Table of Contents
Overview .................................................................................................................... 3
Version ....................................................................................................................... 3
Demo configurations .................................................................................................. 4
Pre-requisites ............................................................................................................. 6
Support....................................................................................................................... 6
Uninstalling the Demo Database Package v1.2.01 .................................................... 7
Software installation ................................................................................................. 12
1.
2.
3.
4.
5.
6.
7.
8.
Page 2 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Overview
This document is intended to help you successfully install the Demo Database compatible with
StruxureWare Building Operation v1.3.0.938. This installation guide covers software installation
(including possible trouble-shooting steps) and the Demo Database installation.
The documentation is detailed (including screenshots) to clearly help you through each step.
Follow each step exactly to ensure successful installation. There may be minor variances based
on demo machine operating systems.
This Demo Database Package is designed to help you:
use it as a basis to add more functionality for your own unique version of the demo
Documentation:
o Installation Guide (this document): detailed instructions on how to install the Demo
Database
o Feature Overview Guide: summary of navigation and functionality that has been
designed in the Demo Database
o Demo Presentation Guide: outline of proposed demo flow (i.e. order in which to step
through the demo), including presenter actions and sample script
The Demo Database Package is a marketing and sales tool and is not a substitute for training and
product knowledge certification. Using this demo requires you have an understanding of
StruxureWare Building Operation and can navigate through common features and procedures.
The Demo Database can be used in conjunction with an Automation Server Hardware Kit. The
Hardware Kit can be ordered separately and includes an Automation Server, power supply, and three
I/O modules (pre-wired to lights, potentiometers, switches, and thermistors).
Automation Server Kit part number: SXWKITASX10001
Version
The version number associated with this Demo Database Package (v1.3.01) is the version of the
demo package itself. It is compatible with StruxureWare Building Operation v1.3.
This Demo Database Package (v1.3.01) is an updated version of the v1.2.01 package with some
additional features. Some of feature descriptions and screenshots in the documentation may be from
v1.2.01 but are still functionally applicable for v1.3.01.
Because the database is installed using the restore process, the software must be the same exact
version as used for the demo database backup files specifically v1.3.0.938.
Page 3 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Demo configurations
The demo works in multiple ways:
1. a software-only standalone version with just the Enterprise Server installed locally on the
demo machine (no hardware)
Conceptual representation:
* Enterprise Server (software
only) is actually installed on
same machine as the user
interface
User Interface:
WorkStation
WebStation
Presenters
demo machine
Connect to the Enterprise Server and use the demo showing the relationship between
the Enterprise Server and the Automation Server
Conceptual representation:
Connects to Enterprise Server
(can see the Automation Server)
User Interface:
WorkStation
WebStation
Presenters
demo machine
Automation Server
Hardware Kit
3. a standalone Automation Server Hardware Kit version i.e. connect directly to the
Automation Server (bypassing connecting to the Enterprise Server)
Note: The Automation Server is not populated with all of the features available in the
Enterprise Server portion of the demo.
Conceptual representation:
Connects directly to Automation Server
User Interface:
WorkStation
WebStation
Automation Server
Hardware Kit
Presenters
demo machine
Page 4 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
The columns below summarize the installation steps (in this document) required for the different demo
configurations. The software-only standalone version is a shorter and simpler process.
Automation Server
Hardware Kit
Software installation
1. Pre-requisite: Microsoft .NET Framework 4
2. Install License Administrator
3. Install Demo/Training License
4. Install Enterprise Server
5. Install Device Administrator
6. Install WorkStation
7. Create software shortcuts
8. Test successful software and Enterprise
Server installation
Demo Database installation
13. Demo machine IP address (for software
only configuration)
15. Restore backup file in the Enterprise
Server
Delete unused Automation Server
17. Delete unused Automation Server from
the Enterprise Server
Set Time Zone and local time
18. Set Time Zone in the Enterprise Server
Software installation
1. Pre-requisite: Microsoft .NET Framework 4
2. Install License Administrator
3. Install Demo/Training License
4. Install Enterprise Server
5. Install Device Administrator
6. Install WorkStation
7. Create software shortcuts
8. Test successful software and Enterprise Server
installation
Test Demo set up and communication
9. Automation Server Hardware Kit version
10. Automation Server Hardware Kit IP address
11. Demo machine IP address (for demo configurations
using a Hardware Kit)
12. Verify communication between demo machine and
Automation Server
Demo Database installation
14. Restore backup file in the Automation Server
15. Restore backup file in the Enterprise Server
Change IP address(es) after database restore
16. Update IP addresses stored in the Enterprise Server
database
Set Time Zone and local time
18. Set Time Zone in the Enterprise Server
19. Set Time Zone and local time in the Automation
Server
Test successful Demo Database installation
20. Test Enterprise Server restore
21. Test Automation Server Hardware Kit
Page 5 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Pre-requisites
The following are the pre-requisites for installing and using the Demo Database:
Presenters must have attended StruxureWare Building Operation sales and/or technical
training and must be certified.
o
The software requires a license to run. StruxureWare Building Operation training certified
personnel can get a temporary (time-based) license from their regional training department for
demo use.
