Open System Capability:

Channels: 100 channels, includes user-defined applications


Buyer 3rd Party Applications: Varies by country, can be configured on system
ISE:
ISE: Indirect simultaneous measurement of Na+, K+, Cl -
Sample Volume: 22 L for all three tests
Priming:Automatic priming cycle
Electrode Shelf Life: 30,000 samples
Throughput Rate: 600 tests/hour; 200 tubes/hour
Calibration/QC:
Calibration Interval: Up to 60 days, tracked by software
Auto-calibration/Auto-QC: User-defined time interval or with new reagent container
View Calibration/QC Data: Graphical display of calibration curves and QC; RealTime
QC
Calibration/Control Tray: 61 refrigerated positions for calibrators, controls, and diluents
Data Management:
Operating Computer: Windows XP, 1 Gb RAM, touch screen monitor 19
System Documentation: Operator manual and method sheets online
Host Interface: RS 232C bidirectional
Data Storage: 70,000 patient tests
Onboard Maintenance Logs: Schedule and monitor routine maintenance activities via
software
Host Query: ASCII; system requests work order or batch of work orders from host
General Specifications:
Power Requirements: 200/220/230/240 V +/ 10%, 20 A, 50/60 Hz, 3 KVA
Water Requirements: Deionized water from pressurized water
(10-30 psi/169-207 KPa)
Average Consumption: 30 liters per hour
Drain Requirements: Maximum of 10.6 gallons (40 liters) per hour
Dimensions:
ADVIA 1800: 44.6 (h) x 58.3 (w) x 34.5 (d) in, 113.3 (h) x 148.0 (w) x 87.6 (d) cm
Universal Rack Handler: 37 (h) x 29 (w) x 41 (d) in, 86.4 (h) x 73.7 (w) x 104.1 (d) cm
Weight:
ADVIA 1800: 1,323 lbs (600 kg)
Universal Rack Handler: 178 lbs (81 kg)
Compliance: UL, cUL, CE
Noise Specifications: Open cover less than 70 db
Average Heat Output: 4,299 BTU/hour @ 50 Hz, 3,023 BTU/hour @ 60 Hz
Operating Temperature Range: 18-30C/64-86F
Ambient Humidity: 40%-70%

Overview
Type of systems Random continuous access, batch, discrete processing
Throughput Rate 800 tests/hour colorimetric, 600 tests/hour ISE, 1200/hour combined
Methods on-board 44 including 3 ISE
Sample handling
Sample Tubes 2 mL, 5 mL, 7 mL, 10 mL, sample tubes/cups, microcontainer tubes
Sample Tray 84 samples, continuous loading, positive sample identification
STAT Positions User-defined option for up to 84 dedicated positions
Bar Codes Interleaved 2 of 5, code 39, code 128, Codabar (NW7)
Auto-repeat Automatic repeat testing from the original sample
Auto-dilution Automatic dilution from the original sample
Reflex Testing Ability to perform 3 additional tests based on results of first test
Liquid Level Sensing Capacitance technology
Crash Prevention Spring loaded sensor prevents sample probe crashes
Clot detection Automatic alert when clot or clog detected
Original Sample Volume 1 to 25
Reaction area
Reaction Tray 231 reusable plastic cuvettes
Cuvette Optical Path 10 mm
Length
Reaction Bath Inert fluorocarbon oil circulation system, 37C
Photometer 14 fixed wavelengths
LIGHT SOURCE 12V, 50W halogen lamp, cooled by forced water circulation
Assay Methods Endpoint, rate reaction, 2-point rate, multi-point homogeneous immunoassay
Reaction Times 3, 4, 5, and 10 minutes
Automatic Correction Serum blank, cell blank, measurement point change, sample volume change in
reassay
Point Forwarding Automatically extends linearity for over assay range samples
Reactant Volume 80-430
Reagent Handling
Reagent Capacity 41 colorimetric methods
Reagent Tray 2 trays, 45 position each, refrigerated
Dispensing System 2 probes with liquid level sensing
Reagent Wedges 20, 40, 70 mL bar-code labeled wedges
Reagent Inventory Tracks tests remaining, lot number, on-board stability and expiration date
MANAGEMENT
Reagent Dilutions Capability to dilute concentrated reagents on-board
Open system capability
Channels 100 channels, includes user-defined applictions
Bayer 3rd party Varies by country; can be configured on system
applications
ISE
ISE Indirect simultaneous measurement of Na+, K+, Cl-
SAMPLE VOLUME 22
Priming Automatic priming cycle
Electrode shelf life 30,000 tests per electrode
Throughput Rate 600 tests per hour
CALIBRATION
CALIBRATION STABILITY Average 14 days
Auto-Calibration User-defined time interval or with new reagent container
View Calibration Curve Graphical display of calibration curve via software
Calibration/Control tray 61 refrigerated positions for calibrators, controls and diluents
DATA MANAGEMENT
Operating system Microsoft Windows XP Professional
System Operator manual and instructions for use on-line and on CD
DOCUMENTATION
Host Interface RS232c bidirectional
DATA STORAGE 70,000 patient samples
On-board Schedule and monitor routine maintenance activities via software
maintenance logs
General specifications
POWER CONSUMPTION 200/220/230 V+/- 10%, 15 A, 50/60 Hz, 3 KVA
Water requirements Deionized water from a 1-10 meter pressure reservoir; capable to deliver 20
liters per hour
Drain requirements Floor drain to handle minimum of 6.8 gallons (25 liters) per hour
DIMENSIONS 110.8 (H) x 122 (W) x 85 (D) cm; 44 (H) x 48 (W) x 33.5(D) in
Footprint 1.04 square meters
WEIGHT 450 kg/1,000 lbs
Compliance UL, cUL, CE
Noise specifications Open cover less than 60 db, closed cover less than 45 db