AUTO START AND AUTO MAINS FAILURE ENVIRONMENTAL TESTING STANDARDS

CONTROL MODULES ELECTRO-MAGNETIC COMPATIBILITY


(ALTERNATOR FREQUENCY & CAN SPEED SENSING) BS EN 61000-6-2
EMC Generic Immunity Standard for
the Industrial Environment
BS EN 61000-6-4
FEATURES EMC Generic Emission Standard for
the Industrial Environment

ELECTRICAL SAFETY
The DSE4510 Auto Start Control Electronic J1939 (CAN) and non- BS EN 60950

Module and the DSE4520 Auto electronic (alternator frequency * AVAILABLE VARIANTS Safety of Information Technology Equipment,
including Electrical Business Equipment
Mains (Utility) Failure Control sensing) engine support for diesel, 4510-03 Auto start with real time clock
TEMPERATURE
Module are suitable for a wide gas and petrol engines all in one BS EN 60068-2-1
4510-04 Auto start with real time clock &
variety of single gen-set variant. With a number of flexible heated display Ab/Ae Cold Test -30 oC
applications. inputs, outputs and protections, the BS EN 60068-2-2
4520-03 Auto Mains Failure with real time Bb/Be Dry Heat +70 oC
module can be easily adapted to
clock
Whilst maintaining functions suit a wide range of applications. VIBRATION
BS EN 60068-2-6
included within higher end 4520-04 Auto Mains Failure with real time
Ten sweeps in each of three
controllers, such as generator or Through USB Communication both clock & heated display major axes
load power monitoring, the modules can be easily configured 5 Hz to 8 Hz at +/-7.5 mm,
8 Hz to 500 Hz at 2 gn
DSE45xx range of especially using the DSE Configuration Suite
compact controllers provide the PC Software or can be fully HUMIDITY
BS EN 60068-2-30
user with the ultimate size to configured through the module's Db Damp Heat Cyclic 20/55 oC
feature ratio. front panel editor. at 95% RH 48 Hours
BS EN 60068-2-78
Cab Damp Heat Static 40 oC
Monitoring engine speed, oil All DSE products are supported by at 93% RH 48 Hours
pressure, coolant temperature, the DSE global technical support
SHOCK
frequency, voltage, current, power team which gives our customers BS EN 60068-2-27
and fuel level, the modules will give and end users access to 24 hour Three shocks in each of three major axes
comprehensive engine and system help and advice. 15 gn in 11 mS

alternator protection. This will be DEGREES OF PROTECTION


indicated on the largest back-lit PROVIDED BY ENCLOSURES
BS EN 60529
LCD icon display in its class via an IP65 - Front of module when installed into the
array of warning, electrical trip and control panel with the optional sealing gasket.
shutdown alarms.

COMPREHENSIVE FEATURE LIST TO SUIT A


WIDE VARIETY OF GEN-SET APPLICATIONS
PC

4 4 3

USB CONFIGURABLE DC OUTPUT ANALOGUE SENDERS DC POWER


PORT INPUTS (2 for DSE4510) SUPPLY

DEUTZ
DSE4510/20 ISUZU
PERKINS
CATERPILLAR
MTU
7 VOLVO
CUMMINS
OTHER SCANIA

MAINS (UTILITY) DC OUTPUT GENERATOR / DC OUTPUT GENERATOR CHARGE FUEL AND START ELECTRONIC
SENSING 4520 1 OF 4 LOAD CURRENT 4510 1 OF 2 SENSING ALTERNATOR OUTPUTS ENGINE CAN
(DSE4520) 4520 1 OF 4 (Flexible with CAN)

VOLTS VOLTS
D+ +
+ + W/L

1ph 1 1ph 1 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N N

ISSUE 1

DSEGenset

DSE4510/20 SPECIFICATION
AUTO START AND AUTO MAINS FAILURE
CONTROL MODULES DC SUPPLY
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
(ALTERNATOR FREQUENCY & CAN SPEED SENSING)
CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
FEATURES supply recovers to 5 V. This is achieved
without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.

DSE4520 MAXIMUM OPERATING CURRENT


85 mA at 12 V, 96 mA at 24 V

MAXIMUM STANDBY CURRENT


51 mA at 12 V, 47 mA at 24 V

MAXIMUM SLEEP CURRENT


DSE4510 35 mA at 12 V, 32 mA at 24 V

MAXIMUM DEEP SLEEP CURRENT


<10 uA at 12 V, <10 uA at 24 V

MAINS (UTILITY) DSE4520 ONLY


VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE
3.5 Hz to 75 Hz

OUTPUTS
OUTPUT A (FUEL)
10 A short term, 5 A continuous,
at supply voltage

OUTPUT B (START)
10 A short term, 5 A continuous,
at supply voltage
KEY BENEFITS KEY FEATURES Fuel and start outputs
Ultimate size to feature ratio Alternator frequency & CAN (configurable when using CAN) AUXILIARY OUTPUTS C & D
2 A DC at supply voltage
Automatically transfers between speed sensing in one variant 4 configurable DC outputs (2 for
mains (utility) and generator Largest back-lit icon display in DSE4510) AUXILIARY OUTPUTS E & F DSE4520
(DSE4520 only) its class 3 configurable analogue/digital 2 A DC at supply voltage
Hours counter provides accurate Heated display option inputs GENERATOR
information for monitoring and Real time clock provides 4 configurable digital inputs VOLTAGE RANGE
maintenance periods accurate event logging Configurable staged loading 15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)
User-friendly set-up and button Fully configurable via the fascia outputs
layout for ease of use or PC using USB 3 engine maintainance alarms FREQUENCY RANGE
Multiple parameters are communication Engine speed protection 3.5 Hz to 75 Hz
monitored simultaneously which Extremely efficient power save Engine hours counter DIMENSIONS
are clearly displayed on the mode Engine pre-heat OVERALL
largest back-lit icon display in 3 phase generator sensing Engine run-time scheduler 140 mm x 113 mm x 43 mm
5.5 x 4.4 x 1.7
its class 3 phase mains (utility) sensing Engine idle control for starting &
The module can be configured (DSE4520 only) stopping PANEL CUT-OUT
to suit a wide range of Compatible with 600 V ph to ph Battery voltage monitoring 118 mm x 92 mm
4.6 x 3.6
applications nominal systems Start on low battery voltage
Uses DSE Configuration Suite Generator/load power Configurable remote start input MAXIMUM PANEL THICKNESS
PC Software for simplified monitoring (kW, kV A, kV Ar, pf) 1 alternative configuration 8 mm
0.3
configuration Accumulated power monitoring Comprehensive warning,
Compatible with a wide range (kW h, kVA h, kVAr h) electrical trip or shutdown
-40 C to +85 C
STORAGE TEMPERATURE RANGE

-40 F to +185 F
of CAN engines Generator overload protection protection upon fault condition
Licence-free PC software (kW) LCD alarm indication
IP65 rating (with optional Generator/load current Event log (50)
-30 C to +70 C
OPERATING TEMPERATURE RANGE

-22 F to +158 F
gasket) offers increased monitoring and protection
resistance to water ingress
-40 C to +70 C (for heated display variant)
-40 F to +158 F (for heated display variant)
RELATED MATERIALS
TITLE PART NOS
DSE4510/20 Installation Instructions 053-157 OPTIONAL PARTS
DSE4510/20 Operator Manual 057-171
DSE4510/20 Configuration Suite PC Manual 057-172 PART PART NUMBER
IP65 Gasket 020-282

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-132/09/12 (7)
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457