1.91
1.72
1.54
1.15
1.02
7.49
7.49
5.49
4.39
3.10
2.40
1.86
1.54
1.35
1.20
0.93
0.73
0.62

4.07
2.62
2.21
1.82
1.23
1.00
0.80
0.61
0.55
0.50
0.37
0.33
4.07
3.84
2.99
2.45
1.71
1.35
1.05
0.85
0.74
0.67
0.52
0.39
0.35

14.56
8.39
7.18
5.84
4.02
3.24
2.53
2.00
1.81
1.62
1.21
1.08
8.53
8.42
6.25
5.03
3.54
2.76
2.13
1.76
1.54
1.37
1.06
0.83
0.71

13.85
10.32
11.02
11.22
9.85
9.96
9.74
9.82
9.99
9.93
9.24
10.41
8.90
11.07
10.35
10.44
9.40
9.17
8.87
9.34
9.20
9.13
8.84
8.62
8.83

14.87
11.01
11.77
11.97
10.52
10.63
10.39
10.48
10.67
10.60
9.87
11.11
9.21
11.50
10.72
10.78
9.72
9.46
9.16
9.66
9.51
9.42
9.13
8.93
9.12

15.66
11.52
12.32
12.52
11.02
11.12
10.86
10.98
11.18
11.09
10.34
11.63
9.30
11.67
10.82
10.86
9.80
9.53
9.22
9.75
9.60
9.49
9.19
9.02
9.18

15.25
11.04
11.84
12.01
10.60
10.67
10.40
10.56
10.74
10.64
9.94
11.16
8.18
10.38
9.52
9.50
8.60
8.32
8.06
8.55
8.42
8.29
8.03
7.97
8.02

E-series LS C&S-Busway System

35

. Technical Data

06 / 07

Technical Data
Temperature Rise

LS C&S Busduct has been tested under actual short circuit conditions according to IEC 61439-1 and 6 [(previous standard) IEC 60439-1 and 2]
at KEMA and ASTA. The result and the graph are shown below.

The temperature rise limit is an important property which determines the performance of busducts. The temperature rise limit of the busduct is
designed that when a busduct is operated with a rated current , the temperature limit values of the housing are within 55K as specified
in IEC61439-1 and 6 [(previous standard) IEC 60439-1 and 2].

E-series

Short Circuit Strength

Phase to Phase Short Circuit Ratings


Ampere(A)
630
800
1,000
1,250
1,600
2,000
2,500
3,200
4,000
5,000
6,300
7,500

AL (kA)
1 sec
24
42
50
62
95
121
132
169
200
200
200
-

CU (kA)
3 sec
14
24
29
36
55
70
76
97
140
150
150
-

1 sec
36
36
51
65
95
129
150
191
200
200
200
200

3 sec
21
21
29
37
55
75
107
110
149
200
200
200
1

4
7

-Joint-

80

Temperature()

70
2

60

50
40

4
7 8
5 6

30

20
10
0

Classification

Sensor Location
Temperature Rise
Value

36

E-series LS C&S-Busway System

3
4
Time(hr)

Connection Conductor
58K

64K

60K

9
Ambient
Temperature

31K

31K

24

Housing
40K

32K

31K

E-series LS C&S-Busway System

37

V. Install Information

VI. Certification & Specification

Joint Connection

Certification & Specification

06 / 07

E-series

Both parts should be aligned at the top and the bottom and the left and
the right as well as horizontally and vertically. (This also applies to the joint
connection of the horizontal and vertical ducts.) Make sure that the joint kit
is not tilted. (We recommend a jig tool for the installation.)

Using a torque wrench, slowly tighten the exposed bolt head of a double
headed bolt. The head of the double headed bolt is designed to break off at
800~1000Kgf cm. Continue tightening the exposed head until it breaks off.

ASTA Certification (Ez-way)

ASTA Certification (Ex-way)

KEMA Certification (Ex-way)

KS Certification(E-series)

UL Certification (Ex-way)

CCC Certification(E-series)

Dust and Water Proof Certification


(E-series)

Fire Proof Certification (Ef-way)

Fire Sprinkler Certification (Ef-way)

Once the exposed head and the red tag attached to it have been cut off, a red line should be visible, which means they are properly connected. Be sure
to check the distance from the housing, and the gaps between the conductors at the kit after the installation.

Transparent cap
Before applying the connection cover, check the space between the
end block and the holes of the connection cover. The red line should be
visible through the transparent cap.

38

E-series LS C&S-Busway System

Perform the last inspection of the connection.

E-series LS C&S-Busway System

39

VI. Certification & Specification

06 / 07

Certification & Specification

Mini- way

LS C&S Busduct System Catalogue

02 of 08

Quake Proof
(SEISMIC ZONE/E-series)

TUV Eco Friendly Certification


(Ef-way)

ISO9001

Contents

ISO14001

40

E-series LS C&S-Busway System

OHSAS18001

I. Introduction
- Overview
- Application

42
43

II. General Data

44

III. Component
- Feeder
- Flanged End
- Fittings
- Hanger
- Plug-In Unit
- Etc

49
50
52
54
55
56

IV. Technical Data


- Impedance
- Voltage Drop
- Temperature Rise

57
57
58

V. Install Information
- Joint Connection

59

VI. Certification & Specification

60

E-series LSC&S-Busway System

Certification & Specification

41

I. Introduction

Overview
Mini-way
LSC&S Mini-way is an air insulation type bare conductor busduct, and designed for low currents at AC 1000V or less or between 160A and 800A.
Each conductor is compounded with a class B rating insulating material (thermal class 130 oC) and using a joint kit system
at the joint connections provides easy installation of feeders.
The Mini-way comes with an IP54 rating and is water proof which reduces malfunction during operation caused by water leakage.

06 / 07

Application
Data Center etc.
Supply power to computer equipments at each rack in the
server room.
Distribution boards or modular racks are not necessary.
Consist of two lines of general use and emergency use.

Safe and Efficient Distribution System


Mini-way

LS C&S Mini-way is suitable for lager modern structures such as apartment complexes,
factories, shopping malls, and data center server rooms because of easy load distribution,
extension and installation. Our highly experienced and well-trained professionals can design
highly efficient products which will harmonize with surroundings and other equipments.

Easy Installation

Apartments and Housing etc.

The light weight of LS C&S Mini-way enables easy transportation and installation, and employing the joint kit
system provides easy installation of the feeders.

Vertical Busducts can be installed at the EPS room.


Provides better space efficiency than cables
Multi-box can be applied

Excellent Performance
LS C&S Mini-way follows the IEC standard, and has
designed the cross-section, conductor support and housing shape according to the regulations of temperature.
Therefore it has efficient voltage drop and high short
circuit strength.

Shopping Centers / Air Port etc


Can be applied at the low capacity lines of department stores,
supermarkets and shopping malls
Provides better space efficiency than cables

42

Mini-way
Introduction
LS C&S-Busway
E-series
System
LSC&S-Busway System

E-series LSC&S-Busway
Mini-way
System
LS C&S-Busway
Introduction
System

43

. General Data

06 / 07

Elbow

Feeder
Joint Kit
Plug-in Hole
Plug-in Box

Joint Cover

Mini-way

Joint Kit

44

Weight

Eco Friendly

Conductors

Housing

The wonderfully light weight of the Mini-way was


possible due to aluminum housing, optimizing the
cross sectional areas and light weight components.

