GENERAL CONCRETE/REINFORCING STEEL 5.

WHERE STEEL MEMBERS ARE WELDED AND NO SIZE IS SPECIFIED, PROVIDE


1. THESE GENERAL NOTES ARE NOT INTENDED TO REPLACE SPECIFICATIONS. 1. CONCRETE COMPRESSIVE STRENGTH IN 28 DAYS: FULL LENGTH FILLET WELDS BOTH SIDES OF MEMBER. WELD SIZES SHALL BE
@ AT INT INTERIOR
SEE SPECIFICATIONS FOR REQUIREMENTS IN ADDITION TO GENERAL NOTES. ELEVATED SLABS ON METAL DECK. . . . . . . 4000 PSI, LIGHTWEIGHT AS FOLLOWS UNLESS NOTED OTHERWISE: & AND JT JOINT
2. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED COLUMNS, BASEMENT WALLS, SITE WALLS . . . 4000 PSI, NORMAL WEIGHT MEMBER THICKNESS (INCHES). . . . . . . . WELD SIZE (INCHES) AB ANCHOR BOLTS K KIP(S)
STRUCTURE, AND, EXCEPT WHERE SPECIFICALLY SHOWN, DO NOT INDICATE SLAB ON GRADE, FOOTINGS, GRADE BEAMS. . . 3000 PSI, NORMAL WEIGHT 3/16 . . . . . . . . . . . . . . . . . . 3/16 ACI AMERICAN CONCRETE INSTITUTE KB KNEE BRACE
THE METHOD OR MEANS OF CONSTRUCTION. THE CONTRACTOR SHALL SUPERVISE 2. REINFORCING: 1/4. . . . . . . . . . . . . . . . . . . 3/16 ADDL ADDITIONAL KSI KIPS PER SQUARE INCH
AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL ASTM A615 - GRADE 60. 5/16 . . . . . . . . . . . . . . . . . . 3/16 AFF ABOVE FINISHED FLOOR LB LONG BAR
CONSTRUCTION MEANS, METHODS, PROCEDURES, TECHNIQUES, AND SEQUENCE. ALL REINFORCING TO BE WELDED - ASTM A706. 3/8. . . . . . . . . . . . . . . . . . . 1/4 AISC AMER. INSTITUTE OF STEEL CONSTRUCTION LBS POUNDS
ALL APPLICABLE SAFETY REGULATIONS TO BE FOLLOWED STRICTLY. WELDED WIRE FABRIC - ASTM A185 (FLAT SHEETS ONLY) 7/16 . . . . . . . . . . . . . . . . . . 1/4 AISI AMERICAN IRON AND STEEL INSTITUTE LLH LONG LEG HORIZONTAL
3. THE STRUCTURE HAS BEEN DESIGNED TO RESIST DESIGN LOADS ONLY AS A 3. GROUT UNDER BASE PLATES TO BE HIGH STRENGTH, NON-SHRINK. 1/2. . . . . . . . . . . . . . . . . . . 5/16 ALT ALTERNATE LLV LONG LEG VERTICAL
COMPLETED STRUCTURE. APPLICATIONS OF CONSTRUCTION LOADS TO THE 4. REFER TO THE DRAWINGS FOR REINFORCING LAP REQUIREMENTS, WHERE LAP 9/16 . . . . . . . . . . . . . . . . . . 3/8 ARCH ARCHITECT'S / ARCHITECTURAL LO LOW
PARTIALLY COMPLETED STRUCTURE SHALL BE CONSIDERED BY THE CONTRACTOR SPLICES ARE NOT SHOWN, LAP PER ACI 318 OR CRSI STANDARDS. 5/8. . . . . . . . . . . . . . . . . . . 7/16 ASTM AMER. SOCIETY FOR TESTING AND MATERIALS LOC LOCATION
AND SO INCLUDED IN THE DESIGN OF SHORING, BRACING, FORMWORK, AND 5. LAP WELDED WIRE FABRIC SHEETS 8" MINIMUM. 6. SPLICING OF STRUCTURAL STEEL MEMBERS IS PROHIBITED WITHOUT PRIOR AWS AMERICAN WELDING SOCIETY LWC LIGHT WEIGHT CONCRETE
ANY OTHER SUPPORTING ELEMENTS PROVIDED FOR CONSTRUCTION OF THE 6. CLEAR COVER FROM FACE OF CONCRETE: APPROVAL OF THE ENGINEER AS TO LOCATION AND TYPE OF SPLICE TO BE B/ or BOT BOTTOM MAX MAXIMUM
