DATA SHEET
DEAERATOR PUMPS
Date
DAT
DWG. TYPE
SAUDI ARABIA
Chk
A10-G-1002A/B
PLANT NO.
SAUDI ARABIAN OIL COMPANY
MECHANICAL DATASHEET
G
DEAERATOR PUMPS (BLOCK1)
INDEX
Appvd
JAZAN IGCC POWER BLOCK PROJECT
ATTACHMENT #4 DATA SHEET
PM
DRAWING NO.
VE-068279
SHT.NO
SAPMT
1 of 7
A
REV.NO.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Saudi Aramco 2741-M-ENG (11/2010)
PUMP MFR HYOSUNG GOODSPRINGS INC ELECTRICAL AREA Note 2 , DIV. , GROUP
REVISION DESCRIPTION
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
SERIAL NO. 1500777-001~002 PERFORMANCE DATA
DRIVER TYPE INDUCTION MOTOR PERFORMANCE
THIS DATA SHEET COVER 2 PUMP(S) RATED SPEED RPM 1788
PUMP MARK NO(S). -G- , -G- DRIVER NAME PLATE POWER RATING kW 500
-G- , -G- RPM 1780
PUMPS OF IDENTICAL TYPE & SIZE IN OPERATION 100% 120%
10-01525-0004
MIN. CONT.
NORMAL
18-May-2015
-G- , -G-
DRIVER DATA SHEET A10-P-DAT-VE-288619 TOTAL DIFF. HEAD m 185.8 171.2 167 155.1
JOB ORDER/EWO NO.
-G-
-G- MINIMUM CONTINUOUS STABLE FLOW m3/h 338
MINIMUM CONTINUOUS THERMAL FLOW m3/h 338
LIQUID CHARACTERISTICS MAXIMUM OPERATING TIME AT SHUT-OFF s0
LIQUID PUMPED water contain ammonia (0-2ppm) TDS 0 mg/L FIRST CRIT. SPEED; DRY RPM 2314
NST. AGENCY/DATE
18-May-2015
B. Anders
CHARACTER OF SOLIDS: PULPY GRITTY HARD SOFT TOT.DIFF. HEAD AT RATED m 181.3 N/A
DESIGN CERTIFICATION
GAS IN FLUID: NONE VOL. % UNKNOWN EFFICIENCY AT RATED CAPACITY % 69.2 N/A
(DESIGN AGENCY)
INTERMEDIATE TRANSMISSION
OPERATING CONDITIONS
GEAR BOX RATIO
18-May-2015
ENGG./DATE
% % OF DRIVER SPEED
RATED m3/h 741.4 CONSTRUCTION DATA
RATED TOTAL DIFFERENTIAL HEAD m 167 PUMP TYPE
NPSH AVAILABLE AT SUCTION FLG. HORIZONTAL (BET. BRGS) OVERHUNG
AT MAX FLOW RATE CASE m 8.906 VERT. IN-LINE INTEGRAL SHAFT
AT 120% OF RATED CAPACITY m 8.882 CASING MOUNT: CENTERLINE FLANGE CENTERLINE
1 1 1
IS COVERED, FOR ALL APPROVAL
SUC.PRESSURE AT MAX FLOW RATE CASE bar(abs) 5.156 VERT. IN-LINE IN-LINE CASE SUPPORTED
DIS.PRESSURE AT MAX FLOW RATE CASE bar(abs) 20.21 CASING SPLIT AXIAL RADIAL
DIFF. PRE. AT MAX FLOW RATE CASE bar 15.054 CASING TYPE DOUBLE VOLUTE SINGLE VOLUTE
MAX. SUCT. PRE. AT SHUT-OFF bar(abs) 14.3 DIFFUSOR STAGGER
REVISION VALIDATION
MAX. DIS. PRE. AT SHUT-OFF (NOTE 22) bar(abs) 34.6 SELF PRIMING YES NO
DRAWING COMPLETION CERTIFICATE NO.
DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.
SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
/ ALLOWABLE FORCES AND MOMENTS
TOP NOZZLE SIDE NOZZLE END NOZZLE EACH INBOARD / OUTBOARD
10-01525-0004
CASING DRAIN(S) 2 3/4" V/V WITH FLANGE NUMBER OF STAGES 1(ONE) STAGE STAGE
18--May-2015
SHAFT DIAMETER AT 1ST STAGE IMPELLER mm 104 1st STAGE IMPELLER INLET
B. Anders
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF S
B
SHAFT SEALING
PACKED STUFFING BOX PACKING MAT'L.
