1. Introduction
2. Caution
3. Installation
3.1. Packing List
3.2. Placement
3.3. Connection
4. Operation
4.1. Operating Instructions
4.2. UPS Status Information
4.3. Front Panel Explanation
4.4. Rear Panel Explanation
5. Battery Usage
6. Trouble Shooting
7. Specifications
8. Technical Support
1. INTRODUCTION
Thank you for buying PROLiNK Uninterruptible Power Supply (UPS) device.
Our device is designed for many years of reliable usage when installed properly.
Why do you need an UPS?
- Among the various causes of data loss, 45% of them are due to power supply. We can make a
conclusion that if we can resolve this problem, then we can prevent half of the data loss
situations that we will face.
- Temporary power supply interruption and total power blackout only make up 13% of the
problems. What we are most concerned with is temporary power surge or drop, which makes
up another 87% of the power supply problems that we are currently facing.
- The most crucial reason to use an UPS is not to just obtain continuous power source, but also a
clean and noiseless current. Hence, one of the most important functions of UPS is to provide a
stable current output.
PROLiNK Uninterruptible Power Supply (UPS) is a device that sits between a power supply
(e.g. a wall outlet) and a device (e.g. a computer) to prevent undesired interference of the power
source (outages, sags, surges, bad harmonics, etc.) from adversely affecting the performance of
the device.
PROLiNK UPS has internal batteries to guarantee that continuous power is supplied to the
equipment even if the power source stops providing power. The UPS can provide power for a
while, typically 20 to 50 minutes, depending on the capacity of the battery but that is often enough
to ride out power glitches or short outages.
The advantages are as below:
1. Computer jobs dont stop because of power failure.
2. Users are not inconvenienced by computer shutting down.
3. Equipment does not incur the stress of another (hard) power cycle.
4. Data is not lost because a machine shut down without doing a sync or equivalent to flush
cached or real time data.
In addition, PRO650S, PRO800S, PRO850S, PRO1200S & PRO1500S with RUPS 2000
software combinations provide the following functions:
1. Automatic shutdown of equipment during long power outages.
2. Monitoring and logging of the status of the power supply.
3. Display the Voltage/Current drawn by the equipment.
4. Display the Voltage currently on the Line.
5. Provide alarms on error conditions.
6. Review last shutdown information of Windows applications.
7. Broadcast abnormal power status to all workstations.
2. CAUTION
The UPS battery has been fully charged before leaving our factory. During the shipment,
some level of power may have been discharged. In order to ensure the efficiency of the UPS,
please allow the UPS to charge its battery for at least 12 hours before use.
Connect the UPS to a two-pole, three-wire grounding mains (AC). The AC source must be
connected to appropriate branch protection (fuse or circuit breaker). Connection to any other
type of AC source may result in a shock hazard and may violate your warranty claim.
This UPS has an internal battery and its energy can not be de-energized by the user. The
output may be energized even though when the UPS is not connected to the main AC.
DO NOT install the UPS in locations where there is water or excessive humidity.
DO NOT allow water or any foreign object to enter the UPS or put any objects containing
liquid on or near the UPS.
DO NOT remove the cover. No user serviceable parts. Refer servicing to qualified service
personnel.
DO NOT connect any non-computer peripherals to the UPS. The UPS is designed for use
with computer loads only.
To reduce the risk of overheating the UPS, avoid exposing the unit to direct sunlight. Avoid
installing the unit near heat emitting appliances such as a room heater or stove.
3. INSTALLATION
3.1 Packing List
Inspect the UPS upon receipt. Once the UPS is removed from its packing, it should be
inspected for damage that may occur while transit. However, if damage to your UPS has
occurred, kindly inform your dealer immediately for replacement. The packaging is
recyclable; save it for reuse or dispose it properly. You may wish to keep the packaging box
for future transportation of your UPS to another location.