Demo machine must meet the hardware and software requirements (and configuration) to
support StruxureWare Building Operation v1.3.
o
o
Must have an understanding of StruxureWare Building Operation and can navigate through
common features and procedures.
See the StruxureWare Building Operation v1.3 Product Announcement, Release Notes,
datasheets and/or technical documentation for more detailed information.
Machine user account used for installation must meet requirements for installation e.g. must
be an administrator to the machine to install/uninstall software.
If using the Demo Database, the user must be willing to clear existing database contents.
Since the demo is installed using the restore process, it will overwrite existing contents.
o
o
Users can add content to the Demo Database after the database is installed.
If already using the global Demo Database Package v1.2.01, first uninstall StruxureWare
Building Operation v1.2.0.767 before installing the global Demo Database Package v1.3.01.
Refer to the Uninstalling the Demo Database Package v1.2.01 section on the next
page.
Users must know how to set the IP address of the demo machine and how to test
communication between IP devices (i.e. between the demo machine and Automation Server);
procedures differ per operating system.
If using an Automation Server Hardware Kit, have it available and ready for this process.
o
The Automation Server must be at version 1.3.0.938 to install the Demo Database.
If not already at version 1.3, use the Device Administrator to upgrade.
Use the Device Administrator to install a New database in the Automation Server i.e.
clear the existing contents.
Users must have a USB 2.0 type A/B Male to Male (maximum length 3 m) cable (used to
connect the USB device port on the Automation Server to the USB port on the demo machine).
This cable is commonly found and can be bought outside of Schneider Electric.
Users must have a network cable to connect the Automation Server to the demo machine.
Support
The Demo Database package is a sales and marketing tool for your use as is. It is not a product
supported through Product Support Services (PSS).
If you have product specific technical issues such as installing the software applications (e.g. License
Administrator, Enterprise Server) PSS may be able to help. However, PSS does not support the Demo
Database contents or features. The Demo Database can be re-installed to return to its original state.
Attending and participating in Product Training classes will help you become familiar with
StruxureWare Building Operation and how to get around a populated system. Refer to the other Demo
Database Package documentation (i.e. Feature Overview Guide, Demo Presentation Guide) for details
on how to use the demo. Or, leverage the StruxureWare Building Operation online community site to
gain advice from others and share your demo experiences. Note: Community site availability and
access varies per geographic region.
Page 6 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
proceed with the Demo Database v1.3.01 installation and lose your changes
export your changes and re-import them after the Demo Database v1.3.01 is
successfully installed
upgrade your existing database to StruxureWare Building Operation v1.3 and not use
the Demo Database v1.3.01
o This document does not cover upgrading existing databases
Page 7 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step D: When this dialog opens, scroll down and select StruxureWare 1.2 Enterprise Server.
Page 8 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step F: You may see the following dialog box appear as the Enterprise Server service stops; it
automatically disappears when finished.
Step I: You may see the following dialog box appear as the License Server service stops; it
automatically disappears when finished.
Page 9 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step M: When this dialog opens, scroll down and select Schneider Electric StruxureWare
WorkStation 1.2.0.767.
Step N: With Schneider Electric StruxureWare WorkStation 1.2.0.767 selected, click on the
Uninstall button along the top.
Page 10 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step O: Accept all of the default options presented in the series of dialog boxes that appear to
uninstall the WorkStation software.
Step P: When complete and back at the Programs and Features dialog box, select Schneider
Electric StruxureWare Device Administrator 1.2.0.767.
With Schneider Electric StruxureWare Device Administrator 1.2.0.767 selected,
click on the Uninstall button along the top.
Accept all of the default options presented in the series of dialog boxes that appear to
uninstall the Device Administrator software.
After successfully uninstalling all of the Schneider Electric StruxureWare software listed in the
Programs and Features dialog, you are ready to proceed with the installation of the Demo Database
v1.3.01.