STRUCTURE. DURING ERECTION AND UNTIL ALL PERMANENT CONNECTIONS ARE CAST IN PLACE CONCRETE(measure to outermost reinforcing): MADE. ANY MEMBER HAVING A SPLICE NOT SHOWN AND DETAILED ON SHOP BCX BOTTOM CHORD EXTENSION MC MOMENT CONNECTION
MADE, THE CONTRACTOR MUST PROVIDE TEMPORARY BRACING FOR THE WALLS, PEDESTALS . . . . . . . . . . . . . . . . . . . . 2" DRAWINGS WILL BE REJECTED. BFF BELOW FINISHED FLOOR MECH MECHANICAL
STRUCTURE IN ALL DIRECTIONS. COLUMNS (edge of ties) . . . . . . . . . . . . . . . . . 1-1/2" 7. ALL WELDING SHALL CONFORM TO THE AMERICAN WELDING SOCIETY CODE. BLDG BUILDING MFR MANUFACTURER
4. THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND FOOTINGS, . . . . . . . . . . . . . . . . . . . . . . . 3" USE E70 SERIES ELECTRODES FOR ALL STRUCTURAL STEEL WELDS. BM BEAM MID MIDDLE
GRADE CONDITIONS, (BOTH NEW AND EXISTING) REPORTING ANY SLABS EXPOSED TO EARTH AND WEATHER . . . . . . . . . . . 1-1/2" 8. SEE THE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ALL ITEMS REQUIRED BOS BOTTOM OF STEEL MIN MINIMUM
DISCREPANCIES TO THE ARCHITECT PRIOR TO ORDERING MATERIALS OR ELEVATED SLABS . . . . . . . . . . . . . . . . . . . . . 3/4" TO BE HOT-DIP GALVANIZED AFTER FABRICATION. BRG BEARING MISC MISCELLANEOUS
PROCEEDING WITH ANY PHASE OF THE WORK. GRADE BEAMS (edge of stirrups) . . 1-1/2" TOP, 3" BOT, 3" SIDES 9. STRUCTURAL STEEL SHALL BE PUNCHED FOR WOOD BLOCKING, NAILERS, CLIPS BTWN BETWEEN MOW MIDDLE OF WALL
CANT CANTILEVER MP MASONRY PILASTER
5. THE CONTRACTOR SHALL COMPARE STRUCTURAL SECTIONS WITH ARCHITECTURAL 7. PROVIDE REINFORCING IN SLABS ON GRADE, 1-1/2" FROM TOP OF SLAB: AND TIES IN ACCORDANCE WITH ARCHITECTURAL/STRUCTURAL DETAILS.
CJ CONTROL JOINT d NAILS (PENNY)
SECTIONS AND REPORT ANY DISCREPANCY TO THE ARCHITECT PRIOR TO 4" SLABS . . . . . . . . . . . . . . . . . . .6x6-W2.1xW2.1 10. ULTRASONIC INSPECTION BY THE TESTING LABORATORY SHALL BE PROVIDED
CL CENTERLINE No or # NUMBER
FABRICATION OR INSTALLATION OF STRUCTURAL MEMBERS. 8. WHERE SCHEDULED BARS ARE NOT PRESENT, PROVIDE CONTINUOUS #5 TOP AND FOR ALL WELDS CALLED FOR ON THE STRUCTURAL DRAWINGS OR SHOP
CLR CLEAR NS NEAR SIDE
6. DO NOT SCALE DIMENSIONS FROM DRAWINGS. THE CONTRACTOR SHALL REQUEST, BOTTOM BARS TO SUPPORT STIRRUPS AS REQUIRED FOR THE LENGTH OF THE DRAWINGS AS PARTIAL OR FULL PENETRATION WELDS. NTS NOT TO SCALE
CMU CONCRETE MASONRY UNITS
FROM THE ARCHITECT, NECESSARY DIMENSIONS NOT SHOWN ON THE DRAWINGS. STIRRUP SPACING IN ALL BEAMS. 11. ALL STEEL EXPOSED TO VIEW SHALL BE CLASSIFIED AS ARCHITECTURALLY COL COLUMN NWC NORMAL WEIGHT CONCRETE
7. IF ANY BIDDER IS IN DOUBT AS TO THE INTENT OF THE PLANS OR 9. WALL FOOTING REINFORCING SHALL BE CONTINUOUS THROUGH ADJACENT EXPOSED STRUCTURAL STEEL (AESS) AS DEFINED BY THE AISC CODE OF CONC CONCRETE OC ON CENTER
SPECIFICATIONS, THEY SHALL REQUEST AN INTERPRETATION FROM THE COLUMN FOOTINGS. STANDARD PRACTICE AND SHALL BE TREATED AS SUCH. CONN CONNECTION OPNG OPENING
