ADVERTENCIA
WARNING
WARNING
Ciertas piezas internas no tienen conexin a tierra en
SERVICE INFORMATION
DO NOT REMOVE/RENSEIGNEMENTS RELATIFS LENTRETIEN NE PAS ENLEVER
BOTTOM VIEW / VUE DE DESSOUS
Attache de puisard/ Dtecteur dinondation/
Sump Clip Flood
Puisard/ Bote de raccordement/
Sensor
Sump
Junction Box
Control Box/ Control
Attache de puisard/
Bote de commande
Box
Sump Clip
Water
Water Valve/
RobinetValve
deau
Wash
Wash Pump/
Pompe
Pump de lavage
High Drain
High
Loop/Drain
BoucleLoop
de
vidange
suprieure
Tub
Tub TCO/
TCO
TCO de la cuve
Drain Pump/
Drain Sump
Heater/
PompePump
de
Clip/
pidange
Attache lment
chauffant
de
puisard
Diverter/
Dispositif de
drivation
Lower Spray
Arm/
Lower
Bras gicleurSpray
infrieur Arm
Conduit Adapter
Conduit
Plate/
Adapter
Plaque dadaptation
du conduit Plate
ConduitConduit
Gasket/
Joint dtanchit
Gasket
du conduit
Fine Fine
Filter
FiltreFilter
fin
Vent
VentCaps/
Capuchons
de
Caps
ventilation
Heating
HeatingElement/
lment
Elementchauffant
CoarseCoarse
Filter/
Filtre grossier
Filter
Water Level/
Niveau deau :
Fine Filter/
Filtre fin
Spray Arm/
Bras gicleur
Water Level
Niveau deau
Toekick
Attachment
Screws/
Attachment
Screws
Vis de fixation
2. Unclip and disconnect wire harness. Remove 2 screws at the bottom of the door (outside
corners)./Dtacher et dbrancher le faisceau de fils. Enlever 2 vis dans le bas de la porte
(coins extrieurs).
Front Control Models:/Modles contrle frontal : Press and hold on face while pulling tabs
out and up as shown to disengage bottom tabs. Tilt panel to remove from door./Appuyer et
maintenir contre la face tout en poussant les languettes vers lextrieur et vers le haut comme
illustr pour dclencher les languettes infrieures. Incliner le panneau et le retirer de la porte. :
Press and hold on face
Appuyer et maintenir contre la face
31-30642-3 08-12 GE
WARNING:
AVERTISSEMENT :
ADVERTENCIA:
ES NECESARIO DESCONECTAR LA
CORRIENTE ANTES DE REALIZAR
EL SERVICIO TCNICO DEL
ELECTRODOMSTICO.
MAIN BOARD
SR
VS G
W
15
16
J711*
STRIP CIRCUITS
1 2 3 4 5 6 7 8
WR
SX
TR
VY
WS
AB
RB
14
13
12
11
2
10
21
J7
7
6
5
4
3
YW
VW
800 WATTS
18 -WET
-DRY
23.4
BO
J703
1 2 3
TY T
W
J702
1 2
TCO
VX
J702-2
CY
J701
1 2 3
MANUAL RESET
210 +/- 10
WR
HEATING ELEMENT
189 +/- 5
RN
Connecteur
Connecteur
Connecteur DEL
Cavalier
Chauffage/NB personnalit vidange et circ. entretien alimentation CC
YR
DC Power
Connector
SW X
P
Heat/NB
Personality Drain & Circ. Service
Connector Jumper
Connector LED
5x per 3 seconds
6x per 3 seconds
J703-1
TCO
BW
BX
YB
NB
DRAIN PUMP
J703-3
CR
YB
CIRCULATION PUMP
CIRCULATION PUMP
YB
CR
J711-1
BX
189 +/- 5
YB
26 ohms
SX
PIN 1
HEATER
TCO VW
VX
C N
800 WATTS
210 +/- 10 18 -WET
-DRY
23.4
1 2
DETERGENT
WR
PIN 2
WATER
VALVE
J711-2
FLOOD SWITCH
YR
ON
SW
RN
WG
TY
SR
YW
NB
VS
PX
WT
BO
CY
TCO
C
PIN 1
AX
CW
LINE
NEUTRAL
OS
WR
DRAIN PUMP
J711-6
1 2 3 4 5 6 7 8 9 10 11 12 13 14
AB
PIN 5
PIN 3
RB
J711-7
THERMISTER
J101
USER INTERFACE BOARD
WR
J711-3
