Item Description:
Project Name:
INNERTANK OUTERTANK
EXTERNAL PRESSURE Pe 0 50 mm wc
Preliminary calculation
1/19
Item Tag: 0
Item Description: 0
Project Name: 0
Summation of vertical components of the forces in any and all internal or external ties F 0 kg
braces, diaphragms, trusses, columns, skirt
Weight of external accessories on Roof (platforms, insulation, Nozzles, Suspended deck & Structure) W1 724000 kg
Calculation
Maximum allowable tensile stress for Tension Sts 21000 psi Table 5-1
Allowable tensile stress in Test Condition min (85% Sy, 55% ST) Stt 38500 psi
Roof Support Weight (Rafter weight) 65 kg/m 0.0924495 lb/in Wrs 446691.9516 lb
Thickness calculation at the center of the Roof for Design Internal Pressure
t 5.5 mm
Assumed thickness is sufficient
Thickness calculation at the Edge of the Roof for Design Internal Pressure
t 5.82 mm
Assumed thickness is sufficient
Preliminary calculation
2/19
Item Tag: 0
Item Description: 0
Project Name: 0
Thickness calculation of the Roof for only Gas (internal) Pressure and if (W+F)/At is negligible
t 6.38 mm
Assumed thickness is sufficient
t 4.35 mm
Assumed thickness is sufficient
t 4.52 mm
Assumed thickness is sufficient
Thickness calculation of the Roof for only Gas (Test) Pressure and if (W+F)/At is negligible
t 4.83 mm
Assumed thickness is sufficient
Thickness calculation at the center of the Roof for Design External Pressure
T 717.115 lb/in
t 142.75 mm
Assumed thickness is not sufficient, recheck with revised thickness or design with rafter supports
Preliminary calculation
3/19
Item Tag: 0
Item Description: 0
Project Name: 0
Thickness calculation at the Edge of the Roof for Design External Pressure
Step 1
Step 2
Larger thickness calculated by Equation 18 or 19 is the required thickness. Further calculations using Steps 3 through 6 are unnecessary
t 30.15 mm
Assumed thickness is not sufficient, recheck with revised thickness or design with rafter supports
Thickness of the cylindrical sidewalls at and near the junction of the roof tc 50 mm 1.969 in
Thickness of the roof plate at and near the Juncture of the sidewall th 56.000 mm 2.205 in
Extension of Roof Compression ring outside the shell Wall L 350.000 mm 13.780 in 5.12.5.8
(Does not exceed 16 times its thickness) (896mm)
Actual Width of Roof Compression ring inside the shell wall L1 1050.000 mm 41.339 in
Width of the roof plate considered to participate 0.6sqrt(R2(th-c) Wh 39.150 in 5.12.4.2 (24)
in resisting the circumferential force
Angle between the direction of T1 and a vertical line cos-1(Rc/R2) a 0.896 rad
Since the term (W+F)/At is negligible compared to design pressure, Equation 7 and 13 shall be used in calculating T1 & T2 & T2s 5.10.2.5
Meridional unit force in the roof 1/2*Pi*R2 T1 2822.202 lb/in 5.10.2.5 (7)
Latitudinal unit force in the roof 1/2*Pi*R2 T2 2822.202 lb/in 5.10.2.5 (7)
Circumferential unit force in the cylindrical side wall Pi*Rc T2s 3527.752 lb/in 5.10.2.5 (13)
Preliminary calculation
4/19
Item Tag: 0
Item Description: 0
Project Name: 0
the horizontal projection of the effective compression-ring region width shall be not less than 0.015 times the radius of the tank wall 5.12.5.1
Okay
Since the term (W+F)/At is negligible compared to design pressure, Equation 7 and 13 shall be used in calculating T1 & T2 & T2s 5.10.2.5
Meridional unit force in the roof 1/2*Pt*R2 T1 3527.752 lb/in 5.10.2.5 (7)
Latitudinal unit force in the roof 1/2*Pt*R2 T2 3527.752 lb/in 5.10.2.5 (7)
