M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P400
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P400

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
280/350
320/400
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

505.1

Dimension(L*W*H) (mm)
3300X1140X1956
Weight(kg)
3300
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

2306C-E14TAG2 (UK Perkins)


Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

353
Turbocharged
137X165
201in full load
14.6
438
32.2
79.1
461
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

68
47

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

92dBA(open)

ALTERNATOR
ALTERNATOR MODEL

LSA 47.2VS2(Leroy Somer)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P450
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P450

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
320/400
360/450
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

577.4

Dimension(L*W*H) (mm)
3300X1140X1956
Weight(kg)
3300
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

2306C-E14TAG3 (UK Perkins)


Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

396
Turbocharged
137X165
199in full load
14.6
438
34.6
86.6
474
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

68
47

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

92dBA(open)

ALTERNATOR
ALTERNATOR MODEL

LSA 47.2S4(Leroy Somer)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P500
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P500

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
360/450
400/500
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

649.5

Dimension(L*W*H) (mm)
3430X1167X1956
Weight(kg)
3800
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

2806C-E16TAG1 ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

445
Turbocharged
140X171
205 (in full Load)
15.8
540
38
83
457
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

68
50

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

95dBA

ALTERNATOR
ALTERNATOR MODEL

LSA 47.2S5(Leroy Somer)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P550
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P550

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
400/500
440/550
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

721.7

Dimension(L*W*H) (mm)
3500X1167X1956
Weight(kg)
3940
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

2806C-E16TAG2 ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

483
Turbocharged
140X171
203 (in full Load)
15.8
540
41.3
90
459
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

68
50

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

95dBA

ALTERNATOR
ALTERNATOR MODEL

LSA 47.2M7(Leroy Somer)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P625
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P625

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
440/550
500/625
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

793.9

Dimension(L*W*H) (mm)
3245X1460X2197
Weight(kg)
3940
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

2806C-E18TAG1 ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

561
Turbocharged
145X183
217.7 (in full Load)
18.1
702
45
129
570
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

55.5
61

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

95dBA

ALTERNATOR
ALTERNATOR MODEL

LSA 47.2M8(Leroy Somer)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P690
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P690

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
500/625
550/690
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

902.1

Dimension(L*W*H) (mm)
3245X1460X2197
Weight(kg)
4706
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

2806C-E18TAG2( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

607
Turbocharged
145X183
202.4 (in full Load)
18.1
702
43
123
563
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

55.5
61

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

95dBA

ALTERNATOR
ALTERNATOR MODEL

LSA 47.2L9(Leroy Somer)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P725
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P725

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
520/650
580/725
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

938.2

Dimension(L*W*H) (mm)
4140*1700*2150
Weight(kg)
4706
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

4006-23TAG1A ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

646
Turbocharged
160X190
203 (in full load)
22.92
1200
64
171
410
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

113.4
105

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

95dBA(open)

ALTERNATOR
ALTERNATOR MODEL

LSA 49.1S4 (Leroy Somer)

Excitation

Brushless

Insulation class

Protection class

IP23

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P800
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P800

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
580/725
640/800
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

1046.5

Dimension(L*W*H) (mm)
4200*1700*2150
Weight(kg)
4706
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

4006-23TAG2A ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

711
Turbocharged
160X190
203 (in full load)
22.92
1200
71
180
430
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

113.4
105

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

95dBA(open)

ALTERNATOR
ALTERNATOR MODEL

LSA 49.1M6 (Leroy Somer)

Excitation

Brushless

Insulation class

Protection class

IP23

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P900
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P900

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
640/800
720/900
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

1154.7

Dimension(L*W*H) (mm)
4200*1700*2150
Weight(kg)
4706
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

4006-23TAG3A ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

786
Turbocharged
160X190
203 (in full load)
22.92
1200
73
193
500
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

113.4
105

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

95dBA(open)

ALTERNATOR
ALTERNATOR MODEL

LSA 49.1M75 (Leroy Somer)

Excitation

Brushless

Insulation class

Protection class

IP23

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1100
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P1100