Page 11 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Software installation
The following details the steps to install the Demo Database v1.3.01. For your convenience, the steps
to install StruxureWare Building Operation v1.3 software are also included.
The procedure detailed here is for:
a demo machine with no StruxureWare Building Operation software installed on it
Uninstall existing StruxureWare Building Operation software for a clean installation.
Note: Existing database contents will be lost.
StruxureWare Building Operation software can be downloaded from the Buildings Business Extranet.
Download the following software installation files:
SE.SBO.Enterprise.Server_1.3.0.938.exe
SE.SBO.Device.Administrator_1.3.0.938.exe
SE.SBO.License.Administrator_1.3.0.938.exe
SE.SBO.WorkStation_1.3.0.938.exe
1. Software pre-requisite
StruxureWare Building Operation v1.3 requires that Microsoft .NET Framework 4 must be
installed first. If your machine does not already have it installed:
a. Download Microsoft .NET Framework 4 from the Internet.
b. Run the installation; you may need to be connected to the Internet during installation.
Step 2a:
Select Next to start installation
Step 2b:
Select I Agree to accept the
License Agreement
Page 12 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 2c:
Confirm all the components are selected
and select Next
Step 2d:
Accept the default License Server
Address and select Install
Step 2e:
The License Administrator is being
installed
Step 2f:
Installation is complete. Select Next
Step 2g:
A successful installation is confirmed.
Select Finish
Page 13 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 3a: Launch the Building Operation License Administrator application by navigating to:
Start > Programs > Schneider Electric StruxureWare > Building Operation 1.3 >
Building Operation License Administrator
Step 3b:
Fill in the required fields (in red) and select Apply.
Step 3c:
From the License Administrator, select the Licenses tab along the top.
Page 14 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 3d:
From the Licenses page, select the Add (+) menu icon and from the drop-down menu, select
Add License From File.
Step 3e:
Browse to the license file (you received from the training department upon request) on your
machine and select. (File name ends in .asr).
Step 3f:
The license has been activated. Select Close.
Step 3g:
The following prompt appears. Select Restart now to restart the License Server.
Page 15 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 3h:
The license is now installed. Select OK to close License Administrator.
Page 16 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 4a:
Select Next to start installation
Step 4b:
Select I Agree to accept the
License Agreement
Step 4c:
Confirm Enterprise Server is
selected and select Next
Step 4d:
Accept the default location for
the database and select Next
Step 4e:
Accept the default Enterprise
Server Configuration Options
and select Next
Step 4f:
Accept the default License
Server Address and select
Install
Step 4g:
The Enterprise Server is being
installed
Step 4h:
Installation is complete. Select
Next
Step 4i:
A successful installation is
confirmed. Select Finish
Page 17 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 5a:
Select Next to start the
installation
Step 5b:
Select I Agree to accept the
License Agreement
Step 5d:
Installation is complete. Select
Next
Step 5e:
A successful installation is
confirmed. Select Finish
Step 5c:
Confirm Device Administrator
is selected and select Next
Page 18 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
6. Install WorkStation
To install Workstation on your computer, launch the SE.SBO.WorkStation installation file
and progress through the following steps:
Step 6a:
Select Next to start installation
Step 6b:
Select I Agree to accept the
License Agreement
Step 6c:
Confirm WorkStation, Graphics
Editor, Script Editor, and
Menta/Function Block Editor
are checked and select Next
WorkPlace Tech Editor is not
required for the Demo
Database
Step 6d:
Accept the default License
Server Address and select
Install
Step 6e:
The Workstation is being
Installed
Step 6f:
Installation is complete. Select
Next
Step 6g:
A successful installation is
confirmed. Select Finish
Page 19 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Page 20 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 8c: Upon log on, you will be prompted to choose a default Workspace. Choose
Engineering.
Page 21 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 8d: The Engineering workspace opens in an Enterprise Server with a clean (i.e. new)
database. Your Workspace should like the following:
If using an Automation Server Hardware Kit, proceed to the Test Demo set
up and communication section.
Page 22 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Otherwise, call Product Support Services for help on installing StruxureWare Building
Operation software. Thus far, the instructions have been software specific and not yet
Demo Database related.
It is possible that the pre-defined port numbers in the Enterprise Server installation are being
used by another application on your demo machine. Try the following to correct.
Step A: Open the Building Operation Software Administrator application.
Step B: Check to see the Communication Ports area to see if any of the fields are in
red. If red, then there is a conflict on the demo machine with another application.