Circumferential unit force in the cylindrical side wall Pt*Rc T2s 4409.690 lb/in 5.10.2.5 (13)
the horizontal projection of the effective compression-ring region width shall be not less than 0.015 times the radius of the tank wall 5.12.5.1
Okay
Since the external pressure and Weight of roof plate acts down wards, - Sign shall be considered in the calculation
Meridional unit force in the roof R2/2(Pe+(W+F)/At) T1 -641.995 lb/in 5.10.2.5 (4)
Latitudinal unit force in the roof Rs*Pe-T1 T2 500.914 lb/in 5.10.2.5 (5)
Circumferential unit force in the cylindrical side wall Pe*Rc T2s -88.175 lb/in 5.10.2.5 (13)
SUMMARY OF REPORT
Min Required Width of Roof Plate in Compression Ring inside the shell wall 994.398 mm
Provided Width of Roof Plate in Compression Ring outside the shell wall 350.000 mm
Preliminary calculation
5/19
Item Tag: 0
Item Description: 0
Project Name: 0
Roof Weight (including Roof Structure, Top Platform and external accessories) w 0 kg
Calculation
Corrosion Allowance Ca 0 mm
Allowable tensile stress in Test Condition min (85% Sy, 55% ST) Stt 38500 psi R.6.2
Corrosion allowance Ca 0 in
Pressure resulting from the Liquid head at level under consideration Pl 14.4012 psi
Latitudinal unit force of meridional arc P*Rc T2 17292.7795 lb/in 5.10.2.5 (11)
Joint Efficeincy E 1
Min thickness of bottom shell Course max(5.10.4.1.a,Table 5.6, 5.10.3.2 (16)) t 20.9169 mm
THICKNESS CALCULATION FOR INTERNAL DESIGN PRESSURE WITH DESIGN LIQUID LEVEL FOR LATITUDINAL FORCE T2
Course Liquid Liquid Total Latitudinal Required Min.Required Provided New
Weld Joint Stress in
Course No. Width height Pressure Pressure force T2 Thickness Thick as per Thickness Weight
Efficiency Shell (psi)
(m) (m) (psi) (psi) (lb/in) (mm) API 620 (mm) (lb)
1 2.7 1 16.8 14.4012 14.4012 17292.78 20.916 9.525 22 19965.3 197074
2 2.7 1 14.1 12.0867 12.0867 14513.557 17.554 9.525 18 20480.242 161232
3 2.7 1 11.4 9.7722 9.7722 11734.335 14.193 9.525 16 18628.256 143312
4 2.7 1 8.7 7.4578 7.4578 8955.2323 10.832 9.525 11 20678.445 98519
5 2.7 1 6 5.1433 5.1433 6176.0098 7.47 9.525 10 15687.065 89562
6 2.7 1 3.3 2.8288 2.8288 3396.7874 4.108 9.525 10 8627.84 89562
7 2.4 0.85 0.6 0.5143 0.5143 617.56496 0.879 9.525 10 1845.429 79610
Roof Weight (including Roof Structure, Top Platform and external accessories) Wr 0 lb
Preliminary calculation
6/19
Item Tag: 0
Item Description: 0
Project Name: 0
Preliminary calculation
7/19
Item Tag: 0
Item Description: 0
Project Name: 0
THICKNESS CALCULATION FOR INTERNAL PRESSURE AND DESIGN LIQUID LEVEL FOR MERIDIONAL FORCE T1
Shell Course Shell Course Total Total Meridional Required
Weld Joint
Course No. New Weight Corroded Weight Pressure Force Thickness Result
Efficiency
(lb) Weight (lb) W (lb) P (psi) T1 (lb/in) t (mm)
1 197074 197074 858871 14.4012 1 8532.553 10.32 Okay
2 161232 161232 661797 12.0867 1 7169.063 8.671 Okay
3 143312 143312 500565 9.7722 1 5800.821 7.016 Okay
4 98519 98519 357253 7.4578 1 4430.265 5.359 Okay
5 89562 89562 258734 5.1433 1 3053.712 3.694 Okay
6 89562 89562 169172 2.8288 1 1675.971 2.027 Okay
7 79610 79610 79610 0.5143 0.85 298.231 0.424 Okay
Course # 1- For Meridional unit force T1 & For Latitudinal unit force T2
Pressure resulting from the Test Liquid head at level under consideration Pl 23.8945 psi
THICKNESS CALCULATION FOR TEST PRESSURE WITH DESIGN TEST LIQUID LEVEL
Provided Liquid Liquid Total Meridional Latitudinal Required
Total Weight Weld Joint Max (T1,T2)
Course No. Thickness height Pressure Pressure Force force T2 Thickness Result