The LS C&S Busducts acquired RoHS certification, and


only uses components without hazardous substances
such as lead, cadmium, mercury, chrome, PBBs and
PBDEs.

The Mini-way uses either copper conductors with


conductivity over 99%, or aluminum conductors
with conductivity over 61%. The connection of the
conductors is tin-plated in order to reduce contact
resistance and to prevent to corrosion of the
connection. (A silver plated option is available.)

The Mini-way uses an effective heat radiating


aluminum housing profile which produces an
excellent mechanical strength and heat radiation.
The aluminum housing can be used as a protective
conductor (PE) due to its high level conductivity
and cross sectional areas.

Short Circuit Strength

Standard

Insulation Properties

Joint Kit

Thanks to the optimum design of the conductor


shapes, and predestinated space between support
insulations, the Mini-way can withstand mechanical
and thermal stress when a short circuit occurs.

IEC 61439-1 [(previous standard)IEC 60439-1]


Power Switchgear and Controlgear Assemblies
IEC 61439-6 [(previous standard)IEC 60439-2]
Busbar Trunking Systems
NSEN 60439 Busways
NEMA BU 1.1 Busways

The Mini-way uses the air insulation system. The


o
insulation of thermal rating Class B (130 C) provides
high insulation performance between conductors
and between conductors and housing. In order to
secure the stability of conductor support and high
short circuit performance, the design is following
CAE (Computer Aided Engineering) instructions.

Permissible Operating Temperature

Service Condition

The Mini-way uses joint kit to connect the bus


ducts. In order to ensure easy maintenance and
reliability, double-headed bolts and visible labels
(red tags) are used to check the application, and a
disc spring allows even connection of the contact
surface.(Connecting torque 800~1000kgf.cm)
The joint plate of the joint kit is tin plated in order to
prevent discoloration and corrosion.(A silver plated
option is available.)

The cross sectional areas of the conductor and


housing profile are designed to meet the standard
permissible operating temperature of IEC 61439-1
and 6. Therefore the temperature rise limit of the
housing is within 55K or less of the ambient temperature.

Ambient Temperature : -15 ~ 55


Relative Humidity : 95% or below
(When the service condition of the environment
does not meet the requirements listed above,
please contact our design team.)

Mini-way
General Data
LS C&S-Busway
E-series
System
LSC&S-Busway System

E-series LSC&S-Busway
Mini-way
System
LS C&S-Busway
General
System
Data

45

. General Data

06 / 07

General Concept

Grounding Capacity

LSC&S Mini-way is an air insulation type bare conductor busduct, and it supports each phase with Class B rating insulating
material (thermal class 130 oC). It is designed for AC 1000V or less or between 160A and 800A. It also comes with a joint kit
system and standard IP54 rating.

The aluminum housing of the Mini-way is designed to perform as a grounding conductor within the rated current. In
case 50~100% more grounding capacity is needed, an internal grounding conductor can be added without changing
the existing design.

Housing

Configration

Mini-way

[General Earth]
[3W+GE]

[4W+GE]

Housing

50% Earth

[3W+50%E]

[50% Earth]

[4W+50%E]
Housing

50% Earth

50% Earth

[3W+100%E]

*Special capacity such as 4W(200%N)+100%E at [Cu 160~400A] can be produced on request.

[4W+100%E]

[100% Earth]

Note
The aluminum housing itself acts as a grounding conductor and improves heat-radiation of conductors. The light weight of the Mini-way was possible thanks
to the innovated design to reduce the weight.

46

Mini-way LS C&S-Busway System

Mini-way LS C&S-Busway System

47

. General Data

. Component

IP Code (Degree of Protection)

Feeder

IP Code is an international protection degree code provided by IEC 60529(Degree of Protection Provided by Enclosure-IP Code)

Although the standard length of the Mini-way is 3 meters, it can be adjusted to the installation
environment on request.

NEMA STANDARD: IP54=NEMA 12, 12K, 13 IP55=NEMA 3, 3X, 3S, 3SX IP66=NEMA 4.4X IP67=NEMA 6

06 / 07

* As the standard differs, it is a similar substitution, nota 1:1 substitution.

The degree of protection against water of the Mini-way is a standard IP54; however, it can be adjusted up to IP65.
An additional sealing using high strength silicon is also available at the joint connections between the housing and the
connection cover on request.

IP
Mini-way

Liquid Ingress Protection

No Protection

0 No Protection

Protection against 50mm


diameter solid particles.
(back of a hand)

Protection against 12mm


solid particles. (fingers)

Protection against 2.4mm


solid particles.
(tools or thick wires)

Protection against 1mm


solid particles.
(tools or most wires)

Protection against dust.

Complete protection
against dust.

Protection against
falling drops of water.

Protection against falling


drops of water with an
enclosure tilted at a 15degree
angle from a vertical line

Protection against
strong jets of water
from all directions.

Protection against
spray sat a 60degree
angle from a vertical line

15cmmin.

Protection against the effects


of immersion between
15.0 centimeters and 1.0 meter.

Protection against
water splashed from
all directions.

1m

Protection against
longer periods of immersion
under pressure.

Protection against
low pressure jets of water
from all directions.

1m

Plating and Coating


Coating

Standard tin plating is applied at taps, plugs and connections


of conductors using an electroplating method to maintain the
electrical characteristics and to prevent corrosion. Silver plating is
available on request.

In order to improve the heat radiation and to prevent corrosion, as


well as to fit in with the surroundings, we apply polyester-epoxy
(hybrid) power coating after treating the surface. A wide range of
color is available to meet the needs of our clients.

Mini-way LS C&S-Busway System

[3W]

AL

Plating

Ampere(A)

48

CU

Solid Particle Protection

[4W]

Dimension (mm)
W
A

3W

Weight (kg/m)
4W
4W + 50%E

4W + 100%E

160

20

87

5.3

5.6

5.8

5.9

250

30

87

5.8

6.3

6.5

6.7

107

6.9

7.7

8.1

8.4

400

6.35

50

165

630

70

127

7.9

9.1

9.6

10.1

800

95

152

9.2

10.9

11.5

12.2

160

20

87

5.8

6.3

6.8

7.2

250

30

87

6.8

7.6

8.3

9.1

107

8.1

9.4

10.6

11.9

400

6.35

50

165

630

50

107

12.8

15.6

16.9

18.1

800

70

127

16.2

20.1

21.9

23.7

Mini-way LS C&S-Busway System

49

. Component

06 / 07

Flanged End
Drilling Pattern for Flanged

The flanged end is connected to either a transformer or a panel.


Dimension details are shown below.

