Liebert XD CoolFrame
Fully Integrated Cooling Solution For The Egenera BladeFrame EX System
Liebert XD CoolFrame
Liebert XD Cooling Solutions: An Adaptive Liebert XD Waterless Coolant This unique application of an off-the-
shelf product makes the Liebert XD solution very energy efficient. The XD
Mission-Critical Cooling Architecture That
Coolant operates at low pressure and becomes a gas at room
Accommodates Changes temperatures, making it ideal for use around electronic equipment.
There are two reasons the Liebert XD system uses a waterless refrigerant.
Tighter spacing of racks and higher First, many data center managers are reluctant to re-introduce water into
component density within each rack their facilities because of the possibility of equipment damage from
can require a level of cooling that is leakage. Secondly, the refrigerant used in the Liebert XD system is more
much greater than traditional efficient than water and has advantages in system design and reducing
computer room air conditioning energy costs associated with cooling.
systems can effectively handle. The
number of cooling units needed and Liebert XDCA Coolant Chiller Liebert XDP Pumping Unit
the energy required to operate them Designed For Direct System Designed For Indirect System
Configurations Configurations
make this arrangement extremely
The Liebert XDC Coolant Chiller is a When a building chilled water
inefficient. The Liebert XD CoolFrame specially designed indoor unit that system is available, the Liebert XDP
allows a higher density of BladeFrame connects directly to the Liebert XD Pumping Unit serves as an
EX systems within the data center CoolFrame modules and provides intermediary to isolate the building
than is possible with standard XD Coolant circulation and control. chilled water circuit from the XD
computer room cooling solutions. It ensures that the coolant is Coolant circuit. It circulates coolant
constantly above the dew point in to the Liebert XD CoolFrame at a
the room, eliminating concern for temperature always above the dew
Adding targeted supplemental
condensation. Available with several point to prevent condensation.
cooling is much more cost-
heat rejection options.
efficient than trying to lower the
temperature of localized hot spots Liebert XDC Liebert XDP
by increasing the overall room air H2O Chiller Pumping Unit H2O
conditioning capacity. Liebert
X-treme Density mission-critical
cooling systems are specifically
designed to address the higher
heat loads generated by tightly
packed electronic rack enclosures.
Individual systems can cool hot air
ejected from the enclosure or cool
hot spots or zones near the racks.
An Innovative Cooling Solution For An
Innovative Computing System
Liebert XD CoolFrame
Features Include:
Reliability:
Maintains all BladeFrame
functionality BladeFrame EX
renowned serviceability features
are unaffected. Efficient cable
management is preserved.
Liebert XD CoolFrame modules
attach directly to the rear of the Liebert quality Your assurance of
Egenera BladeFrame EX system. reliability and worldwide support.
Heat removal is provided by
either the Liebert XDC Coolant
Flexibility:
Chiller or a Liebert XDP Pumping
Unit used in conjunction with an Easy to install Simple mechanical
existing chilled water circuit. attachment to the BladeFrame EX.
Liebert XD System Compatibility
Use of the Liebert XD CoolFrame
Fully compatible with Liebert XDP
solution with the BladeFrame EX
and XDC units.
system can promote efficient
expansion of data center capacity Everything you need No
with a minimal impact on your additional air movers are required
data center infrastructure. This for the BladeFrame EX system. No
provides data center managers additional power is required for
with the potential to increase Liebert XD CoolFrame.
processing capacity while
maintaining maximum usage of
floor space. Low total cost of ownership:
Saves on cooling costs Saves
23% of typical data center cooling
energy cost.
Takes up no additional floor space
BladeFrame EX retains same
footprint, even with the Liebert XD
Liebert XD CoolFrame retains CoolFrame modules attached.
same depth and footprint as
BladeFrame EX.
Minimum Number of Liebert 7 2006 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
XD CoolFrame modules All names referred to are trademarks or registered
trademarks of their respective owners.
Liebert and the Liebert logo are registered trademarks
of the Liebert Corporation.
Liebert Liebert
Heat XDC Coolant Liebert XD CoolFrame
Rejection Chiller XD Coolant
Liebert XD CoolFrame Emerson Network Power.
The global leader in enabling
Liebert
XDC Coolant Liebert XD CoolFrame business-critical continuity.
Chiller XD Coolant
Liebert XD CoolFrame
AC Power Systems
Connectivity
DC Power Systems
INDIRECT SYSTEM CONFIGURATION
Embedded Power
Building Liebert Power Protection
XDP Liebert XD CoolFrame
Chilled Integrated Cabinet Solutions
Water XD Coolant Liebert XD CoolFrame
Outside Plant
Liebert Liebert XD CoolFrame
XDP Precision Cooling
Site Monitoring and Services