W (lb) Efficiency (lb/in)
t (mm) (m) (psi) (psi) T1 (lb/in) (lb/in) t (mm)
1 22 858871 16.8 23.8945 23.8945 1 14232.271 28692.215 28692.215 18.930 Okay
2 18 661797 14.1 20.0543 20.0543 1 11952.76 24080.951 24080.951 15.890 Okay
3 16 500565 11.4 16.2142 16.2142 1 9668.558 19469.808 19469.808 12.850 Okay
4 11 357253 8.7 12.374 12.374 1 7381.921 14858.544 14858.544 9.810 Okay
5 10 258734 6 8.5338 8.5338 1 5089.347 10247.28 10247.280 6.770 Okay
6 10 169172 3.3 4.6936 4.6936 1 2795.586 5636.016 5636.016 3.720 Okay
7 10 79610 0.6 0.8534 0.8534 0.85 501.825 1024.752 1024.752 0.800 Okay
Course # 1- For Meridional unit force T1 & For Latitudinal unit force T2
(t-c)/R 0.00073
Thicknesscalculationshallbeasper5.10.3.5
Step 1
Preliminary calculation
8/19
Item Tag: 0
Item Description: 0
Project Name: 0
Preliminary calculation
9/19
Item Tag: 0
Item Description: 0
Project Name: 0
Step 2
Larger thickness calculated by Equation 18 or 19 is the required thickness. Further calculations using Steps 3 through 6 are unnecessary
t 7.01 mm
(t-c)/R 0.00073
(S1+0.8Ss)/Scs 0.1001
1.8Ss/Scs 0
Preliminary calculation
10/19
Item Tag: 0
Item Description: 0
Project Name: 0
SUMMARY OF REPORT
Course Reqd Thick Reqd thk Reqd thk Reqd thk Provided
New Weight Corroded
Course No. Width API 620 INT Pres Test Pres Ext Pres Thickness Result
(lb) Weight (lb)
(m) (mm) (mm) (mm) (mm) (mm)
1 2.700 197074 197074 9.525 20.916 18.93 7 22 Okay
2 2.700 161232 161232 9.525 17.554 15.89 6.14 18 Okay
3 2.700 143312 143312 9.525 14.193 12.85 5.34 16 Okay
4 2.700 98519 98519 9.525 10.832 9.81 4.51 11 Okay
5 2.700 89562 89562 9.525 7.47 6.77 3.84 10 Okay
6 2.700 89562 89562 9.525 4.108 3.72 3.11 10 Okay
7 2.400 79610 79610 9.525 0.879 0.8 2.13 10 Okay
Preliminary calculation
11/19
Item Tag: 0
Item Description: 0
Project Name: 0
Roof Weight (including Roof Structure, Top Platform and external accessories) w 1503500 kg
Calculation
Allowable tensile stress in Test Condition min (85% Sy, 55% ST) Stt 38500 psi R.6.2
Pressure resulting from the Liquid head at level under consideration Pl 13.5011 psi
Latitudinal unit force of meridional arc P*Rc T2 20271.2424 lb/in 5.10.2.5 (11)
Joint Efficeincy E 1
Min thickness of bottom shell Course max(5.10.4.1.a,Table 5.6, 5.10.3.2 (16)) t 26.01976 mm
THICKNESS CALCULATION FOR INTERNAL DESIGN PRESSURE WITH DESIGN LIQUID LEVEL FOR LATITUDINAL FORCE T2
Course Liquid Liquid Total Latitudinal Required Min.Required Provided New
Weld Joint Stress in
Course No. Width height Pressure Pressure force T2 Thickness Thick as per Thickness Weight
Efficiency Shell (psi)
(m) (m) (psi) (psi) (lb/in) (mm) API 620 (mm) (lb)
1 2.65 1 15.75 13.5011 16.3457 20271.242 26.019 9.525 27 20191.747 245184
2 2.65 1 13.1 11.2295 14.0741 17454.101 22.611 9.525 23 20620.193 208847
3 2.7 1 10.45 8.9579 11.8025 14636.959 19.204 9.525 20 20096.149 185024
4 2.7 1 7.75 6.6434 9.488 11766.614 15.732 9.525 18 18113.455 166516
5 2.7 1 5.05 4.3289 7.1735 8896.2698 12.26 9.525 18 13694.864 166516
6 2.7 1 2.35 2.0145 4.8591 6026.0493 8.789 9.525 18 9276.464 166516
7 2.7 1 -0.35 -0.3 2.5446 3155.7048 5.317 9.525 18 4857.873 166516
8 1.2 1 -3.05 -2.6145 0.2301 285.36024 1.845 9.525 42 178.967 172749
20 Total 1477868
Roof Weight (including Roof Structure, Top Platform and external accessories) Wr 3314616.1 lb
Preliminary calculation
12/19
Item Tag: 0
Item Description: 0
Project Name: 0
Preliminary calculation
13/19
Item Tag: 0
Item Description: 0
Project Name: 0