Model
PC650
PRO650P/B
PRO650P
PRO650P/Y
PRO650S
Packing
List
1 PC650
UPS
1 PRO650P/B
UPS
1 PRO650P
UPS
1 PRO650P/Y
UPS
1 PRO650 UPS
1 Manual
1 Manual
1 Manual
1 Manual
1 Fuse
1 Fuse
1 Power
Cable (builtin)
1 Power
Cable (builtin)
1 RJ11
Cable
1 RJ11
Cable
1 Fuse
1 Fuse
1 Power
Cable (builtin)
2 Power
Cable (UPS
to load)
1 Manual
1 RJ11 Cable
1 RS232 Cable
1 Fuse
2 Power Cable
(UPS to load)
1 monitoring
software
Model
PRO800S
PRO850S
PRO1200S
PRO1500S
Packing
List
1 PRO800S UPS
1 PRO850S UPS
1 PRO1200S UPS
1 PRO1500S UPS
1 Manual
1 Manual
1 Manual
1 Manual
1 RJ11 Cable
1 RJ11 Cable
1 RJ11 Cable
1 RJ11 Cable
1 RS232 Cable
1 RS232 Cable
1 RS232 Cable
1 RS232 Cable
2 Power Cable
(UPS to load)
2 Power Cable
(UPS to load)
3 Power Cable
(UPS to load)
3 Power Cable
(UPS to load)
1 monitoring
software
1 monitoring
software
1 monitoring
software
1 monitoring
software
3. INSTALLATION
3.2 Placement
The UPS works best in a protected environment. The location should provide adequate air
flow around the unit, in an atmosphere free from excessive dust.
DO NOT operate the UPS in an environment where the ambient temperature and humidity is
outside or near the limits.
Temperature limits: 0C - 40C (32 - 104F)
Humidity: 0% - 95% relative humidity
Select a location sturdy enough to handle the heavy weight of the UPS.
3.3 Connection
PC650
PRO650P/B
PRO800S
PRO650P
PRO850S
PRO650PY
PRO1200S
PRO650S
PRO1500S
3. INSTALLATION
1. Install the RUPS2000
A.
Connect the serial cable to the UPS and computer serial port
monitoring software to you computer. (Optional)
B.
Connect UPS into a two pole, three wire, grounded receptacle only 2. Avoid using
extension cords. Using the telephone cable provided, plug the cable into the telephone
socket in the UPS 4. Plug other end of the telephone cable to the telephone wall socket.
DO NOT turn on the connected equipment before turning on the UPS. Turn on the UPS
first and turn on the connected equipment. This will prevent overloading of the UPS.
F.
To power up the UPS, press the power switch on the front panel.
4. OPERATION
4.1 Operating Instructions
A.
Connect the AC input power cable of your UPS to the AC Power. (See connections for
help). CHARGE LED on the UPS front panel is lit. UPS is charging the battery.
B.
Plug computer and monitor to UPS sockets. (Note: Power of computer and monitor
must be less than the maximum total power of your UPS.)
C. Switch on the UPS by pressing the power switch on the front panel. The NORMAL and
CHARGE LED on the UPS front panel are lit. UPS is supplying utility power to the
connected equipment and is still charging battery at the same time. If the LED is not lit,
the UPS is either not turned ON or is supplying battery power.
D. When external power source fails, the UPS will power up automatically by batteries.
The INVERTER LED is blinking and the UPS has beep sound every 5 seconds. You
should save all your data and close all applications as soon as possible and turn off the
UPS. If RUPS software or other compatible software is installed, your data will be saved
automatically, all applications including your UPS will shut down automatically. This
prevents drainage to your UPS battery and prolongs the life of your battery. This action
also prevents hard disk crash situations when power failure occurs.
E.
When the battery output voltage drops to a minimum, the INVERTER LED on the UPS
front panel is continues lit while generating beeps twice every second. You should turn
off the main switch of the UPS. This happens usually if no UPS management software
is installed.