PROVIDED WITH LANTERN RING: YES NO
18-May-2015
ENGG./DATE
DEAD ENDED
FLUSH WITH LIQUID PUMPED GREASE p
Dh2
Dsl
Dp
4TH LETTER F
d
IS COVERED, FOR ALL APPROVAL
5TH LETTER N
PIPING FOR PRIMARY SEAL API FIG. D-2 PLAN #23 Dp = 266.7 mm
PIPING FOR THROTTLE BUSHING OR Dsl = 114 mm (IF APPLICABLE)
REVISION VALIDATION
DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.
NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
TILTING PAD DIAPHRAGM DISC PACK
LUBRICATION METHOD RADIAL THRUST RIGID ADJUSTABLE
GREASE CLOSE COUPLED
RING-OIL CONSTANT LEVEL ELASTOMERIC
/ LUBRICATOR, MAKE HYDRAULIC FIT KEYED
OIL BATH WITH EXT'L CIRCULATION SPACER: YES, 300 mm NO
18-May-2015
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. N
LUBE OIL SYSTEM SUPPLIED BY: PUMP VENDOR 6 SHAFT SLEEVES ASTM 316SS
CERTIFIED/DATE
SHAFT MOUNTED FAN JACKETED BEARING PIPING: PIPE / FITTINGS ASTM 316L SS
Y. Wang
14
COILS IN BEARING HOUSING 15 BASE PLATE ASTM A36
16 MECH. SEAL SPRINGS ASTM HASTELLOY-C
EXTERNAL CIRCULATING SYSTEM 17 MECH. SEAL OTHER METAL ASTM 316L SS
OIL COOLING BY: 18 ASTM
LIQ. PUMPED FOREIGN LIQ. AIR NONE 19 ASTM
STUFFING BOX COOLING YES NO
IS COVERED, FOR ALL APPROVAL
O
TEMP. INLET C
O
TEMP. OUTLET C
COOLING MEDIUM
THIS REVISION NO.
DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
DI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
REVISION DESCRIPTION
OBSER'D
CERT'D
WITN'D
NONE
ELECTRIC POWER AVAILABLE VENDOR'S STANDARD SHOP TEST
AC PHASE AS FOLLOWS
VOLTS
DC HZ HYDROSTATIC TEST
MAIN ELECTRIC DRIVER AC 4000 3 / 60 WATER KEROSENE
CONTROLS AND PROTECTION AC 460 3 / 60 RUNNING TEST
18-May-201
DC 24 PERFORMANCE TEST
10-01525-0004
DATE
VIBRATION, MEASUREMENTS
WELL WATER TREATED WATER SEA WATER TESTS TO BE CARRIED WITH:
ONCE THROUGH SYSTEM CLOSED LOOP SYSTEM ACTUAL DRIVER MANUFACTURER'S DRIVER
AT RATED SPEED DERATED SPEED: RPM
INSTRUMENTATION & CONTROLS
OPERATIONS/DATE
YES REQUIRED
PROVISIONS ONLY YES NO
DIMENSIONAL DRAWING OF
CONST. AGENCY/DATE
O
ALARM SETTING C 95 95 COMPLETELY ASSEMBLED UNIT
O
SHUTDOWN SETTING C 100 100 OPER. & MAINT. INSTRUCTIONS
CROSS SECT. DRW. WITH PART NO'S.
VIBRATION / DISPLACEMENT MONITORING MECHANICAL SEAL DRAWING
BILLS OF MATERIALS
POSITION RADIAL BRG'S THRUST BRG. BRG. HSG COMPLETED PUMP DATA SHEET
TYPE PROXIMITY PROXIMITY SEISMIC AUXILIARY PIPING DWG.
CERTIFIED TEST CURVE & DATA
YES RECOMMENDED SPARES LIST
PROVISIONS ONLY INSTR WIRING DIAGRAM
INSTR.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUD
CERTIFIED/DATE
18-May-2015
mm/s RMS /
/
SEISMIC PNEUMATIC MISCELLANEOUS
ELECTRICAL
18-May-2015
PROXIMITY PAINTING
ENGG./DATE
Y. Wang
31-SAMSS-004
/ PUMP kg 1880 ASME B 73.1 ASME B 73.2
DRAWING COMPLETION CERTIFICATE NO.
REVISION VALIDATION
DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
Engineering Notes:
0
1. Nozzle rating is estimated, need to be confirmed by Pump vendor after Hazop action. And the Nozzle load shall take 3 times of API 610-10th table 4.