ARCHITECT IN WRITING AT LEAST TEN (10) DAYS PRIOR TO THE SCHEDULED 10. PROVIDE VERTICAL DOVETAIL SLOTS AT 24" OC WITH TIES AT 16" OC IN CONST JT CONSTRUCTION JOINT OPP OPPOSITE HAND
BID DATE. ALL CONCRETE WALLS BACKING-UP MASONRY VENEER. STEEL STAIRS CONT CONTINUOUS PED PEDESTAL
8. PRINCIPAL OPENINGS IN THE STRUCTURE ARE SHOWN ON THESE DRAWINGS. 11. BAR SUPPORTS FOR CONCRETE EXPOSED TO VIEW SHALL HAVE PLASTIC COATED 1. STEEL STAIRS AND LANDINGS AND ALL CONNECTIONS SHALL BE DESIGNED BY CONTR CONTRACTOR PL PLATE
THE GENERAL CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL MECHANICAL, LEGS OR BE HOT DIP GALVANIZED AFTER FABRICATION. THE SUPPLIER FOR A LIVE LOAD OF 100 PSF. TREADS SHALL BE DESIGNED CTRD CENTERED PSF POUNDS PER SQUARE FOOT
ELECTRICAL, AND PLUMBING DRAWINGS FOR REQUIRED OPENINGS AS THEY 12. MECHANICAL AND ELECTRICAL CONDUIT IN SLABS SHALL RUN UNDER TOP FOR A 300 POUND POINT LOAD DISTRIBUTED OVER 4 SQUARE INCHES. ALL DEFL DEFLECTION PSI POUNDS PER SQUARE INCH
SHALL BE PROVIDED FOR WHETHER SHOWN ON THESE DRAWINGS OR NOT. LAYER OF SLAB REINFORCING. PROVIDE A MINIMUM OF 1-1/2" CLEAR HANDRAILS SHALL BE DESIGNED FOR A LATERAL LOAD OF 50 PLF APPLIED DEPR DEPRESSION / DEPRESSED
GENERAL CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL OPENINGS BETWEEN CONDUITS AND BETWEEN REINFORCING AND ADJACENT CONDUITS TO THE TOP OF THE RAIL OR A 200 POUND LOAD AT ANY POINT IN ANY DET DETAIL PT PRESSURE TREATED
WITH ALL SUB-CONTRACTORS PRIOR TO CONSTRUCTION. PARALLEL TO REINFORCING. IF MAXIMUM SIZE OF CONDUIT EXCEEDS ONE DIRECTION WHICHEVER GOVERNS THE DESIGN. ALL STAIR SHOP DRAWINGS DIAG DIAGONAL REF REFERENCE
9. SEE ARCHITECTURAL DRAWINGS FOR FLOOR ELEVATIONS, FLOOR SLOPES, AND THIRD OF THE SLAB DEPTH, ADDITIONAL FRAMING OR REINFORCING MAY BE SHALL BEAR THE SEAL OF A REGISTERED PROFESSIONAL ENGINEER. DIAMETER REINF REINFORCING
THE LOCATION OF DEPRESSED FLOOR AREAS. NECESSARY AT ENGINEERS DISCRETION. CALCULATIONS SHALL BE SUBMITTED UPON REQUEST. DIM DIMENSION REQD REQUIRED
10. THIS PROJECT REQUIRES SPECIAL INSPECTIONS AS DESCRIBED IN SECTION 13. HEADED CONCRETE ANCHORS SHALL CONFORM TO THE REQUIREMENTS OF ASTM DIST DISTANCE
DWG(S) DRAWING(S) SB SHORT BAR
1704 OF THE NORTH CAROLINA STATE BUILDING CODE. SEE STATEMENT A108, GRADES 1010, 1015, 1017, OR 1020. STUDS SHALL BE NON-LOAD BEARING COLD ROLLED STEEL (METAL STUDS) - EXTERIOR WALLS AND
OF SPECIAL INSPECTIONS FOR REQUIRED INSPECTIONS. CONTRACTOR SHALL INTERIOR PARTITION WALLS DWL(S) DOWEL(S) SCHD SCHEDULE
AUTOMATICALLY END WELDED IN THE SHOP OR FIELD IN ACCORDANCE WITH
COORDINATE WITH SPECIAL INSPECTOR ALL WORK REQUIRING SPECIAL THE MANUFACTURER'S RECOMMENDATIONS. 1. ALL COLD FORMED LIGHT GAGE METAL FRAMING AND CONNECTIONS SHALL BE (E) EXISTING SIM SIMILAR