F.
It is normal that the CHARGE LED is on at all times. This feature prolongs the life of
the battery and prevent over drainage of the battery.
Buzzer
Yellow
CHARGE
Green
NORMAL
Red
INVERTER
No beeps
ON
OFF
OFF
No beeps
ON
ON
OFF
AC abnormal
UPS in battery mode
OFF
OFF
Blinking
OFF
OFF
ON
Overload
OFF
OFF
ON
Beeps continuously
OFF
OFF
ON
Discharge Finished
No beep
OFF
OFF
OFF
4. OPERATION
4.3 Front Panel Explanation
CHARGE LED
ON when UPS is charging battery.
OFF when AC is abnormal.
NORMAL LED
ON when UPS is running normal.
OFF when UPS is off or abnormal.
INVERTER LED
Blinking when UPS is on battery power.
ON when battery voltage low, UPS overload, short circuit or fault.
OFF when UPS is running normal or UPS is off.
MAIN SWITCH
To control ON / OFF the UPS when utility power is normal.
PC650
PRO650P/B
PRO800S
B. Backup Outlets
D. Computer Interface
F. AC Fuse Holder (W/fuse)
PRO650P
PRO850S
PRO650PY
PRO1200S
PRO650S
PRO1500S
5. BATTERY USAGE
Please kindly refer to the below mentioned scenarios to rectify if you are facing the
common issue on your battery for your UPS.
5. BATTERY USAGE
5.2 Battery - No Backup
A.
It is the same issue as scenario 1. Due to no charging and discharging activities for
2 to 3 months on the battery upon date of production will also cause the battery to
lose its activity level totally in this instance.
B.
The external condition of transportation is another factor that will cause the battery
to lose its activity level totally.
Under the UPS usage circumstances, when inconsistent power supply is detected,
the battery will be running through the charging and discharging cycles frequently
and therefore, the battery life span will be shorter than expected. Our batteries are
designed to have 500 cycles of 50% DOD (Depth of Discharging) according to our
production standard.
B.
*According to the international JISC8702-1998 standard, batteries for the UPS are designed
to last for last for 200 cycles of charging and discharging only.
6. TROUBLE SHOOTING
Problem
Possible Cause
1)
2)
3)
4)
Solution
1)
2)
3)
4)
1)
UPS beeps occasionally on
AC mode and UPS may be
heated up.
2)
1)
1)
Battery backup time is
short. Long beeping sound
is heard.
2)
3)
1)
2)
3)
UPS may be
overloaded.
Battery not fully
charged.
Battery may be near
the end of its lifespan.
2)
3)
1)
2)
3)
Turn on AC power.
Insert power cable
properly.
Change the fuse.
Change to another wall
socket.
Check that your
equipment matches the
specified capacity of
your UPS. Do not
overload your UPS.
Refer to qualified
electrical technician to
check your AC supply
and wiring.
Remove any non
critical equipment.
Charge the battery for
at least 8 hours before
use.
Refer to supplier for
replacement of battery
(charges may be
involved).
7. SPECIFICATIONS
Model
PRO650P
PRO650PY
PRO650P/B
PC650
Capacity
Input
650VA
Voltage Range
160 275V
140 285V
Frequency
40Hz - 70Hz
Phase
Output
Single + GND
Voltage Range
220VAC (rating)
Battery Mode
220VAC 15%
Waveform
2ms typical
12V7AH 1pc
Yes
Overload Protection
Yes
Audible & Visual
>75C Alarm will sound
>85C the system will shutdown
Line Mode: 100-120% alarm for 3 minutes & shut down;
120-130% alarm for 30s & shut down;
>130% shuts down immediately
Battery Mode: 100 110% gives alarm & shut down in 10s;
>110% shut down immediately
General
12V7.2AH 1pc
8 20 minutes depending on load
Recharge Time
Interface
Backup Time
Protection/
Monitoring
Frequency
Transfer Time
Battery
PRO650S
Interface
NA
9P D-Type Connector
NA
NA
AC Fault, Battery
Low, Shutdown UPS
Software (optional)
NA
NA
Supports Netware
3.xx, Windows NT,
Unix, Sun OS, HPUX, etc.