2. Equipment will be located in Unclassified Area.
3. Those are operation flow only, margin of +10% of operation flow needs to be considered by pump vendor at pump selection and design.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
4. The same pump tag numbers with A, B suffix will be operated 2100%, one for operation and the other for standby.
5. Vendor to fill the blank of this data sheet, as well as datasheets attached in SEP-PGB-ME-REQ-0003-002 completely.
6. Pump shall be designed as per 31-SAMSS-004 and A10-A-DOC-VE-068274.
7. Electric motor datasheet shall refer to A10-P-DAT-VE-288619, and electric motors shall be in accordance with 17-SAMSS-502.
18-May-2015
8. "Operating Conditions: Each Pump" shown in below table represents operating conditions for the Deaerator Pump.
10-01525-0004
DATE
9. The inspection & testing requirement shall be as per SAUDI ARAMCO form 175.
JOB ORDER/EWO NO.
10. Mechanical Seal and support system shall be in accordance with 31-SAMSS-012. Mechanical seal configuration is 1CW-FX, Category 2,
Arrangement 1, Seal Type A.
11. Machinery proection system shall be in accordance with 34-SAMSS-625.
REV. NO.
12. Electrical installations shall be in accordance with 17-SAMSS-515, and all instrumentations shall be in accordance with 34-SAMSS-831.
00
13. All auxiliary piping design, joint fabrication, examination and inspection shall comply with 01-SAMSS-017.
14. Pump material shall be according to standard Saudi Aramco Drawing AD-036821-001.
15 PMI (Positive Material Identification) testing shall be inaccordance with SAES-A-206.
16. Copper or copper alloys shall not be used for any components exposed to the atmosphere.
BY/DATE
OTHER
17. Refer to project design data (Document No. A10-A-DOC-VE-911677) for available utilities and site data.
18. Refer to A10-A-DOC-VE-046373, SAES-H-001 and SAES-H-101V for coating selection and application.
19. The coolers for seal flushing system if needed will be water-cooled type, the utility consumption of which should be provided by vendor.
20. The vibration, position , temperature detectors&transmittals on pumps and motors shall match Bently Nevada 3500. And extension cables and junction
boxes should be within vendor's scope.
OPERATIONS/DATE
21. The cooler for the seal flush plans 23 shall be sized to maintain the flush fluid at or below 60 .
22. Vendor to note that the shutoff pressure shall NOT exceed +25% difference pressure at rated flow rate .
23. Estimated hydraulic power is 310 kW.
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)
24 Motor rated power to be at least 110% of pump SBHP or pump rated impeller end of curve which is less.
CONST. AGENCY/DATE
CERTIFIED/DATE
18-May-2015
B. Anders
DESIGN CERTIFICATION
(DESIGN AGENCY)
18-May-2015
ENGG./DATE
Y. Wang
CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER DRAWING
DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.
O. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
GENERAL INFORMATION
0
10-01525-0004
DATE
PURCHASER'S REQUIREMENTS
REV. NO.
This form shall be completed for each piece of equipment (or integrated unit) that is likely to generate noise in excess of 85
00
dBA at a distance of one meter. If the noise level is greater than 90 dBA, the cost of special design and/or acoustic treatment
should be supplied. Measurements are to be made in accordance with ANSI S1.13 and at full design load, unless otherwise
indicated. For rotating electric machinery, use points defined in IEEE Standard 85.
BY/DATE
OTHER
OPERATIONS/DATE
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO
(Hz) Design Design Treatment
CERTIFIED/DATE
(Hz)
18-May-2015
DESIGN CERTIFICATION
B. Anders
63
(DESIGN AGENCY)
20 - 75
75 - 150 125
150 - 300 250
500
18-May-2015
300 - 600
ENGG./DATE
Y. Wang
DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
DRAWING COMPLETION CERTIFICATE NO. XF.Du B.Anders JOB ORDER/EWO NO. THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
08-Jan-15 08-Jan-15 10-01525-0004 UNTIL CERTIFIED AND DATED
JAZAN
Saudi Aramco 2616-ENG (11/2010)
A
B
C
D
DEAERATOR
Rev
DATA SHEET
Date
9-Sep-14
7-Dec-14
10-Oct-14
Description
Issued for Review
Issued for Review
Issued for Review
Issued for Review
Prep
XF.Du
XF.Du
XF.Du
XF.Du
DAT
SAUDI ARABIA
DWG. TYPE
Chk
LY.Dun
LY.Dun
LY.Dun
LY.Dun
DEAERATOR
A10
PLANT NO.
POWER GENERATION
A10-D-4002; A10-D-5002
D
INDEX
Appvd
HY.Liang
HY.Liang
HY.Liang
HY.Liang
A10-D-1002; A10-D-2002; A10-D-3002;
PM
DRAWING NO.
