DATA SHEET
DEAERATOR PUMPS
Date

POWER GENERATION UNIT


Description
Prep

DAT
DWG. TYPE

SAUDI ARABIA
Chk
A10-G-1002A/B

Contains Confidential Information of Saudi Aramco


A10
POWER GENERATION

PLANT NO.
SAUDI ARABIAN OIL COMPANY

MECHANICAL DATASHEET

G
DEAERATOR PUMPS (BLOCK1)

INDEX
Appvd
JAZAN IGCC POWER BLOCK PROJECT
ATTACHMENT #4 DATA SHEET

PM

DRAWING NO.

VE-068279
SHT.NO
SAPMT

1 of 7
A
REV.NO.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Saudi Aramco 2741-M-ENG (11/2010)

SAUDI ARABIAN OIL COMPANY

UNTIL CERTIFIED AND DATED


THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
NOTE: BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2

INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004

PURCHASERS REFERENCES SITE CONDITIONS


INDOOR OUTDOOR UNDER ROOF
APPLICABLE TO: PROPOSALS PURCHASE AS BUILT ON SHORE COASTAL OFF SHORE
0

PUMP MFR HYOSUNG GOODSPRINGS INC ELECTRICAL AREA Note 2 , DIV. , GROUP
REVISION DESCRIPTION

SIZE & TYPE SUC.12" X DIS. 8, KDR250-630

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
SERIAL NO. 1500777-001~002 PERFORMANCE DATA
DRIVER TYPE INDUCTION MOTOR PERFORMANCE
THIS DATA SHEET COVER 2 PUMP(S) RATED SPEED RPM 1788
PUMP MARK NO(S). -G- , -G- DRIVER NAME PLATE POWER RATING kW 500
-G- , -G- RPM 1780
PUMPS OF IDENTICAL TYPE & SIZE IN OPERATION 100% 120%
10-01525-0004

MIN. CONT.
NORMAL
18-May-2015

-G- , -G- PERFORMANCE AT STABLE


FLOW OF RATED
FLOW CAPACITY
DATE

-G- , -G-
DRIVER DATA SHEET A10-P-DAT-VE-288619 TOTAL DIFF. HEAD m 185.8 171.2 167 155.1
JOB ORDER/EWO NO.

GEAR UNIT DATA SHEET EFFICIENCY % 50.9 68.2 69.2 69.6


LUBE OIL SYST DATA SHEET REQUIRED POWER kW 309.6 423.8 448.3 496.6
REV. NO.

SAFETY INSTRUCTION SHEET NPSH REQ'D FOR:


00

LCC EF $/kW 3% H 1st STAGE ON H2O m 4.3 4 4.1 4.6


40,000 HRS LIQ'D PUMPED m
SERVICE
BY/DATE
OTHER

PUMP FUNCTION Deaerator Pumps (Block 1)


CONTINUOUS INTERMITTENT STANDY BY SHUT-OFF HEAD AT ACTUAL IMP. DIAM. m 189.2
ATTENDED UNATTENDED AT MAX. IMP. DIAM. m 200.6
INDIVIDUALLY IN SERIES IN PARALLEL CAPACITY AT END OF CURVE m3/h 889.7
OPERATIONS/DATE

UPSTREAM OF PUMP NO(S) -G- TOT.DIFF. HEAD AT END OF CURVE m 155.1

-G- RATIO. SHUT-OFF HEAD/RATED HEAD 113.30%


REVIEW FOR KEY DRAWINGS

DOWNSTREAM OF PUMP NO(S) RATIO. END OF CURVE CAPACITY/RATED CAP. 120%


REQUIRED (SAUDI ARAMCO)

-G-
-G- MINIMUM CONTINUOUS STABLE FLOW m3/h 338
MINIMUM CONTINUOUS THERMAL FLOW m3/h 338
LIQUID CHARACTERISTICS MAXIMUM OPERATING TIME AT SHUT-OFF s0
LIQUID PUMPED water contain ammonia (0-2ppm) TDS 0 mg/L FIRST CRIT. SPEED; DRY RPM 2314
NST. AGENCY/DATE

MIN. FLOW TEMPERATURE O


C 146.7 FIRST CRIT. SPEED; WET RPM 2136
MAX. FLOW TEMPERATURE O
C 152.6 MAX. ALLOWABLE SPEED RPM N/A
RELATIVE DENSITY AT MAX. FLOW TEMP. 0.915 MAX. POWER FULL CURVE ACTUAL IMP.DIAM. kW 496.6
VISCOSITY AT MAX. FLOW TEMP. mpa.s 0.18 POWER AT SHUT-OFF HEAD kW 207.4
CON

VAPOR PRESSURE AT MIN.


MIN

FLOW TEMP. bar(abs) 4.355 PERFORMANCE WITH MAX. AND


V.P. AT MAX. FLOW TEMP. bar(abs) 5.102 MIN. IMPELLER DIAMETERS
TSS NONE mg/L UNKNOWN MAX. MIN.
CERTIFIED/DATE

18-May-2015
B. Anders

CHARACTER OF SOLIDS: PULPY GRITTY HARD SOFT TOT.DIFF. HEAD AT RATED m 181.3 N/A
DESIGN CERTIFICATION

GAS IN FLUID: NONE VOL. % UNKNOWN EFFICIENCY AT RATED CAPACITY % 69.2 N/A
(DESIGN AGENCY)

PRINCIPAL CORROSIVES: N/A REQUIRED POWER AT RATED CAP. kW 484 N/A


pH 7~10 CI N/A mg/L MAX. REQUIRED POWER FULL CURVE kW 596.6 N/A

INTERMEDIATE TRANSMISSION
OPERATING CONDITIONS
GEAR BOX RATIO
18-May-2015
ENGG./DATE

CAPACITY NORMAL m3/h 674 HYDR. COUPL. SPEED RANGE


Y. Wang

% % OF DRIVER SPEED
RATED m3/h 741.4 CONSTRUCTION DATA
RATED TOTAL DIFFERENTIAL HEAD m 167 PUMP TYPE
NPSH AVAILABLE AT SUCTION FLG. HORIZONTAL (BET. BRGS) OVERHUNG
AT MAX FLOW RATE CASE m 8.906 VERT. IN-LINE INTEGRAL SHAFT
AT 120% OF RATED CAPACITY m 8.882 CASING MOUNT: CENTERLINE FLANGE CENTERLINE
1 1 1
IS COVERED, FOR ALL APPROVAL

VISC. CORR. FACTOR CQ; CH; CE FOOT


AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER

SUC.PRESSURE AT MAX FLOW RATE CASE bar(abs) 5.156 VERT. IN-LINE IN-LINE CASE SUPPORTED
DIS.PRESSURE AT MAX FLOW RATE CASE bar(abs) 20.21 CASING SPLIT AXIAL RADIAL
DIFF. PRE. AT MAX FLOW RATE CASE bar 15.054 CASING TYPE DOUBLE VOLUTE SINGLE VOLUTE
MAX. SUCT. PRE. AT SHUT-OFF bar(abs) 14.3 DIFFUSOR STAGGER
REVISION VALIDATION

MAX. DIS. PRE. AT SHUT-OFF (NOTE 22) bar(abs) 34.6 SELF PRIMING YES NO
DRAWING COMPLETION CERTIFICATE NO.

DIR. OF ROT. CCW CW


(VIEWED FROM DRIVER)
PUMP NOZZLES
SIZE RATING FACING LOCATION
00

SUCTION 12" 300# Note 1 RF TOP


DISCHARGE 8" 300# Note 1 RF TOP
THIS REVISION NO.

DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.