THICKNESS CALCULATION FOR INTERNAL PRESSURE AND DESIGN LIQUID LEVEL FOR MERIDIONAL FORCE T1
Shell Course Shell Course Total Total Meridional Required
Weld Joint
Course No. New Weight Corroded Weight Pressure Force Thickness Result
Efficiency
(lb) Weight (lb) W (lb) P (psi) T1 (lb/in) t (mm)
1 245184 231563 4792484 16.3457 1 9520.58 13.015 Okay
2 208847 195227 4547300 14.0741 1 8143.475 11.35 Okay
3 185024 171147 4338453 11.8025 1 6761.706 9.678 Okay
4 166516 152640 4153429 9.488 1 5350.279 7.971 Okay
5 166516 152640 3986913 7.1735 1 3936.477 6.261 Okay
6 166516 152640 3820397 4.8591 1 2522.736 4.551 Okay
7 166516 152640 3653881 2.5446 1 1108.934 2.841 Okay
8 172749 166580 3487365 0.2301 1 -304.869 1.131 Okay
Course # 1- For Meridional unit force T1 & For Latitudinal unit force T2
Pressure resulting from the Test Liquid head at level under consideration Pl 22.4011 psi
THICKNESS CALCULATION FOR TEST PRESSURE WITH DESIGN TEST LIQUID LEVEL
Provided Liquid Liquid Total Meridional Latitudinal Required
Total Weight Weld Joint Max (T1,T2)
Course No. Thickness height Pressure Pressure Force force T2 Thickness Result
W (lb) Efficiency (lb/in)
t (mm) (m) (psi) (psi) T1 (lb/in) (lb/in) t (mm)
1 27 4792484.1 15.75 22.4011 25.95685 1 15480.251 32190.583 32190.583 22.740 Okay
2 23 4547300.1 13.1 18.632 22.18775 1 13174.577 27516.305 27516.305 19.660 Okay
3 20 4338453.1 10.45 14.863 18.41875 1 10864.303 22842.151 22842.151 16.570 Okay
4 18 4153429.1 7.75 11.0228 14.57855 1 8506.821 18079.699 18079.699 13.430 Okay
5 18 3986913.1 5.05 7.1826 10.73835 1 6146.965 13317.246 13317.246 10.290 Okay
6 18 3820397.1 2.35 3.3424 6.89815 1 3787.108 8554.793 8554.793 7.150 Okay
7 18 3653881.1 -0.35 -0.4979 3.05785 1 1427.189 3792.216 3792.216 4.010 Okay
8 42 3487365.1 -3.05 -4.338 -0.78225 1 -932.606 -970.114 -932.606 0.890 Okay
Course # 1- For Meridional unit force T1 & For Latitudinal unit force T2
(t-c)/R 0.00081
Thicknesscalculationshallbeasper5.10.3.5
Step 1
Preliminary calculation
14/19
Item Tag: 0
Item Description: 0
Project Name: 0
Preliminary calculation
15/19
Item Tag: 0
Item Description: 0
Project Name: 0
Step 2
Larger thickness calculated by Equation 18 or 19 is the required thickness. Further calculations using Steps 3 through 6 are unnecessary
t 19.51 mm
(t-c)/R 0.00081
(S1+0.8Ss)/Scs 0.4985
1.8Ss/Scs 0.1085
STABILITY CHECK OF TANK SIDE WALL FOR EXTERNAL PRESSURE + WIND PRESSURE
191.356 mph
Preliminary calculation
16/19
Item Tag: 0
Item Description: 0
Project Name: 0
IntermediateGirdersRequired
Stiffener distance h1 3m
h1 9.8426 ft
Minimum required section modulus of stiffener Dh1/10000*(v/120) Z 106.926 in API 650 5.9.7.6
Preliminary calculation
17/19
Item Tag: 0
Item Description: 0
Project Name: 0
Stiffeners @ 5% = 1164 kg
Preliminary calculation
18/19
Item Tag: 0
Item Description: 0
Project Name: 0
SUMMARY OF REPORT
Course Reqd Thick Reqd thk Reqd thk Reqd thk Provided
New Weight Corroded
Course No. Width API 620 INT Pres Test Pres Ext Pres Thickness Result
(lb) Weight (lb)
(m) (mm) (mm) (mm) (mm) (mm)
1 2.650 245184 231563 9.525 26.019 22.74 19.5 27 Okay
2 2.650 208847 195227 9.525 22.611 19.66 19.11 23 Okay
3 2.700 185024 171147 9.525 19.204 16.57 18.77 20 Okay
4 2.700 166516 152640 9.525 15.732 13.43 18.46 18 Not Okay
5 2.700 166516 152640 9.525 12.26 10.29 18.18 18 Not Okay
6 2.700 166516 152640 9.525 8.789 7.15 17.89 18 Okay
7 2.700 166516 152640 9.525 5.317 4.01 17.6 18 Okay
8 1.200 172749 166580 9.525 1.845 0.89 17.31 42 Okay
Preliminary calculation
19/19