B.Anders
B.Anders
B.Anders
B.Anders
VD-068278
6
1
OF
SHT.NO
SAPMT
D
REV.NO.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
SAUDI ARABIAN OIL COMPANY
DEAERATORS A10-D-1002; A10-D-2002; A10-D-3002; A10-D-4002; A10-D-5002
12 Enthalpy
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
DATE
Service Pressure
10-01525-0004
18
19 Outlet 379132 683744 152 640.6 4.0
20
Outlet Vent 380 684 152 2747
21
BY/DATE
OTHER
22
23
24
Pump Kickback Hold
25
Sparger by supplier
26
OPERATIONS/DATE
Deaerator Drain
27
Overflow by supplier
28
V.B.Vent
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)
29
R.V. by supplier
30
31
32
CONST. AGENCY/DATE
33
34
35
36
37
38 Notes:
39
CERTIFIED/DATE
40 1) A design margin of 10% shall be added to the Design flow specified above to size the deaerator. Supplier to provide storage capacity for
08-Jan-15
B.Anders
42 2) Steam inlet source is from Low pressure (LP) / Auxiliary steam header
(DESIGN AGENCY)
43 3) Effluent Guarantee : Oxygen shall be reduced to less than 0.005 ml/l (7ppb).
44 Carbon dioxide shall be zero in effluent as measured by APHA.
45 4) Both heater and Storage Vessels shall be (service)post weld heat treated to relieve residual stresses from fabrication.
46 5) All longitudinal and circumferential pressure containing welds shall be 100% radiographed.
ENGG./DATE
08-Jan-15
47 6) Vacuum rings shall be utilized in the design of the deaerator. Supplier to confirm number, size & spacing.
XF.Du
48 7) Supplier shall furnish as a minimum the equipment, all components & accessories shown on the sketch (SHT 5 of 6)
49 and as specified on the data sheet.
50 8) One (1) 2" isolatable Vent connection (with manual bypass) shall be furnished by supplier for the Heater Vessel.
51 Supplier to confirm flow rates.
52 9) Dissolved oxygen in the polished condensate inlet is 1 mg/l ; the maximum concentration is 7 mg/l.
53 10) Manual overflow trap provided by Purchaser. Inlet level control valve by Purchaser.
54 11) Vendor to verify capacity based on operating condition.
55 12) Pressure loss from condensate inlet connnection to deaerator steam space shall not exceed 0.2 bar.
IS COVERED, FOR ALL APPROVAL
56
57
58
59
REVISION VALIDATION
60
61
DRAWING COMPLETION CERTIFICATE NO.
62
63
64
65
D
66
67
THIS REVISION NO.
68
DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.
DEAERATOR DAT 2
POWER GENERATION UNIT A10 D VD-068278 OF D
JAZAN SAUDI ARABIA 6
SAUDI ARABIAN OIL COMPANY
DEAERATORS A10-D-1002; A10-D-2002; A10-D-3002; A10-D-4002; A10-D-5002
13
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER
10-01525-0004
14
JOB ORDER/EWO NO.
17
Model No. Provided by : Note 10 Note 10
18
D
Size : Material :
23
Type : Level Control
24
Material : Manufacturer :
25
Model No.:
26
Material :
27
OPERATIONS/DATE
28
INSTRUMENTS by Purchaser by Supplier
29
Level Switches Level Gauge Pressure Gauge Thermometers
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)
30
Manufacturer
31
Model No.
32
Quantity
33
SPECIFICATIONS
CONST. AGENCY/DATE
34
Painting : Ladder/Platform : (Note 16)
35
Insulation Clips : (Note 15) Wind/Earthquake :
36
Other : Refer to General Information on Sht 6. of 6.
37
38 Notes:
39 13) Deaerator will be located outdoors above grade.
40 14) Supplier scope of supply to include overpressure protection and vacuum breaker devices. Supplier to include
CERTIFIED/DATE
8-Jan-15
42 15) Insulation to be furnished and installed by Others. Supplier to provide insulation clips.
DESIGN CERTIFICATION
43 16) Ladders and platforms scope of supply to be determined and should be in the scope of supplier.
(DESIGN AGENCY)
44 17) Supplier to furnish all instrumentation condition necessary for process control of the deaerator package.
45 18) Supplier to confirm sizes and furnish all connections necessary for proper deaerator function.
46 19) Connections shown on sketch are schematic representations only. The total number/sizes/rating/facing of nozzles and respective
47 locations are to be finalized by the Supplier.
ENGG./DATE
48 20) Supplier to confirm downcomer size and projection, include sizing basis in proposal.
8-Jan-15
XF.Du
49 21) Supplier to furnish a vortex breaker at each main outlet of the Storage Vessel.
