Anda di halaman 1dari 4

SWAL

Asia Limited

Building and Structural

(Alterations & Additions

Signboard Supporting Frame)

Works

At

Circle Plaza,

No.447-449, Hennessey Road,

Causeway Bay,

Hong Kong

Structural Appraisal Report

Ir Law Yue Kei Ricky


Registered Structural Engineer (RSE 22/00)

BD Ref. : BD 2-3/3133/76/ (SB)

Project No. : 90309/12

Structural Engineer : SWAL Asia Ltd.

Date : 19th March 2012

SWAL
No Part of this document may be reproduced or transmitted, in any form or by any means electronic, mechanical, photographic, recording or
otherwise, or stored in a retrieval system of any nature without the written permission of SWAL Asia Ltd. Application for which shall be
made to SWAL Asia Ltd., Unit 2501, 25/F, 113 Argyle Street, Kowloon., Hong Kong.
Proposed Signboard at No.447-449, Hennessy Road, Causeway Bay, Hong Kong

TABLE OF CONTENT

Content Page
1. Introduction 1-1

2. Proposed Work 1-1

3. Site Inspection 1-1

4. Conclusion 1-1

Appendix A Photo Record for Existing Building

Structural Calculation
Contract Job No.
Proposed Signboard at No.447-449, Hennessy Road, Causeway Bay, Hong Kong 90309/12

SWAL Asia Limited Drg. Ref. Calcs by Checked by Calc. Sht. No.
ENGINEERING CONSULTANT D.T. 1
Part of Structure Date
Appraisal Report 19-Mar
Ref. Calculations

1.0 Introduction

A signage supporting frame from level +9.806 to level +16.848 is proposed to erect at Circle Plaza,
No.447-149, Hennessey Road, Causeway Bay, Hong Kong

SWAL Asia Ltd is duly appointed as Registered Structural Engineer to prepare the structural
submission to Buildings Department for approval.

2.0 Proposed Works

There signage supporting frame approximately 6.97m (H) x 4.1m(L) x 0.25m(W) facing Hennessey Road.
The proposed sign board will be project about 4.1m from the building boundary line.

The proposed signage would be mounted to existing structural elements, via the 'HILTI' anchor and
through bolt system transfer loading directly to column.

All the supporting structures are constructed in form of structural steels which would be fastened
to existing structural elements by anchor and through bolt.

3.0 Site Inspection

Visual inspection was carried out regarding the condition on overall building structure element and
it surrounding area.

The existing commercial building built in 1977 and the building covered area approximate
to be 19m(L) x 10m(W) with 22 storey.

The existing building is a 22 storey R.C. beam & column moment frame structure and
4/F is the podium and without transfer structure.

The existing super-structure is founded on pile foundation and with a pile cap

During the inspection, no undue structural cracks and/or spalling were noted. The existing structure
is considered to be in good condition.

4.0 Conclusion

It can be concluded that the eraction of signboard steel from will not affect to existing building.
Appendix A

Photo Record for


Existing Building