DEAERATOR PUMPS DAT


POWER GENERATION UNIT A10 G VE-068279 2 of 7 00
JAZAN SAUDI ARABIA
EKRD/2741-M-1-1110.XLS
Saudi Aramco 2741-M-ENG (11/2010)

SAUDI ARABIAN OIL COMPANY

THIS REVISION IS NOT TO BE USED


FOR CONSTRUCTION UNTIL
CERTIFIED AND DATED
CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
NOTE: BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2
REVISION DESCRIPTION

INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004


CONSTRUCTION DATA (CONT'D) CONSTRUCTION DATA (CONT'D)
0

FORCES AND MOMENTS STUFFING BOX DATA

SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
/ ALLOWABLE FORCES AND MOMENTS
TOP NOZZLE SIDE NOZZLE END NOZZLE EACH INBOARD / OUTBOARD

Fx N Fx N Fx N Mx N.m INSIDE DIAMETER mm 160


Fy N Fy N Fy N My N.m DEPTH mm 120
18-May-2015

Fz N Fz N Fz N Mz N.m DISTANCE FACE OF STUFFING BOX


DATE

10-01525-0004

MISC CONNECTIONS QTY. SIZE TYPE FLANGE TO NEAREST OBSTRUCTION mm


JOB ORDER/EWO NO.

LUBE OIL INLET


LUBE OIL OUTLET
SEAL LIQUID INLET IMPELLER DATA
REV. NO.

SEAL LIQUID DRAIN FIRST FOLLOW


00

CASING DRAIN(S) 2 3/4" V/V WITH FLANGE NUMBER OF STAGES 1(ONE) STAGE STAGE

VENTS / ACTUAL DIAMETER mm 604


COOLING WATER 2 3/4" / MAXIMUM DIAMETER mm 622
STUFFING BOX / MINIMUM DIAMETER mm 495
BY/DATE
OTHER

BALANCE DRUM SINGLE / DOUBLE SUCTION D


2
DRAIN & VENT INDIVIDUALLY PIPED WITH BLOCK VALVES TO TERMINATE / EYE AREA IMPELLER cm 557x2
O
AT EDGE OF BASE PLATE IN COMMON YES NO VANE ANGLE AT IMP. EXIT 27.5
FLANGE RATING 3/4" in CLASS #300 / NUMBER OF VANES 5
ACTUAL PERIPHERAL SPEED m/s 54.1
OPERATIONS/DATE

PRESSURES MAX.ALLOW.PERIPH.SP'D AT FLOW TEMP. m/s 135


MAX. ALLOW. / PATTERN NUMBER
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

WORK. PRESS. HYDROST.


/ PRECISION CAST YES - NO YES
TEST PRESS
O
/ PRESSURES AT 150 C / CUT WATER DIAMETER mm 677
CASE bar(g) 40 60 SPECIFIC SPEED 103.3m3/m,m,rpm
JACKETS bar(g) / SUCTION SPECIFIC SPEED AT 3% H 1477.9 m3/m,m
CONST. AGENCY/DATE

COILS bar(g) WIDTH. IMPELLER DISCH. mm 40


DUAL MECH. UNDER / OVER FILING / V-CUT YES / NO NO
SEAL bar(g) WEARING RINGS:
IMPELLER YES NO
SHAFT DATA CASE YES NO
SHAFT DIAMETER AT MECH. SEAL mm 90 CLEARANCE INBOARD mm

SHAFT DIAMETER AT BEARINGS mm 80 OUTBOARD mm


RTIFIED/DATE

18--May-2015

SHAFT DIAMETER AT 1ST STAGE IMPELLER mm 104 1st STAGE IMPELLER INLET
B. Anders

BEARING SPAN mm 1315


TION

STATIC SHAFT DEFLECTION mm 0.028


Y)
CERT
DESIGN CERTIFICAT
(DESIGN AGENCY

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF S
B

SHAFT SEALING
PACKED STUFFING BOX PACKING MAT'L.
PROVIDED WITH LANTERN RING: YES NO
18-May-2015
ENGG./DATE

SEALING ARRANGEMENT THROUGH SEALING


Y .Wang

DEAD ENDED
FLUSH WITH LIQUID PUMPED GREASE p

FOREIGN LIQUID BLEED OFF


MECHANICAL SEAL API CODE C2A1A 23/61 (Note 10) h

/ MAKE EAGLE BURGMANN


/ MANUFACTURER MAT'L CODE AQ2KMG
/ MODEL H75VNP
/ API CODE MAT'L 3RD LETTER T
Dh1

Dh2
Dsl
Dp

4TH LETTER F
d
IS COVERED, FOR ALL APPROVAL

AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER

5TH LETTER N
PIPING FOR PRIMARY SEAL API FIG. D-2 PLAN #23 Dp = 266.7 mm
PIPING FOR THROTTLE BUSHING OR Dsl = 114 mm (IF APPLICABLE)
REVISION VALIDATION

AUXILIARY SEAL API FIG. D-3 PLAN #61 Dh1 = 124 mm


COOLING WATER PIPING, API FIG. D-4 PLAN #K Dh2 = 140 mm
DRAWING COMPLETION CERTIFICATE NO.

CYCLONE SEPARATOR YES NO d = 104 mm


FLOW ORIFICE IN SEAL FLUSH SUPPLY LINE YES NO p = 17 DEGREES
SEAL LEAKAGE PIPING WITH ORIFICE YES NO h = 33.3 DEGREES
BUFFER LIQUID SYSTEM YES NO
METHANOL DRIP SYSTEM YES NO
00

/ REQUIRED: PRESSURE bar(g); FLOW m3/h

CARTRIDGE DESIGN YES NO


THIS REVISION NO.

DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.

DEAERATOR PUMPS DAT


POWER GENERATION UNIT A10 G VE-068279 3 of 7 00
JAZAN SAUDI ARABIA
EKRD/2741-M-2-1110.XLS
Saudi Aramco 2741-M-ENG (11/2010)

SAUDI ARABIAN OIL COMPANY


CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS

UNTIL CERTIFIED ANDDATED


THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
NOTE: BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2
INDICATES INFORMATION TO BE COMPLETED BY BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004
CONSTRUCTION DATA (CONT'D) CONSTRUCTION DATA (CONT'D)
BEARINGS AND LUBRICATION COUPLING
BEARING TYPE RADIAL THRUST / MAKE THOMAS MODEL 71 SERIES SIZE 71-462-0055
0
REVISION DESCRIPTION

SLEEVE SUPPLIED BY: PT COUPLING


ANTI-FRICTION TYPE THOMAS-71

NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
TILTING PAD DIAPHRAGM DISC PACK
LUBRICATION METHOD RADIAL THRUST RIGID ADJUSTABLE
GREASE CLOSE COUPLED
RING-OIL CONSTANT LEVEL ELASTOMERIC
/ LUBRICATOR, MAKE HYDRAULIC FIT KEYED
OIL BATH WITH EXT'L CIRCULATION SPACER: YES, 300 mm NO
18-May-2015

FORCED FEED COUPLING GUARD PARTIALLY ENCLOSED COMPLETELY ENCLOSED


10-01525-0004
DATE

OIL MIST PUMP SHAFT END CYLINDRICAL TAPERED


JOB ORDER/EWO NO.

LUBE OIL PIPING TO AND MOUNT COUPLING HALF: PUMP YES NO


FROM BEARINGS YES NO DRIVER HALF YES NO. IF SHIPPED TO DRIVER
LUBE OIL PIPING UP TO L.O. SYSTEM YES NO PILOT BORED COMPLETELY MACHINED
REV. NO.