Page 23 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step C: Change the values in the Communication Ports fields (as appropriate on
your demo machine to correct the issue) and click Apply.
This procedure includes sample values and not recommended values for your
demo machine.
Sample values used: HTTP Port = 90, HTTPS Port = 9443
D
C
Step D: If the change is successful, click the Start Service button. Once the
Enterprise Server service starts, the Start Service button text will change to Stop
Service, indicating that the service has successfully started.
Page 24 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
If this procedure does not correct the problem, call Product Support Services for help
on installing StruxureWare Building Operation software. Thus far, the instructions in
this document have been software specific and not yet Demo Database related.
It is possible that the Enterprise Server is not running. If the machine has been restarted, its
possible that the Enterprise Server tried starting before the License Administrator was up and
running and thus failed to start. Try the following to correct.
Step A: Open the Building Operation Software Administrator application.
Step B: Check to see the Enterprise Server is running in the Server section - Status.
Step C: Click on the Start Service button. Once the Enterprise Server service starts,
the Start Service button text will change to Stop Service, indicating that the service
has successfully started.
Step D: Click OK to close the Software Administrator.
Page 25 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step E: Open Building Operation WorkStation to attempt to log into the Enterprise
Server again using the same log on credentials:
User name: admin
Password: admin
Domain: (leave it blank)
Server: localhost
If this procedure does not correct the problem, call Product Support Services for help
on installing StruxureWare Building Operation software. Thus far, the instructions in
this document have been software specific and not yet Demo Database related.
Automation Server
Hardware Kit
Note:
The Demo Database Package v1.3.01 has been changed to only support one Automation
Server Hardware Kit. This Automation Server can be used for any Automation Server model
at v1.3.0.938 including the AS, AS-B, and the AS-L.
You will need two unique valid IP addresses: one for your demo machine and one for your Automation
Server Hardware Kit.
Be sure that the IP addresses used for the demo machine and Hardware Kit do not conflict
with any other accessible IP enabled devices.
If you do not have IP addresses specifically assigned to you for your demo use, use the IP
addresses used in the examples below. These are the same as the ones stored in the Demo
Databases server backup files and will save you some steps throughout the Demo Database
installation process.
Page 26 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
If connecting for the first time, you may need to wait a few minutes as the demo
machine installs the driver for the cable for use with the Device Administrator.
If you receive an error, move the cable to a different USB port of your demo
machine and try again. If still unsuccessful after re-trying, contact Product
Support Services.
If at version 1.3.0.938, then you are ready to proceed to the Automation Server
Hardware Kit IP address section.
o The Automation Server should have a clean database for the Demo Database
installation. To clear the existing contents in your Automation Server, proceed
to Step 9d. The same procedure can be used to clear your database as to
change the version. Make a backup of your existing Automation Server
database before proceeding if you would like to keep it for later use.
If not at version 1.3.0.938, then upgrade the Automation Server using the following
steps.
Page 27 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 9d: If not at version 1.2.0.767, make sure the row corresponding to the Automation
Server is selected and click on the Upgrade Device(s) icon on the upper left.
Step 9e: The following dialog will appear. To upgrade the Automation Server version, click
OK. The upgrade will begin.
If the Type of upgrade dropdown is set to New database, this step will also clear the
Automation Servers existing database.
The Automation Server should have a clean database for the Demo Database
installation. To clear the existing contents in your Automation Server, proceed. Make
a backup of your existing Automation Server database before proceeding if you would
like to keep it for later use.
Page 28 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
This process will take several minutes. When complete, the window will look as shown below:
You may need to wait a few minutes as the demo machine installs the driver for
the cable for use with the Device Administrator.
If you receive an error, move the cable to a different USB port of your demo
machine and try again. If still unsuccessful after re-trying, contact Product
Support Services.
Page 29 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Make sure the row corresponding to the Automation Server is selected and right click on the
highlighted row. Select Network settings.
Page 30 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 10d: Set the IP address and other related network fields (e.g. Netmask, DNS, and
Gateway) as appropriate for your demo set up and click OK.
If using the sample IP addresses and settings:
If not using the sample demo IP rang, make the required changes and click OK.
Step 10e: If you changed, the settings, the following prompt will appear. Select OK to accept
and proceed.
The dialog boxes will close. The highlighted row (corresponding to the Automation Server) in
the Device Administrator window will disappear and reappear (since the Automation Server is
still connected via the USB 2.0 type A/B Device cable).
Step 10f: To verify that the IP address and other settings did change, make sure the row
corresponding to the Automation Server is selected and right click on the highlighted row.
