SIMATIC 2010_12_04_radarV0\ 03/11/2011 08:42:45 AM

SIMATIC 300 RADAR\CPU 315-2 DP\...\OB35 - <offline>

OB35 - <offline>
"CYC_INT5" Cyclic Interrupt 5
Name: Family:
Author: Version: 0.1
Block version: 2
Time stamp Code: 01/14/2011 08:18:08 AM
Interface: 02/15/1996 04:51:11 PM
Lengths (block/logic/data): 00844 00722 00026

Name Data Type Address Comment


TEMP 0.0
Bits 0-3 = 1 (Coming event), Bits 4-7 = 1
OB35_EV_CLASS Byte 0.0 (Event class 1)
OB35_STRT_INF Byte 1.0 16#36 (OB 35 has started)
OB35_PRIORITY Byte 2.0 Priority of OB Execution
OB35_OB_NUMBR Byte 3.0 35 (Organization block 35, OB35)
OB35_RESERVED_1 Byte 4.0 Reserved for system
OB35_RESERVED_2 Byte 5.0 Reserved for system
OB35_PHASE_OFFSET Word 6.0 Phase offset (msec)
OB35_RESERVED_3 Int 8.0 Reserved for system
OB35_EXC_FREQ Int 10.0 Frequency of execution (msec)
OB35_DATE_TIME Date_And_Time 12.0 Date and time OB35 started

Block: OB35 "Cyclic Interrupt"

Page 1 of 8
SIMATIC 2010_12_04_radarV0\ 03/11/2011 08:42:45 AM
SIMATIC 300 RADAR\CPU 315-2 DP\...\OB35 - <offline>

Network: 1

DB80
"5 nolu
tank"
FB41
Continuous Control
"CONT_C"
EN ENO

COM_RST LMN

DB114. LMN_PER PQW256


DBX12.0 MAN_ON
QLMN_HLM
PVPER_ON
QLMN_LLM
P_SEL
LMN_P
I_SEL
LMN_I
INT_HOLD
LMN_D
I_ITL_ON
PV
D_SEL
ER
T#100MS CYCLE

DB114.DBD4
"PID_
RANSAL_
VAN".
TANK5_
AUTO_SET SP_INT

DB110.DBD6
4
"SICAKLIK_
TANK".ETB5 PV_IN

PV_PER

DB114.DBD8
"PID_
RANSAL_
VAN".
TANK5_MAN_
SET MAN

GAIN

TI

TD

TM_LAG

DEADB_W

LMN_HLM

LMN_LLM

PV_FAC

PV_OFF

LMN_FAC

LMN_OFF

I_ITLVAL

DISV

Page 2 of 8
SIMATIC 2010_12_04_radarV0\ 03/11/2011 08:42:46 AM
SIMATIC 300 RADAR\CPU 315-2 DP\...\OB35 - <offline>

Network: 2

DB81
"8 nolu
tank"
FB41
Continuous Control
"CONT_C"
EN ENO

COM_RST LMN

DB114. LMN_PER PQW258


DBX26.0 MAN_ON
QLMN_HLM
PVPER_ON
QLMN_LLM
P_SEL
LMN_P
I_SEL
LMN_I
INT_HOLD
LMN_D
I_ITL_ON
PV
D_SEL
ER
T#100MS CYCLE

DB114.
DBD18 SP_INT

DB110.DBD7
6
"SICAKLIK_
TANK".ETB8 PV_IN

PV_PER

DB114.
DBD22 MAN

GAIN

TI

TD

TM_LAG

DEADB_W

LMN_HLM

LMN_LLM

PV_FAC

PV_OFF

LMN_FAC

LMN_OFF

I_ITLVAL

DISV

Page 3 of 8
SIMATIC 2010_12_04_radarV0\ 03/11/2011 08:42:46 AM
SIMATIC 300 RADAR\CPU 315-2 DP\...\OB35 - <offline>