TERMINATION WITH FLANGED


00

CONNECTIONS AT RADIAL COUPLING BASE PLATE


PLANE YES NO
SIGHT FLOW INDICATOR IN EACH BASE PLATE OIL FIELD SKID
BY/DATE
OTHER

RETURN BRANCH MAKE MODEL SUPPLIED BY Pump Vendor


THRUST BEARING LOADS: TO DRIVER GEAR PUMP
MAX. ALLOWABLE AXIAL FORCE: N L.O. AND/OR S.O. SYSTEM ON BASE OFF BASE
DESIGN AXIAL FORCE: 3335 N DESIGNED FOR INSTALLATION ON:
OPERATIONS/DATE

CONCRETE FOUNDATION STEEL PLATFORM


LUBRICANTS DRILLED FOR DRIVER YES NO GEAR YES NO
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

BEARING LUBRICANT ISO VG 46 HORIZONTAL ALIGNMENT JACKSCREWS YES NO


OIL PER 26-SAMSS-045 GREASE PER 26-SAMSS-054

FLOW OR SUPPLY HEAT MAX. OIL MATERIALS OF CONSTRUCTION


CAPACITY PRESSURE REMOVAL OUTL. TP. MATERIALS TO BE IN ACC. WITH CODE HSX (NOTE 14)
O
m3/h bar(g) Kj C OF STD. DRAWING AD-036821
CONST. AGENCY/DATE

INB. BRG. 1.6L VENDOR TO COMPLETE FOLLOWING MAT'L LISTING


OUTB. BRG. / 1 CASING ASTM A487 CA6NM
THRUST BRG. 1.6L 2 IMPELLER(S) ASTM A487 CA6NM
3 CASE WEAR RINGS ASTM A276 410
4 IMPELLER WEAR RINGS ASTM A276 410
TOTAL 3.2L 5 SHAFT ASTM A276 410

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. N
LUBE OIL SYSTEM SUPPLIED BY: PUMP VENDOR 6 SHAFT SLEEVES ASTM 316SS
CERTIFIED/DATE

OTHER 7 THROAT BUSHINGS ASTM A276 410


18-May-2015
B. Anders

IN ACCORDANCE WITH DATA SHEET FORM 8004-ENG 8 INTERSTAGE SLEEVES ASTM


DESIGN CERTIFICATION

YES, DRAWING NO. NO 9 INTERSTAGE BUSHINGS ASTM


(DESIGN AGENCY)

10 LANTERN RING (PACKED PUMPS) ASTM


11 GLAND / MECH. SEAL FLANGE ASTM 316SS
COOLING 12 BEARING BRACKETS ASTM SPCH2
BEARING COOLING 13 1 NON-WETTED STUDS / NUTS ASTM
NON-CIRCULATING SYSTEM BY: 2 WETTED FASTENERS ASTM
18-May-2015
ENGG./DATE

SHAFT MOUNTED FAN JACKETED BEARING PIPING: PIPE / FITTINGS ASTM 316L SS
Y. Wang

14
COILS IN BEARING HOUSING 15 BASE PLATE ASTM A36
16 MECH. SEAL SPRINGS ASTM HASTELLOY-C
EXTERNAL CIRCULATING SYSTEM 17 MECH. SEAL OTHER METAL ASTM 316L SS
OIL COOLING BY: 18 ASTM
LIQ. PUMPED FOREIGN LIQ. AIR NONE 19 ASTM
STUFFING BOX COOLING YES NO
IS COVERED, FOR ALL APPROVAL

PEDESTAL COOLING YES NO NOISE SPECIFICATION


AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER

COOLING PIPING FOR


BEARINGS STUF. BOX PEDESTALS SEAL COOLER
IN ACCORDANCE WITH API-610. FIG. D-4.PLAN #K MAXIMUM ALLOWABLE SOUND LEVEL
BY PURCHASER AT 1 m DISTANCE 85 dBA
REVISION VALIDATION

COOLANT DATA MANUFACTURER GUARANTEED MAXIMUM


PUMP 83.1 dBA
DRAWING COMPLETION CERTIFICATE NO.

BRG STUF PEDES- SEAL


HSG BOX TAL COOLER DRIVER 85 dBA
TOTAL FLOW m3/h 2 3 OTHER dBA
INLET PRESS. bar(g) 3 3 COMPLETE TRAIN 87.1 dBA
00

O
TEMP. INLET C
O
TEMP. OUTLET C
COOLING MEDIUM
THIS REVISION NO.

DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.

DEAERATOR PUMPS DAT


POWER GENERATION UNIT A10 G VE-068279 4 of 7 00
JAZAN SAUDI ARABIA
EKRD/2741-M-3-1110.XLS
Saudi Aramco 2741-M-ENG (11/2010)

SAUDI ARABIAN OIL COMPANY

UNTIL CERTIFIED AND DATED


THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
NOTE: BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2

DI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
REVISION DESCRIPTION

O INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004


UTILITIES INSPECTION AND TESTS
0

OBSER'D
CERT'D
WITN'D

NONE
ELECTRIC POWER AVAILABLE VENDOR'S STANDARD SHOP TEST
AC PHASE AS FOLLOWS
VOLTS
DC HZ HYDROSTATIC TEST
MAIN ELECTRIC DRIVER AC 4000 3 / 60 WATER KEROSENE
CONTROLS AND PROTECTION AC 460 3 / 60 RUNNING TEST
18-May-201

DC 24 PERFORMANCE TEST
10-01525-0004
DATE

JOB ORDER/EWO NO.

AIR AVAILABLE MEASURE DP ACROSS STUFFING BOX


barg NPSH TEST
CONTROLS AND PROTECTION 6 DISMANTLING
RADIOGRAPHIC INSPECTION IMPELLER
REV.NO.

DYE PENETRANT EXAMINATION IMPELLER


00

AVAIL INLET OUTLET REQ'D DYNAMIC BALANCE IMPELLER(S)


AVAIL COOLING barg O
C O
C O
C DYNAMIC BALANCE ROTOR
WATER 6.5 37 <47 DYNAMIC BALANCE COUPLING
BY/DATE
OTHER

VIBRATION, MEASUREMENTS
WELL WATER TREATED WATER SEA WATER TESTS TO BE CARRIED WITH:
ONCE THROUGH SYSTEM CLOSED LOOP SYSTEM ACTUAL DRIVER MANUFACTURER'S DRIVER
AT RATED SPEED DERATED SPEED: RPM
INSTRUMENTATION & CONTROLS
OPERATIONS/DATE

DRAWINGS AND OTHER DATA


TEMPERATURE RADIAL THRUST CASING
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

MONITORING BEARINGS BEARINGS THERMOWELL MANUFACTURER'S DRAWING OR DOCUMENT

YES REQUIRED
PROVISIONS ONLY YES NO
DIMENSIONAL DRAWING OF
CONST. AGENCY/DATE

O
ALARM SETTING C 95 95 COMPLETELY ASSEMBLED UNIT
O
SHUTDOWN SETTING C 100 100 OPER. & MAINT. INSTRUCTIONS
CROSS SECT. DRW. WITH PART NO'S.
VIBRATION / DISPLACEMENT MONITORING MECHANICAL SEAL DRAWING
BILLS OF MATERIALS
POSITION RADIAL BRG'S THRUST BRG. BRG. HSG COMPLETED PUMP DATA SHEET
TYPE PROXIMITY PROXIMITY SEISMIC AUXILIARY PIPING DWG.
CERTIFIED TEST CURVE & DATA
YES RECOMMENDED SPARES LIST
PROVISIONS ONLY INSTR WIRING DIAGRAM
INSTR.