Select Network settings. Verify the new settings in the Properties dialog box. Check the
Current IP address field towards the bottom. Be sure that the DHCP checkbox remains
unchecked.
Step 10g: Click OK to close the Properties dialog box and exit out of the Device
Administrator.
Page 31 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
11. Demo machine IP address (for demo configurations using a Hardware Kit)
The demo machine will need a valid IP address compatible with your demo set ups IP range.
Be sure that the unique IP addresses used for the demo machine and hardware kit do
not conflict with any other accessible IP enabled devices.
If you do not have IP addresses specifically assigned to you for your demo use, use
the IP addresses used in the examples below. These are the same as the ones
stored in the Demo Databases server backup files and will save you some steps
throughout the Demo Database installation process.
Note:
Using these sample IP addresses may prevent you from having access to your own
network or the Internet. This is not a problem for the Demo Database but may affect
functionality for other components you choose to add to the Demo Database.
If using the sample demo IP range, use the following for the demo machines IP address and
subnet mask:
IP address: 192.168.1.100
Subnet Mask: 255.255.255.0
Leave all other fields blank.
Step 11a: Set the demo machines IP address, subnet mask, and other related settings (for
the machines wired network connection) as needed for the demo.
Page 32 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Page 33 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
If using an Automation Server Hardware Kit and you successfully completed the Test
demo set up and communication section, proceed to the Restore backup file in the
Automation Server section.
If using the demo in software-only standalone demo configuration, proceed to the next
section: Demo machine IP address (for software only configuration).
This section describes how to restore the corresponding Demo Database backup file into your
Automation Server.
Step 14a: Download the corresponding backup files and save them onto your demo machine.
The Demo Database package v1.3.01 server backup files can be downloaded from the
Buildings Business Extranet.
Download the following server backup files onto your demo machine:
Page 34 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 14b: Open the Building Operation WorkStation application to log directly into the
Automation Server.
Step 14c: Select the Other user icon and log on using the following user name and
password:
User name: admin
Password: admin
Domain: (leave it blank)
Server: (Automation Server IP address or 192.168.1.99)
Be sure that you are logged in to WorkStation directly to your Automation Server
for this part of the process not logged in to the Enterprise Server.
Do not select the Remember me checkbox. You may connect to other servers, may
want to connect using a different user name, or may want to demonstrate the log on
step.
Step 14d: Upon log on, you will be prompted to select a Default Workspace. Choose
Engineering.
Page 35 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 14e: After logging on, select Server 1 in the system tree. Right click and select
Restore.
Step 14f: The following dialog will appear. Click on Import Backup Set.
Page 36 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 14g: Browse to and select the Demo Database Automation Server .xbk file on the demo
machine: SBO_DemoDB_v1-3-01_AutomationServer.xbk
Note:
The backup file import process will take several minutes to import into the Automation
Server i.e. about 5 minutes.
Step 14h: When import is complete, the imported file will be listed on the left. Select the
imported file name and then click All Data (Configuration and Historical) on the right. With
both selected, click on Restore.
Failure to select All data (Configuration and Historical) will result in missing demo
data. Trend Charts will not be populated.
If the restore file is red, there is an error and the restore cannot proceed. Check the following:
You should be logged directly into the Automation Server using WorkStation.
o This file will work for any Automation Server version i.e. AS, AS-B or AS-L.
The Automation Server must be at version 1.3.0.938.
Step 14i: You will be asked to confirm restore. Click Yes.
Page 37 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 14j: The file will import and the Automation Server will restart. The following two error
messages will appear. Click Close on both dialog boxes. You will be logged off of
WorkStation.
Note:
The database restore process will take several minutes i.e. about 10-15 minutes.
The lights on the Automation Server and the I/O modules will flash as the database is being
restored. In the meantime, move forward to restore the Enterprise Server. Follow the steps in
the next section.
Step 14k: If you are not automatically logged out of WorkStation, close the error message
dialog boxes and manually exit out of WorkStation before proceeding.
Step 15b: Open the Building Operation WorkStation application and log into the Enterprise
Server using the same credentials that allowed you successfully test and pass the Test
successful software and Enterprise Server installation section (i.e. Step 8).
If unable to log on, try the trouble-shooting suggestions in Step 8.
Page 38 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 15c: After logging on, select Server 1 in the system tree. Right click and select
Restore.
Step 15d: The following dialog will appear. Click on Import Backup Set.