50

50
150
200

12

[3W+GE]

[4W+GE]

20

[side]

50
150
200
A

AL

40

50
A
[3W+50%E]

12

[4W+50%E]

20

70

150
200

Ampere(A)

70

Mini-way

40

50
150
200

Dimension(mm)
A

Dimension(mm)

Ampere(A)

160

200

70

160

200

70

250

200

70

250

200

70

400

220

400

220

630

240

100

630

220

80

800

265

125

800

240

100

340

80

370

CU

340

80

370

[side]

Flanged End Box


Dimension(mm)
Ampere(A)

AL

CU

160

20

250

30

400

6.35

70

800

95

160

20

250

30
6.35

3W

4W

500
L
AL

50

630

400

Ampere(A)

50

630

50

800

70

B A
100

100

D
C

CU

Dimension(mm)
W

160

20

190

130

250

30

200

140

400

50

220

160

630

6.35

70

240

180

800

95

265

205

160

20

190

130

250

30

200

140

50

220

160

630

50

220

160

800

70

240

180

400

6.35

510

450

270

510

450

270

*t : thickness of a conductor

50

Mini-way
Component
LS C&S-Busway
E-series
System
LSC&S-Busway System

E-series LSC&S-Busway
Mini-way
System
LS C&S-Busway
Component
System

51

. Component

06 / 07

Fittings
Tee

Mini - way Busduct has a wide range of fittings to satisfy any layout of buildings. Elbow angles other than 90 oC are also
available. Fitting designs are shown in the following figures, and they consist of the source-side and the load-side.
Offset or combination elbows can be used where standard elbows are not feasible.
(Dimensions for each fitting are shown in the following figures. Contact our design team for a minimum dimension.)

[Vertical]

[Horizontal]

[Vertical]

[Horizontal]
Y

X Y

X
X
Y

Ampere(A)
160 ~ 800
X

X
Dimension(mm)
X

500

500

X
500

Y
Y

500
Y

[Vertical]

Y
X

Ampere(A)
160 ~ 800

Mini-way LS C&S-Busway System

500

500

Z
Z
Dimension(mm)
H
Y
Y

H
Z

160 ~ 800
X
X
X

Z
X

500

Ampere(A)
H
X

X Z

160 ~ 800

500

Combination

Y
Y

160
X
250

Dimension(mm)
Y

500

500

Z
500

Dimension(mm)
Y
H_AL
H_CU
Y
134
134
144

400

X144
164

630

184

164

800

209

184

164

X
X

X
Z

500

Ampere(A)

160 ~ 800

[Horizontal]

X
X

Y
Y

Ampere(A)

Z
Dimension(mm)

Y
Y
X
Z
500

X
Y

X
X
Ampere(A)

Y
Y

Offset

160Y ~ 800

X
Dimension(mm)

Ampere(A)

X
X

Mini-way

52

Elbow

X
X

Z
Z

Dimension(mm)
X

500

500

500

Ampere(A)
160 ~ 800

Dimension(mm)
X

500

500

500

Ampere(A)
160 ~ 800

Dimension(mm)
X

500

500

500

Mini-way LS C&S-Busway System

53

. Component

06 / 07

Hanger

Plug-in Unit

Busducts installed on the ceilings, floors, walls and beams are usually supported by stud bolts, system channels, angles and
channels. Various types of hangers are available depending on the installation condition or environment.
(Please contact our design team for further information about hanger types and installation.)

The position of the plug-in distribution location will be decided according to the installation environment and on
request. The standard length of the feeders is 3 meters, and a maximum of 8 plug-in holes can be made on a 3 meter
feeder. In order to secure the smooth access between the plug-in brushes and feeders, a guide pin has been attached

Horizontal Hangers
[Flatwise]

[Edgewise]

Hanger Rod 12

Hanger Rod 12
Guide Pin

Guide Pin Hole

Mini-way

Plug-in Box
Hanger Clamp

Hanger Clamp

Attachments such as CT, TD and PT can be installed in a plug-in box to control and to supervise current, voltage and wattage remotely.

Door Types of the Plug-in Box

Vertical Hangers

Various design of doors for the plug-in box is available to satisfy the demands of our clients.
The available types are shown below.

[Rigid Hanger]

Base Channel

- Front Type -

- Side Type -

External handle

Push Button

External lever interlock

Bolt Fastening

Key Lock

Outlet

[Spring Hanger]

Base Channel

- Front Type -

54

Mini-way LS C&S-Busway System

- Side Type -

Mini-way LS C&S-Busway System

55

. Component

. Technical Data

Etc.

Technical Data

Wall Flange

Floor Opening

W+160

Wall Open Size


Cut Out

Wall Flange

Fire Foam
(out of scope)

30

W+60

W+60
W

Impedance and Voltage Drop


Floor Opening Size
Cut Out

30
H+160

The formula to measure the voltage drop of a Busduct is shown below. The impedance and voltage drop values for aluminum
and copper conductors are shown in the table below.
The values listed are measured between the upper and middle lines at 60Hz. For a 50Hz installation, multiply the reactance (X) by 0.83.

Vd = I x 3(R cos + X sin)

30

W+10
H+10
H+60

06 / 07

H H+60

Vd = voltage drop[V] I = rated road amperes[A] R = resistance[] X = reactance[] / cos = power factor / sim = reactive factor
Actual voltage Drop = x Vd x

30

Glass Wool
(out of scope)

Actual load current


Actual length of the line (m)
x
Rated load current
100m

(Load Constant) = 1, concentrated load

W : The width of the product (165mm)


H : The height of the product (It is decided by a rated current.)

W : The width of the product (165mm)


H : The height of the product
(It is decided by a rated current.)

(a place such as a vertical section)

160
250
400
630
800
160
250
400
630
800

AL

The Required Minimum Distances from a Wall for Heat Dissipation


, ceiling
wall ,wall
ceiling
wall
,
ceiling
wall , ceiling

wall wall
wall
wall

200
200
200200

ceiling
ceiling
ceiling
ceiling

wallwall
100
wall
wall 100

100
100

100 100
100
100

Wall,ceiling

Mini-way LS C&S-Busway System

10-3 /100m, 60Hz

Voltage Drop(V/100m)

0.7

0.8

0.9

1.0

66.4
32
15.3
6.7
5.0
82.2
35.1
17.6
5.9
4.4

18.1
15.1
13.8
8.0
6.5
20.9
17.6
13.7
9.8
8.1

68.8
35.4
20.6
10.5
8.2
84.8
36.3
22.3
11.4
9.2

8.72
9.15
10.74
11.38
11.28
9.17
9.64
11.24
12.14
12.25

9.15
9.42
10.76
11.11
10.95
9.56
9.80
11.34
11.56
11.57

9.40
9.44
10.42
10.41
10.16
9.73
9.68
11.10
10.44
10.33

8.82
8.13
8.19
7.32
6.92
8.75
8.04
8.96
6.42
6.05

Short Circuit Strength


LS C&S Busduct has been tested under actual short circuit conditions according to IEC 61439-1 and 6 [(previous standard) IEC 60439-1 and 2] at KEMA.
The result and the graph are shown below. Phase to Phase Short Circuit Ratings

wall wall
wall
wall

100 100
wall wall100
100
wall
wall

Ampere (A)
160
250
400
630
800

56

F P

F : Flanged End (panel connections)


P : Plug-in Unit

100
100
100100

Joint
Point
Joint
Point
JointPoint
Point
Joint

CU

100
100
100100

250mm
250mm
250mm
250mm

Beam
Beam
Beam
Beam

= 0.5, Distributed load

Ampere(A)

wall , ceiling
wall , ceiling
wall
ceiling
wall ,, ceiling

Mini-way

(a place such as an electrical room)


A wall flange is used to seal the gaps produced during installation of Busducts at the walls,
ceilings and floors.

AL(kA)
1 sec.
10
10
25
30
40

CU(kA)
3 sec.
6
6
15
17
23

1 sec.
10
10
25
30
40

3 sec.
6
6
15
17
23

E-series LSC&S-Busway
Mini-way
SystemLS C&S-Busway
Technical
System
Data

57

. Technical Data

. Install Information

Technical Data

Joint Connection

06 / 07

Temperature Rise
The temperature rise limit is an important property which determines the performance of Busducts. The temperature rise
limit of the Busduct is designed so that when a busduct is operated with a rated current, the temperature limit values of the
housing are within 55K as specified in IEC61439-1 and 6 [(previous standard) IEC 60439-1 and 2].