TR
COLOR CODE
RED & YELLOW
SILVER & RED
SILVER & WHITE
SILVER
TAN & RED
TAN & YELLOW
VIOLET & SILVER
VIOLET & WHITE
VIOLET
VIOLET & YELLOW
WHITE & GREEN
WHITE & RED
WHITE & SILVER
WHITE & TAN
WHITE & VIOLET
WHITE
YELLOW & BLACK
YELLOW & BLUE
YELLOW & RED
YELLOW & WHITE
PIN 2
VY
PIN 3
WS
J711-4
J711-5
DOOR LATCH
1 2 3
1 2 3 4 5 6 7 8
75 F
FLOOD SWITCH
TR
VY
WS
COLOR
RY
SR
SW
SX
TR
TY
VS
VW
VX
VY
WG
WR
WS
WT
WV
WX
YB
YN
YR
YW
PIN 1
DOOR LATCH
VOLTAGE
RESISTANCE
.95
~20.1K
TEMPERATURE F
50
1.56
~10.5K
75
2.25
~5.8K
100
~3.4K
125
OS
SX
LETTERS
RB
COLOR
AB
AX
BG
BO
BW
BX
BY
CO
CP
CR
CW
CY
GX
NB
NX
ON
OS
PX
RB
RN
RX
WR
LETTERS
AB
3x per 3 seconds
4x per 3 seconds
Meaning
Unit is not running a cycle. Select a cycle and press Start.
Unit is in delay start and is waiting to start a cycle. The cycle
will begin once the delay expires.
Unit is in the process of running a cycle.
Unit is paused. Close the door and press the start key to
resume the cycle.
Unit has completed a cycle mode. Clean light on.
Control is in demo mode. Press demo key sequence to exit.
(Hold Start and Heated Dry for appx. 5 sec.)
Communications lost between control boards. Check
connections, replace UI board if necessary.
Software error. Replace machine control board.
AX
Arrt / Notes
Blink Pattern
1x per 3 seconds
2x per 3 seconds
ON
The Service Mode can be entered by pressing and holding the Cycle
Select pad for 5 seconds from the Error Code Display Mode. The
control will blink the Normal LED (Light LED on GDF510P_D0 models)
every few seconds a number of times that corresponds to the load
being tested. To activate the test, press the Start pad. Press the Start
pad to cancel the test, or press the Cycle Select pad to cancel the
current test and proceed to the next test. If the Start light flashes, the
control will begin the test when the door is closed.
Exiting Service Mode:
Press Cycle Select and Start pads together momentarily
To exit the Service Mode from Load Control Mode, press and hold
Cycle Select and Start together momentarily. Both Error and Service
Modes will time-out after appx. 5 minutes.
Diagnosing the Controls:
To validate whether the controls are working properly or not, conduct
the following checks:
clignote- Charge
ment DEL contrler
1
Pompe de
vidange
2) S
ervice LED There is a green LED on the machine control board that indicates the
status of the control board.
Service LED on Machine Control Board
The Service LED on the machine control board provides the status of all control boards in
the system and indicates which mode the dishwasher is running in.
CW
LED
Load To
Timeout / Notes
Blink #
Control
1
Drain Pump Attempts to automatically empty tub. Takes
appx. 75 seconds from normal level.
2
Water
Attempts to automatically fill tub to normal
Valve
volume. Takes appx. 1 minute to the normal
level.
3
Circulation Changes spray arm (via changing diverter)
Pump
every 30 seconds. Runs for maximum of 2
minutes.