50 22) Supplier shall confirm process data and to provide the calculation sheet for Deaeration section drum, Deaerator storage drum.
51 23) Deaerator shall still be designed for 100% cold demineralized water (34 C) makeup at the worst case scenario.
IS COVERED, FOR ALL APPROVAL
DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.
DEAERATOR DAT 3
POWER GENERATION UNIT A10 D VD-068278 OF D
JAZAN SAUDI ARABIA 6
NOZZLE & MANWAY SCHEDULE
SIZE TYPE/
MARK QTY. (IN) SERVICE FACING RATING SCH. REMARK
VESSEL OUTLINE DRAWING PER. NEXT PAGE B1 1 24 Outlet #1 WN/RF 300#
B2 1 24 Outlet #2 WN/RF 300#
NOTES: B3 1 16 Overflow WN/RF 300# vendor to confirm
1. Design Code: ASME Sec. , Div. 1 ED. 2013, and latest Add; U Stamp needed. A1 1 8 Pump Recirc WN/RF 300#
2. Vessel to be manufactured in accordance with 32-SAMSS-004 and applicable addendum. A2 1 10 Aux Steam WN/RF 150#
A3 1 16 Condensate Inlet WN/RF 150#
3. Vendor shall be responsible for detail design and confirm compliance with vessel codes, standard and specification , including the detail strength V 1 2 Vent WN/RF 150# see remark 5,7
calculations, local stress calculations, and if FEA needed. R1/2/3 3 Hold Relief Valve WN/RF 150# see remark 6
by supplier, see
I1 / I2 Hold Hold Downcomer WN/RF 300#
remark 8
4. Weight listed on drawing is only for reference, to be checked and confirmed by the supplier. P1 1 2 Pressure Indicator WN/RF 300#
T 1 2 Temperature Indicator WN/RF 300#
5. Some proposed material are listed, bult these will not relieve Supplier's responsibility to provide the most appropriate material. A4 1 Hold Vacuum Breaker WN/RF 300# by supplier
L1A/B 2 2 Level Transmitter WN/RF 300#
6. External attachments welded directly onto the vessel must be of the same material as the vessel itself. L2A/B 2 2 Level Transmitter WN/RF 300#
L3A/B 2 2 Level Gauge WN/RF 300#
7. Wind per ASCE 7-05 L4A/B 2 2 Level Transmitter WN/RF 300#
Base plate elevation above grade = HOLD P2 1 2 Pressure Transmitter WN/RF 300#
Wind speed = 165km/hr. M1/2 2 24 Manway WN/RF 300# see remark 3
Exposure Category =C DR 1 4 Drain WN/RF 300# see remark 7
Importance Factor=1.15
Occupancy category=IV
Site Class = D 4. THE MINIMUN PROJECTIONS FOR NOZZLES AND MANWAY NECKS IN ACCORDANCE
9. Gaskets for standard flanges: Spiral-wounded gasket, SS316L windings filled with flexible graphite, 316SS outer & inner ring. 6. THE QUANTITY OF THE SAFETY VALVE SHALL BE CONFIRMED BY THE SUPPLIER.