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUD
CERTIFIED/DATE

18-May-2015

SPEED TORQUE CURVE


B. Anders

ALARM / SHUTDOWN COLD ALIGNMENT CURVE


DESIGN CERTIFICATION

SETTING: m P-P / DATA L. & T. VIBR. ANALYSIS


(DESIGN AGENCY)

mm/s RMS /
/
SEISMIC PNEUMATIC MISCELLANEOUS
ELECTRICAL
18-May-2015

PROXIMITY PAINTING
ENGG./DATE

Y. Wang

SHAFT SEAL LEAKAGE CONTROL: YES NO


ELECTRICAL PNEUMATIC BUYER'S PAINT A10-A-DOC-VE-046373
/ PRES. SWITCH MAKE MODEL VENDOR'S STANDARD:
/ PRESSURE SETTING *SHUTDOWN* bar(g)
LEVEL SWITCH MAKE MODEL
IS COVERED, FOR ALL APPROVAL

AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER

/ TIME DELAY SETTING CONTR.ORIFICE mm SPECIFICATION

MASSES PUMPS TO BE IN ACCORDANCE WITH:

31-SAMSS-004
/ PUMP kg 1880 ASME B 73.1 ASME B 73.2
DRAWING COMPLETION CERTIFICATE NO.
REVISION VALIDATION

PUMP ROTATING ASSEMBLY kg


CASING (UPPER HALF) kg
BASEPLATE kg 3100
COUPLING kg
DRIVER kg 4000
00

DRIVER ROTATING ASSEMBLY kg


TOTAL MASS kg 9180
THIS REVISION NO.

DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.

DEAERATOR PUMPS DAT


POWER GENERATION UNIT A10 G VE-068279 5 of 7 00
JAZAN SAUDI ARABIA
EKRD/2741-M-4-1110.XLS
SAUDI ARABIAN OIL COMPANY

UNTIL CERTIFIED AND DATED


THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
REVISION DESCRIPTION

Engineering Notes:
0

1. Nozzle rating is estimated, need to be confirmed by Pump vendor after Hazop action. And the Nozzle load shall take 3 times of API 610-10th table 4.
2. Equipment will be located in Unclassified Area.
3. Those are operation flow only, margin of +10% of operation flow needs to be considered by pump vendor at pump selection and design.

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
4. The same pump tag numbers with A, B suffix will be operated 2100%, one for operation and the other for standby.
5. Vendor to fill the blank of this data sheet, as well as datasheets attached in SEP-PGB-ME-REQ-0003-002 completely.
6. Pump shall be designed as per 31-SAMSS-004 and A10-A-DOC-VE-068274.
7. Electric motor datasheet shall refer to A10-P-DAT-VE-288619, and electric motors shall be in accordance with 17-SAMSS-502.
18-May-2015

8. "Operating Conditions: Each Pump" shown in below table represents operating conditions for the Deaerator Pump.
10-01525-0004
DATE

9. The inspection & testing requirement shall be as per SAUDI ARAMCO form 175.
JOB ORDER/EWO NO.

10. Mechanical Seal and support system shall be in accordance with 31-SAMSS-012. Mechanical seal configuration is 1CW-FX, Category 2,
Arrangement 1, Seal Type A.
11. Machinery proection system shall be in accordance with 34-SAMSS-625.
REV. NO.

12. Electrical installations shall be in accordance with 17-SAMSS-515, and all instrumentations shall be in accordance with 34-SAMSS-831.
00

13. All auxiliary piping design, joint fabrication, examination and inspection shall comply with 01-SAMSS-017.
14. Pump material shall be according to standard Saudi Aramco Drawing AD-036821-001.
15 PMI (Positive Material Identification) testing shall be inaccordance with SAES-A-206.
16. Copper or copper alloys shall not be used for any components exposed to the atmosphere.
BY/DATE
OTHER

17. Refer to project design data (Document No. A10-A-DOC-VE-911677) for available utilities and site data.
18. Refer to A10-A-DOC-VE-046373, SAES-H-001 and SAES-H-101V for coating selection and application.
19. The coolers for seal flushing system if needed will be water-cooled type, the utility consumption of which should be provided by vendor.
20. The vibration, position , temperature detectors&transmittals on pumps and motors shall match Bently Nevada 3500. And extension cables and junction
boxes should be within vendor's scope.
OPERATIONS/DATE

21. The cooler for the seal flush plans 23 shall be sized to maintain the flush fluid at or below 60 .
22. Vendor to note that the shutoff pressure shall NOT exceed +25% difference pressure at rated flow rate .
23. Estimated hydraulic power is 310 kW.
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

24 Motor rated power to be at least 110% of pump SBHP or pump rated impeller end of curve which is less.
CONST. AGENCY/DATE
CERTIFIED/DATE

18-May-2015
B. Anders
DESIGN CERTIFICATION
(DESIGN AGENCY)

18-May-2015
ENGG./DATE

Y. Wang
CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER DRAWING

OPERATING CONDITIONS: EACH PUMP


IS COVERED, FOR ALL APPROVAL AND

CASE 2 CASE 6 CASE 9 CASE 14 CASE 10a Remark


SUCTION PRESSURE bara 5.156 5.799 5.799 5.801 5.798
DISCHARGE FLOW m3/h 674 389 424 125 449 Note 3
TDH m 167 148.3 156.3 151 149.4
SUCTION TEMP C 146.7 151.8 151.8 151.8 151.8
REVISION VALIDATION

NPSHa m 8.906 8.962 8.960 8.972 8.959


COMPLETION CERTIFICATE NO.
THIS REVISION NO 00

DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.

DEAERATOR PUMPS DAT


POWER GENERATION UNIT A10 G VE-068279 6 of 7 00
JAZAN SAUDI ARABIA
Contains Confidential Information of Saudi Aramco
Saudi Aramco 7305-ENG (11/2010)

SAUDI ARABIAN OIL COMPANY

UNTIL CERTIFIED AND DATED


THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
EQUIPMENT NOISE DATA SHEET
REVISION DESCRIPTION

O. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
GENERAL INFORMATION
0

Project Designation: Jazan IGCC Project Inquiry/Purchase Order No.:


Location: Jazan Saudi Arabia Manufacturer:
Equipment Type: Deaerator Pumps (Block 1) Model No.:
Equipment Serial No.:
18-May-2015

10-01525-0004
DATE

JOB ORDER/EWO NO.

PURCHASER'S REQUIREMENTS
REV. NO.

This form shall be completed for each piece of equipment (or integrated unit) that is likely to generate noise in excess of 85
00

dBA at a distance of one meter. If the noise level is greater than 90 dBA, the cost of special design and/or acoustic treatment
should be supplied. Measurements are to be made in accordance with ANSI S1.13 and at full design load, unless otherwise
indicated. For rotating electric machinery, use points defined in IEEE Standard 85.
BY/DATE
OTHER

OPERATIONS/DATE

Also measure at: 50% load 120% load Other load


REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

SUPPLIER, MANUFACTURER OR VENDOR INFORMATION


Sound Pressure Level, dBA

Standard Design: Special Design: With Acoustic Treatment:


CONST. AGENCY/DATE

Octave Band Sound Pressure Levels, dBA (Ref. 0.02 mPA)


(Supplier's Guaranteed Maximum Sound Pressure Level at One Meter)

Center Frequency Standard Special With Acoustic


Octave Band

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO
(Hz) Design Design Treatment
CERTIFIED/DATE

(Hz)
18-May-2015
DESIGN CERTIFICATION

B. Anders

63
(DESIGN AGENCY)

20 - 75
75 - 150 125
150 - 300 250
500
18-May-2015

300 - 600
ENGG./DATE

Y. Wang

600 - 1200 1000


1200 - 2400 2000
2400 - 4800 4000
4800 - 9600 8000
IS COVERED, FOR ALL APPROVAL

AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER

Description of Special Design: Added Cost:


REVISION VALIDATION

Description of Acoustic Treatment: Added Cost:


DRAWING COMPLETION CERTIFICATE NO.

