Disclaimer: The Cisco Power Calculator is intended to be an educational resource and a starting point in
planning your power requirement; it is not a final recommendation from Cisco. This tool does not check for software
compatibility. To determine the power requirements and software most appropriate for your company we suggest you work
with a Cisco representative, Cisco channel partner or a solutions provider.
Line Card
WS-X45-SUP8-E
Optional Uplink
Module
--
1
2
WS-X4712-SFP+E
--
--
WS-X4748-UPOE+E
--
IEEE PoE
WS-X4748-UPOE+E
--
IEEE PoE
WS-X4748-UPOE+E
--
IEEE PoE
--
IEEE PoE
Percentage Of Power Used
WS-X4748-UPOE+E
Minimum Power Supply
Combined PWR-C45-4200W with dual 220V inputs on each power supply. (Up to
5,500Watts protected. See FAQ)
--
Data:44.79%
PoE:57.32%
Quick Facts
Selected Supervisor Engine
Selected Chassis
Selected Voltage
Chassis Slots
Power Supply Options
WS-X45-SUP8-E
WS-C4506-E
200-240 Volts AC
6
Combined PWR-C45-4200W with
dual 220V inputs on each power
supply. (Up to 5,500Watts
protected. See FAQ)
Single/Redundant PWR-C456000W with a Dual 220V input
Combined PWR-C45-6000W with
Single 220V inputs on each power
supply
Combined PWR-C45-6000W with
Dual 220V inputs on each power
supply
Combined PWR-C45-9000W with
Triple 220V inputs on each power
supply
Single/Redundant PWR-C459000W with a Triple 220V input
Combined PWR-C45-9000W with
Single 220V inputs on each power
supply
Combined PWR-C45-9000W with
Dual 220V inputs on each power
supply
Combined PWR-C45-9000W with
Five 220V inputs
PWR-C45-1400DC-P
Single/Redundant PWR-C459000W with a Dual 220V input
4
10
NOTE :
PWR-C45-1400DC-P supply should be used in conjunction with an AC powered DC UPS . For more information, click <a href=
"javascript:openLargePopup('help.jsp#q')">Tutorial/Q&A</a>
Percentage of
Power used
Total Output
Current for this
PSU(A)
Total Output
Current Used (A)
Total Output
Current Remaining
(A)
Data:44.79%
Data:1214.68
Data:183.33
Data:82.11
Data:101.22
PoE:2646.29
PoE:119.23
PoE:68.34
PoE:50.89
PoE:57.32%
Other Power Supply Options
Percentage of
Power used
Total Output
Current for This
PSU(A)
Total Output
Current Used (A)
Total Output
Current Remaining
(A)
Data:44.79%
Data:1214.68
Data:183.33
Data:82.11
Data:101.22
PoE:1246.29
PoE:92.31
PoE:68.34
PoE:23.97
Data:3014.68
Data:333.33
Data:82.11
Data:251.22
PoE:806.29
PoE:83.85
PoE:68.34
PoE:15.51
Data:3014.68
Data:333.33
Data:82.11
Data:251.22
PoE:5146.29
PoE:167.31
PoE:68.34
PoE:98.97
Data:2776.68
Data:313.50
Data:82.11
Data:231.39
PoE:10846.29
PoE:276.92
PoE:68.34
PoE:208.58
Data:974.68
Data:163.33
Data:82.11
Data:81.22
PoE:3946.29
PoE:144.23
PoE:68.34
PoE:75.89
PoE:74.04%
Combined PWR-C45-6000W with Single
220V inputs on each power supply
Data:24.63%
PoE:81.51%
Data:24.63%
PoE:40.85%
Data:26.19%
PoE:24.68%
Data:50.27%
PoE:47.38%
Data:37.49%
Data:1642.68
Data:219.00
Data:82.11
Data:136.89
PoE:596.29
PoE:79.81
PoE:68.34
PoE:11.47
Data:2776.68
Data:313.50
Data:82.11
Data:231.39
PoE:4746.29
PoE:159.62
PoE:68.34
PoE:91.27
Data:1954.68
Data:245.00
Data:82.11
Data:162.89
PoE:7696.29
PoE:216.35
PoE:68.34
PoE:148.01
Data:374.68
Data:113.33
Data:82.11
Data:31.22
PoE:3666.29
PoE:138.85
PoE:68.34
PoE:70.51
Data:974.68
Data:163.33
Data:82.11
Data:81.22
PoE:1446.29
PoE:96.15
PoE:68.34
PoE:27.81
PoE:85.63%
Combined PWR-C45-9000W with Dual
220V inputs on each power supply
Data:26.19%
PoE:42.82%
Data:33.51%
PoE:31.59%
PWR-C45-1400DC-P
Data:72.45%
PoE:49.22%
Data:50.27%
PoE:71.07%
Configuration Details
Slot
Line Card
Heat Dissipation
(BTU/Hr)
482.12
Chassis
WS-C4506-E
10.00
WS-X45-SUP8-E
33.33
399.96
319.97
1606.90
WS-X4712-SFP+E
7.50
90.00
72.00
361.59
WS-X4748-UPOE+E
7.82
93.84
75.07
377.02
WS-X4748-UPOE+E
7.82
93.84
75.07
377.02
WS-X4748-UPOE+E
7.82
93.84
75.07
377.02
WS-X4748-UPOE+E
7.82
93.84
75.07
377.02
PoE Device
Sub Total
Quantity
82.11
Output Current (A)
985.32
Output Power (W)
CP-7971G (14.9W)
172
55.38
2879.55
788.26
Typical Power Used
(W)
2303.64
3958.67
Heat Dissipation
(BTU/Hr)
2319.46
20
12.96
674.16
539.33
543.03
Sub Total
68.34
Output Current (A)
3553.71
Output Power (W)
Total
150.45
4539.03
2842.97
Typical Power Used
(W)
3631.22
2862.49
Heat Dissipation
(BTU/Hr)
6821.16
NOTE :
Output Power is the amount of power delivered from the Power Supply to the Catalyst 4500-E. To figure Input Power, divide output power by .85
(typical efficiency of the power supplies).
NOTE :
Output Power and Heat Dissipation numbers computed by the Cisco Power Calculator are maximum values and can be used for facility power and
cooling capacity planning. These figures are not indicative of the actual power draw or heat dissipation. Typical power draw is about 20% lower than
the maximum value shown. Also note that most of power allocated for PoE devices is dissipated at the end points.