INSPECTIONS AND TESTING. 14. EMBED PLATES MUST BE SET IN THE FORM BEFORE POURING CONCRETE, NOT DESIGNED BY THE SUPPLIER'S ENGINEER. AT ARCHITECT'S OR ENGINEER'S EA EACH SOG SLAB ON GRADE
PLACED INTO TOP OF WET CONCRETE. THE CONTRACTOR SHALL CONTACT THE REQUEST CONTRACTOR SHALL SUBMIT CALCULATIONS FOR ALL COLD FORMED ELEV ELEVATION
SPEC(S) SPECIFICATION(S)
DESIGN CRITERIA METAL FRAMING USED TO SUPPORT CEILINGS AND EXTERIOR CLADDING. EMBED EMBEDDED / EMBEDMENT
ARCHITECT FOR CORRECTIVE DETAILS FOR ANY EMBED PLATES LEFT OUT OF SQ SQUARE
ENGR ENGINEER
1. APPLICABLE CODES: CONCRETE POURS. 2. ALL MEMBERS SHALL BE MANUFACTURED IN ACCORDANCE WITH THE AMERICAN
EQ EQUAL STD STANDARD
A. 2002 NORTH CAROLINA STATE BUILDING CODE (2000 INTERNATIONAL 15. FOR SLABS ON GRADE, SLAB AND GRADE BEAM REINFORCING SHALL BE HELD IRON AND STEEL INSTITUTE, "COLD FORMED STEEL DESIGN MANUAL" (1996).
EQUIP EQUIPMENT STIFF STIFFENER
BUILDING CODE WITH REVISIONS) IN PLACE BY BAR SUPPORTS WITH SAND PLATES, OR PRECAST CONCRETE BAR 3. ALL MEMBERS SHALL HAVE A MINIMUM YIELD STRENGTH OF 33 KSI.
EF EACH FACE
B. BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-99) SUPPORTS AS DESCRIBED IN CHAPTER 3 OF THE CRSI MANUAL OF STANDARD 4. SUBMIT SHOP DRAWINGS FOR ALL COLD FORMED METAL FRAMING USED TO STIRR STIRRUP(S)
EJ EXPANSION JOINT
C. BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-99) PRACTICE. BAR SUPPORTS SHALL BE SPACED AT A MAXIMUM OF 4'-0" OC SUPPORT CEILINGS AND EXTERIOR CLADDING. SHOP DRAWINGS SHALL EOD EDGE OF DECK STL STEEL
D. AISC MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION (1989) BOTH WAYS. ROCKS, CMU, OR CLAY BRICK WILL NOT BE USED AS SUPPORTS. INDICATE PLACING OF ALL FRAMING MEMBERS SHOWING TYPE, SIZE, GAGE, EOS EDGE OF SLAB STR STRUCTURAL
E. AMERICAN WELDING SOCIETY D1. 01-98 16. REBAR SHALL NOT BE HEATED WITH A TORCH IN THE FIELD. NUMBER, LOCATION AND SPACING. THEY SHALL ALSO INDICATE SUPPLEMENTAL EOW EDGE OF WALL T/ TOP
F. MIN DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7-98) 17. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER FAR ENOUGH IN STRAPPING, BRACING, SPLICES, BRIDGING, ACCESSORIES AND DETAILS EW EACH WAY
G. NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS 1997) REQUIRED FOR PROPER INSTALLATION. TCX TOP CHORD EXTENSION
ADVANCE (48 HOURS) OF EACH CONCRETE POUR TO ALLOW AMPLE TIME TO EXIST EXISTING
H. COLD FORMED STEEL DESIGN MANUAL (AISI 1996) CHECK THE LAYOUT OF THE STEEL BEFORE THE BEGINNING OF THE ACTUAL 5. SHOP DRAWINGS SHALL SHOW SIZE AND LENGTH OF WELDS FOR ALL WELDED EXP EXPANSION TOC TOP OF CONCRETE
2. DESIGN LIVE LOADS: POUR, BUT NOT PRIOR TO 90% OF THE STEEL HAVING BEEN PLACED. CONNECTIONS AND TYPE, SIZE AND NUMBER OF SCREWS FOR ALL SCREWED EXT EXTERIOR TOS TOP OF STEEL