Supplier, Manufacturer or Vendor:


Represented by: Title:
Signature: Date:
00
THIS REVISION NO.

DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.

DEAERATOR PUMPS DAT


POWER GENERATION UNIT A10 G VE-068279 7 of 7 00
JAZAN SAUDI ARABIA
EKRD/7305-1110.XLS
REVISION VALIDATION DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS REV. NO. DATE REVISION DESCRIPTION
OTHER
THIS REVISION NO. D IS COVERED, FOR ALL APPROVAL (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
D 8-Jan-15 ISSUED FOR REVIEW
AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER ENGG./DATE CERTIFIED/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE

DRAWING COMPLETION CERTIFICATE NO. XF.Du B.Anders JOB ORDER/EWO NO. THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
08-Jan-15 08-Jan-15 10-01525-0004 UNTIL CERTIFIED AND DATED

JAZAN
Saudi Aramco 2616-ENG (11/2010)

A
B
C
D

DEAERATOR
Rev

DATA SHEET
Date

POWER GENERATION UNIT


8-Jan-15

9-Sep-14
7-Dec-14
10-Oct-14

Description
Issued for Review
Issued for Review
Issued for Review
Issued for Review

Prep
XF.Du
XF.Du
XF.Du
XF.Du

DAT

SAUDI ARABIA
DWG. TYPE
Chk
LY.Dun
LY.Dun
LY.Dun
LY.Dun
DEAERATOR

A10
PLANT NO.
POWER GENERATION
A10-D-4002; A10-D-5002

SEPCO Revision History (to be removed after IFP issue)


EQUIPMENT DATA SHEET
SAUDI ARABIAN OIL COMPANY

D
INDEX
Appvd
HY.Liang
HY.Liang
HY.Liang
HY.Liang
A10-D-1002; A10-D-2002; A10-D-3002;

JAZAN IGCC POWER BLOCK PROJECT

PM

DRAWING NO.
B.Anders
B.Anders
B.Anders
B.Anders

VD-068278
6
1
OF
SHT.NO
SAPMT

D
REV.NO.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
SAUDI ARABIAN OIL COMPANY
DEAERATORS A10-D-1002; A10-D-2002; A10-D-3002; A10-D-4002; A10-D-5002

UNTIL CERTIFIED AND DATED


THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
1 ISSUED FOR: PROPOSAL PURCHASE
2 DESIGN, MANUFACTURE & TESTING SHALL CONFORM TO SPECIFICATION
3 INFORMATION TO BE COMPLETED : BY PURCHASER BY MANUFACTURER BY PURCHASER OR MANUFACTURER
REVISION DESCRIPTION
4 GENERAL SPECIFICATION
ISSUED FOR REVIEW 5 Manufacturer:  Water Storage Capacity (min.) : (Note 1)
6 Model No.:  Empty to Low Level :
7  Quantity : Five (5) Deaerator Packages  Low Level to Normal Water Level :
8  Area Classification : Unclassified  Design Pressure (ASME BPV Sect.VIII, Div.1)
9  Heater : Horizontal 12 (barg) and full vacuum @ 380 (C)
10  Storage : Horizontal  MDMT: 10C
11 OPERATING CONDITIONS
Flow Rate (Note 1) Temperature
8-Jan-15

12 Enthalpy

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
DATE

Service Pressure
10-01525-0004

13 Normal flow Design flow


JOB ORDER/EWO NO.

14 Units (kg/h) (kg/h) (C) (kJ/kg) (barg)


15 Condensate Inlet 374256 661644 143.9 (Norm),133 (Design) 605.9 (Norm), 559.1(Design) See Note 12
Inlet
16
REV. NO.

17 Steam Inlet 5578 22780 306.2 3075 5.1


D

18
19 Outlet 379132 683744 152 640.6 4.0

20
Outlet Vent 380 684 152 2747
21
BY/DATE
OTHER

22
23
24
Pump Kickback Hold
25
Sparger by supplier
26
OPERATIONS/DATE

Deaerator Drain
27
Overflow by supplier
28
V.B.Vent
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

29
R.V. by supplier
30
31
32
CONST. AGENCY/DATE

33
34
35
36
37
38 Notes:
39
CERTIFIED/DATE

40 1) A design margin of 10% shall be added to the Design flow specified above to size the deaerator. Supplier to provide storage capacity for
08-Jan-15
B.Anders

41 5 minutes based on the Design flow.


DESIGN CERTIFICATION

42 2) Steam inlet source is from Low pressure (LP) / Auxiliary steam header
(DESIGN AGENCY)

43 3) Effluent Guarantee : Oxygen shall be reduced to less than 0.005 ml/l (7ppb).
44 Carbon dioxide shall be zero in effluent as measured by APHA.
45 4) Both heater and Storage Vessels shall be (service)post weld heat treated to relieve residual stresses from fabrication.
46 5) All longitudinal and circumferential pressure containing welds shall be 100% radiographed.
ENGG./DATE

08-Jan-15

47 6) Vacuum rings shall be utilized in the design of the deaerator. Supplier to confirm number, size & spacing.
XF.Du

48 7) Supplier shall furnish as a minimum the equipment, all components & accessories shown on the sketch (SHT 5 of 6)
49 and as specified on the data sheet.
50 8) One (1) 2" isolatable Vent connection (with manual bypass) shall be furnished by supplier for the Heater Vessel.
51 Supplier to confirm flow rates.
52 9) Dissolved oxygen in the polished condensate inlet is 1 mg/l ; the maximum concentration is 7 mg/l.
53 10) Manual overflow trap provided by Purchaser. Inlet level control valve by Purchaser.
54 11) Vendor to verify capacity based on operating condition.
55 12) Pressure loss from condensate inlet connnection to deaerator steam space shall not exceed 0.2 bar.
IS COVERED, FOR ALL APPROVAL

AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER

56
57
58
59
REVISION VALIDATION

60
61
DRAWING COMPLETION CERTIFICATE NO.

62
63
64
65
D

66

67
THIS REVISION NO.

68

DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.

DEAERATOR DAT 2
POWER GENERATION UNIT A10 D VD-068278 OF D
JAZAN SAUDI ARABIA 6
SAUDI ARABIAN OIL COMPANY
DEAERATORS A10-D-1002; A10-D-2002; A10-D-3002; A10-D-4002; A10-D-5002

UNTIL CERTIFIED AND DATED


THIS REVISION IS NOT TO BE
USED FOR CONSTRUCTION
1 ISSUED FOR: PROPOSAL PURCHASE
2 DESIGN, MANUFACTURE & TESTING SHALL CONFORM TO SPECIFICATION
3
INFORMATION TO BE COMPLETED : BY PURCHASER BY MANUFACTURER BY PURCHASER OR MANUFACTURER
REVISION DESCRIPTION 4

ISSUED FOR REVIEW


5 CONSTRUCTION FEATURES
6
DEAERATION SECTION
7
 Material :  Manways :
8
Deaerator : CS C.A. : 3.2 (mm) Support : Hinge Davit 
9
Storage: CS C.A. : 3.2 (mm) Size : (see sheet 5)
10
Heater Internal :  Storage : Support : Hinge Davit 
11
Spray Valve : 316 SS Size : (see sheet 5)
12
Tray : 316 SS Heads : Torispherical Ellipsoidal
8-Jan-15
DATE

13

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER
10-01525-0004

14
JOB ORDER/EWO NO.

ACCESSORIES CONTROLS (Note 17)


15
Relief Valve Vacuum Breaker Inlet Control Overflow Control
16
Manufacturer (Note 14) (Note 14) Supplier Supplier
REV. NO.