Both parts should be aligned at the top and the bottom and the left and
the right as well as horizontally and vertically. (This also applies to the joint
connection of the horizontal and vertical ducts.) Make sure that the joint
kit is not tilted. (We recommend a jig tool for the installation.)

Using a torque wrench, slowly tighten the exposed bolt head of a double
headed bolt. The head of the double headed bolt is designed to break
off at 800~1000Kgfcm. Continue tightening the exposed head until it
breaks off.

Once the exposed head and the red tag attached to it have been cut off,
they are properly connected.

Be sure to check the distance from the housing, and the gaps between the
conductors at the kit after the installation.

Before applying the connection cover, check the space between the end
block and the holes of the connection cover.

Perform the last inspection of the connection. (Follow the instruction of


the installation manual for additional sealing according to the IP Code)

4
7

-Joint-

80

2 3
1

70
Temperature()

Mini-way

60

50

7 8

40

30

6
9

20
10
0

Classification

Censer Location
Temperature Rise
Value

58

3
4
Time(hr)

Connection Conductor
75K

79K

Mini-way
TechnicalLS
Data
C&S-Busway
E-series
System
LSC&S-Busway System

80K

Ambient
Temperature

Housing
61K

39K

32K

52K

53K

23

E-series LSC&S-Busway System


Mini-way LS C&S-Busway
Install Information
System

59

VI. Certification & Specification

06 / 07

Certification & Specification

LT- way

LS C&S Busduct System Catalogue

03 of 08

Fire proof Certification

Dust and Water proof


Certification

TUV Eco Friendly Certification

Contents

KEMA Certification

ISO9001

60

Mini-way
Certification
LS C&S-Busway
& Specification
System

E-series LSC&S-Busway System

KEMA Certification

ISO14001

KEMA Certification

I. Introduction
- Overview
- Application

62
63

II. General Data

64

III. Component
- Feeder
- Feed in Unit
- Flexible Fitting
- End Cover
- Hanger
- Plug in Unit

67
70
71
72
72
73

IV. Technical Data


- Impedance
- Voltage Drop
- Temperature Rise

74
74
75

V. Install Information
- Joint Connection
- Plug-in Unit Installation

76
76

VI. Certification & Specification

77

OHSAS18001

E-series LSC&S-Busway System

Certification & Specification

61

I. Introduction

Overview
About LT-way
LS C&S LT-way is designed for small capacity loads of 25 to 63A such as lamp circuits. It is also designed to blend in well with the existing facilities, while
providing the optimum power supply system. The LT-way comes with the optimized cross sectional areas as well as stable design of conductors and
housing, which provide efficient heat-radiating property specified in IEC heat regulations. The LT-way also comes with a high degree of protection with
standard IP54. The design can be applied in a special environment such as greenhouses and clean-rooms. Its adaptability to frequent alterations of a
layout makes it a perfect product.

06 / 07

Application
Supermarkets / Shopping Mall etc.
Can be used as lighting system in the store.

Safe and Efficient Distribution System


LS C&S LT-way is designed for small lines or lamp circuits at buildings, factories and shopping malls.
The plug and the outlet attached to the LT-way provide easy management of load distribution.

Eco-Friendly
The LS C&S LT-way is an environmentally friendly product following the
RoHS regulation, and only uses components without hazardous substances.

Easy Installation

Factory etc.
Can be used as lighting system for production lines.
Excellent flexibility and adaptability to layout changes.

LT-way

The light weight of LS C&S LT-way enables easy transportation


and installation, and employing the joint brush system makes
it easy to take apart and assemble. The plug-in load distribution
provides easier maintenance and installation compare to cables.

Basement Parking etc.


Can be used as lighting system for basement parking space of
large buildings, apartments and commercial complexes.

62

LT-way
Introduction
LS C&S-Busway
E-series
SystemLSC&S-Busway System

E-series LSC&S-Busway
LT-way
System
LS C&S-Busway
Introduction
System

63

. General Data

06 / 07

Plug-in Unit
Plug-in Hole

Feeder
Flexible Fitting

Feed-in Unit
Plug-in Unit

Eco Friendly

Conductors

Housing

The compact and light weight design of extruded


aluminum housing is suitable for low capacity power
lines between 25 to 63A.

The LS C&S Busducts acquired RoHS certification, and


only uses components without hazardous substances
such as lead, cadmium, mercury, chrome, PBBs and
PBDEs.

The conductor uses over 99 percent pure copper flat


wire consisting of 2 or 4 fibers. Elongated marks have
been etched in order to prevent slips when pressed.
The LT-way comes with high molecule insulation of
a fire proof grade A rating. The intervals between
insulations have been designed for the optimum
functionality as specified in CAE (Computer Aided
Engineering).

The high strength aluminum housing can be used


as a protective conductor (PE) due to its high level
conductivity and mechanical strength. Variety of
coating options for the housing is available on request.

Easy Load Distribution

Standard

Insulation

Joint Brush

Each feeder (3 meters) can have a maximum 10 load


distributions installed, and provide them easily.

IEC 61439-1 [(previous standard)IEC 60439-1]


Power Switchgear and Controlgear Assemblies
IEC 61439-6 [(previous standard)IEC 60439-2]
Busbar Trunking Systems

Other than the connections and the PH, the conductor


has been insulated which prevent accidents caused by
impacts. The insulation uses PVC which has the fire proof
grade A rating (105) according to IEC regulations.

The Joint brush can be safely and easily connected


with a live wire. Optional double cover is available.
The double enhances the strength against impacts.

Permissible Operating Temperature

Service Condition

The cross sectional areas of the conductor and housing


profile are designed to meet the standard permissible
operating temperature of IEC 61439-1 and 6. Therefore
the temperature rise limit of the housing is within 55K
or less of the ambient temperature.

Ambient Temperature : -15 ~55


Relative Humidity : 95% or below
(When the service condition of the environment does
not meet the requirements listed above, please contact
our design team.)

LT-way
GeneralLSData
C&S-BuswayE-series
SystemLSC&S-Busway System

E-series LSC&S-Busway
LT-way
System
LS C&S-Busway
General
System
Data

LT-way

64

Weight

65

. General Data

. Component

Basic Structure

Feeder

LT-way comes with flat-wire, and suitable for small loads or lamp loads of 690V 25 to 63A. Each phase has been wrapped
with PVC, an electric insulation with an A rating (fire proof grade 105 oC) or higher, and the same rating insulation supports
them.

The standard length of feeders is either 3 meters or 1.5 meters,


and 5 plug-in holes can be applied on each side of a
3 meter feeder (maximum 10 holes).
For a 1.5 meter feeder, 3 plug-in holes can be applied
on each side (maximum 6 holes).

06 / 07

Configration

Phase : (PH + N + PE)


Wire : 2
Tier : 1

Phase : (3PH + N + PE)



(PH + N + PE)
Wire : 6
Tier : 2

1500
250

500

500

250

1500
375

750

375

W
Phase : (3PH + N + PE) x 2
Wire : 8
Tier : 2

3000
300

600

600

600

600

LT-way

Phase : (3PH + N + PE)


Wire : 4
Tier : 1

300

3000
500

Phase : (PH + N + PE) x 2


Wire : 4
Tier : 2

Phase : (3PH + N + PE)


Wire : 4
Tier : 2

1000

1000

500

3000
750

1500

750

*It only applies to the special capacity (63A).