ROOF . . . . . . . . . . . . . . . 20 PSF + (10 PSF) CONNECTIONS. SUBMIT MANUFACTURERS DATA GIVING STRENGTH VALUES FOR FDN FOUNDATION TOW TOP OF WALL
OFFICE . . . . . . . . . . . . . . 80 PSF CONCRETE CONSTRUCTION JOINTS SCREWS USED. FFE FINISHED FLOOR ELEVATION TYP TYPICAL
PUBLIC AREAS, LOBBIES . . . . . . 100 PSF 1. CONTRACTOR SHALL PROVIDE NECESSARY CONSTRUCTION JOINTS IN 6. SHOP DRAWINGS SUBMITTED MUST BE PREPARED UNDER THE SUPERVISION OF FS FAR SIDE
FTG FOOTING UNO UNLESS NOTED OTHERWISE
CORRIDORS 2nd and above. . . . . . 80 PSF MONOLITHIC CONCRETE POURS SO THAT THE QUALITY OF PLACEMENT AND AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF
CORRIDORS GROUND. . . . . . . . . 100 PSF FINISH MEETS THE REQUIREMENTS OF PLANS AND SPECIFICATIONS. THE NORTH CAROLINA. GA GAUGE VERT VERTICAL
STAIRS. . . . . . . . . . . . . . 100 PSF CONTRACTOR SHALL SUBMIT A PLAN SHOWING THE LOCATION OF ALL GALV GALVANIZED VIF VERIFY IN FIELD
STORAGE . . . . . . . . . . . . . 125 PSF CONSTRUCTION JOINTS TO THE STRUCTURAL ENGINEER FOR APPROVAL. EPOXY AND EPOXY GROUT HD HEADED W/ WITH
MECHANICAL ROOM . . . . . . . . . 150 PSF 2. THERE SHALL BE NO HORIZONTAL CONSTRUCTION JOINTS IN CONCRETE POURS. 1. ANCHOR BOLTS, REINFORCING STEEL, THREADED RODS, STAIR HANDRAILS, HI HIGH
WWF WELDED WIRE FABRIC
3. SNOW LOAD: ALL VERTICAL CONSTRUCTION JOINTS IN SLABS AND BEAMS SHALL BE MADE AND OTHER EMBEDDED STEEL ITEMS SHALL BE SET INTO HARDENED CONCRETE HORIZ HORIZONTAL
GROUND SNOW LOAD (Pg). . . . . . . 15 PSF WITH BULKHEADS. ADDITIONAL REINFORCING AT CONSTRUCTION JOINTS SHALL WITH EPOXY OR EPOXY GROUT ONLY WHERE DETAILED ON THE DRAWINGS OR HSS HOLLOW STRUCTURAL SECTION
FLAT ROOF SNOW LOAD (Pf) . . . . . 16.5 PSF BE AS SPECIFIED BY THE STRUCTURAL ENGINEER. SEE TYPICAL WHERE APPROVED BY THE ENGINEER.
SNOW EXPOSURE FACTOR (Ce). . . . . 0.9 CONSTRUCTION JOINT DETAILS. 2. MANUFACTURER'S DATA FOR ALL EPOXY AND EPOXY GROUT SHALL BE SUBMITTED
SNOW LOAD IMPORTANCE FACTOR(Is). . 1.1 TO THE ENGINEER FOR APPROVAL PRIOR TO INSTALLATION.
THERMAL FACTOR (Ct). . . . . . . . 1.0 ACCEPTABLE EPOXY PRODUCTS ARE:
4. WIND LOAD: (2002 NORTH CAROLINA BUILDING CODE/IBC) STRUCTURAL MASONRY HILTI HY150, HILTI HSE2421, MASTER BUILDERS CONCRESIVE STANDARD PASTE,
BASIC DESIGN WIND VELOCITY . . . . 95 MPH 1. LOAD-BEARING MASONRY WALLS, PILASTERS, PIERS, RETAINING WALLS, SIMPSON STRONG-TIE ET OR APPROVED EQUAL. IN USING THE ABOVE PRODUCTS,
OCCUPANCY CLASSIFICATION . . . . . CATEGORY II FOUNDATION WALLS AND ANY OTHER MASONRY SO DESIGNATED ON DRAWINGS IS FOLLOW STRICTLY THE MANUFACTURER'S SPECIFICATIONS AND DIRECTIONS FOR
EXPOSURE CATEGORY. . . . . . . . . C CONSIDERED HERE TO BE STRUCTURAL MASONRY. MIXING AND APPLICATION. HEED ALL LABEL WARNINGS. INSTALL IN
IMPORTANCE FACTOR (Iw) . . . . . . 1.15 2. REQUIRED COMPRESSIVE STRENGTH OF MASONRY UNITS: ACCORDANCE WITH APPLICABLE SAFETY LAWS.