Noise
<45dB
Temperature
Humidity
Power Factor
Built-in AVR
0C - 40C
0% - 95% relative humidity
Up to 0.7
Yes
Full AVR
7. SPECIFICATIONS
Model
Capacity
Input
Output
PRO800S
PRO850S
PRO1200S
PRO1500S
800VA
850VA
1200VA
1500VA
Voltage Range
140 285VAC
Frequency
40Hz - 70Hz
Phase
Single + GND
Voltage Range
Battery Mode
Frequency
Waveform
Transfer Time
Battery
2ms typical
12V10AH 1pc
Backup Time
Surge Protection
Yes
Overload Protection
Yes
Audible & Visual
>75C Alarm will sound
>85C the system will shutdown
Line Mode: 100-120% alarm for 3 minutes & shut down;
120-130% alarm for 30s & shut down;
>130% shuts down immediately
Battery Mode: 100 110% gives alarm & shut down in 10s;
>110% shut down immediately
Intelligent Battery
management
Interface
Interface
9P D-Type Connector
Software (optional)
General
12V9AH 2pc
12V7AH 2pc
Recharge Time
Protection/
Monitoring
12V10AH 1pc
Noise
Temperature
Humidity
<45dB
0C - 40C
0% - 95% relative humidity
Power Factor
Up to 0.7
Built-in AVR
Full AVR
8. TECHNICAL SUPPORT
FREE TECHNICAL SUPPORT HOTLINE:
Mon to Fri: 9am - 6pm
(Closed on Saturdays, Sundays & Public Holidays)
Singapore
Malaysia
Indonesia
WALK-IN:
Mon to Fri: 9am - 6pm
(Closed on Saturdays, Sundays & Public Holidays)
Singapore
FIDA INTERNATIONAL (S) PTE LTD
Blk 16 Kallang Place #06-02
Kallang Basin Industrial Estate Singapore 339156
Malaysia
FIDA SYSTEMS (M) SDN BHD
29 USJ 1/31, 47600 Subang Jaya Selangor,
Darul Ehsan, Malaysia
Indonesia
PROLiNK INDONESIA
Jl. Cideng Barat No. 79, Jakarta Pusat 10150, Indonesia
ISI Buku
1. Pendahuluan
2. Perhatian
3. Instalasi
3.1. Isi Kemasan
3.2. Penempatan
3.3. Koneksi
4. Penggunaan
4.1. Instruksi Penggunaan
4.2. Informasi Status UPS
4.3. Penjelasan Panel Depan
4.4. Penjelasan Panel Belakang
5. Penggunaan Baterai
6. Permasalahan dan Solusi
7. Spesifikasi Produk
8. Teknikal bantuan
1. PENDAHULUAN
Terima kasih telah membeli PROLiNK Uninterruptible Power Supply (UPS).
Produk ini di design untuk penggunaan dalam waktu yang lama apabila digunakan dengan
benar.
Mengapa UPS dibutuhkan?
- Dalam beberapa hal penyebab kehilangan data, 45% berasal dari listrik. Kita bisa
membuat suatu kesimpulan bahwa jika kita dapat memecahkan masalah ini, kita dapat
mencegah sebagian dari penyebab kerugian data (Data Loss).
- Padamnya arus listrik dan gangguan blackout hanya hanya 13% dari total permasalahan
dari listrik. Sisanya 87% adalah berasal dari voltase listrik yang tidak stabil.
- Alasan yang paling tepat untuk menggunakan UPS adalah bisa menstabilkan listrik dan
yang paling penting adalah pada saat listrik mati secara tiba-tiba, komputer tetap akan
terselamatkan karena UPS tetap akan menyediakan listrik selama waktu tertentu.