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
800/1023
880/1100
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

1476.6

Dimension(L*W*H) (mm)
4750*1870*2360
Weight(kg)
7611
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

4008-TAG2A ( UK Perkins)
Water-cooled, 8 cylinders in line, 4-cycle, direct injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

985
Turbocharged
160X190
214 (in full load)
30.56
1110
80.5
200
465
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

149
153

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

102dBA(open)

ALTERNATOR
ALTERNATOR MODEL

LSG55(Leroy Somer)

Excitation

Brushless

Insulation class

Protection class

IP23

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1375
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P1375

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
1000/1250
1100/1375
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

1804.3

Dimension(L*W*H) (mm)
4800*1870*2570
Weight(kg)
9154
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

4012TWG2( UK Perkins)
Water-cooled, 12 cylinders V-line, 4-cycle, direct
injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Engine coolant flow l/s
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

1207
Turbocharged
160X190
207 (in full load)
45.84
15.7
97
245
460
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

205
159

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

102dBA(open)

ALTERNATOR
ALTERNATOR MODEL

LVI634G(Stamford)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1550
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P1550

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
1100/1375
1240/1550
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

1984.7

Dimension(L*W*H) (mm)
5600*2250*2570
Weight(kg)
11580
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

4012TAG1A( UK Perkins)
Water-cooled, 12 cylinders V-line, 4-cycle, direct
injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Engine coolant flow(l/s)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

1292
Turbocharged
160X190
203 (in full load)
45.84
17
108
270
490
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

159
235

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

102dBA(open)

ALTERNATOR
ALTERNATOR MODEL

PI734B(Stamford)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1650
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P1650

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
1200/1500
1320/1650
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

2165.1

Dimension(L*W*H) (mm)
5927*2300*3010
Weight(kg)
15430
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

4012TAG2A( UK Perkins)
Water-cooled, 12 cylinders V-line, 4-cycle, direct
injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Engine coolant flow(l/s)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

1386
Turbocharged
160X190
206 (in full load)
45.84
17
110
290
510
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

159
235

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

102dBA(open)

ALTERNATOR
ALTERNATOR MODEL

PI734C(Stamford)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1850
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P1850

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
1320/1650
1452/1815
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

2381.6

Dimension(L*W*H) (mm)
5927*2300*3010
Weight(kg)
15430
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

4016TAG ( UK Perkins)
Water-cooled, 16 cylinders V-line, 4-cycle, direct
injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

1649
Turbocharged
160X190
206 (in full load)
61.12
1916
146
379
480
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

215
300

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

102dBA(open)

ALTERNATOR
ALTERNATOR MODEL

PI734D(Stamford)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P2250
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS.

M-P2250

Rated speed / frequency


Continuous outputKW/KVA
Standby outputKW/KVA
Voltage, Phase and wire

1500 rpm / 50 Hz
1640/2050
1800/2250
400V/230V, 3 Phase and 4 Wires

Rated power factor

0.8lagging

Maximum output current(A)

2959

Dimension(L*W*H) (mm)
6011*2280*3010
Weight(kg)
15500
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.

Diesel Engine
DIESEL ENGINE MODEL
Engine Characters

4016TAG2A( UK Perkins)
Water-cooled, 16 cylinders V-line, 4-cycle, direct
injection

The maximum outputkW


Aspiration
Bore(mm)Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Engine coolant flow(l/s)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature

1890
Turbocharged
160X190
212(in full load)
61.1
19
145
393
493
1

M SERIES PERKINS DIESEL GENERATING SETS


Lub-oil pan capacity(L)
Cooling water capacity(L)

214
316

Voltage for start(V)

24

Instrument for adjusting speed

Electronically

Noise level(@7M)

102dBA(open)

ALTERNATOR
ALTERNATOR MODEL

PI734F(Stamford)

Excitation

Brushless

Insulation class

Protection class

IP22

Efficiency

91.5%

Steady state voltage regulation

0.5%

Voltage Control

AVR

Generating Set Control System


AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

Anda mungkin juga menyukai