Dimension(mm)

Ampere(A)

25
CU

40
63

66

LT-way LS C&S-Busway System

1.8

30

50

2.8

LT-way LS C&S-Busway System

67

. Component

06 / 07

Feeder
A single housing can handle two lines (R, S, T, N X 2), and the 3-phase 4-wire system supplies larger capacity than a single
phase which decrease the line imbalance.

Configuratian

STD. Feeder
(Ph + N + PE)

STD.Feeder
(3Ph+N+PE)

68

LT-way LS C&S-Busway System

Wire
W

Tier
Tier

Length
mm

Plug-in hole
EA

25

3000

25

3000

Weight
g/m

2355

Ampere
A

Wire
W

Tier
Tier

Length
mm

Plug-in hole
EA

LSLT F252130

25

3000

LSLT F252132

25

3000

25

3000

25

3000

25

1500

25

1500

40

3000

LSLT F402130

40

3000

LSLT F402132

40

3000

40

3000

40

1500

40

1500

Cat No.
No.

25

3000

25

3000

LSLT F252135

25

1500

LSLT F252112

1500

40

3000

1260

Configuratian

LSLT F252133

LSLT F252113

STD. Feeder
(Ph + N + PE) x 2

40

3000

40

3000

40

3000

LSLT F402135

40

1500

LSLT F402112

25

3000

40

1500

LSLT F402113

25

3000

25

3000

LSLT F254130

25

3000

LSLT F254132

25

3000

25

1500

25

1500

40

3000

40

3000

LSLT F254113

40

3000

LSLT F404130

40

3000

LSLT F404132

40

1500

40

1500

25

3000

25

3000

25

3000

2520

1340

LSLT F402133

25

3000

25

3000

25

3000

LSLT F254135

25

1500

LSLT F254112

25

1500

40

3000

40

3000

40

3000

2615

1390

2970

LSLT F254133
STD. Feeder
(3Ph + N + PE)(Ph + N + PE)

LSLT F404133

40

3000

LSLT F404134

40

3000

LSLT F404135

40

1500

LSLT F404112

25

3000

40

1500

LSLT F404113

25

1500

63

3000

25

1500

40

3000

40

3000

40

3000

1565

LSLTF634130

63

3000

63

3000

63

1500

LSLTF634135

40

3000

63

1500

LSLTF634112

40

1500

63

3000

LSLTF634113

40

1500

3860

2010

LSLTF634132

STD. Feeder
(3Ph + N + PE) x 2

LSLTF634133

Weight
g/m

Cat No.
No.
LSLT F256230

2615

LSLT F256232
LSLT F256233
LSLT F256235

1390

LSLT F256212
LSLT F256213
LSLT F406230

2970

LSLT F406232
LSLT F406233
LSLT F406235

1565

LSLT F406212
LSLT F406213
LSLT F256230

2890

LSLT F256232
LSLT F256233
LSLT F256235

1525

LSLT F256212
LSLT F256213

LT-way

STD. Feeder
(3Ph + N + PE)

Ampere
A

LSLT F406230
3415

LSLT F406232
LSLT F406233
LSLT F406235

1790

LSLT F406212
LSLT F406213
LSLT F258230

3175

LSLT F258232
LSLT F258233
LSLT F258235

1670

LSLT F258212
LSLT F258213
LSLT F408230

3860

LSLT F408232
LSLT F408233
LSLT F408235

2010

LSLT F408212
LSLT F408213

LT-way LS C&S-Busway System

69

. Component

06 / 07

Flexible Fitting

The feed in unit connects cables and the LT-way. It can connect a maximum 10mm2 and is
used at the opening and ending points of source and load system.

The flexible fitting rotates 180 and is used to adjust the height or bypass a route.
The fixing method is the same as the feeder and the standard length is 0.5m and 1m.

69

53

Feed in Unit

33
500
347

90

[Load]

105

69

1000
605
271

90

[Source]

Configuration

STD. Feeder
(Ph + N +PE)

Wire

Tier

Source/Load

Weight

Tier

No.

Source/Load
Source

g/m

25

500

LSLT U2521S

25

Load

600

LSLT U2521L

STD. Feeder
(3Ph + N +PE)
(Ph + N + PE)

STD. Feeder
(3Ph + N +PE) x 2

70

LT-way
Component
LS C&S-Busway
E-series
System
LSC&S-Busway System

Configuration

STD. Feeder
(Ph + N +PE)

Ampere

Wire

Tier

Length

Weight

Cat No.

Tier

mm

g/m

No.

25

500

585

LSLT X25210

25

1000

1010

LSLT X25211

40

Source

515

LSLT U4021S

40

500

610

LSLT X40210

40

Load

515

LSLT U4021L

40

1000

1060

LSLT X40211

25

Source

515

LSLT U2541S

25

500

630

LSLT X25410

25

Load

515

LSLT U2541L

25

1000

1100

LSLT X25411

40

500

615

LSLT X40410

40

1000

1195

LSLT X40411

40

Source

550

LSLT U4041S

40

Load

550

LSLT U4041L

63

Source

615

LSLTU6341S

63

500

815

LSLTX63410

63

Load

615

LSLTU6341L

63

1000

1465

LSLTU63411

Source

515

LSLT U2542S

25

500

630

LSLT X25420

25

1000

1110

LSLT X25421

40

500

615

LSLT X40420

40

1000

1195

LSLT X40421

25

500

675

LSLT X25620

25

1000

1185

LSLT X25621

40

500

745

LSLT X40620

25
STD. Feeder
(Ph + N +PE) x 2

Cat No.

25

Load

515

LSLT U2542L

40

Source

550

LSLT U4042S

40

Load

550

LSLT U4042L

25

Source

530

LSLT U2562S

STD. Feeder
(3Ph + N +PE)

STD. Feeder
(Ph + N +PE) x 2

STD. Feeder
(3Ph + N +PE)
(Ph + N + PE)

25

Load

530

LSLT U2562L

40

Source

580

LSLT U4062S

40

Load

580

LSLT U4062L

40

1000

1330

LSLT X40621

25

Source

545

LSLT U2582S

25

500

720

LSLT X25820

25

1000

1275

LSLT X25821

40

500

815

LSLT X40820

40

1000

1465

LSLT X40821

25

Load

545

LSLT U2582L

40

Source

615

LSLT U4082S

40

Load

615

LSLT U4082L

STD. Feeder
(3Ph + N +PE) x 2

E-series LSC&S-Busway
LT-way
System
LS C&S-Busway
Component
System

LT-way

STD. Feeder
(3Ph + N +PE)

Ampere

71

. Component

06 / 07

End Cover

Plug-in Unit

The end cover is applied at the end of a rail,


and is the same for all capacities.

The load distribution system can be either installed or removed with a live line. The unit is a double-sided
clamp to connect a conductor, and incombustible materials have been used for the insulation and plastic
Phase Joint Type

53

It is usually used for single phase products,


and the design maximizes the convenience.

24
Capacity

Source/Load

Cat No.

Source / Load

No.

