TOYTEST
Toy Safety Analytes Proficiency Testing Scheme
Scheme Description
LGC Standards
Proficiency Testing
1 Chamberhall Business Park
Chamberhall Green
Bury
Lancashire
BL9 0AP
United Kingdom
Telephone:
Fax:
Email:
Website
Issue: 15
Page 1 of 10
ISSUE
DATE
AUTHORISED
BY
31/10/08
03/07/09
M.Whetton
08/01/10
M.Whetton
23/03/11
Sep 2011
M.Whetton
Feb 2012
Amendments to appendices.
M.Whetton
Sept 2012
M.Whetton
Oct 2012
M.Whetton
10
Sept 2013
W.Gaunt
11
Sept 2014
W.Gaunt
12
April 2015
W.Gaunt
13
Sept 2015
14
Jan 2016
W.Gaunt
15
Sept 2016
W.Gaunt
DETAILS
T.Noblett
N.Stephenson
A.McCarthy
W.Gaunt
Notes:
Where this document has been translated, the English version shall remain the definitive version
Issue: 15
Page 2 of 10
Issue: 15
Page 3 of 10
From the robust mean (median) of participant results (RMean). This is the median of participant
results after the removal of test results that are inappropriate for statistical evaluation, e.g.
miscalculations, transpositions and other gross errors. Generally, the assigned value will be set
using results from all methods, unless the measurement is considered method-dependant, in
which case the assigned value will be set by method as illustrated in the report tables.
For some analytes, where there is a recognised reference method for that type of measurement,
this may be used as the assigned value for a particular analyte i.e. it would be applied to results
obtained by any method.
Traceability: Assigned values which are derived from the participant results, or a sub-set of the
results are not traceable to an international measurement standard. The uncertainty of assigned
values derived in this way is estimated from the participant results, according to ISO 13528.
From a formulation value (Formulation). This denotes the use of an assigned value derived from
sample preparation details, where known and exact quantities of analyte have been used to
prepare the sample.
Traceability: Assigned values calculated from the formulation of the test sample are traceable,
via an unbroken metrological traceability chain, to an international measurement standard. The
measurement uncertainty of the assigned value is calculated using the contributions from each
calibration in the traceability chain.
From a qualitative formulation (Qual Form). This applies to qualitative tests where the assigned
value is simply based on the presence/absence of the analyte in the test material.
Traceability: Assigned values calculated from the qualitative formulation of the test sample are
traceable to a certified reference standard or a microbiological reference strain.
From expert labs (Expert). The assigned value for the analyte is provided by an expert
laboratory.
The results returned are reviewed and the assigned value for each clause listed is based on the
general consensus of participant results.
If the consensus of the participants is below 75% the identified clauses are each reviewed by
the TOYTEST advisory group to ascertain their overall opinion of the appropriate assigned
value with regards to the toy provided. If the overall consensus of the TOYTEST advisory group
disagrees with the general participant consensus then the assigned value is amended.
Issue: 15
Page 4 of 10
Where applicable the reasoning behind the assigned values provided for such clauses will be
provided in the main EN71-1 or ASTM F963 report.
Where both the relevant and not relevant options are both deemed to be valid options the assigned
value(s) will be removed and instead the participant results and comments will be provided along with
additional detailed comments on the applicability of the two reporting options
Range
This indicates the concentration range at which the analyte may be present in the test material.
SDPA
SDPA represents the standard deviation for proficiency assessment which is used to assess
participant performance for the measurement of each analyte. This may be a fixed value (as stated), a
percentage (%) of the assigned value or based on the robust standard deviation of the participant
measurement results, either across all methods or by method depending on whether the measurement
made is method dependent (see assigned value).
Units
This indicates the units used for the assessment of data. These are the units in which participants
should report their results. For some analytes in some schemes participants may have a choice of
which units to report their results, however, the units stipulated in this scheme description are the
default units to which any results reported using allowable alternative results will be converted to.
DP
This indicates the number of decimal places to which participants should report their measurement
results.