INTERNAL PRESSURE COEFF (GCpi) . . +-0.18 SOLID CLAY UNITS. . . . . . . . . . . .6200 PSI 3. ALL EPOXY AND EPOXY GROUT SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH
WIND BASE SHEARS . . . . . . . . . Vx=195K CONCRETE UNITS. . . . . . . . . . . . .1900 PSI ON NET AREA OF 8,000 PSI AND TENSILE STRENGTH OF 2,300 PSI.
Vy=85K 3. CONCRETE MASONRY UNITS (CMU) SHALL BE LIGHTWEIGHT (105 PCF) GRADE N, 4. ALL HOLES SHALL BE DRILLED WITH A DIAMETER NO LARGER THAN 1/8"
CONFORMING TO ASTM C90. REFER TO ARCHITECTURAL DRAWINGS AND GREATER THAN THE DIAMETER OF THE STEEL MEMBER BEING INSTALLED.
COMPONENTS AND CLADDING: SPECIFICATIONS FOR UNIT SIZE, FACE, COLOR, JOINTING, ETC. 5. ALL HOLES SHALL BE CLEANED WITH COMPRESSED AIR AND SHALL BE DRY
ALL BUILDING COMPONENTS AND CLADDING ENGINEERED BY THE COMPONENT 4. MORTAR - TYPE S, ASTM C270. PRIOR TO INSTALLATION OF EPOXY. HOLES SHALL BE FREE OF ALL
MANUFACTURER ARE TO BE DESIGNED BY THE MANUFACTURER'S ENGINEER 5. GROUT FOR REINFORCED MASONRY - FINE GROUT, ASTM C476. MINIMUM DELETERIOUS MATERIAL SUCH AS LAITANCE, DUST, DIRT, AND OIL.
FOR WIND LOADS DETERMINED PER THE NORTH CAROLINA STATE BUILDING 28-DAY COMPRESSIVE STRENGTH - 2000 PSI. 6. CONTRACTOR PERFORMING EPOXY WORK SHALL BE AN APPROVED CONTRACTOR BY
CODE FOR THE BASIC DESIGN WIND VELOCITY, IMPORTANCE FACTOR, AND 6. MINIMUM 28-DAY COMPRESSIVE STRENGTH (F'm) OF THE MASONRY WALLS THE MANUFACTURER FURNISHING THE EPOXY MATERIALS, AND SHALL HAVE NO
EXPOSURE LISTED ABOVE. SHALL BE 1500 PSI. MASONRY STRENGTH SHALL BE DETERMINED BY THE UNIT LESS THAN FIVE YEARS EXPERIENCE IN THE VARIOUS TYPES OF EPOXY
5. SEISMIC LOAD: (2002 NORTH CAROLINA BUILDING CODE/IBC) STRENGTH METHOD OR THE PRISM TEST METHOD AS DESCRIBED BY ACI 530. RELATED WORK REQUIRED IN THIS PROJECT. A NOTARIZED CERTIFICATION
DESIGN METHOD: EQUIVALENT LATERAL FORCE PROCEDURE 7. REINFORCING: FROM THE MANUFACTURER ATTESTING TO THE TRAINING SHALL BE SUBMITTED
SDs. . . . . . . . . . . . . . . . 0.179 ASTM A615 - GRADE 60. TO THE ENGINEER/ARCHITECT ALONG WITH THE PROPOSAL TO DO THE WORK.
SD1. . . . . . . . . . . . . . . . 0.119 ALL REINFORCING TO BE WELDED - ASTM A706.