25

Source

LSLT ES

25

Load

LSLT EL

40

Source

LSLT ES

40

Load

LSLT EL

63

Source

LSLT ES

63

Load

LSLT EL

53

33

93

33

Hanger
General Type

Direct Type

Maximum
Load
kg

General Type

It is installed at the
hanging bolt.

60

Direct Type

It is installed at the
fixing band.

60

The hangers are used to install the busducts at buildings.


They can be either installed directly to the ceiling, or at the hanger rods.
The standard installation interval between hangers is 1.5 meters.
Caution) When the hangers are used to fix lamps, avoid the positions of
the joint connection.

72

LT-way LS C&S-Busway System

Phase
Selection
Type

10/16A

Fuse
Type

10/16A

Cat No. (No)


LSLT P10F1
LSLT P10F2
LSLT P10F3
LSLT P10S1
LSLT P10S2
LSLT P10S3
LSLT P10S12
LSLT P10S13
LSLT P10S23
LSLT P10S4
LSLT P10FU1
LSLT P10FU2
LSLT P10FU3
LSLT P10FU12
LSLT P10FU13
LSLT P10FU23
LSLT P10FU4

Fuse Type

The adaptability of this type provides options to select a suitable phase


depending on the condition of the installation site. The internal process
of the type can be checked through the transparent cover.

It is the same type as the phase selection type; however, the fuse type
comes with a fuse for each phase to protect faulty current and overcurrent
caused by load distribution.

Product

Capacity(A)

1 outlet

10/16

3 outlet

10/16

It is designed for low capacity products (63A or less). Easy to use and a
1-outlet or 3-outlet plug-in is available.

Note
Please contact out design team if a special type of hangers (Tee or Reducer) are required due to the installation environment.

10/16A

Phase
L1+N
L2+N
L3+N
L1+N
L2+N
L3+N
L1+L2
L1+L3
L2+L3
L1+L2+L3+N
L1+N
L2+N
L3+N
L1+L2
L1+L3
L2+L3
L1+L2+L3+N

1 outlet

3 outlet

Phase
L1+N
L2+N
L3+N
L1+L2
L1+L3
L2+L3
L1+L2+L3+N
L1+N
L2+N
L3+N
L1+L2
L1+L3
L2+L3
L1+L2+L3+N

LT-way

Install Method

Capacity(A)

Phase
Joint
Type

Phase Selection Type

Plug-in Type

Product

Product

Cat No.(No)
LSLT P10S1
LSLT P10S2
LSLT P10S3
LSLT P10S12
LSLT P10S13
LSLT P10S23
LSLT P10S4
LSLT P10FU1
LSLT P10FU2
LSLT P10FU3
LSLT P10FU12
LSLT P10FU13
LSLT P10FU23
LSLT P10FU4

LT-way LS C&S-Busway System

73

. Technical Data

06 / 07

Technical Data
Impedance and Voltage Drop

Temperature rise

The formula to measure the voltage drop of a Busduct is shown below. The impedance and voltage drop values for aluminum and
copper conductors are shown in the table below.
The values listed are measured between the upper and middle lines at 60Hz. For a 50Hz installation, multiply the reactance (X) by 0.83.

The temperature rise limit is an important property which determines the performance of busducts. The temperature rise limit of the Busduct is
designed so that when a Busduct is operated with a rated current , the temperature limit values of the housing are within 55K as specified
in IEC61439-1 and 6 [(previous standard) IEC 60439-1 and 2].

Vd = I x 3(R cos + X sin)


Vd = voltage drop[V] I = rated road amperes[A] R = resistance[] X = reactance[] / cos = power factor / sim = reactive factor
Actual voltage Drop = x Vd x

Actual load current


Actual length of the line (m)
x
Rated load current
100m

(Load Constant) = 1, concentrated load


(a place such as an electrical room)

= 0.5, Distributed load


(a place such as a vertical section)

F P

F : Flanged End (panel connections)


P : Plug-in Unit

4
7

Ampere(A)

Voltage Drop(V/100m)

-Joint-

0.7

0.8

0.9

25

8.1

0.2

8.1

0.25

0.29

0.32

0.35

40

3.35

0.167

3.4

0.17

0.19

0.21

0.23

63

1.67

0.141

1.7

0.14

0.16

0.17

0.18

80
70
Temperature()

Short Circuit Strength

60
50

2
3 1

40

30
20

LT-way has been tested under actual short circuit conditions according to IEC 61439-1 and 6 [(previous standard)
IEC 60439-1 and 2].
Ampere(A)

7 5
8 6
9

10

Copper(kA)
1 sec.

3 sec.

25

0.6

0.34

40

1.4

0.8

63

1.4

0.8

Classification

Censer Location
Temperature Rise
Value

74

LT-way
Technical
LS C&S-Busway
Data
E-series
System LSC&S-Busway System

LT-way

CU

10-3 /100m, 60Hz

3
4
Time(hr)

Connection Conductor
46K

49K

46K

Ambient
Temperature

Housing
40K

15K

14K

15K

14K

12

E-series LSC&S-BuswayLT-way
SystemLS C&S-Busway
Technical
System
Data

75

. Install Information

VI. Certification & Specification

Joint Connection

Certification & Specification

1) Check the condition of the joint, and loosen the cross heads
of the protection cover.

06 / 07

2) Insert the end into the other as shown in the image below,
and tighten the cross heads.

Caution) Dont loosen the hexagon bolts for they fix the
products in place.

(O)

(X)

(X)

(O)

Temperature Rise Test KERI


Certification

Temperature Rise Test KERI


Certification

Heat Resistant Performance


Certification

TUV Environmentally Friendly


Certification

ISO 14001

ISO 9001

! Caution
Make sure to clean the parts of the joint before installation. Proceed with caution since the joint can be damaged by impacts.
Be sure to keep them straight and steady to connect.

LT-way

Plug-in Unit Installation


Open the plug cover as shown below, and insert an appropriate plug-in unit or an outlet plug.

! Caution
Make sure the plug-in holes are clean before inserting the plug-in unit. Be sure to check the phase of unit and the plug.

76

LT-way
Install Information
LS C&S-Busway System
E-series LSC&S-Busway System

OHSAS 18001

E-series LSC&S-Busway System

LT-way
Certification
LS C&S-Busway
& Specification
System

77

06 / 07

Memo

BTMS(Temperature
Monitoring System)
(DTS, MPTS, IR-Ts)

08 of 08

Contents
I. Introduction
- Overview
- Application

80
81

II. Component

78

Certification
LT-way LS C&S-Busway
& Specification
System

E-series LSC&S-Busway System

- DTS

82

- MPTS

85

- IR-Ts

88

E-series LSC&S-Busway System

Certification & Specification

79

I. Introduction

06 / 07

Application

Overview
About BTMS
The temperature sensors of the Busduct Temperature Monitoring System (BTMS) measure busduct temperatures in real time to check the abnormality
of the lines to prevent accidents. Therefore, the BTMS is the optimum monitoring system for busducts.

S
DTS (Optical Fiber Cable Sensor)
MPTS (Digital Temperature Sensor)

Why BTMS?

The standard evaluation method to check the stability of the busduct and other power distribution system is the evaluation of a permissible temperature and temperature change of the insulation materials. The permissible temperature is also used by international standards such as IEC to evaluate the
stability. Therefore, any abnormality of a product can be detected just by checking the temperature change.

