INSTRUCTION MANUAL
Thankyouforpurchasing850SMDReworkStation.
Pleasereadthemanualbeforeusingtheunit.
Keepmanualinaccessibleplaceforfuturereference.
WARNING: When turned ON, temperature of the hot air gun ranges
from 100C 500C. Injury might occur if not handled properly.
**ThisproductisESDprotected.
**Specificationsanddesignaresubjecttochangewithoutpriornotice.
ManufacturedBy:
AOYUETONGYIELECTRONICEQUIPMENTFACTORY
JishuiIndustrialZone,Nantou,ZhongshanCity,
GuangdongProvince,P.R.China
http://www.aoyue.com 8
REPLACINGTHEHEATINGELEMENT
1. Removethescrews(seefig.4)thenslideoffthetube.
2. Disconnect the ground wire sleeve (see fig. 51) and remove
thepipe.Insidethepipe,theQuartzglassandheatinsulationis
installed.
TABLEOFCONTENTS 3. Disconnect the terminal (see fig. 52) and remove heating
element.
4. Carefully insert new heating element and reconnect the
Package Inclusion ......... 3 terminal.Avoidtouchingtheheatingelementwire.
Specifications ......... 3 5. Reconnect the ground wire after replacing the element then
Parts List .. 3 reassembleunit.
Fig. 4
Fig. 5
2 7
OPERATINGINSTRUCTIONS PACKAGEINCLUSION
PARTSLIST
PartNo. Description
10093 HeatingElement
30104S HotAirGunPlasticHandle
S001 HotAirGunCompleteHandle
Fig. 1
20932 HotAirGunMetalPipe
Fig. 3 P001 DiaphragmPump
Fig. 2
6 3
CAREandSAFETYPRECAUTIONS FUNCTION
Electrostaticdischargesafedesignwithgroundingmeasures.
CAUTION:Misusemaycauseinjuryandphysicaldamage. Voltagepulsesignalcontrolledhotairtemperature.
Foryourownsafety,besuretocomplywiththefollowingprecaution.
Hot air temperature and air pressure are both adjustable by
traditionalknobtypecontrolstosuitdifferentusersneeds.
Temperaturemayreachahighof500Cwhenturnedon.
Withaddedsafetyfeature.Itautomaticallyblowscoolairafteruse
Donotusenearflammablegases,paperandothermaterials.
thusprolongingtheusagelifeoftheheatingsystem.
Donottouchheatedparts,cancausesevereburns.
Warnpeoplearoundworkarea. Compatible with various types of air nozzles to perform various
ThermalProtector typesoftasks.Pleaserefertopage8ofthismanualforalistof
Ifthethermalprotectortrips,reducethetemperaturesetting availablenozzles.
orincreasetheairflowtodecreasetemperaturetosafelevel.
Unitisequippedwithautoshutoffabilitywhentemperature
gets too high and automatically turns on when temperature
droppedtoasafelevel.
OPERATINGINSTRUCTIONS
AutoCoolingFunction
Unit is designed to blow cool air after being turned off. Do
Solder ing
notunplugstationduringthiscoolingprocess.
HandlewithCare 1. Plug in this starts the blowing function but heating element
Neverdroporsharplyjolttheunit. remainscool.
Containsdelicatepartsthatmaybreakifunitisdropped. 2. Turnonthisbeginswarminguptheheatingelement.
Disconnectplugwhennottobeusedforalongperiodoftime.
3. Set temperature and air flow we recommend you to adjust
Turnoffpowerduringbreaks.
temp.around300350Candairflowof13.
Useonlygenuinereplacementparts.
Turnoffpowerandletunitcoolbeforereplacingparts. 4. Applythesolderpaste.
Donotmodifyunit 5. PreheatSMD(seefig.1onpage6).
6. Solderingheattheleadframeevenly (seefig.2onpage6).
7. Washawayexcessflux.
4 5