7. THE NOZZLES FOR VENT AND DRAIN SHALL BE WITH BLIND FLANGE, BOLTS/NUTS/GASKETS.
8. THE QUANTITY AND SIZE OF THE NOZZLE SHALL BE DETERMINED BY SUPPLIER.
OPERATING CONDITIONS MATERIALS OF CONSTRUCTION INSULATION FIREPROOFING & PAINTING REQUISITION NO:
INTERNAL PRESSURE: NORMAL: 4 bar (g) COMPONENT ASME NO: INSULATION THICKNESS: 110mm VENDOR:
MAXIMUM: 5.1 bar (g) SHELL: FIREPROOFING THICKNESS: N/A
EXTERNAL PRESSURE: NORMAL: FV bar - BASE MATERIAL SA 516 Gr. 70N SHOP PRIME & PAINT YES(See Note 32) REVISION VALIDATION
MAXIMUM: FV bar - CLADDING OR OVERLAY N/A (SAPCS NO): A10-A-DOC-VE-046373 THIS REVISION NO D IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
SERVICE OTHER BOOT: FIELD PRIME & PAINT N/A REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATION NO:
If other (Specify) - BASE MATERIAL N/A (SAPCS NO): N/A
Demineralized water and condensate D
- CLADDING OR OVERLAY N/A ESTIMATED VESSEL WEIGHTS: DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
NORMAL: 143.9 Deg. C HEADS: SHIPPING: 50000 Kg (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
TEMPERATURE: MAXIMUM 306.2 Deg. C - TYPE 2:1 ELLIPSOIDAL EMPTY: 40900 Kg ENGG./DATE CERTIFIED BY/DATE CONST.AGENCY/DATE OPERATION/DATE BY/DATE
SPECIFIC GRAVITY OF LIQUID: 0.99 - BASE MATERIAL SA 516 Gr. 70N OPERATING: 152200 Kg
- CLADDING OR OVERLAY N/A TEST: 179000 Kg REV.NO. DATE ORIGINATOR REVISION DESCRIPTION
VESSEL TO BE MANUFACTURED IN ACCORDANCE WITH 32-SAMSS-004 AND APPLICABLE ADDENDUM. FLANGES: SA 105 N D 8-Jan-15 XF.Du ISSUED FOR REVIEW
PIPE: SA 106 Gr.B INSULATION SUPPORT: YES
DESIGN CONDITIONS INTERNAL ATTACHMENT CLIPS: SA 516 Gr. 70N FIREFROOFING CLIPS: N/A JOB ORDER/EWO NO. THIS DRAWING IS NOT TO BE USED FOR
ASME DESIGN CODE & EDITION: ASME VIII, Div.1 ED.2013 & latest add; U-Stamp EXTERNAL ATTACHMENT CLIPS: SA 516 Gr. 70N LIFTING LUGS: YES 10-01525-0004 CONSTRUCTION UNTIL CERTIFIED AND DATED
INTERNAL PRESSURE: 12 bar (g) EXTERNAL BOLTING/NUTS: SA193 B7/SA194 2H TAILING LUGS: N/A SAUDI ARABIAN OIL COMPANY
EXTERNAL PRESSURE: FV bar INTERNAL BOLTING/NUTS: N/A TOP DAVIT: N/A PRESSURE VESSEL DATA SHEET DRAWING TYPE DAT
TEMPERATURE: 380 Deg. C FITTING: SA 234-WPB LADDERS & PLATFORMS: YES DEAERATOR
M.D.M.T 10 Deg. C FORGING: SA-266 Gr. 2 LADDERS & PLATFORMS CLIPS: YES JAZAN IGCC POWER BLOCK PROJECT
REINFORCEMENT per code SUPPORTS: GROUNDING LUGS: YES JAZAN SAUDI ARABIA
WIND SPEED 165 km/hr - SKIRT: N/A VACUUM RINGS: YES PLANT NO INDEX DRAWING NUMBER SHT. NO. REV. NO.
ZONE: Ss = 43.5%g, S1 = 12.4%g - SADDLES: SA-283Gr. C HOT BOX: N/A
A10 D VD-068278 4 OF 6 D
EARTHQUAKE: SOIL COEFF: D - LUGS: N/A ANCHOR BOLTS TEMPLATE: N/A
Av: 10%g OTHER (SPECIFY): PIPE SUPPORTS: HOLD
EARTHQUAKE: ACCORD WITH SAES-A-112 NAMEPLATE SUPPORT: YES
GASKETS: PER NOTE 9
CORROSION ALLOWANCE: 3.2 mm NAMEPLATE: YES
RADIOGRAPHY SHELL: FULL HEADS: FULL NOZZLE PROJECTS: 32-SAMSS-004
DEAERATOR
IMPACT TESTING (IT): AS PER CODE INTERNALS
PWHT: YES (IN ACCORDANCE WITH 32-SAMSS-004) Downcomer N/A
( A10-D-1002; A10-D-2002; A10-D-3002;
I. T. TEMPERATURE By Supplier per Code Baffels N/A
A10-D-4002; A10-D-5002)
I. T. ENERGY AVE./MIN: By Supplier per Code Tray 316SS
LOCAL STRESS ANALYSIS IN ACCORDANCE WITH WRC107, WRC297 OR FEA Spray Valve 316SS
3
NOMINAL VOLUME: 130 m
Notes:
1. Reference standard drawing
Top Davit: VEFV1119M
Lifting Lug: By Supplier
Anchor Bolt: AA-036322-001
Vortex Breaker: DD-950005-001-00
Grounding Lug: VEFV1103M
Others: VEFV1100M
REQUISTION NO:
VENDOR:
REVISION VALIDATION
THIS REVISION NO D IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATION NO:
A10 D VD-068278 5 OF 6 D
DEAERATOR
1. SUPPLIER SCOPE IS FIVE (5) COMPLETE DEAERATOR PACKAGES FURNISHED COMPLETE 16. ALL WELDING SHALL BE PERFORMED IN ACCORDANCE WITH CODE REQUIREMENTS
WITH HEATER AND STORAGE VESSELS INCLUDING ALL INTERNALS,INTERNAL AND SAES-W-010 WELDING REQUIREMENTS FOR PRESSURE VESSELS,
ATTACHMENTS, EXTERNAL ATTACHMENTS AND SUPPORTS, MECHANICAL DEVICES, WELDING PROCEDURES INCLUDING PQR's AND WELD MAP SHALL BE SUBMITED
INSTRUMENTATION NOZZLE AND ALL NECESSORY COMPONENTS DESCRIBED HEREIN. FOR ENGINEERING REVIEW, WHICH SHALL BE COMPLETED PRIOR TO
EACH DEAERATOR SHALL BE DESIGNED AND BUILT FOR A MINIMUM SERVICE COMMENCEMENT OF FABRICATION.