17
Model No. Provided by : Note 10 Note 10
18
D

Material Control Valve


19
Size Manufacturer :
20
Set Press. Model No.:
21
Vent Valve : Size :
22
BY/DATE
OTHER

Size : Material :
23
Type : Level Control
24
Material : Manufacturer :
25
Model No.:
26
Material :
27
OPERATIONS/DATE

28
INSTRUMENTS by Purchaser  by Supplier
29
Level Switches Level Gauge Pressure Gauge Thermometers
REVIEW FOR KEY DRAWINGS
REQUIRED (SAUDI ARAMCO)

30
Manufacturer
31
Model No.
32
Quantity
33
SPECIFICATIONS
CONST. AGENCY/DATE

34
 Painting :  Ladder/Platform : (Note 16)
35
 Insulation Clips : (Note 15)  Wind/Earthquake :
36
 Other : Refer to General Information on Sht 6. of 6.
37
38 Notes:
39 13) Deaerator will be located outdoors above grade.
40 14) Supplier scope of supply to include overpressure protection and vacuum breaker devices. Supplier to include
CERTIFIED/DATE

41 sizing basis in proposal.


B.Anders

8-Jan-15

42 15) Insulation to be furnished and installed by Others. Supplier to provide insulation clips.
DESIGN CERTIFICATION

43 16) Ladders and platforms scope of supply to be determined and should be in the scope of supplier.
(DESIGN AGENCY)

44 17) Supplier to furnish all instrumentation condition necessary for process control of the deaerator package.
45 18) Supplier to confirm sizes and furnish all connections necessary for proper deaerator function.
46 19) Connections shown on sketch are schematic representations only. The total number/sizes/rating/facing of nozzles and respective
47 locations are to be finalized by the Supplier.
ENGG./DATE

48 20) Supplier to confirm downcomer size and projection, include sizing basis in proposal.
8-Jan-15
XF.Du

49 21) Supplier to furnish a vortex breaker at each main outlet of the Storage Vessel.
50 22) Supplier shall confirm process data and to provide the calculation sheet for Deaeration section drum, Deaerator storage drum.
51 23) Deaerator shall still be designed for 100% cold demineralized water (34 C) makeup at the worst case scenario.
IS COVERED, FOR ALL APPROVAL

AND CERTIFICATION REQUIREMENTS, PER SAEP-334, UNDER


REVISION VALIDATION

DRAWING COMPLETION CERTIFICATE NO.


D
THIS REVISION NO.

DATA SHEET DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO REV.NO.

DEAERATOR DAT 3
POWER GENERATION UNIT A10 D VD-068278 OF D
JAZAN SAUDI ARABIA 6
NOZZLE & MANWAY SCHEDULE
SIZE TYPE/
MARK QTY. (IN) SERVICE FACING RATING SCH. REMARK
VESSEL OUTLINE DRAWING PER. NEXT PAGE B1 1 24 Outlet #1 WN/RF 300#
B2 1 24 Outlet #2 WN/RF 300#
NOTES: B3 1 16 Overflow WN/RF 300# vendor to confirm
1. Design Code: ASME Sec. , Div. 1 ED. 2013, and latest Add; U Stamp needed. A1 1 8 Pump Recirc WN/RF 300#

2. Vessel to be manufactured in accordance with 32-SAMSS-004 and applicable addendum. A2 1 10 Aux Steam WN/RF 150#
A3 1 16 Condensate Inlet WN/RF 150#
3. Vendor shall be responsible for detail design and confirm compliance with vessel codes, standard and specification , including the detail strength V 1 2 Vent WN/RF 150# see remark 5,7
calculations, local stress calculations, and if FEA needed. R1/2/3 3 Hold Relief Valve WN/RF 150# see remark 6
by supplier, see
I1 / I2 Hold Hold Downcomer WN/RF 300#
remark 8
4. Weight listed on drawing is only for reference, to be checked and confirmed by the supplier. P1 1 2 Pressure Indicator WN/RF 300#
T 1 2 Temperature Indicator WN/RF 300#
5. Some proposed material are listed, bult these will not relieve Supplier's responsibility to provide the most appropriate material. A4 1 Hold Vacuum Breaker WN/RF 300# by supplier
L1A/B 2 2 Level Transmitter WN/RF 300#
6. External attachments welded directly onto the vessel must be of the same material as the vessel itself. L2A/B 2 2 Level Transmitter WN/RF 300#
L3A/B 2 2 Level Gauge WN/RF 300#
7. Wind per ASCE 7-05 L4A/B 2 2 Level Transmitter WN/RF 300#
Base plate elevation above grade = HOLD P2 1 2 Pressure Transmitter WN/RF 300#
Wind speed = 165km/hr. M1/2 2 24 Manway WN/RF 300# see remark 3
Exposure Category =C DR 1 4 Drain WN/RF 300# see remark 7
Importance Factor=1.15
Occupancy category=IV

8. Seismic factor ASCE 7-05 REMARKS:

Ss = 43.5%g 1. ASME B16.5 FOR FLANGES NPS24 AND SMALLER.


S1 = 12.4%g 2. NOZZLE SCH. BY SUPPLIER.
PGA / Av = 10%g 3. WITH DAVIT, BLIND FLANGE, BOLTS/NUTS/GASKETS.

Site Class = D 4. THE MINIMUN PROJECTIONS FOR NOZZLES AND MANWAY NECKS IN ACCORDANCE

Importance factor =1.5 WITH 32-SAMSS-004, PARA. 8.1.2.


Seismic category = C 5. VENDOR TO PROVIDE THE RESTRICTION ORIFICE ATTACHED ON THE VENT NOZZLE.

9. Gaskets for standard flanges: Spiral-wounded gasket, SS316L windings filled with flexible graphite, 316SS outer & inner ring. 6. THE QUANTITY OF THE SAFETY VALVE SHALL BE CONFIRMED BY THE SUPPLIER.

7. THE NOZZLES FOR VENT AND DRAIN SHALL BE WITH BLIND FLANGE, BOLTS/NUTS/GASKETS.
8. THE QUANTITY AND SIZE OF THE NOZZLE SHALL BE DETERMINED BY SUPPLIER.

