Anda di halaman 1dari 3

MASTER HPI Plus

MASTER HPI Plus 250W/645 BU-P E40 1SL/12

Quartz metal halide lamps with opalized outer bulb

Product data

General Information LLMF 2000 h Rated 90 %


LLMF 4000 h Rated 82 %
Cap base E40 [ GES]
LLMF 6000 h Rated 77 %
Bulb shape ED-28
LLMF 8000 h Rated 73 %
Operating position H15 [ Hanging +/-15D or Base Up
LLMF 12000 h Rated 68 %
(BU)]
LLMF 16000 h Rated 63 %
Life to 5% failures 5000 h
LLMF 20000 h Rated 60 %
(nom.)
Life to 10% failures 7500 h
(nom.) Operating and Electrical
Life to 20% failures 11000 h
Power (Rated) 250 W
(nom.)
(Nom)
Life to 50% failures 20000 h
Lamp current run-up 3.9 A
(nom.)
(max.)
System description Base-Up/Protected
Lamp current (EM) 2.2 A
LSF 2000 h Rated 99 %
(nom.)
LSF 4000 h Rated 96 %
Ignition supply 198 V
LSF 6000 h Rated 93 %
voltage (max.)
LSF 8000 h Rated 88 %
Ignition peak voltage 5000 V
LSF 12000 h Rated 76 %
(max.)
LSF 16000 h Rated 63 %
Ignition supply 198 V
LSF 20000 h Rated 50 %
voltage (min.)
Ignition time (max.) 10 s
Light Technical Voltage (Max) 138 V
Voltage (Min) 118 V
Luminous flux (rated) 18000 lm
Voltage (Nom) 128 V
(nom.)
Colour designation Cool White (CW)
Chromaticity coordi- 365 Controls and Dimming
nate X (nom.)
Dimmable no
Chromaticity coordi- 363
nate Y (nom.)
Correlated colour 4500 K Mechanical and Housing
temperature (nom.)
Bulb finish Coated [ Coated glass (CO)]
Luminous efficacy 72 lm/W
(rated) (nom.)
Color rendering 65
index (nom.)
MASTER HPI Plus

Approval and Application Product Data


Energy efficiency label A Full product code 871150021147715
(EEL) Order product name MASTER HPI Plus 250W/645 BU-P
Mercury (Hg) 46.5 mg E40 1SL/12
content (nom.) EAN/UPC product 8711500211477
Energy Consumption 278 kWh Order code 21147715
kWh/1000 h Local Code 250HPIPLUSBUP
Numerator quan- 1
tity per pack
Luminaire Design Requirements
Numerator packs 12
Bulb temperature 260 C per outer box
(max.) Material no. (12NC) 928410800027
Cap base tempera- 250 C Net weight (piece) 220.000 g
ture (max.) ILCOS Code ME/S-250/45/2A-H-E40-/V

A lamp breaking is extremely unlikely to have any impact on your


Warnings and Safety
health. If a lamp breaks, ventilate the room for 30 minutes and
remove the parts, preferably with gloves. Put them in a sealed plastic
Use only in totally enclosed luminaire, even during testing
bag and take it to your local waste facilities for recycling. Do not use
(IEC61167, IEC 62035, IEC60598)
a vacuum cleaner.
The luminaire must be able to contain hot lamp parts if the lamp
ruptures
For use with control gear designed for high-pressure mercury or
sodium lamps

Dimensional drawing

D HPI Plus 250W/645 BU-P E40


Product D C

MASTER HPI Plus 250W/645 BU-P E40 1SL/12 90 mm 218 mm


C

HPI, E40

40

2016, March 7
data subject to change
MASTER HPI Plus

Photometric data
600
Fl [mW / (5nm . lm)]

600

[W / (m2 . 5nm . 1000 lux)]


500
500
400
400
300
300
200
200

100 100

300 400 500 600 700 l[nm] 300 400 500 600 700 [nm]

2016 Philips Lighting Holding B.V.


All rights reserved.

Specifications are subject to change without notice. Trademarks are the property of
Koninklijke Philips N.V. (Royal Philips) or their respective owners.

www.philips.com/lighting 2016, March 7


data subject to change