TRuepoint
a new generation
of point-to-point
PDH / SDH / Ethernet
digital radios
Ease of Use
Installation
The Signal Processing Unit occupies a single rackmounting space for 1+0 configurations; two rack
mounting spaces for 1+1 and 2+0 configurations.
The Radio Frequency Unit is weatherproof for
outdoor installation, but it can also be mounted
indoors on a radio relay rack.
The RFU can be attached directly to the antenna
(RFU-detachable configuration).
Management and Maintenance
No downtime during module swaps in 1+1
configurations.
The controller board can be removed without
interrupting traffic.
Backwards-compatible with Harris MicroStar radios
through an integrated HDLC port.
Intuitive LED displays on each unit indicate activity
and alarm status.
Built-in self diagnostics differentiate path alarms
from equipment alarms.
Convenient setup, monitoring and configuration of
any radio in the network through a graphical web
CIT, VT-100 computer terminal or hand-held keypad
(provided by Harris).
A removable MMC in the controller board stores
software and configuration settings, which allows for
autoconfiguration.
Scalable
The scalable, RF-independent Signal Processing
Unit uses optional plug-in modules to accommodate
a wide variety of data interfaces for PDH, SDH and
IP applications.
The Radio Frequency Unit is capacity-independent.
Single module swap for capacity upgrade from 2 E1
to STM-1.
The indoor configuration of the Radio Frequency/
Signal Processing Unit (TRuepoint 5300)
accommodates high power amplifiers.
Flexible
Software-selectable modulation (4, 16, 32, 64, 128,
256 QAM).
Flexible forward error correction schemes optimize
bandwidth and system gain.
Plug-and-play modules facilitate faster network
startup, simple reconfigurations and capacity
upgrades.
Reliable
A common platform and integrated design for all
configurations provides more than 20 years MTBF.
Automatic transmitter power control (ATPC).
Reverse channel switching protects against silent
transmitter failures.
TRuepoint
2 STM-1
ADM
TRuepoint
SDH RING
2+0
(dual frequency)
TRuepoint
2 STM-1
TRuepoint
TRuepoint
TRuepoint
ADM
TRuepoint
Core
Network
STM-1
(3 VC3) TRuepoint
TRuepoint
STM-1
(VC3-1)
ADM
1 E1
TRuepoint
TRuepoint
21 E1
TRuepoint
21 E1/SDH-STM0
TRuepoint
1 E1
TRuepoint
TRuepoint
STM-1
(1 VC3)
ADM
21 E1
Core
Network
ADM
TRuepoint
TRuepoint
ADM
TRuepoint
STM-1
(VC3-3)
Multiplexing section
K1, K2
TRuepoint
The 21 E1 Mux is mapped into either a STM0 or a partially filled STM-1 and the Mux board
behaves with the ADM to which it is connected as a multiplexing section.
2 x 100BASE-T / STM-1
2 x 100BASE-T
2 x 100BASE-T
E1
PABX
TRuepoint
TRuepoint
STM-1
(3 VC3)
ADM/
Router
Multiplexing section
K1, K2
Core
Network
ADM/
Router
STM-1
(3 VC3)
LAN
TRuepoint
Multiplexing section
K1, K2
TRuepoint
1 E1
TRuepoint
21 E1
E1
PABX
TRuepoint
21 E1
21 E1
Multiplexing section
K1, K2
LAN
1 E1
STM-1
(VC3-2)
1 E1
STM-1
(1 VC3)
RFU Configurations
TRuepoint
(6 - 11 GHz)
Unprotected (1+0)