PROLiNK Uninterruptible Power Supply (UPS) adalah suatu alat yang berada diantara
listrik dari PLN dan Komputer dimana alat ini dapat mencegah perubahan dari listrik yang
terjadi secara tiba-tiba.
PROLiNK UPS mempunyai baterei internal untuk menjamin listrik yang berlanjut pada saat
sumber listrik dari PLN padam. Tentu saja UPS dapat menyediakan listrik untuk beberapa
waktu, secara khas beberapa menit, tetapi itu sudah cukup untuk mempertahankan data kita
yang penting.
Keuntungan :
1. Pekerjaan komputer tidak akan terhenti apabila listrik padam.
2. Para pengguna akan sempat mematikan komputer secara normal.
3. Peralatan akan lebih tahan lama dari kerusakan yang disebabkan oleh listrik.
4. Data tidak akan hilang apabila listrik padam secara tiba-tiba.
Sebagai tambahan, PRO650S, PRO800S, PRO850S, PRO1200S dan PRO1500S
dilengkapi dengan software RUPS 2000 yang menyediakan fungsi sebagai berikut :
1. Dapat menshutdown komputer secara otomatis selama listrik padam.
2. Dapat memonitoring status dari UPS dan Listrik yang ada.
3. Dapat melihat kapasitas beban yang ada pada saat itu.
4. Dapat melihat voltase yang ada pada saat itu.
5. Tersedia alarm untuk memberikan tanda pada kondisi tertentu.
6. Mempunyai log yang dapat memberikan informasi shutdown terhadap aplikasi.
7. Memberikan peringatan kepada kita apabila ada status yang tidak normal.
2. PERHATIAN
Baterei UPS sudah diisi penuh sebelum keluar dari pabrik. Selama pengiriman, kapasitas
dari isi baterei akan berkurang. Untuk memastikan efisiensi dari UPS, sebaiknya baterei
diisi kembali sebelum digunakan selama 12 jam.
Hubungkan UPS ke pusat listrik dengan menggunakan kabel 3 pin (berikut grounding).
Grounding ini sangat berguna untuk memproteksi peralatan kita dari petir.
UPS ini mempunyai baterei internal dan energi nya tidak bisa dibuang. Output dari UPS
sendiri akan mengeluarkan arus listrik walaupun UPS tidak dihubungkan langsung ke aliran
JANGAN meletakan UPS di dekat daerah yang lembab atau basah.
JANGAN biarkan air atau benda asing lain nya masuk kedalam UPS.
JANGAN membuka casing UPS atau melakukan reparasi sendiri.
JANGAN gunakan UPS ini ke peralatan yang bukan peralatan komputer. UPS ini hanya di
rancang untuk digunakan oleh peralatan komputer saja.
Untuk mengurangi resiko panas yang berlebihan dari UPS, jangan meletakan UPS yang
langsung terkena sinar matahari atau hindari peletakaan yang dekat dengan peralatan yang
mengeluarkan panas.
3. INSTALASI
3.1 Isi Kemasan
Perhatikan isi UPS pada saat membeli. Jika ditemukan UPS dalam keadaan cacat fisik,
segeralah untuk menukarkannya dengan yang baru. Kotak UPS dapat di daur ulang, bisa
disimpan atau dibuang, namun ada baik nya kalau kotak disimpan untuk dapat digunakan
kembali.