LIFE OF 25 YEARS.
17. FABRICATION TOLERANCE IN ACCORDANCE WITH 32-SAMSS-004 PARA. 13.1.
2. ALL DIMENSIONS ARE IN mm FROM REFERENCE TANGENT LINE, UNLESS
OTHERWISE INDICATED. 18. NDE REQUIREMENTS IN ACCORDANCE WITH 32-SAMSS-004 PARA. 14.
3. INSULATION SPECIFICATION REQUIREMENT : IN ACCORDANCE WITH 19. PWHT SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF
A10-A-DOC-VE-046372. SAES-W-010, AND 32-SAMSS-004 PARA.15.
4. VESSEL SHALL BE PROVIDED WITH A MINIMUM OF TWO (2) LIFTING LUGS. 20. PRESSURE VESSELS MANUFACTURED IN ACCORDANCE WITH
32-SAMSS-004 ARE SUBJECT TO VERIFICATION BY THE SAUDI ARAMCO
5. LIFTING LUGS ARE TO BE DESIGNED AND FURNISHED BY VESSEL SUPPLIER. INSPECTOR IN ACCORDANCE WITH SAUDI ARAMCO INSPECTIN FORM 175.
LIFTING ATTACHMENT SHALL BE DESIGNED FOR THE ERECTION WEIGHT OF THE
VESSEL TIMES AN IMPACT FACTOR OF 2.0. 21. HYDRO. TEST SHALL BE CARRIED OUT IN ACCORDANCE WITH
a) PARENT PLATE UNDER LIFTING LUGS SHALL BE 100% ULTRASONICALLY EXAMINED SAES-A-007 AND 32-SAMSS-004, PARA. 16.3.
OVER AREA UNDER LIFTING LUGS PLUS 150mm TO ENSURE PLATE IS FREE FROM DEFECTS.
b) ALL WELDING SHALL BE 100% MT/PT EXAMINED. 22. MANUFACTURING REPAIRS SHALL BE STRICTLY CARRIED OUT
IN ACCORDANCE WITH 32-SAMSS-004, PARA.16.4.
6. FLANGE CONNECTIONS SHALL TERMINATE IN A TRUE HORIZONTAL OR VERTICAL PLANE.
BOLT HOLES SHALL STRADDLE FLANGE CENTERLINE. 23. NAMEPLATE AND STAMPING SHALL BE IN ACCORDANCE WITH THE
APPLICABLE CODE AND REQUIREMENTS OF 32-SAMSS-004,
7. ALL PRESSURE VESSELS SHALL BE DESIGNED AND FABRICATED IN ACCORDANCE WITH NAMEPLATE SHALL BE 3mm MIN. THICKNESS, 304 SS, AND
ASME BOILER AND PRESSURE VESSEL CODE SECTION VIII Div 1, LATEST ADDENDA OR CONTINUOUSLY WELDED TO THE MOUNTING BRACKET ACCORDING
SAUDI ARAMCO APPROVED EQUIVALENT INTERNATIONAL STANDARD. TO PIP VEFV1100. THE MOUNTING BRACKET SHALL BE
SUPPLIER IS RESPONSIBLE FOR DETAILED MECHANICAL DESIGN, AND SHALL CONFIRM CONTINUOUSLY SEAL-WELDED AND POSITIONED SUCH AS NOT TO
COMPLIANCE WITH VESSEL CODES AND PROJECT STANDARDS/SPECIFICATIONS. ALLOW FOR COLLECTION OF MOISTURE OR RAIN.
8. ALL REMOVABLE INTERNALS SHALL BE DESIGNED TO PASS THROUGH THE APPLICABLE 24. PAINTING SHALL BE IN ACCORDANCE WITH SAUDI ARAMCO SPECIFICATION
VESSEL MANWAY. 01-SAMSS-017 AND SAES-H-001.