Turns heater on for maximum of 2 minutes.
4
Heater
5
Detergent Turns soap dispense solenoid on for
Module
maximum of 2 minutes.
Cause de l'erreur
L'interface utilisateur est incapable de
communiquer avec le contrle de l'appareil.
La temprature minimale de lavage de 120
F n'a pas t atteinte dans 3 des 5 derniers
cycles de lavage.
Le contrle a dtect un court-circuit ou un
circuit ouvert la thermistance.
Le contrle a dtect un court-circuit ou un circuit
ouvert au dtecteur de turbidit. Peut aussi survenir
sur les modles sans dtecteur de turbidit.
S'allume lorsque le Mode d'affichage de
code d'erreur est actif.
Aprs la vrification de la porte, le contrle passe en mode daffichage de
tout code derreur couramment dtecte. Si la DEL au-dessus sallume,
cela indique quune condition derreur existe. Laffichage dune erreur ne
peut pas tre effac manuellement, il le sera automatiquement lorsque la
condition derreur nexistera plus.
Pour quitter le mode daffichage de code derreur, appuyer sur nimporte quelle touche.
Mode Service (Accs en mode erreur seulement) :
Maintenir enfonc la touche Cycle Select durant 5 secondes.
Appuyer sur :
Cycle Select = Slectionne/incrmente le test
Start = Dmarre/arrte le test
1) V
oltage Check The on-board power supply of the machine control outputs 12-15VDC,
and 4.25-5.25VDC.
After door check, control will enter mode to display any error codes
currently detected by the control. If above LED illuminates, it indicates
error condition is present. Error displays cannot be cleared manually. They
will be automatically cleared when error condition is no longer present.
To exit the Error Code Display Mode, press any key.
Service Mode (can only be entered during Error Mode):
Press and hold the Cycle Select pad for 5 seconds.
Press: Cycle Select = Selects/Increments Test
Start = Starts/Stops Test
DEL
Type d'erreur
Start
Dfaut de
communication
Heated Erreur de
Dry
temprature de
lavage
Wash Erreur de
Boost thermistance
Clean Erreur de
dtecteur de
turbidit
Lock
Toujours allum
BW
YB
CR
DEL allumes
Le contrle dtecte que la porte est ferme
DEL clignotantes
Le contrle dtecte que la porte est ouverte
Lors de lentre en mode Erreur, le contrle affiche ltat de la
porte pendant 10 secondes. Si les DEL sont allumes, la porte est
considre ferme et si les DEL clignotent, elle est considre ouverte.
Mode daffichage de code derreur :
cycles), maintenez enfonces les touches Cycle Select et Start simultanment pendant 5 secondes.
Vrification de ltat de la porte :
VX
LEDs Solid
Control is interpreting door as closed
LEDs Flashing
Control is interpreting door as open
On entry into the Error Mode, the control reports the door status for
10 seconds. If the LEDs are solidly illuminated, the door is detected as
closed and if the LEDs are flashing, the door is detected as open.
Error Code Display Mode:
LED
Error Type
Error Causes
Start
Communications User Interface control unable to
Failure
communicate with machine control.
Heated Wash
Minimum wash temperature of 120F
Dry
Temperature
was not reached in 3 of the past 5 wash
Error
cycles.
Wash
Thermistor Error Control detecting short or open circuit
Boost
at thermistor.
Clean
Turbidity Sensor Control detecting short or open circuit
Error
at turbidity sensor. May also occur on
models without turbidity sensor.
Lock
Always
Illuminates when Error Code Display
Illuminated
Mode is active.
and hold the Cycle Select and Start pads simultaneously for 5 seconds.
Door Status Check:
WR
MODE ERREUR
Lorsque
le lave-vaisselle est en mode Standy (Modle slection de
BX
WX
GX
ERROR Mode
When
the dishwasher is in Standby Mode (Cycle Selection Mode), press
2.91
1 2
3.48
~2.1K
150
3.91
~1.3K
175
WATER VALVE
165D9739P004
31-30642-3 08-12 GE