OPERATING CONDITIONS MATERIALS OF CONSTRUCTION INSULATION FIREPROOFING & PAINTING REQUISITION NO:
INTERNAL PRESSURE: NORMAL: 4 bar (g) COMPONENT ASME NO: INSULATION THICKNESS: 110mm VENDOR:
MAXIMUM: 5.1 bar (g) SHELL: FIREPROOFING THICKNESS: N/A
EXTERNAL PRESSURE: NORMAL: FV bar - BASE MATERIAL SA 516 Gr. 70N SHOP PRIME & PAINT YES(See Note 32) REVISION VALIDATION
MAXIMUM: FV bar - CLADDING OR OVERLAY N/A (SAPCS NO): A10-A-DOC-VE-046373 THIS REVISION NO D IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
SERVICE OTHER BOOT: FIELD PRIME & PAINT N/A REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATION NO:
If other (Specify) - BASE MATERIAL N/A (SAPCS NO): N/A
Demineralized water and condensate D
- CLADDING OR OVERLAY N/A ESTIMATED VESSEL WEIGHTS: DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
NORMAL: 143.9 Deg. C HEADS: SHIPPING: 50000 Kg (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
TEMPERATURE: MAXIMUM 306.2 Deg. C - TYPE 2:1 ELLIPSOIDAL EMPTY: 40900 Kg ENGG./DATE CERTIFIED BY/DATE CONST.AGENCY/DATE OPERATION/DATE BY/DATE
SPECIFIC GRAVITY OF LIQUID: 0.99 - BASE MATERIAL SA 516 Gr. 70N OPERATING: 152200 Kg
- CLADDING OR OVERLAY N/A TEST: 179000 Kg REV.NO. DATE ORIGINATOR REVISION DESCRIPTION
VESSEL TO BE MANUFACTURED IN ACCORDANCE WITH 32-SAMSS-004 AND APPLICABLE ADDENDUM. FLANGES: SA 105 N D 8-Jan-15 XF.Du ISSUED FOR REVIEW
PIPE: SA 106 Gr.B INSULATION SUPPORT: YES
DESIGN CONDITIONS INTERNAL ATTACHMENT CLIPS: SA 516 Gr. 70N FIREFROOFING CLIPS: N/A JOB ORDER/EWO NO. THIS DRAWING IS NOT TO BE USED FOR
ASME DESIGN CODE & EDITION: ASME VIII, Div.1 ED.2013 & latest add; U-Stamp EXTERNAL ATTACHMENT CLIPS: SA 516 Gr. 70N LIFTING LUGS: YES 10-01525-0004 CONSTRUCTION UNTIL CERTIFIED AND DATED
INTERNAL PRESSURE: 12 bar (g) EXTERNAL BOLTING/NUTS: SA193 B7/SA194 2H TAILING LUGS: N/A SAUDI ARABIAN OIL COMPANY
EXTERNAL PRESSURE: FV bar INTERNAL BOLTING/NUTS: N/A TOP DAVIT: N/A PRESSURE VESSEL DATA SHEET DRAWING TYPE DAT
TEMPERATURE: 380 Deg. C FITTING: SA 234-WPB LADDERS & PLATFORMS: YES DEAERATOR

M.D.M.T 10 Deg. C FORGING: SA-266 Gr. 2 LADDERS & PLATFORMS CLIPS: YES JAZAN IGCC POWER BLOCK PROJECT

REINFORCEMENT per code SUPPORTS: GROUNDING LUGS: YES JAZAN SAUDI ARABIA
WIND SPEED 165 km/hr - SKIRT: N/A VACUUM RINGS: YES PLANT NO INDEX DRAWING NUMBER SHT. NO. REV. NO.
ZONE: Ss = 43.5%g, S1 = 12.4%g - SADDLES: SA-283Gr. C HOT BOX: N/A
A10 D VD-068278 4 OF 6 D
EARTHQUAKE: SOIL COEFF: D - LUGS: N/A ANCHOR BOLTS TEMPLATE: N/A
Av: 10%g OTHER (SPECIFY): PIPE SUPPORTS: HOLD
EARTHQUAKE: ACCORD WITH SAES-A-112 NAMEPLATE SUPPORT: YES
GASKETS: PER NOTE 9
CORROSION ALLOWANCE: 3.2 mm NAMEPLATE: YES
RADIOGRAPHY SHELL: FULL HEADS: FULL NOZZLE PROJECTS: 32-SAMSS-004
DEAERATOR
IMPACT TESTING (IT): AS PER CODE INTERNALS
PWHT: YES (IN ACCORDANCE WITH 32-SAMSS-004) Downcomer N/A
( A10-D-1002; A10-D-2002; A10-D-3002;
I. T. TEMPERATURE By Supplier per Code Baffels N/A
A10-D-4002; A10-D-5002)
I. T. ENERGY AVE./MIN: By Supplier per Code Tray 316SS
LOCAL STRESS ANALYSIS IN ACCORDANCE WITH WRC107, WRC297 OR FEA Spray Valve 316SS
3
NOMINAL VOLUME: 130 m
Notes:
1. Reference standard drawing
Top Davit: VEFV1119M
Lifting Lug: By Supplier
Anchor Bolt: AA-036322-001
Vortex Breaker: DD-950005-001-00
Grounding Lug: VEFV1103M
Others: VEFV1100M

2. Weigh List (only for reference)


Fabrication: 40900 kg
Operation (without internals): 152200 kg
Shipping: 50000 kg
Test: 179000 kg

3. Nozzle Orientation (Hold).

4. Detail design should be performed by Supplier, and the thickness


on datasheet is only for reference, Supplier can adjust it in accordance
with detail design result.

5. The top vessel support design : By Supplier.

REQUISTION NO:
VENDOR:

REVISION VALIDATION
THIS REVISION NO D IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATION NO:

DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER


(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
ENGG./DATE CERTIFIED BY/DATE CONST.AGENCY/DATE OPERATION/DATE BY/DATE

REV.NO. DATE ORIGINATOR REVISION DESCRIPTION


D 8-Jan-15 XF.Du ISSUED FOR REVIEW

JOB ORDER/EWO NO. THIS DRAWING IS NOT TO BE USED FOR


10-01525-0004 CONSTRUCTION UNTIL CERTIFIED AND DATED
SAUDI ARABIAN OIL COMPANY
PRESSURE VESSEL DATA SHEET DRAWING TYPE DAT
DEAERATOR
JAZAN IGCC POWER BLOCK PROJECT
JAZAN SAUDI ARABIA
PLANT NO INDEX DRAWING NUMBER SHT. NO. REV. NO.

A10 D VD-068278 5 OF 6 D

DEAERATOR

( A10-D-1002; A10-D-2002; A10-D-3002;


A10-D-4002; A10-D-5002)
GENERAL NOTES:

1. SUPPLIER SCOPE IS FIVE (5) COMPLETE DEAERATOR PACKAGES FURNISHED COMPLETE 16. ALL WELDING SHALL BE PERFORMED IN ACCORDANCE WITH CODE REQUIREMENTS
WITH HEATER AND STORAGE VESSELS INCLUDING ALL INTERNALS,INTERNAL AND SAES-W-010 WELDING REQUIREMENTS FOR PRESSURE VESSELS,
ATTACHMENTS, EXTERNAL ATTACHMENTS AND SUPPORTS, MECHANICAL DEVICES, WELDING PROCEDURES INCLUDING PQR's AND WELD MAP SHALL BE SUBMITED
INSTRUMENTATION NOZZLE AND ALL NECESSORY COMPONENTS DESCRIBED HEREIN. FOR ENGINEERING REVIEW, WHICH SHALL BE COMPLETED PRIOR TO
EACH DEAERATOR SHALL BE DESIGNED AND BUILT FOR A MINIMUM SERVICE COMMENCEMENT OF FABRICATION.
LIFE OF 25 YEARS.
17. FABRICATION TOLERANCE IN ACCORDANCE WITH 32-SAMSS-004 PARA. 13.1.
2. ALL DIMENSIONS ARE IN mm FROM REFERENCE TANGENT LINE, UNLESS
OTHERWISE INDICATED. 18. NDE REQUIREMENTS IN ACCORDANCE WITH 32-SAMSS-004 PARA. 14.

3. INSULATION SPECIFICATION REQUIREMENT : IN ACCORDANCE WITH 19. PWHT SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF
A10-A-DOC-VE-046372. SAES-W-010, AND 32-SAMSS-004 PARA.15.