BTMS Benefit

1) Easy Maintenance: Real time monitoring of the entire system including inaccessible areas
2) Unmanned Monitoring System: Minimize the size of the supervision staff for periodic inspection

BTMS Measuring Principles


01 Fixed Temperature Measurement
(Comparison to the Standard Temperature)

Temperature()

IR-Ts (Infrared Temperature Sensor)

Distance(m)

Feature
Temperature()

- Repeaterless measurement between


1 to 12km.

- Measure temperatures at specific points only


(up to 80 points can be measured on a single
line).

- Measure a specific point only


(single point for each line).

Economical
Efficiency

-Suitable for long-distance sensor installation.


-The cost of a measuring device is higher for
the optical fiber.

-Economical due to temperature sensors and


communication modules.
-Harness module

-Suitable for local or small-scale installation.


-The cost can be high, depending on the
sensor type.

Installation
and
Maintenance

- Maintenance for optical fiber cable routing is


required since optical attenuation can occur
when cable bends.
- Easy maintenance

- Connectors between the modules ensure


easy installation
- High-voltage line effect

- Additional repeaters and lines are


necessary when transmitting power
for multiple lines.
- Due to the single point for each line
system, high maintenance is required.

Application

- Power Plant, Oil & Gas


- Display, Semi-conductor Ex) Busduct routes

- Small-sized equipment facilities


(electrical rooms)
- Ex. joint connection of busducts

- Ex. Distribution panel+


busduct joint connections

Maximum
Measurement
Section

Distance(m)

Temperature()
Alarm

Distance(m)

E-series LSC&S-Busway
BTMS
System
LS C&S-Busway
Introduction
System

BTMS

BTMS
Introduction
LS C&S-BuswayE-series
SystemLSC&S-Busway System

- Measure temperature at a specific point


- Direct or proximity measurement
- High-speed response

Alarm

For busducts with two or more stacks, an alarm will be set off if the temperature
differences of the stacks are higher than the set value.
Ex. A-stsck : 55, B-stack : 65

80

IR-Ts (Infrared Temperature Sensor)

Temperature()

Detect abnormalities based on temperature variations between one


measuring point and the other.
Ex. An alarm will be set off when the temperature of a measuring point A is
higher than the temperatures of four locations before and after A.

04 Proportional Measurement
(Comparison to Temperature Differences)

MPTS (Digital Temperature Sensor)


- Measure temperatures at multiple points
- Proximity measurement of the points
- Identify the variation using data log

T
Distance(m)

DTS (Optical Fiber Cable Sensor)


- Sequential temperatures
- Measure temperature by conducting
properties
- High-speed response

Monitoring

Alarm

Detect abnormality if the temperature increases over the set value of the
temperature during a certain period of time.
Ex. When the system is set for one minute, and the temperature variation is set
for 7C, an alarm will be set off if the temperature increases over the set value
within the scheduled time period.

03 Proportional Differential Temperature Measurement


(Comparison to Temperature Variations)

Alarm

Detect abnormalities if the temperature increases over the set value of the
standard temperature.
Ex. Set at 60 C : A pre-alarm will be set off at 50 C
An alarm will be set off at 60 C

02 Differential Temperature Measurement


(Comparison to Time and Temperature)

81

. Component

06 / 07

DTS

(Distributed Temperature System)


DTS Overview

Features of DTS
DTS

1) Optical fibers are used as the temperature sensor for the DTS.
Compact and light weight
The DTS does not get affected by EMC and EMI.
Economical
2) Measure and monitor temperature of long distance section.
3) A self-diagnosis system as well as an auto adjusting system for optical attenuation of optical fibers.
4) The DTS collects and manages the temperature data. The computer based system ensures easy management of HMI and data.

By channels (1,2,4,6ch) and distances (2,4,8,10,12km)


Temperature sensing distance(1m) , Accuracy

Industrial Computer
Stability of industrial PC
Fast and stable monitoring and data management
High capacity HDD with 1 terabyte

Principles of Distance Measurement


The distance of the point where the temperature has been measured is calculated using the process speed of the laser
pulse within the optical fibers.

UPS (Optional)

x = c x t/2

Protect power supply of computer equipment


and peripheral devices

Provide stable power supply in case of power failure

Fiber is the distributed sensor

DTS
Laser Pulse

Laser

GUI

Backscattered Light

Detector

Objective and convenient screen layout


Self data backup and organization system
(data analysis-detect, manage and predict problems)

Principles of Temperature Measurement

Relay and Warning light

Various back scattering laser lights return when the laser pulse has been discharged. One of the back scattering laser lights is
a Raman scattering light, and its wavelength change and scattering strength are used to measure the temperature.

Interlocked with the computer and can manage up to 8 signals


Semi-permanent LED warning lights

Ias
Is

(-

hav
)
kT

DTS
Monitoring PC

Directional
Coupler

82

BTMS
General
LSData
C&S-BuswayE-series
System LSC&S-Busway System

Optical Fiber Sensor

Luminous
Source

BTMS

las : The illumination level


of the anti-stoke light
la : The illumination level of
the stoke light
h : Planck constant
k : Boltzmann constant
c : The speed of light
v : Frequency of incident
light
T : Temperature

Optical Fiber

Raman Scattering Laser Light


Rayleigh Band

Signal Processing

Anti-Stokes Raman
Band

Stokes Raman
Band

General Function
Monitoring temperature profile: Temperature vs. Distance graph
Monitoring by zones, lines and loads: Up to 500 pre-designated points and statistical information
Auto detection and warning system (when bidirectional measurement was applied) of optical attenuation and fiber cut
Warning system: Data prints based on real time temperature measurement
Warning signals can be interlocked with other systems
(Ex. Interlocking with fire signal)
E-series LSC&S-Busway
BTMS
System
LS C&S-Busway
General
System
Data

83

. Component

06 / 07

MPTS
(Multi-Point Temperature System)
MPTS Preview

DTS Application

The MPTS measures temperature of a specific point by installing a digital temperature sensor at a specific point including the joint
connection of a busduct.
Each sensor is linked to a communication system to transmit the measured temperature in real time.
Up to 80 points can be linked to a single communication line.

Principles of the Digital Temperature Sensor


Principles
[SMS Transmission Screen]

The temperature is set by the size of the vibration energy of subtle displacement of atoms and molecules. The resistance values of metallic lines or
semiconductors change by temperature. An electromotive force can occur if the connecting point of dissimilar metals is heated. The digital temperature
sensor measures the resistance or the electromotive force to measure the temperature.

Feature
The system prints out measured temperature vales in digitalized signals. Therefore, data management is easier, and it also prevents degradation caused
by noise. The sensor is energy efficient, and suitable for measuring temperature in wide areas.

The Structure of the Temperature Sensor


[ Factory ]
[DTS Configuration Example]

Temperature Sensor Module

Amplifying Circuit

Digital Converting Circuit

[Trend screen]

Digital Temperature Sensor


Temperature Sensor Module
- The current voltage characteristic changes in accordance with the temperature
variation at the P-N connecting point.

Amplifier Circuit
- In order to amplify the weak signal of the sensor data, an amplifier circuit has been
installed in the sensor.
- Potential exterior noise during signal amplifications has been eliminated.

BTMS

Digital Converting Circuit


- Digitalized temperature value output
- Easy data management and prevention of the degradation caused by noise

[GUI Configuration Example]

84

BTMS LS C&S-Busway System

BTMS LS C&S-Busway System

85

. Component

06 / 07

MPTS
The data collected by the sensor is gathered and saved at the data collection system, and monitored by a surveillance PC.