Unprotected
Terminal
Integrated
Flat Antenna
Integrated
Flat Antenna
Separate
Parabolic Antenna
Separate
Parabolic Antenna
Repeater
Separate Antenna
RFU
Protected
Terminal
Protected
Protected
RFU
Unprotected
Protected
Repeater
STM-1 + 1E1
Modulation
Lower Upper
10.5
11
13
14
States
6 GHz 6 GHz
GHz
GHz
GHz
GHz
GHz
GHz
15
18
23
26
28
32
38
GHz
GHz
GHz
GHz
GHz
GHz
GHz
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
16
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
14
14
14
14
14
13.75
14
14
14
14
14
16
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
28
28
28
28
28
28
27.5
28
28
28
28
16
14
14
14
14
14
13.75
14
14
14
14
14
28
28
28
28
28
27.5
28
28
28
28
28
16
14
14
14
14
14
13.75
14
14
14
14
14
40
56
55
56
56
56
56
56
16
29.65
20
28
28
28
20
28
28
28
28
28
28
28
28
32
14
14
14
14
14
13.75
14
14
14
14
14
32
56
55
56
56
56
56
56
64
40
40
128
29.65
30
28
28
28
28
28
27.5
28
28
28
28
28
STM-1 + 1E1
Modulation
Lower Upper
10.5
11
13
14
15
18
23
26
28
32
38
States
6 GHz 6 GHz
GHz
GHz
GHz
GHz
GHz
GHz
GHz
GHz
GHz
GHz
GHz
GHz
GHz
-94.0
-94.0
-94.0
-92.0
-92.0
-92.0
-92.0
-92.0
-92.0
-92.0
-91.5
-91.0
-91.0
-91.0
-89.0
-89.0
-89.0
-84.5
-84.5
-89.0
-89.0
-89.0
16
-87.0
-87.0
-87.0
-85.5
-85.5
-85.5
-85.5
-85.5
-85.5
-85.5
-85.0
-88.0
-88.0
-88.0
-86.5
-86.5
-86.5
-86.5
-86.5
-86.5
-86.5
-86.0
16
-84.5
-84.5
-84.5
-82.5
-82.5
-82.5
-82.5
-82.5
-82.5
-82.5
-82.0
-85.5
-85.5
-85.5
-83.5
-83.5
-83.5
-83.5
-83.5
-83.5
-83.5
-83.0
16
-81.5
-81.5
-81.5
-79.5
-79.5
-79.5
-79.5
-79.5
-79.5
-79.5
-79.0
-85.0
-85.0
-85.0
-83.0
-83.0
-83.0
-83.0
-83.0
-83.0
-83.0
-82.5
16
-81.0
-81.0
-81.0
-79.0
-79.0
-79.0
-79.0
-78.0
-79.0
-79.0
-76.5
-83.5
-81.5
-81.5
-81.5
-81.5
-81.5
-81.5
-81.0
16
-79.5
-79.5
-79.5
-79.5
-79.5
-79.5
-77.5
-77.5
-77.5
-77.5
-77.5
-77.5
-77.5
-77.0
32
-77.5
-77.5
-77.5
-77.5
-75.5
-75.5
-75.5
-75.5
-75.5
-75.5
-75.5
-75.0
32
-75.0
-75.0
-75.0
-75.0
-75.0
-75.0
-74.5
-67.5
-67.5
-67.5
-67.5
-67.5
-67.0
64
-74.5
-74.5
-74.5
128
-70.0
-70.0
-69.0
-69.0
-69.0
-67.5
-67.5
STM-1 + 1E1
Modulation
Lower Upper
10.5
11
13
14
States
6 GHz 6 GHz
GHz
GHz
GHz
GHz
GHz
GHz
15
18
23
26
28
32
38
GHz
GHz
GHz
GHz
GHz
GHz
GHz
30.5
30.5
28.5
26
26
26
25
24
24
20
24
30.5
30.5
28.5
26
26
26
25
24
24
20
24
16
26.5
26.5
24.5
23
23
23
22
21
21
17
21
30.5
30.5
28.5
26
26
26
25
23
24
20
24
16
26.5
26.5
24.5
23
23
23
22
20
21
17
21
30.5
30.5
28.5
26
26
26
25
23
24
20
24
16
26.5
26.5
24.5
23
23
23
22
20
21
17
21
30.5
30.5
28.5
26
26
26
25
23
24
20
24
16
26.5
26.5
24.5
23
23
23
22
20
21
17
21
28.5
26
26
25
24
24
20
24
16
27.5
27.5
26.5
26.5
24.5
24.5
23
23
23
22
21
21
17
21
32
26.5
26.5
25.5
25.5
23.5
22
22
22
21
20
20
16
20
20
32
22
22
21
20
20
16
64
25
25
22
128
24
24
23
23
21
20
20
20
18
17
17
13
17
* Available on request
- Not available
**Nominal power for outdoor systems from 6-11 GHz and 23-38 GHz, tolerance is + 2dB. Nominal power for 13-18 GHz
outdoor systems, tolerance is +2/-1 dB. Nominal power for indoor systems, tolerance is +1 dB.