Page 39 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Browse to and select the Demo Database Enterprise Server .xbk file. The following dialog will
appear. Click on the Close button.
Step 15e: The imported file will be listed on the left. Select the imported file name and then
click All data (Configuration and Historical) on the right. With both selected, click on
Restore.
Failure to select All data (Configuration and Historical) will result in missing demo
data. Trend Charts will not be populated.
If the restore file is red, there is an error and the restore cannot proceed. Check the following:
You should be logged directly into the Enterprise Server using WorkStation.
The imported file should be for the Enterprise Server i.e. not for the Automation
Server.
Page 40 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 15g: The file will import and the server restart. Click Close. You will be logged off of
WorkStation. If you are not automatically logged out of WorkStation, close the error message
dialog boxes and manually exit out of WorkStation before proceeding.
Step 15h: Wait a few minutes to give the Enterprise Server enough time to restart.
Step 15i: After the restore is complete, open Building Operation WorkStation and log back
into the Enterprise Server.
Step 15j: Upon log on, you will be prompted to Select Default Workspace.
Depending on your expected standard demo set up, choose the following:
If using the software-only standalone demo configuration (no hardware), choose Demo.
If using the Enterprise Server with a Hardware Kit, choose Demo with Hardware Kit.
Page 41 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
If you chose one of the Demo Workspace options, your Workspace should look like the
following upon opening:
If it does, you have successfully restored the Enterprise Server Demo Database.
If you are using the sample Demo Database IP addresses (i.e. 192.168.1.xx)
or the software-only standalone demo configuration (no hardware), there is no
need to change the IP addresses stored in the Enterprise Server. Proceed to
the Delete unused Automation Server section.
Page 42 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
icon.
When docked, you may need to widen the System Tree pane. The Workspace should look like
the following:
Page 43 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 16b: Click on the server name Server 1 at the top of the System Tree. Select the
Communication tab on the right.
Page 44 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 16d: Select the row of the Automation Server. Type in the IP address of the Automation
Server in the Address field of the Communication section on the right. Click on the
icon
to save the changes.
Step 16e: Select the row corresponding to the Enterprise Server. Type in the IP address of
the demo machine (which has the Enterprise Server installed on it) in the Address field on the
right. Click on the
icon to save the changes.
If you were able to successfully set the IP addresses in the Enterprise Server, proceed to the
Set Time Zone and local time section.
Page 45 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
icon.
Page 46 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 17d: The System Tree is updated and the offline Automation Server
icon is removed.
Page 47 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 18c: Select the appropriate time zone from the dropdown menu for the Predefined time
zone field.
Page 48 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 18d: The tab should look as follows with the corresponding Predefined time zone.
Click on the
icon to save the changes.
Page 49 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
19. Set Time Zone and local time in the Automation Server
Step 19a: Click on the server name Automation Server in the Servers folder at the bottom of
the System Tree.
Step 19b: Select the Date & Time tab on the right.
Step 19c: Select the appropriate time zone from the dropdown menu for the Predefined time
zone field. Click on the
icon to save the changes.
Page 50 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 19d: Manually set the local date and time in the Local date & time field. Use the
operating system clock on the demo machine to manually synchronize time between the
Enterprise Server and the Automation Server. Click on the
icon to save the date and time
at the time that matches the machines time.
Page 51 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Page 52 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 21a: While still connected to the Enterprise Server through WorkStation, expand the
System Tree (hidden on the left) and dock it by clicking the
icon (as done in Step 16).
Page 53 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Step 21c: Adjust the settings on the Automation Server Hardware Kits potentiometers,
thermistors, and switches. (The lights are bound to the corresponding switchs value e.g.
Light 1 is bound to Switch 1.)
Verify that the values on the graphic change to match the changes on the Hardware
Kit.
Verify that the values on the left column match the values on the right column.
Lights
Potentiometers
Thermistors
Switches
Page 54 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
Test the direct connection from WorkStation to the Automation Server (bypassing connecting
to the Enterprise Server).
Conceptual representation:
Connects directly to Automation Server
User Interface:
WorkStation
WebStation
Automation Server
Hardware Kit
Presenters
demo machine
Step 21f: Upon log on you will be prompted to Select Default Workspace. Choose Demo
with Hardware Kit.
Page 55 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com
If the Workspace looks as follows when logging onto the Demo with Hardware Kit
Workspace, then the Demo Database appears to be installed correctly in the Automation
Server otherwise this Workspace and graphic would not open.
Page 56 of 56
February 2013
Telephone +1 978-794-0800
www.schneider-electric.com