Purchase Order No: 3568 002 8PM 25th,August-8AM Date of Visit: 26th,August,2016 MATERIAL INSPECTED THIS VISIT Item No. Quantity Description Tag No., Batch No., Serial No., Cast, Heat No. 1 1 Raw coil material inspection Detail as following table
SUMMARY / AREAS OF CONCERN
GUI-036-00 (Revision 0) Flash Report Dated: 22nd March 2016
www.GQIS.com Inspection Report
Customer: EM Purchase Order 3568
No.:
1. SMMARY / AREAS OF CONCERN:
1.1 Raw coil material inspection.
GQIS inspector performed inspection for coil material according to ITP and drawing, the detail inspection content as following table, all the data in line with ITP & drawing & specification, the result satisfactory. Coil No. Material Grade Size Heat No. Delivering Specification Condition 167111902 S420M 1501X24.67 16303198 Hot Rolled EN 10025-4 2004:S420M
1.2 Review all instruments and measurement tools calibration certificates.
GQIS inspector review all instruments and measurement tools calibration certificates, confirm the calibration process and result satisfactory the standard and code, all certificates are valuable and not found any instrument or tool expire of valuable time.
1.3 Visual and dimension inspection
GQIS inspector performed visual and dimension inspection for pile No. 3568-C04-065 according to ITP(No.14) and drawing, the inspection result as: outside diameter: 913mm~914mm, roundness:1mm, welding reinforce: 2mm, straightness:29mm(the drawing require straightness less than 40mm, the factory initiative rectified by fire), after rectified checked the straightness about 6mm, at the same time asked the factory examination the baked area by MT and not found any indication. Confirmed all data satisfactory applicable document 3568-MPS-01 CK/QP5.7.4 and drawing, the result acceptable.
Picture
Inspection raw coil material.
Inspection raw coil material.
Review all instruments and
measurement tools calibration certificates.
Visual inspection
Visual and dimension
inspection for pile of 3568- C04-065, and performed MT after rectified straightness by fire.
GUI-035-00 (Revision 0) Inspection Report Dated: 22nd March 2016
www.GQIS.com Inspection Report
Customer: EM Purchase Order 3568
No.:
Accepted Yes Non-Compliant Yes / No
Technical Specialist: Su Jinlong Operations Coordinator:
Date: Date: 8PM 25th,August-8AM 26th,August,2016
GUI-035-00 (Revision 0) Inspection Report Dated: 22nd March 2016