Network: 3

DB82
"13 nolu
tank"
FB41
Continuous Control
"CONT_C"
EN ENO

COM_RST LMN

DB114. LMN_PER PQW260


DBX40.0 MAN_ON
QLMN_HLM
PVPER_ON
QLMN_LLM
P_SEL
LMN_P
I_SEL
LMN_I
INT_HOLD
LMN_D
I_ITL_ON
PV
D_SEL
ER
T#100MS CYCLE

DB114.DBD3
2
"PID_
RANSAL_
VAN".
TANK13_
AUTO_SET SP_INT

DB110.DBD9
6
"SICAKLIK_
TANK".
ETB13 PV_IN

PV_PER

DB114.DBD3
6
"PID_
RANSAL_
VAN".
TANK13_
MAN_SET MAN

GAIN

TI

TD

TM_LAG

DEADB_W

LMN_HLM

LMN_LLM

PV_FAC

PV_OFF

LMN_FAC

LMN_OFF

I_ITLVAL

DISV

Page 4 of 8
SIMATIC 2010_12_04_radarV0\ 03/11/2011 08:42:46 AM
SIMATIC 300 RADAR\CPU 315-2 DP\...\OB35 - <offline>

Network: 4

DB83
"15 nolu
tank"
FB41
Continuous Control
"CONT_C"
EN ENO

COM_RST LMN

DB114. LMN_PER PQW262


DBX54.0 MAN_ON
QLMN_HLM
PVPER_ON
QLMN_LLM
P_SEL
LMN_P
I_SEL
LMN_I
INT_HOLD
LMN_D
I_ITL_ON
PV
D_SEL
ER
T#100MS CYCLE

DB114.
DBD46 SP_INT

DB110.DBD1
16
"SICAKLIK_
TANK".
ETB15 PV_IN

PV_PER

DB114.
DBD50 MAN

GAIN

TI

TD

TM_LAG

DEADB_W

LMN_HLM

LMN_LLM

PV_FAC

PV_OFF

LMN_FAC

LMN_OFF

I_ITLVAL

DISV

Page 5 of 8
SIMATIC 2010_12_04_radarV0\ 03/11/2011 08:42:46 AM
SIMATIC 300 RADAR\CPU 315-2 DP\...\OB35 - <offline>

Network: 5

DB84
"20nolu
tank"
FB41
Continuous Control
"CONT_C"
EN ENO

COM_RST LMN

DB114. LMN_PER PQW264


DBX68.0 MAN_ON
QLMN_HLM
PVPER_ON
QLMN_LLM
P_SEL
LMN_P
I_SEL
LMN_I
INT_HOLD
LMN_D
I_ITL_ON
PV
D_SEL
ER
T#100MS CYCLE

DB114.DBD6
0
"PID_
RANSAL_
VAN".ETB4 SP_INT

DB110.DBD1
36
"SICAKLIK_
TANK".
ETB20 PV_IN

PV_PER

DB114.DBD6
4
"PID_
RANSAL_
VAN".ETB5 MAN

GAIN

TI

TD

TM_LAG

DEADB_W

LMN_HLM

LMN_LLM

PV_FAC

PV_OFF

LMN_FAC

LMN_OFF

I_ITLVAL

DISV

Page 6 of 8
SIMATIC 2010_12_04_radarV0\ 03/11/2011 08:42:46 AM
SIMATIC 300 RADAR\CPU 315-2 DP\...\OB35 - <offline>

Network: 6

DB85
"22 nolu
tank"
FB41
Continuous Control
"CONT_C"
EN ENO

COM_RST LMN

DB114. LMN_PER PQW266


DBX82.0 MAN_ON
QLMN_HLM
PVPER_ON
QLMN_LLM
P_SEL
LMN_P
I_SEL
LMN_I
INT_HOLD
LMN_D
I_ITL_ON
PV
D_SEL
ER
T#100MS CYCLE

DB114.
DBD74 SP_INT

DB110.DBD1
44
"SICAKLIK_
TANK".
ETB22 PV_IN

PV_PER

DB114.
DBD78 MAN

GAIN

TI

TD

TM_LAG

DEADB_W

LMN_HLM

LMN_LLM

PV_FAC

PV_OFF

LMN_FAC

LMN_OFF

I_ITLVAL

DISV

Page 7 of 8
SIMATIC 2010_12_04_radarV0\ 03/11/2011 08:42:46 AM
SIMATIC 300 RADAR\CPU 315-2 DP\...\OB35 - <offline>

Page 8 of 8