4. VESSEL SHALL BE PROVIDED WITH A MINIMUM OF TWO (2) LIFTING LUGS. 20. PRESSURE VESSELS MANUFACTURED IN ACCORDANCE WITH
32-SAMSS-004 ARE SUBJECT TO VERIFICATION BY THE SAUDI ARAMCO
5. LIFTING LUGS ARE TO BE DESIGNED AND FURNISHED BY VESSEL SUPPLIER. INSPECTOR IN ACCORDANCE WITH SAUDI ARAMCO INSPECTIN FORM 175.
LIFTING ATTACHMENT SHALL BE DESIGNED FOR THE ERECTION WEIGHT OF THE
VESSEL TIMES AN IMPACT FACTOR OF 2.0. 21. HYDRO. TEST SHALL BE CARRIED OUT IN ACCORDANCE WITH
a) PARENT PLATE UNDER LIFTING LUGS SHALL BE 100% ULTRASONICALLY EXAMINED SAES-A-007 AND 32-SAMSS-004, PARA. 16.3.
OVER AREA UNDER LIFTING LUGS PLUS 150mm TO ENSURE PLATE IS FREE FROM DEFECTS.
b) ALL WELDING SHALL BE 100% MT/PT EXAMINED. 22. MANUFACTURING REPAIRS SHALL BE STRICTLY CARRIED OUT
IN ACCORDANCE WITH 32-SAMSS-004, PARA.16.4.
6. FLANGE CONNECTIONS SHALL TERMINATE IN A TRUE HORIZONTAL OR VERTICAL PLANE.
BOLT HOLES SHALL STRADDLE FLANGE CENTERLINE. 23. NAMEPLATE AND STAMPING SHALL BE IN ACCORDANCE WITH THE
APPLICABLE CODE AND REQUIREMENTS OF 32-SAMSS-004,
7. ALL PRESSURE VESSELS SHALL BE DESIGNED AND FABRICATED IN ACCORDANCE WITH NAMEPLATE SHALL BE 3mm MIN. THICKNESS, 304 SS, AND
ASME BOILER AND PRESSURE VESSEL CODE SECTION VIII Div 1, LATEST ADDENDA OR CONTINUOUSLY WELDED TO THE MOUNTING BRACKET ACCORDING
SAUDI ARAMCO APPROVED EQUIVALENT INTERNATIONAL STANDARD. TO PIP VEFV1100. THE MOUNTING BRACKET SHALL BE
SUPPLIER IS RESPONSIBLE FOR DETAILED MECHANICAL DESIGN, AND SHALL CONFIRM CONTINUOUSLY SEAL-WELDED AND POSITIONED SUCH AS NOT TO
COMPLIANCE WITH VESSEL CODES AND PROJECT STANDARDS/SPECIFICATIONS. ALLOW FOR COLLECTION OF MOISTURE OR RAIN.

8. ALL REMOVABLE INTERNALS SHALL BE DESIGNED TO PASS THROUGH THE APPLICABLE 24. PAINTING SHALL BE IN ACCORDANCE WITH SAUDI ARAMCO SPECIFICATION
VESSEL MANWAY. 01-SAMSS-017 AND SAES-H-001.

9. VESSEL MANWAY SHALL BE FURNISHED COMPLETE WITH BLIND, DAVIT/HINGE, GASKETS 25. SHIPPING REQUIREMENTS IN ACCORDANCE WITH 32-SAMSS-004
AND FASTENERS. GASKET TYPE SHALL BE SPIRAL WOUND FLEXIBLE GRAPHITE FILLED PARA. 19. AND PREPARATION FOR SHIPPING, LOADING WITH SUITABLE
WITH 316SS WINDING AND CARBON STEEL OUTER RING & 316SS INNER RING. SUPPORTS FOR TRANSPORTATION TO SITE SHALL BE PROVIDED BY
SUPPLIER. REQUISTION NO:
10. FORMED COMPONENTS INCLUDING HEADS SHALL BE CHECKED VENDOR:
WHETHER HEAT TREATED IS NEEDED OR NOT IN ACCORDANCE 26. VESSEL SHALL BE THROUGHLY CLEANED INSIDE AND OUTSIDE AND SHALL BE
WITH 32-SAMSS-004, PARA13.2.12. FREE OF RUST, SCALE, SLAG, WELD SPATTER AND FOREIGN MATERIAL. REVISION VALIDATION
THIS REVISION NO D IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
11. ALL MATERIALS SHALL CONFIRM TO ASME STANDARDS FOR PRESSURE RETAINING 27. NOZZLE LOADS TO BE DESIGNED PER J95-L-DAT-VE-525361; DESIGN REQUREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATION NO:
PARTS AND ASTM FOR OTHER METALLIC PARTS. BASIS NOZZLE LOADS FOR PRESSURE VESSELS, COLUMNS, AND
SHELL/TUBE TYPE EXCHANGERS. TABLE WITH MAX. ALLOWABLE NOZZLE LOADS DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
12. ALL MATERIALS SHOWN ON THIS DATASHEET SHALL BE FURNISHED AND SHALL BE SHOWN ON THE GENERAL ARRANGEMENT DRAWING. (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
INSTALLED BY VESSEL SUPPLIER UNLESS OTHERWISE NOTED. ENGG./DATE CERTIFIED BY/DATE CONST.AGENCY/DATE OPERATION/DATE BY/DATE
28. SUPPLIER'S SCOPE SHALL BE IN ACCORDANCE WITH THE DOC. NO.
13. MATERIALS FOR PIPING WELD FITTINGS SHALL MEET THE SAME CODE SEP-PGB-ME-SOW-0015. REV.NO. DATE ORIGINATOR REVISION DESCRIPTION
REQUIREMENTS FOR THE PRESSURE COMPONENT MATERIAL D 08-Jan-15 XF.Du ISSUED FOR REVIEW
SPECIFICATION USED FOR PLATE, PIPE OR FORGINGS. 29. EXTERNAL ATTACHMENTS DIRECTLY WELDED ON TO THE VESSEL
MUST CHOOSE THE SAME MATERIAL AS THE VESSEL SHELL. JOB ORDER/EWO NO. THIS DRAWING IS NOT TO BE USED FOR
14. M.A.W.P. SHOWN ON THE NAMEPLATE IS BASED ON THE NOMINAL 10-01525-0004 CONSTRUCTION UNTIL CERTIFIED AND DATED
THICKNESS, EXCLUSIVE OF CORROSION ALLOWANCE ON DESIGN 30. ALL EQUIPMENT BOLT/ NUT TO BE COATED AS PER SAES-H-001 "G" SAUDI ARABIAN OIL COMPANY
TEMPERATURE, AND SHALL NOT BE LIMITED BY FLANGE RATINGS. FASTENERS. FLUOROPOLYMER COATING TO BE APPLIED WITH PRESSURE VESSEL DATA SHEET DRAWING TYPE DAT
09-SAMSS-107. DEAERATOR

15. ALL BODY/SADDLE MATERIAL,FLANGES, FORGINGS, FITTINGS AND PIPING JAZAN IGCC POWER BLOCK PROJECT

FOR USE OF INTERNALS SHALL BE PURCHASED FROM SAUDI ARAMCO 31. FLANGED SHALL BE RAISED FACE, AND HAVE FACING SURFACE JAZAN SAUDI ARABIA
APPROVED MANUFACTURERS. ROUGHNESS OF 125~250 AARH. PLANT NO INDEX DRAWING NUMBER SHT. NO. REV. NO.

A10 D VD-068278 6 OF 6 D
32. THE EXTERIOR SURFACE OF VESSEL SHALL BE PAINTING WITH APCS-11C
ACCORDING TO THE SPECIFICATION OF A10-A-DOC-VE-046373.

DEAERATOR

( A10-D-1002; A10-D-2002; A10-D-3002;


A10-D-4002; A10-D-5002)