IMPORTANCE FACTOR (Ie) . . . . . . 1.25 8. REFER TO THE DRAWINGS FOR REINFORCING LAP TYPICAL DETAIL AND SCHEDULE LOAD BEARING COLD ROLLED STEEL (METAL STUDS)
SEISMIC USE GROUP. . . . . . . . . II REQUIREMENTS, WHERE LAP SPLICES ARE NOT SHOWN, LAP PER ACI 530. 1. SEE LEVEL 1 FRAMING (RAISED SEATING) FOR LOCATION OF LOAD BEARING
SITE CLASS . . . . . . . . . . . . C 9. MAXIMUM HEIGHT TO WHICH MASONRY SHALL BE LAID BEFORE GROUTING IS STUDS. SEE ROOF FRAMING FOR JOIST LOCATIONS.
SEISMIC DESIGN CATEGORY. . . . . . B 5 FEET. MAXIMUM GROUT POUR HEIGHT IS 5 FEET. IF GROUT POUR HEIGHT 2. ALL LOAD BEARING STUDS, JOISTS, AND ACCESSORIES SHALL BE MADE OF
BASIC SEISMIC-FORCE RESISTING SYSTEM: CONCENTRICALLY BRACED FRAMES EXCEEDS 5 FEET PROVIDE CLEANOUT OPENINGS AT THE BOTTOM OF EACH THE MINIMUM TYPE, SIZE, GAUGE, AND SPACING SHOWN ON DRAWINGS.
STEEL SYSTEM NOT SPECIFICALLY GROUT POUR. CLEANOUT OPENINGS SHALL BE PROVIDED AT EACH CELL TO BE 3. ALL STRUCTURAL MEMBERS SHALL BE MANUFACTURED IN ACCORDANCE WITH THE
DETAILED FOR SEISMIC RESISTANCE FILLED WITH GROUT. AMERICAN IRON AND STEEL INSTITUTE "COLD-FORMED STEEL DESIGN MANUAL"
Rx=3.0 Cdx=3.0 10. REINFORCE MASONRY WHERE SHOWN ON STRUCTURAL DRAWINGS. TIE REINFORCING (1996).
Ry=3.0 Cdy=3.0 IN POSITION AND PLACE GROUT AROUND REINFORCING. DO NOT PUSH REINFORCING 4. ALL STRUCTURAL MEMBERS SHALL HAVE A MINIMUM YIELD STRENGTH OF 33 KSI.
SEISMIC BASE SHEARS. . . . . . . . Vx=188K DOWN INTO PREVIOUSLY PLACED GROUT FILL. SET BOLTS SIMILARLY. 5. MINIMUM LOAD BEARING WALL STUD EFFECTIVE PROPERTIES:
Vy=188K 11. TIE MASONRY WYTHES WITH HORIZONTAL REINFORCING AS SPECIFIED. 5
38" -18GA: Ix=0.71 in4 Sx=0.389 in3 A=0.34 in2
6. FUTURE LOADS: UNLESS SPECIFICALLY NOTED, THERE ARE NO PROVISIONS 12. PROVIDE VERTICAL BARS, SIZE MATCHING WALL REINFORCING, AT ALL 6"-18 GA.: Ix=2.86 in4 Sx=0.953 in3 A=0.556 in2
MADE FOR FUTURE FLOORS, ROOFS, OR OTHER LOADS. CORNERS, ENDS OF WALLS, EACH SIDE OF CONTROL JOINTS AND EACH SIDE 6. MINIMUM FLOOR/ROOF STUD JOIST EFFECTIVE PROPERTIES:
OF WALL OPENINGS. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF 8"-16 GA.: Ix=5.736 in4 Sx=1.434 in3 A=0.67 in2
FOUNDATIONS CONTROL JOINTS. 7. SUBMIT SHOP DRAWINGS FOR ALL LOAD BEARING COLD FORMED METAL
1. FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL INVESTIGATION REPORT 13. ALL CORNERS AND INTERSECTIONS OF STRUCTURAL MASONRY WALLS SHALL BE FRAMING. SHOP DRAWINGS SHALL INDICATE PLACING OF ALL FRAMING
BY TAI AND ASSOCIATES DATED 04/01/05. (TAI PROJECT #05-105-1). THE DESIGN CONSTRUCTED BY INTERLOCKING COURSES. MEMBERS SHOWING TYPE, SIZE, GAGE, NUMBER, LOCATION AND SPACING.