TRuepoint 5100
System Characteristics
Band
Frequency Range
Channel Spacing
LL6 GHz
L6 GHz
U6 GHz
7 GHz
8 GHz
10 GHz
11 GHz
13 GHz
14 GHz
15 GHz
18 GHz
23 GHz
26 GHz
28 GHz
31 GHz
32 GHz
38 GHz
39 GHz
266 MHz
240, 252.04 MHz
340, 345 (China) MHz
151.614, 154, 160, 161, 182, 196, 245 MHz
119, 126, 208, 213.5, 266, 310, 311.32 MHz
65, 84 (France), 91 (Argentina)
490, 530 MHz
266 MHz
Contact Harris
315, 322, 420, 490, 640, 644, 728, MHz
120, 340, 1008, 1010, 1092.5, 1120, 1560, 1615 MHz
252 (France), 1008, 1232, MHz
1008 MHz
1008 MHz
140 MHz
812 MHz
700 (Argentina), 980, 1260, MHz
462, 980 MHz
28 MHz
28 (Bosnia), 29.65, 40 MHz
20, 40 MHz
3.5, 7, 14, 28 MHz
7, 14, 28, 29.65 MHz
3.5, 7, 14, 28 MHz
20 (China), 40 MHz
3.5, 7, 14, 28 MHz
Contact Harris
3.5, 7, 14, 28, 56 MHz
3.5, 7, 13.75, 27.5, 55 MHz
3.5, 5 (Brazil), 7, 14, 28, 56 MHz
3.5, 7, 14, 28, 56 MHz
3, 5, 7, 14, 28, 56 MHz
3.5, 7, 14, 28 MHz
3.5, 7, 14, 28, 56 MHz
3.5, 7, 14, 28, 56 MHz
3.5, 7, 14, 28, 56 MHz
PDR 70
PDR 70
PDR 70
PDR 84
PDR 84
PDR 100
PDR 100
PBR 120
PBR 140
PBR 140
PBR 220
PBR 220
PBR 220
PBR 320
PBR 320
PBR 320
PBR 320
PBR 320
CPR 137G
CPR 137G
CPR 137G
CPR 112G
CPR 112G
CPR 90G
CPR 90G
UG Choke
UG 541A/U
UG 541A/U
UG 596A/U
UG 596A/U
UG 596A/U
UG 600A/U
UG 600A/U
UG 600A/U
UG 600A/U
UG 600A/U
WR 137
WR 137
WR 137
WR 112
WR 112
WR 90
WR 90
WR 75
WR 62
WR 62
WR 42
WR 42
WR 42
WR 28
WR 28
WR 28
WR 28
WR 28
(1)
On request, TruePoint 5200 in the 13 to 23 GHz frequency band can be provided. Antenna flanges are CBR or equivalent US Mil. Flanges to be specified at the time
of ordering.
(2)
The radio flanges have threaded holes to mate with the waveguide or flextwist flange through-holes.
(3)
The TRuepoint 5300 can accommodate an optional HPA.
Auxiliary Channels:
Standard: Service Channel 1; 19.2 kbps asynchronous (RS-232)
Optional: Service Channels 2 and 3
Orderwire or Data Channel 64 kbps synchronous co-contra
directional V.11 or G.703
Configurations:
TRuepoint 5300 & 5200
TRuepoint 5100
Network Management:
FarScanTM, StarView, NetBossTM, SNMP Manager
Radio Control Monitoring Tools:
Web CIT, VT-100, Harris Handheld Terminal, NMS
Alarms: Programmable relay alarms, 4 basic relays, 2 input (controller)
Optional: 12 relays/12 inputs or 6 relays/30 inputs or a
combination using two Relay & Alarm modules
Operating Temperature Range:
Guaranteed Performance:
Operational:
Humidity: 95% max
Indoor
Outdoor
0 to +50 C
-33 to +55 C
-10 to +55 C -40 to +55 C
detection)
Power Consumption: (SPU+RFU for high capacity)
Non-Protected
Protected
TRuepoint 5100
70 Watts
140 Watts
TRuepoint 5200
80 Watts
160 Watts
TRuepoint 5300*
91 Watts
182 Watts
* Without HPA
Regulatory Information
Frequency Plans:
recommendation
Digital Interface:
Electromagnetic Compatibility:
EN 301 489-4, EN 301 489-1
Standard: Complies with the latest ETSI and R&TTE directive and
future European Harmonized EN 302 317-2-2 Class 2 type equipment
operating in non-harmonized frequency bands.
Mechanical Characteristics
Connections: SPU
Dimensions:
SPU 1+0
SPU 1+1
TRuepoint 5100
TRuepoint 5200
TRuepoint 5300
connectors
Weight
3.3 kg.
5.2 kg.
6.1 kg.
18 kg.
51 kg.
Antenna Characteristics
Integrated Flat Antenna: (using unique Harris Flat antenna)
23/26 GHz 16.5" (419 mm) 35 dBi
38 GHz
12.0" (305 mm) 38 dBi
Detachable RFU With Parabolic Antenna:
Parabolic high-performance antenna from 1 ft. to 4 ft.
(30cm to 1.2m) depending on frequency band. Complies with EN
302 317-4-2. (Uses a direct slip fit with latches for connecting to the
antenna.)
Separate Antenna:
Off-the-shelf parabolic antenna from any vendor. (Uses waveguide
or flex twist to interconnect radio and antenna. Radio flange
interfaces are specified in the table above.)
Unless otherwise indicated, nominal performance specifications are listed and apply to transmitters/receivers connected back-to-back
and must be confirmed before they become applicable to any specific system, contract or order.
Microwave Communications Division | 3 Htel de Ville | 3 Htel de Ville | Montral, Qubc, Canada H9B 3G4
Phone 1-800-4-HARRIS ext. 3209 (within North America)
1-407-727-9207 ext.3209 (outside North America)
www.harris.com
Copyright 2003 Harris Corporation