THIS INSTRUCTION WILL HELP YOU GET THE ELEMENT HYDRAULIC CONTROLLER RUNNING ON CONSTRUCTION OPERATION

STEP 1: POWER CONNECTIONS.

1. Review job prints.


2. Connect grounding lug (NEC Article 250).
3. Connect AC power, motor, and valves.

Low power or signal wires


Ground must always be in
separate conduit from high
power/current wires.
Three phase
building supply
SEE JOB PRINTS FOR MOTOR & VALVE CONNECTIONS

STEP 2: CONSTRUCTION OPERATION ON MACHINE ROOM INSPECTION. STEP 3: CONSTRUCTION OPERATION ON CARTOP INSPECTION.

SCE-CPU
1. On the SCE-CPU and SCE-HVI boards TEMPORARY RUN BOX
CTEN unplug the five connectors pictured to
the left. SCE-UPD
INCP
ICTU 2. Use MCE jumper assembly CPU- 24HWY
ICTD CONSTR-JPR-HY to replace the three 24FS
INCT Run Enable
SCE-CPU and the top SCE-HVI con- 24CTP
INA
nectors (wired as shown). 1 SCE-CPU
ATU 1
ATD 3. Use MCE jumper assembly HVI- Run Up CTEN
1
ABU CONSTR-JPR-HY to replace the GOV/ INCP
ABD SAFH/.. connector (wired SAFC to 2). Run Down ICTU
ICTD
CPU-CONSTR HVI-CONSTR Norm INCT*
RGOK SCE-UPD
+24V From To From To 1 Insp
L24V +24V INCP 2 SAFC
1 2
INCT 2
FRA INA
FRS 2LS SCE-HVI
RGOK EMERGENCY STOP
FRSA
UTL 2LS GOV
FRSM DLN2
USL1 SAFH
USL2 DLN1 SAFC*
DTL GOS2 ESC
SCE-HVI DSL1 GOS1
UTL
USL1 * Remove jumper wire when connecting switch.
USL2
DTL
DSL1
DSL2 REMOVE temporary jumpers before connecting
UETS
DETS
actual equipment. Otherwise, circuit boards will
be damaged (not covered by warranty). ALL
GOV jumpers must be removed before the car is
SAFH released to passenger operation.
SAFC
ESC
2
4. On the SCE-CPU board, INSP, CAR
DOOR BYPASS, HOISTWAY DOOR
BYPASS all UP. FLT BYPASS jumper
in BYPASS position.
5. Power up. Verify UTILS, Construct &
Bypass Faults enabled. Verify Home
screen indicates BP CONSTRUCTION. for Construction Operation
If your job has optional features like emergency power or an oil
pressure input, wire them or add jumpers before you run. See
your job prints and/or the SYSTEM IO/Programmed Inputs 42-QR-1P26 B3
menu to verify additional inputs. Motion Control Engineering. www.mceinc.com. 916 463 9200.