Model
PC650
PRO650P/B
PRO650P
PRO650P/Y
PRO650S
Isi
Kemasan
1 PC650
UPS
1 PRO650P/B
UPS
1 PRO650P
UPS
1 PRO650P/Y
UPS
1 PRO650 UPS
1 Buku
Manual
1 Buku
Manual
1 Buku
Manual
1 Buku
Manual
1 Sekering
1 Sekering
1 Kabel
Power (builtin)
1 Kabel
RJ11
1 Kabel
RJ11
1 Kabel RS232
1 Kabel
Power (builtin)
1 Sekering
1 Sekering
1 Kabel
Power (builtin)
2 Kabel
Power (ke
peralatan)
2 Kabel Power
(ke peralatan)
1 Buku Manual
1 Kabel RJ11
1 Sekering
1 monitoring
software
Model
PRO800S
PRO850S
PRO1200S
PRO1500S
Isi
Kemasan
1 PRO800S UPS
1 PRO850S UPS
1 PRO1200S UPS
1 PRO1500S UPS
1 Buku Manual
1 Buku Manual
1 Buku Manual
1 Buku Manual
1 Kabel RJ11
1 Kabel RJ11
1 Kabel RJ11
1 Kabel RJ11
1 Kabel RS232
1 Kabel RS232
1 Kabel RS232
1 Kabel RS232
1 monitoring
software
1 monitoring
software
1 monitoring
software
1 monitoring
software
3. INSTALASI
3.2 Penempatan
UPS dapat bekerja dengan baik apabila diletakan pada tempat yang terjaga dengan baik.
Dimana lokasinya terdapat sirkulasi udara yang baik dan jauh dari debu.
JANGAN menggunakan UPS ditempat yang bertemperatur tinggi atau mendekati batas dari
kelembaban nya.
Batas Temperatur : 0C - 40C (32 - 104F)
Kelembaban: 0% - 95% kelembaban relative.
Pilihlah tempat yang sesuai dengan ukuran dan berat dari UPS yang digunakan.
3.3 Koneksi
PC650
PRO650P/B
PRO800S
PRO650P
PRO850S
PRO650PY
PRO1200S
PRO650S
PRO1500S
3. INSTALASI
1.
Install software
A.
B.
Sambungkan UPS ke sumber listrik yang mempunyai grounding yang baik 2. Jangan
menggunakan sambungan kabel listrik. Dengan menggunakan kabel telepon yang telah
disediakan, sambungkan kabel tersebut ke soket telepon yang ada pada UPS 4 dan
sambungkan sisi lain nya ke sumber line telepon anda.
F.
Untuk menghidupkan UPS, tekan tombol power pada panel depan UPS.
4. PENGGUNAAN
4.1 Instruksi Penggunaan
G. Sambungkan kabel power dari UPS ke sumber listrik (PLN). (Lihat bagian Koneksi
untuk bantuan). Lampu CHARGE akan menyala. Artinya UPS sedang melakukan
charging ke baterai.
H. Sambungkan komputer dan monitor anda ke output UPS. (Note: Total daya dari
komputer dan monitor harus lebih kecil dari kemampuan output daya maximum dari
UPS anda.)
I.
Nyalakan UPS dengan menekan tombol power yang ada pada panel depan. Lampu
NORMAL dan CHARGE akan menyala. Artinya UPS bekerja dengan menggunakan
listrik PLN dan tetap melakukan charging ke baterai dalam waktu yang bersamaan.
J.
Ketika sumber listrik padam, UPS akan bekerja secara otomatis dengan menggunakan
baterai. Lampu INVERTER akan berkedip dan diikuti dengan suara beep di setiap 5
detik. Saat ini anda harus menyimpan seluruh data anda dan matikan UPS secara
manual. Jika software RUPS2000 tersedia, maka data anda secara otomatis akan
tersimpan lalu komputer dan UPS anda juga akan mati secara otomatis. Hal ini
dilakukan untuk memperpanjang umur baterai anda. Juga untuk menghindari
kerusakan hardisk anda dari listrik yang padam secara tiba-tiba.
K.
Ketika output dari baterai melemah, lampu INVERTER akan terus berkedip dan diikuti
dengan suara beep 2 kali disetiap detik. Anda secepatnya harus mematikan UPS
secara manual. Ini sering terjadi untuk UPS jenis tanpa software monitoring.