Issue: 15
Page 5 of 10
Sample 1
EN71-1
Analyte
Assessment to EN71-1
Method
N/A
Range
N/A
AV
Expert/ Consensus
Sample 7
ASTM F963
Analyte
Assessment to ASTM F963
Method
N/A
Range
N/A
AV
Expert/ Consensus
SDPA
N/A
Units
N/A
DP
N/A
SDPA
N/A
Units
N/A
DP
N/A
Additional testing
Standards
EN71-1 & ASTM F963
EN71-1 & ASTM F963
EN71-1
EN71-1 & ASTM F963
EN71-1 & ASTM F963*
Range
All
All
All
All
All
AV
RMean
RMean
RMean
RMean
RMean
SDPA
0.2
0.003
3
Robust SD
Robust SD
Units
mm
mm / inches
dB
Joules (J)
mm
EN71-2
Issue: 15
Method
N/A
Section 4.2.2
Section 4 (EN71-1)
Various
Range
N/A
All
All
N/A
AV
Expert
RMean
RMean
Qual Form
Page 6 of 10
SDPA
N/A
Robust SD
3
N/A
Units
N/A
seconds
mm/s
N/A
DP
N/A
0
1
N/A
DP
2
3
1
3
2
Sample 3
Analyte
Aluminium
Antimony
Arsenic
Barium
Boron
Cadmium
Chromium*
Chromium III
Cobalt
Copper
Lead
Manganese
Mercury
Nickel
Selenium
Strontium
Tin
Zinc
Method
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
Range
0 to 2
0 to 2
0 to 2
0 to 20
0 to 2
0 to 2
0 to 20
0 to 20
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 5
0 to 10
0 to 2
0 to 2
0 to 2
AV
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
SDPA
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
10% of AV
Units
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
DP
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
SDPA
10% of AV
10% of AV
Units
g/L
g/L
DP
2
2
Analyte
Chromium VI
Organic tin
Method
All
All
Issue: 15
Range
0 to 1000
0 to 1000
AV
Formulation
Formulation
Page 7 of 10
Sample 3
Analyte*
Aluminium
Antimony
Arsenic
Barium
Boron
Cadmium
Chromium**
Chromium III
Chromium VI
Cobalt
Copper
Lead
Manganese
Mercury
Nickel
Selenium
Strontium
Tin
Organic tin
Zinc
Method
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
Range***
0 to 200
0 to 60
0 to 200
0 to 250
0 to 200
0 to 50
0 to 100
0 to 100
0 to 1000
0 to 50
0 to 60
0 to 200
0 to 60
0 to 50
0 to 200
0 to 100
0 to 200
0 to 100
0 to 1000
0 to 200
AV
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
RMean
SDPA
Robust SD
30% of AV
30% of AV
15% of AV
Robust SD
15% of AV
15% of AV
Robust SD
Robust SD
Robust SD
Robust SD
15% of AV
Robust SD
25% of AV
Robust SD
30% of AV
Robust SD
Robust SD
Robust SD
Robust SD
Units
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
g/L or g/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
mg/L or mg/kg
g/L or g/kg
mg/L or mg/kg
DP
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Issue: 15
Page 8 of 10
Sample 5
EN71-8
Analyte
Assessment to EN71-8
Method
N/A
Range
N/A
AV
Expert
SDPA
N/A
Sample 6
EN71-9
Analyte
Assessment to EN71-9
Method
N/A
Range
N/A
SDPA
N/A
Units
N/A
DP
N/A
Range
AV
SDPA
Units
DP
All
Median
Robust SD
mg/kg
AV
Median
Median
SDPA
10% of AV
10% of AV
Units
mg/kg
mg/kg
DP
2
2
AV
Median
Median
SDPA
Robust SD
Robust SD
Units
% (w/w)
% (w/w)
DP
2
2
Section of material
Method
EN14362-1 &
EN14362-3
Azo dyes
Sample 9
Analyte
Total cadmium
Total lead
Method
All
All
Range
All
All
Sample 10
Analysis of phthalates
Analyte
BBP
DBP
Method
All
All
Issue: 15
DP
N/A
AV
Expert
Sample 8
Analyte
Units
N/A
Range
All
All
Page 9 of 10
DEHP
DnOP
DINP
DIDP
All
All
All
All
All
All
All
All
Sample 10
Analysis of phthalates
Analyte
BBP
DBP
DEHP
DnOP
DINP
DIDP
Method
All
All
All
All
All
All
Range
All
All
All
All
All
All
Median
Median
Median
Median
Robust
Robust
Robust
Robust
AV
Formulation
Formulation
Formulation
Formulation
Formulation
Formulation
SDPA
10% of AV
10% of AV
10% of AV
15% of AV
15% of AV
15% of AV
Units
mg/L
mg/L
mg/L
mg/L
mg/L
mg/L
DP
2
2
2
2
2
2
SDPA
Robust SD
Units
kG2mm 2
DP
2
SDPA
-
Units
K
DP
1
Sample 14***
Analyte
Flux testing
Method
All
Range
All
AV
Median
Sample 15***
Electrical testing
Analyte
Temperature rise
Method
EN62115
Range
-
AV
-
SD
SD
SD
SD
%
%
%
%
(w/w)
(w/w)
(w/w)
(w/w)
2
2
2
2
Issue: 15
Page 10 of 10