ALLOWABLE SOIL BEARING PRESSURE IS 8,000PSF, BASED ON THIS REPORT. 14. ALL LINTELS TO BEAR 8" MINIMUM EACH SIDE OF OPENING, UNLESS NOTED THEY SHALL ALSO INDICATE SUPPLEMENTAL STRAPPING, BRACING, SPLICES,
2. FOOTINGS SHALL BE CARRIED TO LOWER ELEVATIONS THAN THOSE SHOWN ON OTHERWISE. BRIDGING, ACCESSORIES AND DETAILS REQUIRED FOR PROPER INSTALLATION.
THE DRAWINGS IF REQUIRED BY THE GEOTECHNICAL ENGINEER OR TESTING LAB 8. SHOP DRAWINGS SHALL SHOW SIZE AND LENGTH OF WELDS FOR ALL WELDED
TO REACH SOIL CAPABLE OF PROVIDING THE DESIGN ALLOWABLE SOIL BEARING STRUCTURAL STEEL CONNECTIONS AND TYPE, SIZE AND NUMBER OF SCREWS FOR ALL SCREWED
PRESSURE. 1. STRUCTURAL STEEL: CONNECTIONS. SUBMIT MANUFACTURERS DATA GIVING STRENGTH VALUES FOR
3. THE SUBGRADE AND UNDERFLOOR FILL SHALL BE PREPARED TO A POINT WIDE FLANGE SHAPES (W SECTIONS) - ASTM A992, GRADE 50, FY= 50 KSI SCREWS USED.
THAT EXTENDS 5'-0" MINIMUM BEYOND THE LIMITS OF THE FOUNDATION. CHANNELS, ANGLES, PLATES, RODS, AND BARS - A36, FY = 36 KSI
4. MINIMUM SUBGRADE PREPARATION REQUIREMENTS ARE AS FOLLOWS: SQUARE AND RECTANGULAR TUBES ASTM A500 - GRADE B, FY= 46 KSI REPRODUCTION NOTE
COMPACT ALL FILL UNDER BUILDING TO 98% MAXIMUM DENSITY AS DETERMINED PIPES ASTM A53- GRADE B, FY= 36 KSI 1. THE USE OF REPRODUCTIONS OF THESE CONTRACT DRAWINGS BY ANY
BY ASTM D698. PLACE IN LAYERS OF 8" MAXIMUM LOOSE THICKNESS. 2. ANCHOR BOLTS AND THREADED RODS SHALL CONFORM TO ASTM A36 OR A307. CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR, OR MATERIAL
VERIFY FIELD DENSITY, ASTM D1556, WITH AT LEAST ONE TEST PER 2000 3. DESIGN, FABRICATION AND ERECTION: AISC MANUAL OF STEEL CONSTRUCTION, SUPPLIER IN LIEU OF PREPARATION OF SHOP DRAWINGS SIGNIFIES HIS
SQUARE FEET PER LAYER. SEE SPECIFICATIONS FOR OTHER TESTING ASD. NINTH EDITION (1989). ACCEPTANCE OF ALL INFORMATION SHOWN HEREON AS CORRECT, AND
REQUIREMENTS. 4. BEAM SIMPLE, SHEAR CONNECTIONS NOT DETAILED ON STRUCTURAL DRAWINGS OBLIGATES HIMSELF TO ANY JOB EXPENSE, REAL OR IMPLIED, ARISING DUE
5. WALLS RETAINING SOIL SHALL BE TEMPORARILY BRACED DURING BACKFILLING SHALL BE DESIGNED BY STEEL SUPPLIER FOR LOADS SHOWN ON DRAWINGS OR TO ANY ERRORS THAT MAY OCCUR HEREON.
AND UNTIL ALL SUPPORTING SOIL AND SLABS ARE IN PLACE AND ARE AT FOR REACTIONS DETERMINED BY USING THE ALLOWABLE UNIFORM LOAD AS
DESIGN STRENGTH UNLESS NOTED OTHERWISE ON PLANS AND DETAILS. TABULATED IN PART 2 OF THE AISC MANUAL OF STEEL CONSTRUCTION FOR
6. UTILITY LINES SHALL NOT BE PLACED THROUGH OR BELOW FOUNDATIONS WITHOUT THE SECTION, SPAN AND STRENGTH OF STEEL SPECIFIED.
APPROVAL OF THE STRUCTURAL ENGINEER. CONTRACTOR SHALL SUBMIT DETAILED CONNECTIONS: 3/4" DIAMETER BOLTS, ASTM A325 TIGHTENED TO A SNUG-
DRAWINGS OF ALL SUCH CONDITIONS PRIOR TO CONSTRUCTION. TIGHT CONDITION PER AISC REQUIREMENTS.

S0.00