L.
Normal apabila lampu CHARGE menyala terus. UPS ini mempunyai fitur untuk me
manage baterai anda.
Buzzer
Kuning
CHARGE
Hijau
NORMAL
Merah
INVERTER
HIDUP
MATI
MATI
HIDUP
HIDUP
MATI
MATI
MATI
Berkedip
MATI
MATI
HIDUP
MATI
MATI
HIDUP
UPS bermasalah
MATI
MATI
HIDUP
MATI
MATI
MATI
4. PENGGUNAAN
4.3 Penjelasan Panel Depan
Lampu CHARGE :
HIDUP ketika UPS sedang melakukan proses charging.
MATI ketika sumber listrik (PLN) padam.
Lampu NORMAL :
HIDUP ketika UPS bekerja normal.
MATI ketika UPS mati atau tidak normal.
Lampu INVERTER :
Berkedip ketika UPS bekerja dengan baterai.
HIDUP ketika baterai melemah, UPS overload, atau bermasalah.
MATI ketika UPS bekerja normal atau UPS mati.
Main Switch
Untuk mengontrol UPS HIDUP / MATI.
PC650
PRO650P/B
PRO800S
B. Backup Outlets
D. Computer Interface
F. AC Fuse Holder (W/fuse)
PRO650P
PRO850S
PRO650PY
PRO1200S
PRO650S
PRO1500S
5. PENGGUNAAN BATERAI
Hal yang perlu di perhatikan jika anda menemukan masalah pada baterai anda.
5. PENGGUNAAN BATERAI
5.2 Baterai Tidak dapat membackup
A.
Hal ini sama dengan tahapan seperti yang telah di sebutkan di atas. dalam
kaitannya dengan tidak adanya aktifitas proses pengisian dan pengosongan
baterai selama 2 hingga 3 bulan sejak baterai di produksi. Hal ini akan
menyebabkan battery tidak dapat bekerja secara maksimal membackup beban
yang ada.
B.
Transportasi juga merupakan salah satu faktor lainnya yang dapat menyebabkan
baterai tidak dapat bekerja secara maksimal membackup beban yang ada.
Pada saat UPS mendeteksi adanya ketidak stabilan aliran listrik yang masuk,
baterai akan berkerja dengan melakukan pengisian dan pengosongan secara
periodik di setiap kali aliran listrik naik dan turun, hal ini dapat menyebabkan umur
baterai menjadi lebih singkat dari kondisi yang seharusnya,
Baterai yang kami gunakan, di rancang untuk dapat bekerja 500 cycle dari kondisi
proses pengisian dan pengosongan, maka ini berarti baterai mengalami 50% DOD
(Depth of Discharging) melebihi dari standart produksi yang di tentukan.
B.
Pada suhu tinggi di lingkungan sekitar, hal ini juga dapat menyebabkan umur
baterai akan menjadi lebih pendek.
Possible Cause
Solution
1)
1)
Lampu LED tidak menyala
pada saat UPS
dihidupkan.
Lampu INVERTER
berkedip.
2)
3)
4)
2)
3)
4)
1)
1)
2)
2)
1)
1)
Waktu backup baterai yang
pendek.
Mengeluarkan bunyi beep.
