FEATURES
In the process of gas absorption, a mixture of gases is The packed absorption column is made of clear acrylic and is
contacted with a liquid, for the purpose of dissolving one installed vertically on a mild steel floor-standing framework.
or more components of the gas and to provide a solution of The column is filled with 10mm x 10mm of glass Raschig
them into the liquid. rings, which are representative of random packing used in
gas absorption on an industrial-scale. Liquid is stored in a
In UOP7MkII, a gas phase consisting of CO and air is feed tank and a variable speed submersible pump is used to
introduced into the bottom of the packed column. pump the liquid into the column. An electronic flow meter
Adjustment of their flow ratio is obtained by manual valves. sensor is installed in the water line to provide accurate
A sample of the gas mixture is sent to a CO concentration measurement of the liquid flow entering the column.
sensor located inside the electric console, and readings of
flows and CO percentage concentration are seen on the The gas to be absorbed is carbon dioxide (CO), and
display. would be taken from a pressure cylinder (not supplied).
Gas regulator, control valve and electronic flow meter
For the liquid phase, water (or a solution of sodium are used to regulate gas flow. A centrifugal fan provides
hydroxide) is pumped to the top of the column where air flow to the column. The air line also includes a gate
it falls through the packing material. The contact of the valve for flow control and an electronic flow meter.
two phases is in counter-current operation and enhances
the mixing and diffusion of CO in the liquid phase at the Pressure tappings at the base, centre and top of the
conditions of room temperature and atmospheric pressure. column are provided to enable indication of pressure
drops in the column using electronic pressure sensors.
The outlet gas leaves the system from the top of the
column. A sample of the outlet gas mixture is also Liquid and gas temperature readings are obtained by
taken and sent to the CO sensor located inside the thermistors in the liquid tank and the inlet gas line.
console. Reading of CO concentration is shown on the
console'sdisplay.
The outlet liquid leaves the system from the bottom of the
column and returns to the water tank. Samples of the liquid
phase entering and exiting the system can easily be taken
for further analysis.
ORDERING SPECIFICATION
REQUIREMENTS
An apparatus for teaching the principles of the
Electrical supply: absorption of gas into liquid, using a packed column
UOP7-MkII-A: 220-240V/1ph/50Hz, 2A Column working length is 1.4m x 80mm diameter,
UOP7-MkII-B: 115V/1ph/60Hz, 4A split into two sections
UOP7-MkII-G: 220-240V/1ph/60Hz, 2A
Two electronic pressure sensors measure the pressure
Water supply: drop across each half of the column
5 l/min at 2 bar An electronically controlled submersible pump provides
a liquid flow of 1-10 l/min
CO supply:
60l feed tank
20 l/min at 1 bar
Water flow can be used in either recycle or one-pass
Computer: A Windows PC (not supplied) running operation
Windows 98 or later, with USB port is required Column supplied with 10mm x 10mm Raschig rings
if running the data logging software as packing material, total volume 7 litres. Other sizes
can beused
OVERALL DIMENSIONS Centrifugal fan provides air flow up to 160 l/min
Height: 2.876 m (1.781m disassembled) Two electronic temperature sensors measure the air
Width: 1.017m and liquid temperatures
Depth: 0.667m Electronic measurement of CO concentration in the air
Net weight: 100kg (dry, unpacked) streams, measurements can be taken at the column inlet
and outlet
SHIPPING SPECIFICATION
Sensor values displayed on an alpha-numeric display
Gross weight 200kg on the control console
Volume 2.2m3 Data logging as standard (requires PC, not supplied)