NB (1) (3) (b) 26\05] 2015 B-E Sem UI Rev Civil-DDRcs QP Gode : 8131 (4 Hours) [Total Marks : 100 ‘Question No.1 is compulsory. ‘Attempt any three questions out of remaining questions. Use of IS 456 is permitted. Figure below shows a typical framing plan for a office bullding. The desi load Is 4 KN/m? and floor finish load is 1.5 KN/m?. All external beams.and beam Bm4 and Bm10 are supporting 230 mm thick brick wall. Floor to floor height is 3.2 m. Grade of concrete M 20 and steel Fe 416. All columns are 309 mm x 300 mm. in size d [-2700~;=2700-}=2700---2700— 300 Bm3 emo Saerearmonem ‘Orrser FROM FACE OF COLUMN ‘ONAL SIDES Design and drew suitable sketches showing designed reinforcement for, Slab Sb - She 15 Beam Bm7- me 25 Draw to tite scale suitable sketches showing designed reinforcement. <<>> Design by approximate method a rectangular R.C.C water tank 6.0m x4.0min 32 pln-and 3.3 m in height. Tank is resting on’firm ground. Design side walls and base slab. Grade of concrete is M 25 and steel is Fe 415. Check the design for gafe stresses. Draw plan @ 1.0 m above base showing reinforcement. Also draw necessary sections showing reinforcement detail. Explain with sketches various type of joints for water tanks. 08 [TURN OVER RJ-Con. 10536-15. (a) (b) 2 QP Code : 8131 Design a doglegged staircase for a office building as shonw in figure given in Q. No. 1, Also show arrangmant of flights giving details. Draw reinforcement details for both flights. Use M 20 grade concrete and Fe 415 steel. A reinforced concrete canilever retaining wall is supporting a backfill of hel 4.2m above ground level with, Density of soll = 16.5 kN/m®, Angle of repose = 30°, S. B. C. of soil = 195 kN/m? and coefficient of friction beiween conerete and soil = 0.45. Design stem and toe of wall and show ali stability checks. Draw reinforcement details of toe and stem showing cuttailment of enforcement. Use M 25 grade concrete and Fe 500 steel. Design a circular water tank using IS code method for the capacity of 350 m* Depth of water in tank is limited to 4.0 m including free board, The connection between wall and base slab is rigid. Use M 25 grade concrete and Fe 00 steel. 1. Explain when following types of foundation are prefeired- 1. Isolate footing 2. Combined footing 3. Raft foundation 2. Explai neat sketch difference in the behavior of cantilever and countrfort type retaining walls. Design and draw with the data given in‘. No.1 Raft foundation as shown in figure by dotted line supporting the columns with working loads as given below. Net bearing capacity = 65 kN/m? A1,A3,C1&C3 = 800kKN B1,A2,83&C2_ — =1000 KN Bz =1600 kN RJ-Con. 10536-15. [TURN OVER 20 20 15 05 20 3 Table 1 QP Code : 8131 ‘TABLE “nnefON IM CINGULAR RING WAL, FERED BABE, FREE TOP AND (Glau 3.161) Tm Coeficient x mHR bel) | Commmomers i . oe oH On 02H OSH O4H osH 06H O71 08H os oO @ ® o eo © on ® «a Se ste sam aime ek ate es i He He BR Ee ee oe ie 3H H BB Ge Be Ge He be ee pea ERE EE BH ORE BE Ge 2H iat = Soe ee Ge ie. aes eee eee ee io i" S04 Sis 40-447 ot 2 EG 22 ER EE EG ER Eee ER Ee “son eas emt HR! qe a pies yom ewe ome BHERRPWBRBE HEH 2 32 te Be BS Be Bet He BE ie tery el SI. Table 2 (eeu 2.0) TOMENTS IN GXLINDSICAL, FIXED BASE, FRE TOP AND ae SUnjecr 70 VRENCULH LOAD. Meuaincnitatnait tata | conmenr ss emt CsH O64 OSH OSH OFF 08H GOH 10H ro © © cu} @ o (10), ay 40-0021 40-0007--=0-00%2 0.0150 0.0302 —pés29 0081s —oa205 Hae: 9mm sams sta gm nome creas mou Sen iets ess ioe Hee ie eel ae HES GH eee HSE Heat coal Sees Sia +0:007 40-0071 1090 4-0-0087, 7 40-0012 —9-0119 —0-0333 40-0028 0:0047 40-0065 40-0077 40-0069 40-0023 —0-0080 —-0-0268 ae See Es Re ee ieee ¢ ieee Hee Hee tet es at ie et BE: a HER Hel ae Sel Re 22 sae: 9m je 2009 0m yee — 13 #Egml Heam toed ieee iets seen oy tog 8 “Et Ee SER) GE RE ED HER) ERR Nove 1 —rweDemsity ofthe liquid. e ‘Nora 2—Pasllve slga indicates telon on the outside, RJ-Con. 10536-15. 4 QP Code : 8131 Table 3 TABLE .. aclEAR AT BASE OF CYLINDRICAL WALL ( Clauses 8.1,1, 3-1-2 and 3.1.3) wH* kg ( triangular o= Cocfficient x 4 pif kg { rectangular ) Ajit kg (mwoment at base ) Fu) TFutawounan RECTANGULAR © _ “TRIANGULAR OR Moment Dt Loap Pixa> Loan For Rectawouan Leas at Base ‘Bate Horan Bam Epos, Ot 0486 40-755 ORS hss 08 40-378 + $0552 HOR 175 12 +0399 +0460 #0220 200 16 +0317 +0-407 40-204 2-28 20 +0299 “40370 $0189 257 30 40-262 +0310 +0158 HB 40 40236 +027! +0137 368 50 F023 poss +Onat —#10 60 +0197 $0222 +0110 449 80 HO17E +0-198 + 10-096, 18 100 40-158 40-172 40-007 —58L 120 +0445 40-158 +0079 638 140 40-135, 0047 +0075 608 6-6 +0127 $0197 + 0-068: 736 Nota 1 — w= Demity of the liquid, Nore 2 — Positive sign indicates shear acting toward, RJ-Con. 10536-15.

Anda mungkin juga menyukai