2)
3)
1)
2)
3)
2)
3)
1)
2)
3)
7. SPESIFIKASI PRODUK
Model
PRO650P
PRO650PY
PRO650P/B
PC650
Capacity
Input
650VA
Voltage Range
160 275V
140 285V
Frequency
40Hz - 70Hz
Phase
Output
Single + GND
Voltage Range
220VAC (rating)
Battery Mode
220VAC 15%
Waveform
2ms typical
12V7AH 1pc
Yes
Overload Protection
Yes
Audible & Visual
>75C Alarm will sound
>85C the system will shutdown
Line Mode: 100-120% alarm for 3 minutes & shut down;
120-130% alarm for 30s & shut down;
>130% shuts down immediately
Battery Mode: 100 110% gives alarm & shut down in 10s;
>110% shut down immediately
General
12V7.2AH 1pc
8 20 minutes depending on load
Recharge Time
Interface
Backup Time
Protection/
Monitoring
Frequency
Transfer Time
Battery
PRO650S
Interface
NA
9P D-Type Connector
NA
NA
AC Fault, Battery
Low, Shutdown UPS
Software (optional)
NA
NA
Supports Netware
3.xx, Windows NT,
Unix, Sun OS, HPUX, etc.
Noise
<45dB
Temperature
Humidity
Power Factor
Built-in AVR
0C - 40C
0% - 95% relative humidity
Up to 0.7
Yes
Full AVR
*Spesifikasi produk dapat berubah sewaktu-waktu tanpa adanya pemberitahuan terlebih dahulu.
7. SPESIFIKASI PRODUK
Model
Capacity
Input
Output
PRO800S
PRO850S
PRO1200S
PRO1500S
800VA
850VA
1200VA
1500VA
Voltage Range
140 285VAC
Frequency
40Hz - 70Hz
Phase
Single + GND
Voltage Range
Battery Mode
Frequency
Waveform
Transfer Time
Battery
Protection/
Monitoring
Overload Protection
Intelligent Battery
management
Interface
Interface
9P D-Type Connector
Software (optional)
General
Noise
Temperature
Humidity
2ms typical
12V10AH 1pc
12V10AH 1pc
12V7AH 2pc
12V9AH 2pc
Power Factor
Up to 0.7
Built-in AVR
Full AVR
*Spesifikasi produk dapat berubah sewaktu-waktu tanpa adanya pemberitahuan terlebih dahulu.
8. TEKNIKAL BANTUAN
TALIAN UNTUK BANTUAN TEKNIKAL:
Isnin hingga Jumaat: 9am 6pm
(Tutup pada hari Sabtu, Ahad dan Hari Cuti Awam)
Singapura
Malaysia
Indonesia
KEMASUKAN:
Talian Untuk Bantuan Teknikal:
Isnin hingga Jumaat: 9am 6pm
(Tutup pada hari Sabtu, Ahad dan Hari Cuti Awam)
Singapura
FIDA INTERNATIONAL (S) PTE LTD
Blk 16 Kallang Place #06-02
Kallang Basin Industrial Estate Singapore 339156
Malaysia
FIDA SYSTEMS (M) SDN BHD
29 USJ 1/31, 47600 Subang Jaya Selangor,
Darul Ehsan, Malaysia
Indonesia
PROLiNK INDONESIA
Jl. Cideng Barat No. 79, Jakarta Pusat 10150, Indonesia
BANTUAN TEKNIKAL:
support@fida.com
www.prolink2u.com
SINGAPORE
FIDA INTERNATIONAL (S) PTE LTD
Block 16 Kallang Place, #06-02 Kallang Basin Industrial Estate, Singapore 339156.
Tel : (65) 6357 0668
Email : support@fida.com
MALAYSIA
FIDA SYSTEMS (M) SDN BHD
29 Jalan USJ 1/31, 47600 Subang Jaya, Selangor Darul Ehsan, Malaysia.
Tel : (60) 3 8024 9151
Email : support_my@fida.com
INDONESIA
PROLiNK INDONESIA
Jl. Cideng Barat No. 79, Jakarta Pusat 10150, Indonesia.
Tel : (62) 21 3483 1777 Email : support@prolink.co.id
PROLiNK is a trademark of Fida International (S) Pte Ltd and is manufactured under its authority. All
other brands, products, services, logos and company names mentioned herein are trademarks of their
respective owners. All specifications, designs and contents are subject to changes without prior notice.
Copyright 2009. PROLiNK all rights reserved.