9. VESSEL MANWAY SHALL BE FURNISHED COMPLETE WITH BLIND, DAVIT/HINGE, GASKETS 25. SHIPPING REQUIREMENTS IN ACCORDANCE WITH 32-SAMSS-004
AND FASTENERS. GASKET TYPE SHALL BE SPIRAL WOUND FLEXIBLE GRAPHITE FILLED PARA. 19. AND PREPARATION FOR SHIPPING, LOADING WITH SUITABLE
WITH 316SS WINDING AND CARBON STEEL OUTER RING & 316SS INNER RING. SUPPORTS FOR TRANSPORTATION TO SITE SHALL BE PROVIDED BY
SUPPLIER. REQUISTION NO:
10. FORMED COMPONENTS INCLUDING HEADS SHALL BE CHECKED VENDOR:
WHETHER HEAT TREATED IS NEEDED OR NOT IN ACCORDANCE 26. VESSEL SHALL BE THROUGHLY CLEANED INSIDE AND OUTSIDE AND SHALL BE
WITH 32-SAMSS-004, PARA13.2.12. FREE OF RUST, SCALE, SLAG, WELD SPATTER AND FOREIGN MATERIAL. REVISION VALIDATION
THIS REVISION NO D IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
11. ALL MATERIALS SHALL CONFIRM TO ASME STANDARDS FOR PRESSURE RETAINING 27. NOZZLE LOADS TO BE DESIGNED PER J95-L-DAT-VE-525361; DESIGN REQUREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATION NO:
PARTS AND ASTM FOR OTHER METALLIC PARTS. BASIS NOZZLE LOADS FOR PRESSURE VESSELS, COLUMNS, AND
SHELL/TUBE TYPE EXCHANGERS. TABLE WITH MAX. ALLOWABLE NOZZLE LOADS DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
12. ALL MATERIALS SHOWN ON THIS DATASHEET SHALL BE FURNISHED AND SHALL BE SHOWN ON THE GENERAL ARRANGEMENT DRAWING. (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
INSTALLED BY VESSEL SUPPLIER UNLESS OTHERWISE NOTED. ENGG./DATE CERTIFIED BY/DATE CONST.AGENCY/DATE OPERATION/DATE BY/DATE
28. SUPPLIER'S SCOPE SHALL BE IN ACCORDANCE WITH THE DOC. NO.
13. MATERIALS FOR PIPING WELD FITTINGS SHALL MEET THE SAME CODE SEP-PGB-ME-SOW-0015. REV.NO. DATE ORIGINATOR REVISION DESCRIPTION
REQUIREMENTS FOR THE PRESSURE COMPONENT MATERIAL D 08-Jan-15 XF.Du ISSUED FOR REVIEW
SPECIFICATION USED FOR PLATE, PIPE OR FORGINGS. 29. EXTERNAL ATTACHMENTS DIRECTLY WELDED ON TO THE VESSEL
MUST CHOOSE THE SAME MATERIAL AS THE VESSEL SHELL. JOB ORDER/EWO NO. THIS DRAWING IS NOT TO BE USED FOR
14. M.A.W.P. SHOWN ON THE NAMEPLATE IS BASED ON THE NOMINAL 10-01525-0004 CONSTRUCTION UNTIL CERTIFIED AND DATED
THICKNESS, EXCLUSIVE OF CORROSION ALLOWANCE ON DESIGN 30. ALL EQUIPMENT BOLT/ NUT TO BE COATED AS PER SAES-H-001 "G" SAUDI ARABIAN OIL COMPANY
TEMPERATURE, AND SHALL NOT BE LIMITED BY FLANGE RATINGS. FASTENERS. FLUOROPOLYMER COATING TO BE APPLIED WITH PRESSURE VESSEL DATA SHEET DRAWING TYPE DAT
09-SAMSS-107. DEAERATOR
15. ALL BODY/SADDLE MATERIAL,FLANGES, FORGINGS, FITTINGS AND PIPING JAZAN IGCC POWER BLOCK PROJECT
FOR USE OF INTERNALS SHALL BE PURCHASED FROM SAUDI ARAMCO 31. FLANGED SHALL BE RAISED FACE, AND HAVE FACING SURFACE JAZAN SAUDI ARABIA
APPROVED MANUFACTURERS. ROUGHNESS OF 125~250 AARH. PLANT NO INDEX DRAWING NUMBER SHT. NO. REV. NO.
A10 D VD-068278 6 OF 6 D
32. THE EXTERIOR SURFACE OF VESSEL SHALL BE PAINTING WITH APCS-11C
ACCORDING TO THE SPECIFICATION OF A10-A-DOC-VE-046373.
DEAERATOR