MPTS Application
Drawing up a draft plane is easier thanks to the graphic configuration of HMI, and managing the points using the remote observation system
reduces the work loads.

MPTS Setup
4

3
1

Main Screen

Location Screen

Displays the temperature monitoring points

Displays the locations of the temperature monitoring points

Alarm Screen

Trend Screen

Displays the abnormalities, details and location

- Displays the temperature variation trend

Configuration
No.

Feature

Sensor Module

Digital temperature sensor module with communication function

Data Collection Device

Collecting and transmitting of the temperature data of the sensor module

Power Supply Device

Supply power using the sensor module

Monitoring PC

Monitoring measure values through HMI


(data set-up, measuring, data log and information reference function)

BTMS LS C&S-Busway System

BTMS

86

Specifics

BTMS LS C&S-Busway System

87

. Component

06 / 07

IR-Ts
IR-Ts Preview

IR-Ts Configuration

The IR-Ts uses an infrared light noncontact temperature sensor to


measure and monitor the heat released from objects. The system is
suitable for dangerous environments including high voltage areas, or
areas where contact sensors are not feasible.

Temperature Sensors

Data Collection Device

IR-Ts : Infrared Camera

Feature
1) Compact and light weight
2) Can be installed at all directions
3) Applicable Temperature Range: -20C~ 200C
4) Real time temperature variation measurement and video (CCTV Camera)
5) Wire or wireless communication network system

*
*
*

IR-Ts (CCTV)
: Infrared Camera + CCTV

*
*
*

Installation
(Exterior image of the distribution board)
- PC*
*
*

1) Infrared Camera(IR Cam)

88

BTMS LS C&S-Busway System

BTMS

Photographic Measuring

- 16EA 2) CCTV

3) Composite photograph of IR+CCTV

BTMS LS C&S-Busway System

89

Global Network

LSCD (New Delhi, India)

LSCA (Atlanta, USA)

Yichang, China

Branches
Sydney Office

Houston Office

Manila Office

Peru Office

Level 35, Suite 35.02 Northpoint 100 Miller St. North Sydney, NSW 2060 Australia
Tel. +61-2-9460-0255
S-1903 B, West Tower, Philippine Stock Exchange Centre Exchange Rd.
Ortigas Center, Pasig City, Philippines
Tel: +63-2-6875028

Jakarta Office

22126 Manor Estates Dr. Katy, TX77449, USA


Tel: +1-713-202-8003
Av. Dos de mayo No.516 Oficina 307 Miraflores Lima 18 Peru
Tel : +51-1-221-9786

Graha Mustika Ratu, 11th Fl. Jl.Jenderal Gatot Subroto Kav.74-75,


Jakarta Selatan 12870 Indonesia
Tel. +62-21-830-6733

Subsidiaries

Singapore Office

LS Industrial Park, Xin Mei Rd. National High-tech Industrial Development Zone
Wuxi, Jiangsu Province 214028 China
Tel : +86-510-8534-5943
Production : Automotive Wire & Cable, Bus Duct, Electroncic Wire & Cable, Tube, ACF,
Accessories for EHV Cable System

300 Beach Rd. #25-07 The Concourse Singapore 199555


Tel. +65-6342-9162~3

Abu Dhabi Office

#133, Al Bateen Towers C6, Bainunah St.34, Al Bateen,


P.O.Box 113 100, Abu Dhabi, U.A.E
Tel : +971-2-406-9856

Riyadh Office

#7, 2nd Fl. Olaya St. B/D #28, Riyadh, Saudi Arabia
Tel : +966-1-201-3515

Cairo Office

#36, El-Zeini Tower, 25 Misr Helwan Rd. Maadi, Cairo, Egypt


Tel. +20-19-966-2810

Johannesburg Office

3rd Fl. South Tower at Nelson Mandela Square,Corner 5th Ave. and
Maude St. Sandton, Johannesburg, South Africa
Tel. +27-11-783-6320

Moscow Office

Park Place Tower E711, 113/1 Leninsky Prospect, Moscow 117198 Russia
Tel : +7-495-662-3811~14

LSCW

LSCT

East of Jing-jin Express, Yixingbu Entrance, Beichen Tianjin, China


Tel : +86-22-2699-7618
Production : Magnet Wire

China R&D Center(Yichang)

#1 Tanjiahe Rd. Dianjun District, Yi-Chang City, Hubei Province 443004 China
Tel. 070-8650-2188

LSHQ

#1 Tanjiahe Rd. Dianjun District, Yi-Chang City, Hubei Province 443004 China
+86-717-667-7777
Production : Power Cable, Submarine Cable, Industrial Specialty Cable

LS-VINA(Haiphong)

South of Binh Bridge St. So Dau Precinct, Hong Bang Dt. Haiphong, Vietnam
Tel. +84-31-540750
Production : EHV Power Cable, ACSR, OPGW, SCR

LSCV(Hochiminh)

Nhon Trach Il-Lockhang IZ, Nhon Trach Dt. Dong Nai province, Hochiminh, Vietnam
Tel. +84-61-356-9037
Production : MV/LV Cable, Data Cable

LSCM(Penang)

Lot 1192, Mukim 14, Permatang Tinggi, 1400 Bukit Mertajam, Penang, Malaysia
Tel. +60-4-588-9609(Ext.34)
Production : Magent Wire

LSCI(Haryana)

#101, 1st Fl. Park Center, Sector-30, Gurgaon, Haryana 122002. India
Tel : +91-124-4285800~4
Production : RF Feeder Cable, Power Cable, OPGW

LSCD : Marketing and sales

12th Fl. IFCI Tower 61 Nehru Place, 110019 New Delhi, India
Tel : +91-4167-1588

LSCA : Marketing and sales

Korea Operations
Headquarters

LS Tower, 1026-6 Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do 431-830 Korea


Tel. +82-2-2189-9114

Anyang Plant

555 Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do 431-830 Korea


Tel. +82-31-428-4114
Production : Automotive Wire, Tube Components, HV Cable & Connectors,
Bus Duct, Flooring System

Gumi Plant

190 Gongdan-dong, Gumi-si, Gyengsangbuk-do 730-708 Korea


Tel. +82-54-469-7114
Production : Power Cable up to 500kV, OHTL, OPGW, Data Cable,
RF Feeder System, Copper Rod, Magnet Wire

Indong Plant

6120 Powers Ferry Road, Atlanta, GA 30339, USA


Tel. +1-770-657-6141

643 Jinpyeong-dong, Gumi-si, Gyengsangbuk-do 730-735 Korea


Tel. +82-54-469-7763
Production : Industrial Cable & Module, Optical Cable, Aluminum Materials

LSCU : Marketing and sales

Donghae Plant

#109, Building 3, Chiswick Busuness Park 566 Chiswick High Rd.


London, W4 5YA, UK
Tel. +44-20-8899-6671

1377 Songjeong-dong, Donghae-si, Gangwon-do 240-806 Korea


Tel. +82-33-820-3114
Production : Submarine Cable, Industrial Specialty Cable

LSCJ : Marketing and sales

R&D Center

E 16th Fl. Akasaka Twin Tower 17-22, 2-Chome Akasaka, Minato-ku, Japan
Tel. +81-3-3582-9129

200 Dangjeong-dong, Gunpo-si, Gyeonggi-do 431-831 Korea


Tel : +82-31-450-8114

Anda mungkin juga menyukai