Heat exchanger: two welded-in, double-wound heat exchangers of steel tubing
Insulation: 500 - 600 litres 800 1000 litres 50 mm PUR hard foam, CFC-free 90 mm PUR soft foam shell, CFC-free
Electric heating: flange heating possible on all tanks an adapter flange is required at the bottom from 800 litres onwards
Scope of delivery: 1 thermometer incl. immersion sleeve art. no.: T 80/100 (500 - 600 litres) HYDRAULIC TESTS CRITERIA:
*The applied test pressure for the tank is 13 bar
*All the welded tanks are applied 100% to hydraulic test *During the hydraulic test any physical changing of the tank is observed and checked for any permanent deformation. *During hydraulic test the welding points is tested. Pressured air is applied to welding points and will be controlled through a strong light if there is any leakage. *Testing duration is 4 minute after the tank reaches to 13 bar.